BATCHFLUX 5500 C Quick Start

Electromagnetic flowmeter for volumetric filling


machines

© KROHNE 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


CONTENTS BATCHFLUX 5500 C

1 Safety instructions 3

2 Installation 4

2.1 Scope of delivery............................................................................................................... 4


2.2 Device description ............................................................................................................ 5
2.3 Nameplate (example) ....................................................................................................... 6
2.4 Storage ............................................................................................................................. 7
2.5 Pre-installation requirements ......................................................................................... 7
2.6 General requirements ...................................................................................................... 8
2.6.1 Vibration .................................................................................................................................. 8
2.6.2 Magnetic field.......................................................................................................................... 8
2.7 Installation conditions ...................................................................................................... 9
2.7.1 Inlet and outlet ........................................................................................................................ 9
2.7.2 Open feed or discharge........................................................................................................... 9
2.7.3 Pump ..................................................................................................................................... 10
2.7.4 Control valve ......................................................................................................................... 10
2.7.5 Mounting position.................................................................................................................. 11
2.7.6 Mounting ............................................................................................................................... 12
2.7.7 Installation location .............................................................................................................. 12
2.7.8 Flange deviation .................................................................................................................... 12
2.7.9 Temperatures ....................................................................................................................... 13
2.7.10 Hot filling ............................................................................................................................. 13

3 Electrical connections 14

3.1 Safety instructions ......................................................................................................... 14


3.2 Grounding ....................................................................................................................... 14
3.3 Electrical connection...................................................................................................... 15
3.3.1 Cable connector M12 - 5 pin ................................................................................................. 15
3.3.2 Cable connector M12 - 8 pin (with status output) ................................................................ 16

4 Technical data 18

4.1 Dimensions and weights ................................................................................................ 18


4.2 Counter Flanges ............................................................................................................. 21

5 Notes 23

2 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C SAFETY INSTRUCTIONS 1

Warnings and symbols used


DANGER!
This information refers to the immediate danger when working with electricity.

DANGER!
These warnings must be observed without fail. Even partial disregard of this warning can lead to
serious health problems and even death. There is also the risk of seriously damaging the device
or parts of the operator's plant.

WARNING!
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.
There is also the risk of damaging the device or parts of the operator's plant.

CAUTION!
Disregarding these instructions can result in damage to the device or to parts of the operator's
plant.

INFORMATION!
These instructions contain important information for the handling of the device.

HANDLING
• This symbol designates all instructions for actions to be carried out by the operator in the
specified sequence.
i RESULT
This symbol refers to all important consequences of the previous actions.

Safety instructions for the operator


CAUTION!
Installation, assembly, start-up and maintenance may only be performed by appropriately
trained personnel. The regional occupational health and safety directives must always be
observed.

LEGAL NOTICE!
The responsibility as to the suitability and intended use of this device rests solely with the user.
The supplier assumes no responsibility in the event of improper use by the customer. Improper
installation and operation may lead to loss of warranty. In addition, the "Terms and Conditions of
Sale" apply which form the basis of the purchase contract.

INFORMATION!
• Further information can be found on the supplied CD-ROM in the manual, on the data sheet,
in special manuals, certificates and on the manufacturer's website.
• If you need to return the device to the manufacturer or supplier, please fill out the form
contained on the CD-ROM and send it with the device. Unfortunately, the manufacturer
cannot repair or inspect the device without the completed form.

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 3


2 INSTALLATION BATCHFLUX 5500 C

2.1 Scope of delivery


INFORMATION!
Inspect the packaging carefully for damages or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.

INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.

INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.

Figure 2-1: Scope of delivery


1 Flowmeter in ordered size
2 Product documentation (on request)

INFORMATION!
Assembly materials and tools are not part of the delivery. Use the assembly materials and tools
in compliance with the applicable occupational health and safety directives.

4 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C INSTALLATION 2

2.2 Device description


Your measuring device is supplied ready for operation. The factory settings for the operating
data have been made in accordance with your order specifications.

INFORMATION!
Product specific information and extensive product specification is available using PICK, the
Product Information Center KROHNE web-tool.
PICK can be found via the service menu button on the KROHNE.com website.

The following compact versions are available:


• Version 1: converter directly mounted on cast sensor housing in size DN2.5..6
• Version 2: converter and sensor in solid cast BNG construction for DN10 and DN 15
• Version 3: converter mounted on conventional sensor construction (DN25 and DN40)

Figure 2-2: Device version


1 DN2.5 - 4 - 6 ( 1/10 -1 /6 -1 /4 " ).
2 DN10 - DN15 ( 3/8 -1 /2 " ).
3 DN25 - DN40 ( 1 - 11 /2 " ).

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 5


2 INSTALLATION BATCHFLUX 5500 C

2.3 Nameplate (example)

Figure 2-3: Example of nameplate


1 Name and address of the manufacturer
2 Type designation, S/N nr and year of manufacturing
3 Calibration and device data
4 Tag number
5 Marking ( ao. CE and logo of certifications)
6 Electrical values and software revision nr.
7 Output data
8 Additional info ( e.g. manufacturer website)

6 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C INSTALLATION 2

2.4 Storage
• Store the device in a dry and dust-free location.
• Avoid lasting direct exposure to the sun.
• Store the device in its original packaging.
• Storage temperature: -50 ...+70°C / -58...+158°F

2.5 Pre-installation requirements


Make sure that you have all necessary tools available:
• Small wrench (M5) for connection to ground
• Torque wrench for installing flowmeter in pipeline
Always tighten the bolts uniformely and in diagonally opposite sequence !

Accessories necessary for the correct installation are available on request at the manufacturer

Make sure that these accesoires are available before starting installation;
• O-rings / L-ring gasket
• Special pipe flanges
• Stud bolts with lockwasher, plain washer and nut

INFORMATION!
To facilitate servicing and/or exchanging of the device, please note that:
it must be possible to shut off the flow through the pipeline ( control valve upstream in pipeline).
Drain the pipeline before removing device ( provide drain valve)

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 7


2 INSTALLATION BATCHFLUX 5500 C

2.6 General requirements


INFORMATION!
The following precautions must be taken to ensure a reliable installation.

• Make sure that there is adequate space to the sides.


• Protect the signal converter from direct sunlight and install a sun shade if necessary.
• Support the pipeline on both side of the flowmeter.
• Do not expose the signal converter to intense vibration. The flowmeters are tested for a
vibration level in accordance with IEC 60068-2-64.

2.6.1 Vibration

Figure 2-4: Avoid vibrations

2.6.2 Magnetic field

Figure 2-5: Avoid strong magnetic fileds

8 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C INSTALLATION 2

2.7 Installation conditions

Figure 2-6: Horizontal piperun

CAUTION!
Install in a slightly descending pipe section to prevent air from collecting and to avoid faulty
measurements (meter can drain).

2.7.1 Inlet and outlet

Figure 2-7: Inlet and outlet section


1 ≥ 5 DN
2 ≥ 2 DN
3 Drain valve (to empty pipeline)

2.7.2 Open feed or discharge

Figure 2-8: Installation in front of an open discharge

∠α > 2°
1 Drain valve (to empty pipeline)

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 9


2 INSTALLATION BATCHFLUX 5500 C

2.7.3 Pump

Figure 2-9: Installation behind a pump

2.7.4 Control valve

Figure 2-10: Installation in front of a control valve

∠α > 2°
1 Drain valve (to empty pipeline)

10 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C INSTALLATION 2

2.7.5 Mounting position

Figure 2-11: Installation in bending pipes

∠α > 2°
1 Drain valve (to empty pipeline)

CAUTION!
To ensure a correct measurement, avoid draining or partial filling of the flow sensor during
operation.

WARNING!
Vertical down position only in conjunction of a control valve

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 11


2 INSTALLATION BATCHFLUX 5500 C

2.7.6 Mounting
2.7.7 Installation location

Figure 2-12: Horizontal installation

CAUTION!
Mount the flow sensor in such a way that the electrode axis
(X--------X) is approximately in a horizontal pipe run.

2.7.8 Flange deviation

Figure 2-13: Mounting position and flange deviation


1 Lmax
2 Lmin

CAUTION!
Max. permissible deviation of pipe flange faces:
Lmax - Lmin ≤ 0.5 mm / 0.02"

12 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C INSTALLATION 2

2.7.9 Temperatures

Process temperature vs ambient temperature

1 Ambient temperature
2 Process temperature

2.7.10 Hot filling

Installation position

Figure 2-14: In case of hot fluids

INFORMATION!
Avoid installation near hot product tanks. If possible, try to insulate the flowmeter from radiant
heat sources.

CAUTION!
On high temperature pipes and where temperatures exceed 100°C / 212°F, provide facilities to
compensate for longditudinal expansion of pipeline (due to heat-up). Use flexible pipe elements
(e.g. elbows).

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 13


3 ELECTRICAL CONNECTIONS BATCHFLUX 5500 C

3.1 Safety instructions


DANGER!
All work on the electrical connections may only be carried out with the power disconnected. Take
note of the voltage data on the nameplate!

DANGER!
Observe the national regulations for electrical installations!

DANGER!
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex
documentation.

WARNING!
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.

INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.

3.2 Grounding

CAUTION!
The grounding should not transmit any interference voltage. Therefore do not ground any other
electrical device at the same conductor.

CAUTION!
When connecting to functional extra-low voltages (24VDC) , ensure that you use protective
separation (PELV) according to IEC 364/IEC 536 or VDE 0100/VDE 0106.

CAUTION!
Do not remove the secured (glued) adjusting screw. Removing the screw will affect the gas
tightness and durability of the device.

14 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C ELECTRICAL CONNECTIONS 3

3.3 Electrical connection


3.3.1 Cable connector M12 - 5 pin
All the operating data are preset at the factory. For changing the parameters and diagnostic
purposes BATCHMon plus operation software can be used.

1 +24 VDC
2 Frequency output
3 Frequency output (ground)
4 Ground
5 To be connected for servicing only

Note; the switch circuits have a resistance of approximately 76 Ohms

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 15


3 ELECTRICAL CONNECTIONS BATCHFLUX 5500 C

3.3.2 Cable connector M12 - 8 pin (with status output)


The 8 pin electric connection has a status output. This status output, is configurable to customer
specifications and offers either the flow direction (of the medium) or an error signal.

1 + 24 VDC
2 Not Connected
3 To be connected for servicing only
4 Ground
5 Frequency output
6 Ground common I/O
7 Status output
8 Not Connected

Options on status output 7; Off / Error / Flow direction

Note; the switch circuits have a resistance of approximately 76 Ohms

16 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C ELECTRICAL CONNECTIONS 3

Mode
• Status output On / Off
• Flow direction

- Default value :Flow Direction


- Forward flow : status output; open
- Reversed flow ; status output ; closed

• Error software / application failure

Error signaling for following events: software failure or application failure (detection of empty
pipe only).No error ; status output open

Use one of the following attachment plug types to connect the flowmeter to a third
party system:
• moulded plug, straight or angle-entry form
• integrally extruded plug with cable in various lengths
• moulded plug, straight form, especially suitable for high-interference environments

Possible vendors of these plugs are:


• Binder
• Hirschmann
• Lumberg
• Amphenol
• Coninvers

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 17


4 TECHNICAL DATA BATCHFLUX 5500 C

4.1 Dimensions and weights


DN2.5...6

Figure 4-1: Dimensions


1 (Grounding)
2 M12; 5 - 8 pins connector

Nominal Dimensions [mm] Weight


size [kg]
a b c d e f g h i
DN2.5 50 156 206 6 → 2.5 44 88 141 128 54 1.5
DN4 50 156 206 7 → 3.2 44 88 141 128 54 1.6
DN6 50 156 206 9 → 4.8 44 88 141 128 54 1.6
Note on dimension d: As the diameter reduces to the middle, the diameter is specified for the inlet and
for the middle

Nominal Dimensions [inches] Weight


size [lb]
a b c d e f g h i
1/10" 1.97 6.14 8.11 0.24 → 0.10 1.73 3.46 5.55 5.0 2.13 3.4
1/6" 1.97 6.14 8.11 0.28 → 0.13 1.73 3.46 5.55 5.0 2.13 3.6
1/4" 1.97 6.14 8.11 0.35 → 0.19 1.73 3.46 5.55 5.0 2.13 3.6
Note on dimension d: As the diameter reduces to the middle, the diameter is specified for the inlet and
for the middle

18 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C TECHNICAL DATA 4

DN10...15

1 (Grounding)
2 M12; 5 - 8 pins connector

Nominal Dimensions [mm] Weight


size [kg]
a b c d e f g h i
DN10 50 140 179 10.5 → 8 45.4 60 106.5 88 54 1.4
DN15 50 140 179 14 → 12 45.4 60 106.5 88 54 1.4
Note on dimension d: As the diameter reduces to the middle, the diameter is specified for the inlet and
for the middle

Nominal Dimensions [inches] Weight


size [lb]
a b c d e f g h i
3/8" 1.97 5.51 7.05 0.41 → 0.31 1.79 2.36 4.19 3.46 2.13 3.1
1/2" 1.97 5.51 7.05 0.55 → 0.47 1.79 2.36 4.19 3.46 2.13 3.1
Note on dimension d: As the diameter reduces to the middle, the diameter is specified for the inlet and
for the middle

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 19


4 TECHNICAL DATA BATCHFLUX 5500 C

DN25..40

Figure 4-2: Dimensions


1 (Grounding)
2 M12; 5 - 8 pins connector

Nominal Dimensions [mm] Weight [kg]


size
a b c d e f g h i
DN25 50 170 204 26 → 20 68 102 141 128 58 1.6
DN40 50 177 219 39 → 30 84 117 141 128 83 2.3
Note on dimension d: As the diameter reduces to the middle, the diameter is specified for the inlet and
for the middle

Nominal Dimensions [inches] Weight [lb]


size
a b c d e f g h i
1" 1.97 6.69 8.03 1.02 → 0.79 2.68 4.02 5.55 5.04 2.28 3.6
1 1/2" 1.97 6.97 8.62 1.54 → 1.18 3.30 4.61 5.55 5.04 3.27 5.1
Note on dimension d: As the diameter reduces to the middle, the diameter is specified for the inlet and
for the middle

20 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C TECHNICAL DATA 4

4.2 Counter Flanges


The BATCHFLUX 5500 must be mounted between counter flanges (as shown in the following
drawing), to ensure that the device works correctly.

Sizes of flanges
DN a [mm] b [mm] c [mm] d [mm] O-ring
Flange 1 2,5...10 * see table * see table * see table Ø 30.4 Special L-ring
below below below
Flange 2 15 Ø 14.2 Ø 19.2 Ø 26.6 Ø 30.4 15.47 * 3.53
Flange 3 25 Ø 25 Ø 31.3 Ø 41.2 Ø 49.2 15.47 * 3.53

Size DN a1[mm] a2 [mm] b [mm] c [mm]


2,5 Ø 10 Ø 6.2 Ø 11.1 Ø 18.4
4 Ø 10 Ø 7.2 Ø 12.1 Ø 19.4
6 Ø 10 Ø 9.2 Ø 14.2 Ø 21.5
10 Ø 10 Ø 10.7 Ø 15.7 Ø 23

Note; flanges must be fully welded and surface roughness, grinded and polished ( roughness
0,8). See for more information the 3A CCE 2007-2 Coordination Bulletin.

INFORMATION!
The O-rings require periodic inspection and replacement. As the interval depends on process-
specific variables, the length of the interval cannot be specified.
The O-rings are not part of the manufacturer portfolio.

INFORMATION!
For 3A applications, O-rings must conform to the requirements of the 3A sanitary standard for
Flow meters, number 28-04 Class I or Class II (max. 8% milk fat).
The used O-rings must also withstand the processing, sterilization and chemical conditions for
the intended use ( for more information, contact the manufacturer)

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 21


4 TECHNICAL DATA BATCHFLUX 5500 C

Reference to specific dimensions and drawing numbers


Size DN Pcd [mm] D [mm] W [mm] Drawing number
2,5 Ø 56 Ø 68 14.5 4000587801
4 Ø 56 Ø 68 14.5 4000587807
6 Ø 56 Ø 68 14.5 4000587810
10 Ø 56 Ø 68 14.5 4000587815
15 Ø 56 Ø 68 14.9 4000587818
25 Ø 84 Ø 104 16.5 4000587824
40 # # # #

# Dimensions for DN40; on request

INFORMATION!
Detailed construction drawings of the above sketches are available from the manufacturer
website (see table for drawing numbers)

22 www.krohne.com 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en


BATCHFLUX 5500 C NOTES 5

12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en www.krohne.com 23


KROHNE – Process instrumentation and measurement solutions
• Flow
• Level
• Temperature
© KROHNE 12/2016 - 4003386302 - QS BATCHFLUX 5500 R04 en - Subject to change without notice.

• Pressure
• Process Analysis
• Services

Head Office KROHNE Messtechnik GmbH


Ludwig-Krohne-Str. 5
47058 Duisburg (Germany)
Tel.: +49 203 301 0
Fax: +49 203 301 10389
info@krohne.com
The current list of all KROHNE contacts and addresses can be found at:
www.krohne.com

You might also like