REF. No.: LPHOSD-22/1856 Date: May 25, 2022

BUYER : Provincial Health Office - Surigao Del Sur Attention: DR. ERIC T. MONTESCLAROS, MD, CLS, MHA
Capitol Hills, Telaje, Tandag, Surigao Del Sur Provincial Health Officer II

PAYMENT TERMS DELIVERY VALIDITY

30 days 12 weeks upon receipt of confirmed order 30 days

Part
DESCRIPTION UNIT PRICE (Php) LINE TOTAL (Php)
Number

818-09100-2 Compact Array Optical Emission Spectrometer 1 unit inclusive


Model: PlasmaQuant 9100
Brand: Analytik Jena Origin: Germany

Array ICP OES - Compact bench-top ARRAY optical emission spectrometer with an
inductively coupled plasma for multi-element analyses of the highest precision,
fully PC controlled and an optional autosampler.
- Capable of direct seawater analysis without dilution of samples

High-Resolution Optics
- High-Resolution Echelle Double Monochromator with fast order preselection
and minimal intensity losses to scattered light for
interference-free routine analysis with the highest sensitivity
- Reflective optical components with innovative protective coatings
and 10 year long term warranty on optics
- Echelle grating with 76° blaze angle that yields an optical resolution
of 1:145,000 as well as continuous coverage of the wavelength
range from 160 - 900 nm with access to more than 43,000 emission lines
- A spectral resolution of 0.002 nm at 200 nm, 0.006 nm at 400 nm
and 0.009 nm at 600 nm for interference-free analysis in complex
matrices like rare earths, high-alloyed steel, petrochemicals etc.
improving detection limits, precision and productivity
- FWHM values of ≤ 3.5 pm for As 193.696, P 213.618 and Cd 228.022 nm
- Fully automated internal neon correction for unique wavelength accuracy
of <0.4 pm that eradicates the need for thermostatting the optical bench
- Encapsulated and argon purged optical bench (2 L/min) that eliminates
air, dust particles and moisture from the entire optical path.
The purge gas is fully recycled and re-used as counter gas (at the cone)
for high-sensitivity axial plasma views over the whole wavelength range
- Peltier-cooled (-10°C) CCD ARRAY detector with high quantum efficiency,
fast simultaneous background correction, increased UVsensitivity
and reduced warm-up times
- Signal integration modes for lowest detection limits (peak), for simultaneous
detection of multiple elements (spectrum) and for full wavelength scan
- Free selection of the number/position of evaluation pixels for
improved detection limits and increased applicability
- Elaborate tool for the Correction of Spectral Interferences (CSI) that
improves detectability, precision and productivity in complex
matrices like rare earths, high-alloyed steel, petrochemicals etc.
- Dynamic baseline fitting via Automatic Baseline Correction routine
(ABC, patented) for improved data handling, precision and
productivity including for complex sample matrices
Page 2 of 4

Part
DESCRIPTION UNIT PRICE (Php) LINE TOTAL (Php)
Number
V Shuttle Torch
- Easily accessible and clearly laid out sampling system with V Shuttle Torch
realizing short distances between sample and plasma for significantly
reduced delay times
- Vertical plasma geometry for improved tolerance of complex
matrices and high sample loads (e.g. petrochemical, saline or
metallic materials) without clogging or soot formation (deposit-free)
- Best accuracy (RSD), blank values and range of samples to be
analyzed without sample-pretreatment
- Unique shuttle design, i.e. firm and sliding torch base from thermally
and chemically resistant materials with built-in gas connections for
high safety, precision and durability
- Fully demountable torch with separable inner and outer tubes and
injector for various applications (aqueous, HF, organic, salt etc.)
- Plug-and-play installation of tubes and injector for simple
maintenance and high method flexibility
- Shuttle interlock for quick, safe and lasting glass-free and tube-free
connections to all gases and spray chamber
- Precision auto-alignment for reproducible torch positioning w/o re-alignment
- Spacing between injector tip and coil can optimized to further suppress
carbon-built-up (petrochemicals) or precipitation (brines)improving
plasma performance, precision and torch life time without affecting torch alignment

Dual View PLUS


- Dual View PLUS plasma observation offers 2+2 plasma views for
the synchronous analysis of analyte contents ranging from low ppb
to high wt.% without sample preparation
- Automatic attenuation of the radial light extends the working range
towards higher concentration (radial PLUS)
- Automatic attenuation of the axial light allows to measure higher
concentrations without sample dilution or switching to radial view,
which typically requires optimisation of the viewing position (axial PLUS)
- Fully automated optimisation of the plasma viewing position in axial,
axial PLUS, radial and radial PLUS plasma views
- Fast switching between axial, axial PLUS, radial and radial PLUS
plasma views by a transfer optic in one method for increased flexibility
and productivity without additional purge step or repetitive measurements

High-Frequency Generator
- Free-running 40 MHz generator with solid state power supply and
instant power matching yielding lowest signal-to-noise and excellent
long-term plasma stability at the highest plasma loadings (reproducibility)
- Incremental power variation between 700 and 1700 W for increased applicability
that includes undiluted alcohols and naphtha, saturated brines etc.
- Cooled four-winding induction coil for maximum energy transfer (at
high plasma loadings) and a longer plasma (for improved sensitivity)
- Realization of shortest warm-up times allow simple maintenance,
high method flexibility as well as shift-operation (instrumental shutdown)
with high precision and lowest running costs

SCS – Self Check System


Sensors continuously monitor:
- All gas pressures and flow rates
- Temperatures and flow of cooling agent
- Door of torch compartment (open/closed)
- Extraction rate of the exhaust system
- Positioning of V Shuttle Torch
- Pressure of the purge gas in the spectrometer
- Plasma intensity and stability for protection of glassware
- Nebulizer blockage to protect V Shuttle Torch
- Generator power for emergency shutdown
Page 3 of 4

Part
DESCRIPTION UNIT PRICE (Php) LINE TOTAL (Php)
Number
Software
Software ASpect PQ
The Aspect PQ software controls, monitors and documents all of the processes of the entire
PlasmaQuant 9100 system. Its modular design offers you the flexibility to work with preset
routine methods, as well as the flexibility to develop customized methods. Online status
updates for remote devices like smart phones, or tablets increase the productivity of
unattended operations. Powerful and automated data evaluation tools such as an automatic
baseline correction algorithm (ABC) and a tool for the correction of spectral interferences (CSI)
greatly enhance ease-of-use for operators, eliminate the need for guesswork in data evaluation
and significantly boost the productivity of your analytics. Thanks to a clear-cut, multilingual
user interface, you can quickly generate methods geared to each matrix by selecting the
elements to be determined and the preferred emission lines. All pre-installed method
parameters are loaded automatically and can be easily modified.
Powerful optimization, evaluation, and post-calculation routines
Compliant with 21 CFR Part11 and FDA module with user management
Innovative routines for baseline connection (ABC), interference correction (CSI), etc.
LIMS connection

The ASpect PQ software fully complies with FDA requirements. User rights management
and individual passwords ensure that the system can only be accessed by authorized persons.
All important events, such as logon/logoff, measurements, calibrations, and messages
generated by the Self Check System, are recorded in the Audit Trail. Measured data can
undergo routine review and approval using electronic signatures.

Scope of delivery
• PlasmaQuant 9100 basic unit
• Completion set
• Software ASpect PQ
• User Manual PlasmaQuant 9100 series
• User manual ASpectPQ
• Instrument logbook
• Mousepad AJ

Technical Data
Dimension (width x depth x height): 990 mm x 855 mm x 940 mm; Weight (netto): 170 kg
Ambient operating temperature: 15 °C - 35 °C; Humidity: 20% - 90%
Line Voltage: 230 V; Line Frequency: 50 Hz60 Hz; Max power consumption: 4600 VA
Fuse protection: 32 A

810-88001-0 Water-air-chiller 1 unit inclusive


Standard water-air chiller for PlasmaQuant 9100
• Labtech H150-3000 sv chiller
Dimension (width x depth x height): 460 mm x 735 mm x 703 mm; Weight (netto): 92 kg
Ambient operating temperature: 8 °C - 35 °C;
Max noise emission: 57 db
Line Voltage: 230 V; Line Frequency: 50 Hz60 Hz;

810-88006-0 Standard Kit 1 kit inclusive


Sample introduction system recommended for aqueous samples
(e.g. environmental, food, pharma applications)
Scope of supply:
• Set PVC-pump tubing sample black/black
• SetPVC-pump tubing waste red/red
• V Shuttle Torch, demountable, 2mm injector
• Torch Bonnet
• concentric nebulizer 1mL/min
• spray chamber cyclone 50mL
Page 4 of 4

Part
DESCRIPTION UNIT PRICE (Php) LINE TOTAL (Php)
Number

810-88040-0 Consumables Set Standard Kit ICP-OES 1 set inclusive


Recommended consumables for approx. 1000 analysis
Scope of supply:
• Torch Bonnet
• Quartz Inner Tube
• 2x Quartz Outer Tube
• Tapered Quartz Injector 2,0 mm
• 2x Sets PVC pump tubing for sample (black/black)
• 1x Set PVC pump tubing for waste (red/red)
• 3x waste tubing for spray chamber
• 3x nebulizer tubing
• Set O-Rings for demountable Torch
• HF deflector spring

810-88015-0 Teledyne-Cetac ASX-560 autosampler for ICP-OES and ICP-MS 1 unit inclusive
Next generation autosampler with integrated rinse function is sleek and durable by design.
Scope of delivery
- Basic device with configurable XYZ movement
- 4 x sample rack (60 positions) plus 1 x standards rack (10 positions)
- new, variable peristaltic-pump allowing rinse flow rates from 0.1 to 80mL/min
- 2 x RS232 serial and 1 x USB (virtual com) ports
- Rinse bottle
- Connection cables

Items to be supplied locally: 1 lot inclusive


a.) PC & Printer with licensed OS and Office, 1 Set (specifications compatible with the ICP unit)
b.) Argon gas UHP, 4.6, content & cylinder
c.) Argon gas regulator 2 stages (capable to regulate 90psi)
d.) UPS, 10kVA, 15 mins back-up time, 0.9 Power Factor
e.) Exhaust System
f.) Gas Lines
g.) Standards for calibration - shall require PNP permit and license of end-user
Assurance Grade Quality Control Standard 23, 1,000 ug/mL (1000 ppm) for AA and ICP in 10% HNO3, 125 mL

TOTAL PRICE FOB SURIGAO


INCLUSIVE of 12% VAT
Php 6,500,000.00

NOTES: 1.) Above price package is inclusive of one (1) year warranty on parts and services with 1 free preventive maintenance within the warranty period
2.) Above price package is inclusive of delivery, installation, commissioning, and onsite** local training by Brownstone engineers and applications chemist
(**additional expenses for safety protocol that is COVID related, is for the customer's account).

BROWNSTONE ASIA-TECH, INC. Approved by:

Jinebeth Pacaña Heidi S. Bate


Technical Sales Executive Sales Operations Manager