Nothing Special   »   [go: up one dir, main page]

FQP For AAC Block Work

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

CUSTOMER: Quality Management System

PROJECT: Format No. RMC/QA/FQP/014


CONSULTANT: RAMA CIVIL INDIA CONSTRUCTION PRIVATE LIMITED Revision-No- 00
CLIENT: Revision Date:

FIELD INSPECTION TEST PLAN FOR BLOCK WORK


Method of Frequency Reference Format of Inspection Authority
NATURE OF CHECK /
SL No. ACTIVITY Category Procedure / Acceptance Norms CLIEN REMARKS
INSPECTION Check Of Check Record CONT CNSLT
Document T
1 Material
Lab. Once Per BIS/6041/6042/644 FORMAT
2 Compressive strength of block Major Relevant Standard P W R/W
Test/MTC 20000 Nos 1/3809 NO
Lab. Once Per BIS/6041/6042/644
3 Dimensional Major Relevant Standard P W R
Test/MTC 20000 Nos 1/3809
Lab. Once Per BIS/6041/6042/644 FORMAT
4 Density Major Relevant Standard P W R
Test/MTC 20000 Nos 1/3809 NO
Manufacturer
Test
5 Adhesive Major Every lot Relevant Standard MTC P W R
Certificates
(MTC)
6 AAC BLOCK WORK
As per Drawing /
7 Check for workmanship/Dimension Major Inspection 100% Relevant Standard P W RR
Tech Spec.
Checklist
Adhesive check ,Laying , Setting out As per Drawing /
8 Major Inspection 100% Relevant Standard P W RR
Alignment. Tech Spec.

LEGENDS : W - WITNESS, R- REVIEW, RW- RANDOM WITNESS, RR- RANDOM REVIEW, P- PERFORM

Approved By
Himanshu Chaudhary
Lead- Qulity Management System