6 VOLT
PHYSICAL SPECIFICATIONS
MODEL NAME TERMINAL TYPE DIMENSIONS B INCHES (mm) WEIGHT F LBS. (kg) HANDLES INSTALLATION ORIENTATION
ELECTRICAL SPECIFICATIONS
VOLTAGE CAPACITY A AMP-HOURS (Ah) ENERGY (kWh) INTERNAL RESISTANCE (mΩ) SHORT CIRCUIT CURRENT (amps)
SYSTEM VOLTAGE 6V 12V 24V 36V 48V 0.005 volt per cell for every 1°C below 25°C 0.005 volt per cell for every 1°C above 25°C
0.0028 volt per cell for every 1°F below 77°F 0.0028 volt per cell for every 1°F above 77°F
Maximum Charge Current (A) 20% of C 20
Absorption Voltage (2.40 V/cell) 7.20 14.40 28.80 43.20 57.60 OPERATIONAL DATA
Float Voltage (2.25 V/cell) 6.75 13.50 27.00 40.50 54.00 OPERATING TEMPERATURE SELF DISCHARGE
75 2.09 6.27
50 2.04 6.12
25 1.99 5.97
0 1.94 5.82
SOLAR CYCLE-LIFE PERCENT CAPACITY VS. TEMPERATURE
5000 140 60
4500 120 50
4000 40
100
3500 30
80
Cycles
Temperature (F)
Cycles
Temperature
Temperature
60
10
Number ofof
2500
Number
40
2000 0
20
1500 -10
0
1000 -20
0 -40 -40
0% 20% 40% 60% 80% 100% 0% 20% 40% 60% 80% 100% 120%
Depth ofDepth
Discharge
of Discharge Percent
Percent ofof Available
Available CapacityCapacity
10°C (50°F)
80 2.10
Recharge Threshold @ 75% SOC
75 2.09
60 2.06
25°C (77°F)
Time (hrs)
10.0
20 1.98
1.0
0 1.94
0 2 4 6 8 10 12 14 16 1 10 100
BATTERY DIMENSIONS (shown with M8, height is 12.07 (307) with LT)
10.30 (262)
7.06 (179)
LENGTH
COVER WIDTH
7.02 (178)
CASE WIDTH
10.73 (273)
10.18 (259) HEIGHT
10.57
(268)
6.98 (177)
10.26 (261)
TERMINAL TYPED
15 M8 M8 15 M8 M8 WITH LT ADAPTER (ADAPTER PROVIDED BUT NOT INSTALLED)
Battery Height with Terminal in Inches (mm)
12.07 (307)
Battery Height with Terminal in Inches (mm)
10.57 (268) Torque Values in-lb (Nm)
Connection to M8: 85 – 90 (10 – 11)
Torque Values in-lb (Nm) Connection to LT: 65 – 75 (7.5 – 8.5)
Bolt: 85 – 90 (10 – 11)
Bolt Size
M8 x 1.25
A. The amount of amp-hours (Ah) a battery can deliver when discharged at a constant rate at 86°F (30°C) for all rates and C. Height taken from bottom of the battery to the highest point on the battery. Heights may vary depending on type of terminal.
maintain a voltage above 1.75 V/cell. Capacities are based on peak performance. D. Terminal images are representative only.
B. Dimensions may vary depending on type of handle or terminal. Batteries should be mounted with 0.5 inches E. Batteries in storage should be charged when they decline to 75% State of Charge (SOC).
(12.7 mm) spacing minimum. F. Weight may vary.
© 2021 Trojan Battery Company, LLC. All rights reserved. Trojan Battery Company is not liable for damages that may result from any information provided in or omitted
from this publication, under any circumstances. Trojan Battery Company reserves the right to make adjustments to this publication at any time, without notice or obligation.