Generic Type Cross-linked water-based epoxy

A water-based epoxy finish that is easy to apply, has an attractive high gloss appearance, and has
very good chemical resistance. Sanitile 555 VOC has minimal odor and is less than 100 g/L VOC. It
has significant improvements in film hardness and toughness over straight acrylic or acrylic-epoxy
Description
coatings and is more chemically and physically resistant. It is therefore ideal for more aggressive
exposures on walls and structural components than acrylic-modified epoxies. It may also be used
for light to moderate duty floors.

• Very good chemical resistance


• Resists repeated cleaning
• High gloss finish for ease of cleaning
Features • Low odor, VOC is <100 g/L
• Fast dry to touch and recoat
• Hard, tough, abrasion resistant film
• Suitable for use in USDA inspected facilities

Color Refer to Carboline color card

Primer Normally applied over other Sanitile primers/sealers

Dry Film Thickness 3 - 4 mils (76 - 102 microns) per coat

Solids Content By Volume 44% +/- 2%

706 ft²/gal at 1.0 mils (17.3 m²/l at 25 microns)


Theoretical Coverage 235 ft²/gal at 3.0 mils (5.8 m²/l at 75 microns)
Rate 176 ft²/gal at 4.0 mils (4.3 m²/l at 100 microns)
Allow for loss in mixing and application.

As Supplied : 0.83 lb/gal (99 g/L)


VOC Values
VOC listed is per EPA Method 24 (calc). This is a nominal value and may vary slightly with color.

S U B S T R AT E S & S U R F A C E P R E PA R AT I O N
Remove any oil or grease from the surface to be coated with clean rags soaked in Carboline
General Thinner 2 or Surface Cleaner 3 (refer to Surface Cleaner 3 instructions) in accordance with SSPC-
SP1. Apply over clean, dry recommended primers only.

Steel Prime with suitable primer as recommended by your Carboline sales representative.

Concrete must be cured 28 days at 75°F (24°C) and 50% relative humidity or equivalent. Laitance,
form oils, curing agents and hardeners must be removed by suitable method before coating
Concrete or CMU application. Mortar joints should be thoroughly cured for a minimum of 15 days at 75°F (24°C) and
50% RH or equivalent. Seal or fill as needed with a suitable Sanitile filler/surfacer/sealer or other
appropriate primers.

Joint compound and plaster should be fully cured prior to coating application. Prime with Sanitile
Drywall & Plaster
120.

November 2019 S555 Page 1 of 3


®
Sanitile 555 VOC
PRODUCT DATA SHEET

MIXING & THINNING


Power mix base, then combine as follows:
1.25 Gallon Kit
Part A: 1 Gallon
Mixing Part B: 1 Quart
5 Gallon Kit
Part A: 4 Gallons
Part B: 1 Gallon

Thinning Not normally required. May be thinned up to 5% with clean potable water.

Ratio 4:1

2 hours at 75°F (24°C) and less at higher temperatures. Pot life viscosity remains fine for
Pot Life
approximately 4 hours after mixing; however there is a drop off in gloss after 2 hours.

A P P L I C AT I O N E Q U I P M E N T G U I D E L I N E S
Listed below are general equipment guidelines for the application of this product. Job site conditions may require modifications
to these guidelines to achieve the desired results.

Spray Application The following spray equipment has been found suitable and is available from manufacturers. Prior
(General) to use, flush all equipment with Thinner 21 followed by clean potable water.

Pressure pot equipped with dual regulators, 3/8” I.D. minimum material hose, with a maximum
Conventional Spray
length of 50’, 0.070” I.D. fluid tip and appropriate air cap.

Pump Ratio: 30:1 (minimum)


GPM Output: 3.0 (minimum)
Material Hose: 3/8” I.D. (minimum)
Airless Spray
Tip Size: 0.015-0.017”
Output PSI: 1600-2400
Filter Size: 60 mesh

Brush & Roller Multiple coats may be required to achieve desired dry film thickness and hiding characteristics.
(General)

Brush Use a synthetic bristle brush.

For smooth surfaces, use a short woven nap synthetic roller. For rough surfaces, cinder block or
Roller
very porous concrete, use a 3/8” woven nap synthetic roller.

A P P L I C AT I O N C O N D I T I O N S
Condition Material Surface Ambient Humidity
Minimum 50°F (10°C) 50°F (10°C) 50°F (10°C) 20%
Maximum 95°F (35°C) 110°F (43°C) 110°F (43°C) 90%

Do not apply when the surface temperature is less than 5°F (3°C) above the dew point. Do not apply if temperatures are
expected to drop below 50°F (10°C) within 24 hours of application. Special application techniques may be required above or
below normal application conditions.

November 2019 S555 Page 2 of 3


®
Sanitile 555 VOC
PRODUCT DATA SHEET

CURING SCHEDULE
Surface Temp. Dry to Handle Dry to Recoat Hard Cure
50°F (10°C) 10 Hours 12 Hours 36 Hours
75°F (24°C) 3 Hours 4 Hours 18 Hours
90°F (32°C) 2 Hours 3 Hours 12 Hours

These times are based on a 3.0-4.0 mil (75-100 microns) dry film thickness. Higher film thicknesses, insufficient ventilation, high
humidity or cooler temperatures will require longer cure times. *Fingernail hard or light foot traffic.

CLEANUP & SAFETY


Use clean potable water followed with suitable solvent to dry equipment. If partially dry use Thinner
Cleanup
#2. In case of spillage, absorb and dispose of in accordance with local applicable regulations.

Read and follow all caution statements on this product data sheet and on the SDS for this product.
Safety Employ normal workmanlike safety precautions. Use adequate ventilation. Keep container closed
when not in use.

PA C K A G I N G , H A N D L I N G & S T O R A G E
12 Months at 75°F
Shelf Life
Shelf Life: (actual stated shelf life) when kept at recommended storage conditions and in original
unopened containers.

Storage Temperature & 40° - 100°F


Humidity 0-90% Relative Humidity

Storage Store Indoors.

Shipping Weight 1.25 Gallon Kit - 13.75 Lbs. (6.3 kg)


(Approximate) 5 Gallon Kit - 55 Lbs. (25 kg)

Part A: >200°F
Flash Point (Setaflash)
Part B: >200°F

WA R R A N T Y
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject
to change without prior notice. User must contact Carboline Company to verify correctness before specifying or ordering. No
guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no
responsibility for coverage, performance, injuries or damages resulting from use. Carbolines sole obligation, if any, is to replace
or refund the purchase price of the Carboline product(s) proven to be defective, at Carbolines option. Carboline shall not be liable
for any loss or damage. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE, EXPRESS OR
IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. All of the trademarks referenced above are the property of Carboline International Corporation unless
otherwise indicated.

November 2019 S555 Page 3 of 3

You might also like