Nothing Special   »   [go: up one dir, main page]

Epilux 155

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

BERGER

P A I N T S
PROTECTIVE COATINGS
EPILUX 155
High Build Epoxy

PRODUCT
A high build modified amine adduct cured epoxy containing inert pigment that can be applied as an
DESCRIPTION intermediate or finish coat in aggressive conditions.
• Excellent resistance to fresh and salt water.
• Good solvent and chemical resistance.
• High film build in one coat.
• Low water permeability.
• Approved by the National Water Council for use in contract with potable water.

DESIGNED USE • High build epoxy for the protection of steel and concrete.
• Suitable for application to pipelines, harbour and shore installation, internal tank lining
Potable water, tanks, chemical plants.
• As a non toxic chemical resistant finish coat in food or chemical industries

PHYSICAL DATA VOLUME SOLIDS


(Based on ASTM D2697) 58% ± 2%
TYPICAL DRY FILM THICKNESS 125 microns
WET FILM THICKNESS 215 microns
5.80 m2/Ltr @ 100 microns dft
THEORETICAL COVERAGE
4.64 m2/Ltr @ 125 microns dft
COLOUR White, Grey
FINISH Low Sheen

APPLICATION METHOD OF APPLICATION :


DETAILS Airless Spray
This is the recommended method of application. Maximum 10% Thinner may be added.
Tip Size: 0.48 - 0.58 mm (0.019 - 0.023 in), Pressure: 110 - 160 kg/cm2 (1600 - 2300 psi)
Brush or Roller
May be used. However, additional coats may be required to achieve the recommended film
Thickness.
DRYING TIME:

substrate Touch dry Hard dry Recoating Interval Pot life


temp Minimum Maximum
15°C 10 Hrs 24 Hrs 32 Hrs 10 days 8 Hrs
25°C 8 Hrs 16 Hrs 16 Hrs 7 days 4 Hrs
35°C 6 Hrs 12 Hrs 12 Hrs 5 days 3 Hrs

NO. OF COMPONENTS Two


Mixing Ratio 3 parts Base to 1 part Hardener (by volume)
Do not apply this product if the Relative Humidity
Application Conditions Conditions exceeds 85% or if the substrate
temperature is within 3oC of the dew point.

Thinner / Cleaning solvent Solvalux 7-45 (Maximum 10% Addition in paint)

ADDITIONAL Storage Instruction Store in a cool shaded dry area


INFORMATION Flash Point Mixed 27°C

Packaging 5 Litres and 20 Litres

Shelf Life 12 Months

September 2018 Protective Coatings Sales & Service Bahrain 17123700 Fax 17730689
EPILUX 155
High Build Epoxy

SURFACE This product should be applied to a surface that has been blast cleaned and suitably primed (e.g.
with EPILUX Primers or ZINCANODE 600/690). The primer to be applied to a surface that has
PREPARATION been cleaned as follow:
• Remove all wax, oil and grease by solvent cleaning in accordance with the guidelines given by
SSPC-SP1.
• Where necessary remove weld spatter and round off all rough weld seams and sharp edges to a
smooth surface.
• Abrasive blast clean to a minimum standard of Sa 2 ½ Swedish Standard SIS 05 59 00 or ISO
8501-1:1988.
• Any surface defects revealed by blast cleaning should be ground, filled or treated in a suitable
manner.
• An average surface profile of 50 microns is acceptable but this average should not exceed 75
microns.
• After blasting, remove dust from the surface.
• The surface to be coated must be clean and dry.
• ALUMINIUM: Degrease and abrade with Solvalux 7-45 and wet-or-dry paper. Apply
LUXAPRIME 1500/Epiflex 1200.
• CONCRETE: Ensure that the surface is sound and matured. Remove laitance by through
wire brushing, acid etching or sweep blasting.
Blowholes and other defects should be filled with solvent less epoxy filler. EPILUX 155
may be applied directly to clean sound concrete provided the first coat is thinned by Upto
20%.

PRODUCT USE  As with all epoxy coating, this product will chalk on exposure to direct sunlight.
RESTRICTIONS  If Maximum Overcoating time is likely to be exceeded, apply a "tie coat".
 Dry heat resistance Upto 120oC

SAFETY  Avoid contact with the skin and eyes. Wear suitable protective clothing such as overalls,
PRECAUTIONS goggles, dust masks and gloves. Use a barrier cream.
 Ensure that there is adequate ventilation in the area where the product is being applied. Do not
breathe vapor or spray.
 This product is flammable. Keep away from sources of ignition. Do not smoke. Take
precautionary measures against static discharge. In case of fire – blanket flames with foam,
carbon dioxide or dry chemicals
 Refer to MSDS for further information.

FIRST AID  Eyes: In the event of accidental splashes, flush eyes with water immediately and obtain medical
advice
 Skin: Wash skin thoroughly with soap and water or approved industrial cleaner.
 DO NOT USE solvent or thinners.
 Inhalation: Remove to fresh air, loosen collar and keep patient rested.
 Ingestion: In case of accidental ingestion, DO NOT INDUCE VOMITING.
Obtain immediate medical attention

DISCLAIMER The information provided on this data sheet is not intended to be complete and is provided as general advice only. It is the responsibility
of the user to ensure that the product is suitable for the purpose for which he wishes to use it. As we have no control over the treatment
of the product, the standard of surface preparation of the substrate, or other factors affecting the use of this product, we are not responsible
for its performance nor would we accept any liability whatsoever or howsoever arising from the use of this product unless specifically agreed
to in writing by us. The information contained in this data sheet may be modified by us from time to time, and without notice, in the
light of our experience and continuous product development.

September 2018 Protective Coatings Sales & Service Bahrain 17123700 Fax 17730689