Activa S Horiba
Activa S Horiba
Activa S Horiba
Simply competitive Spectrometer of high quality Sensor for Spectroscopy Software for all Supplies
ACTIVA S
Automotive AutomotiveTest TestSystems Systems || Process Process& &Environmental Environmental || Medical Medical || Semiconductor Semiconductor || Scientific Scientific
Ultima 2 ACTIVA S
Simply competitive
ACTIVA-S CCD-based ICP Atomic Emission Spectrometer Combines Simplicity with a high performance CCD Detector
ACTIVA-S is a CCD-based ICP-AES instrument based upon A Platform for the Future, maintaining the Strengths of HORIBA Scientific Spectrometers while incorporating advanced CCD (Charge Coupled Device) technology to improve quality and flexibility. ACTIVA-S is the perfect Solution to first-time operators and for routine analysis with defined applications. Simplicity Both Spectrometer and Detector of ACTIVA-S offer the ease-of-use that every analyst wishes. Plug-&Play operations and automatic optimisations help the user to operate the instrument at its best and achieve excellent analytical results. Flexibility The Total Plasma View, from Superior vertical torch based radial observation, combined with a light-rich, high performance optical System, allows the analyst to run all types of Samples. The full wavelength coverage, from 160 to 800 nm, emphasizes this flexibility: a unique and proprietary ICP-based Spectral database (from S3-base: Single-element Spectra, Spectroscopic data) leads to optimum Selectivity with potential use of all ICP lines, and a Superior Semiquantitative analysis offers a precise identification of the Samples. Quality The combination of HORIBA Scientific high quality optics with the advanced features of the CCD detector is optimized to make the difference. The ultra-low noise and excellent practical dynamic range of the CCD, associated to the constant resolution, aberration free, high luminosity holographic gratings of the optical System, enable the instrument to fit the needs of Simplicity, Stability and Quality. The high performance CCD Sensor designed for Scientific Spectroscopy provides excellent analytical capabilities, obtained with minimal operator optimisation. The powerful ACTIVAnalyst Software enhances the unique capabilities of the instrumental configuration.
ACTIVA S
A powerful pre-Shot algorithm automatically optimizes exposure time and column binning, which takes advantage of the full benefit of the maximum available dynamic range. Binning of the 256 pixel-high column results in a decrease in read-out time with no addition of readout noise and an increase in the linear dynamic range. The combination of ultra low noise and binning
capability then provide a practical dynamic range (Signal before saturation-to-readout noise ratio) of 107, with a linear response range of 5 decades minimum, for each line. Analysis of trace and major elements can be easily performed with one measurement, without requiring dilution.
ACTIVA S
Supplies
Samples introduction systems
Sample Type / Item
Standard kit P/N: 24 031 500
Nebuliser
Concentric, glass P/N: 47 929 058 50 psi argon gas, 1 mL/min sample uptake
Spray Chamber
Cyclone, glass P/N: 47 929 056
Concentric, glass P/N: 24 072 150 30 psi argon gas, 2 mL/min sample uptake Parallel flow, PEEK/Teflon P/N: 47 929 024 50 psi argon gas, 1 mL/min sample uptake
kit P/N: 24 072 160 (concentric / cyclo) 24 031 510 (parallel / cyclo) 24 031 570 (parallel / Scott)
Scott, glass P/N: 31 031 491 If stability is the main criteria Requires a nebuliser adapter (P/N: 24 031 0
Cyclone with central transfer tube, glas P/N: 47 929 063 For good sensitivity and stability compromise HF kit P/N: 24 031 710 Parallel flow, PEEK/Teflon P/N: 47 929 024 50 psi argon gas, 1 mL/min sample uptake Cyclone, Teflon P/N: 47 929 031
Concentric, glass (limited volume) P/N: 47 929 053 50 psi argon gas, 100 L/min sample uptake Concentric, glass (volatile solvent) P/N: 24 072 100 30 psi argon gas, 0.5 mL/min sample uptake
Cyclone, glass P/N: 31 031 279 Mini-cyclone, glass P/N: 47 929 049 For sensitivity at low uptake and very fast washout Cooled cyclone, glass (Peltier effect) P/N: 24 072 210 For optimum sensitivity with volatile samples Scott, glass P/N: 31 031 491 Requires the JY nebuliser adapter (P/N: 24 031 070)
Organics / Slurries kit P/N: 24 031 610 (0.7 mm id nebuliser) 24 031 600 (1 mm id nebuliser)
Jobin Yvon, Pt needle, Zr nozzle P/N: 24 031 060 0.7 mm id needle Jobin Yvon, Stainless Steel needle, Zr nozzle P/N: 24 031 050 1 mm id needle (for large particulates, ie wear metals)
Other accessories
USN nebuliser P/N: 24 031 650 For aqueous solutions (gain in sensitivity by a factor of 5 to 20) CMA P/N: 24 072 140 Kit P/N: 24 031 660 (concentric) ; 24 031 670 (parallel) For simultaneous analysis of hydrides and normal elements
Torch
Demountable torch P/N: 21 356 110 Sheath gas system (glass) P/N: 21 356 040 Demountable torch P/N: 21 356 110
Observations
Specifications: high sensitivity, short washout time Examples of application: routine applications of clean aqueous or organic solutions (water,)
Specifications: suitable to high Total Dissolved Solids (TDS), high precision Examples of application: waste, sediment, sea water, metals (Cu 30 g/l, precious metals,), alloys, NaCl 300 g/l, LiBO2 20 g/l (fusion), Leachates, cement, Ca sulfate require preferably the concentric nebuliser Argon humidifier (P/N: 24 056 810) is required with the concentric nebuliser
020)
ss
Demountable torch P/N: 21 356 110 Alumina inner (P/N: 31 032 312) and outer (P/N: 31 032 313) tubes available if B, Na,Si to measure at trace levels Sheath gas system (inert material) P/N: 20 925 160 Demountable torch P/N: 21 356 110
Specifications: suitable to hydrofluoric acid (HF) Examples of application: refractory samples requiring HF digestion (Ti base, silica, ashes, filters (air samples))
Specifications: suitable to low volume or volatile samples, with optimum sensitivity Examples of application: biological or nuclear samples (small amount); ethanol, MIBK, gasoline, acetic acid (volatile)
Demountable torch P/N: 21 356 110 Sheath gas system (glass) P/N: 21 356 040
Specifications: robust and stable operating conditions, high precision Examples of application: wear metals in oil, fuel, biodiesel, particulates Oxygen Kit (P/N: 24 056 360) is required for analysis of Na and K at ppb levels in organic samples
Hot Wax P/N: 24 056 140 (ULTIMA 2) ; 24 056 740 (ACTIVA family) For samples that solidify at room temperature (heating from sample tube to spray chamber)
TECHNICAL SPECIFICATIONS
Generator Cooling system Exhaust Plasma Radio frequency, solid-state 40.68 MHz, water cooled GenCo water chiller for the generator and the coil direct exhaust connection for plasma compartment Fully demountable torch, 3 mm i.d; alumina injector, 12 L/min plasma gas, 0.2 L/min sheath gas Concentric glass nebulizer, cyclonic glass spray chamber, 3 channels peristaltic pump Thermo-regulated, 0.64 meter focal length, dual back-to-back gratings, 4343 g/mm and 2400 g/mm used in the 1st order with optical resolution <12 pm for 160-430 nm and <22 pm for 430-800 nm. 160 - 800 nm Open electrode CCD, 1024x256 pixels, pixel size 26x26 m, Peltier cooled
OPTIONS
AS-500 Autosampler with rinse station Ar humidifier Micro / high dissolved solids / inert material / organic nebulizers Scott / HF resistant / cooled spray chambers Ultrasonic nebulizer CMA for simultaneous measurement of hydride forming elements and other elements Oxygen kit for organic samples Laser ablation system
PHYSICAL DATA
Refer to ACTIVA-S Pre-Installation Guide for more details. Depth Width Height Weight Power Cooling Water Argon Nitrogen Exhaust Environmental 698 mm (27.5 in) 1321 mm (52 in) 604 mm (23.8 in) 195 kg (430 lb) Single-phase, 220-240 V, 50/60 Hz, 4 kVA 2 to 3 L/min, 3 bar 99.995% purity 160 to 190 nm, 99.999% purity 120 to 160 nm, 99.9995% purity 250 m3/h (150 cfm) 20 to 80% humidity non-condensing, 18-24C at 2C
www.horiba.com/scientific
France: USA: Japan: Germany: Italy: UK: China: Brasil: Spain: Other countries:
HORIBA Jobin Yvon S.A.S., 16-18 rue du Canal, 91165 Longjumeau cedex - Tel: +33 (0)1 64 54 13 00 - Fax: +33 (0)1 69 09 07 21 - Email: info-sci.fr@horiba.com HORIBA Jobin Yvon Inc., 3880 Park Avenue, Edison, NJ 08820-3012 - Toll-free:+1-866-jobinyvon - Tel: +1 732 494 8660 - Fax: +1 732 549 5125 Email: info-sci.us@horiba.com HORIBA Ltd., Scientific Instruments Sales Dept., Alte-Building, Higashi-Kanda, 1-7-8 Higashi-Kanda, Chiyoda-ku, 101-0031 Tokyo - Tel: +81 (0)3 3861 8231 Fax: +81 (0)3 3861 8259 - Email: info-sci.jp@horiba.com HORIBA Jobin Yvon GmbH, Hauptstrasse 1, 82008 Unterhaching - Tel: +49 (0)89 46 23 170 - Fax: +49 (0)89 46 23 17-99 - Email: info-sci.de@horiba.com HORIBA Jobin Yvon Srl, Via Cesare Pavese 35/AB, 20090 Opera (Milano) - Tel: +39 02 57 60 30 50 - Fax: +39 2 57 60 08 76 - Email: info-sci.it@horiba.com HORIBA Jobin Yvon Ltd, 2 Dalston Gardens, Stanmore, Middlesex HA7 1BQ - Tel: +44 (0)20 8204 8142 - Fax: +44 (0)20 8204 6142 - Email: info-sci.uk@horiba.com HORIBA Jobin Yvon SAS, Room 1801, Capital Tower N6 Jia, Jianguomenwai Av., Chaoyang District, Beijing 100022 - Tel: +86 (0)10 8567 9966 Fax: +86 (0)10 8567 9066 - Email: info-sci.cn@horiba.com HORIBA Scientific, Av. das Naes Unidas, 21.735, Bairro Jurubatuba, So Paulo CEP 04795-100 - Tel: +11 5545 1500 - Fax: +11 5545 1570 Email: info-sci@horiba.com HORIBA Jobin Yvon, C Francisco Silvela 56 Duplicado 2 DIZQ, Madrid 28028 - Tel: +34 91 724 1657 - Fax: +34 91 724 1373 - Email: info-sci@horiba.com Tel: +33 (0)1 64 54 13 00 - Email: info-sci@horiba.com
| Process | Process | Medical | Medical | Semiconductor | Semiconductor | Scientific | Scientific Automotive Automotive Test Test Systems Systems & Environmental & Environmental
This document is not contractually binding under any circumstances - Printed in France - HORIBA Jobin Yvon 03/2011