Ctalogo de AA
Ctalogo de AA
Ctalogo de AA
contrAA 800
2
contrAA 800
Flame mode
Solid sampling
HydrEA
3
contrAA 800
Atomic Absorption. Redefined.
4
Inspiration from practical experience A single light source for all applications
The contrAA 800 was developed – by laboratory experts, The continuum emission spectrum of a xenon short arc lamp
for laboratory experts – to be as compact and as easy to use covers the complete spectral range of AAS. Lamp-changing
as possible. With the dual atomizer concept, both flame and for AAS is a matter of the past. Replacement costs compared
graphite furnace atomization are combined in a compact to HCL instruments are significantly lower, whereas the
sample compartment with minimized footprint and light intensity is significantly higher than with traditional
maximum performance. The automatic atomizer change AAS light sources. It provides an excellent signal-to-noise
and the two-dimensional atomizer alignment allow for ratio resulting in improved detection limits. Any element in
flexible and easy handling and facilitate switching between the applicable spectral range can be analyzed on primary
the different atomization techniques. or secondary lines. Along with metals and semi-metals,
non-metals like sulfur, phosphorus, fluorine, and halogens
can also be determined by evaluating molecule absorption
bands, extending the application range of the contrAA 800.
High-resolution optics
High resolution – confidence in results for routine applications. Comprehensive quality control
A high-resolution spectrometer with a CCD detector maps a functions guarantee reliable and traceable results at any
high-resolution absorption spectrum for each sample. Thus, time. Pre-programmed methods and optimization routines
providing comprehensive and extremely detailed information simplify method development and ensure ideal measuring
on the sample. The 3D spectrum display allows for visual conditions. Maximum flexibility even for challenging
proof of the correct evaluation of the absorption lines and analyses beyond daily routine is provided by simultaneous
their spectral background. It provides a tool for checking the evaluation of multiple element lines as well as advanced
absence of spectral interferences, which serves to assure correction algorithms for spectral background correction.
correct measurements and strengthens confidence in results.
Pre-programmed methods
Simultaneous quantification Wide range of innovative evaluation tools
The spectrum provides information beyond a single Quality control function for Good Laboratory Practice
element line and offers vast advantages in data evaluation. FDA 21 CFR Part 11 Compliance
If required, other elements contained in the sample,
which occur within the spectral observation range can be Fe
quantified simultaneously. Powerful software tools such
as automatic baseline correction (ABC) or simultaneous Ni
correction of spectral interferences (CSI) significantly boost V
V V
your productivity. The additional side pixel evaluation is an
established evaluation routine. It allows the adaptation of
the concentration range for the determination of trace and
Time
major elements in the same sample with a single method.
Wavelength
Pre-programmed satisfaction
3D Spectrum plot of one sample with signals of different elements
The ASpect CS software was exclusively developed for (vanadium, nickel, iron)
multi-element analysis with the contrAA 800. The intelligent
user interface is intuitive in operation and optimized
6
Minimum effort in sample preparation with direct solid sampling – SSA 600
System with fully automated flow injection or batch mode for difficult matrices
Trace analysis with unique combination of graphite furnace and hydride technique
Mercury analysis with additional amalgamation module and mercury cell
Konrad-Zuse-Str. 1
Subjects to changes in design and scope of delivery as well as further technical development.
Germany