DANGER!
These warnings must be observed without fail. Even partial disregard of this warning can lead to
serious health problems and even death. There is also the risk of seriously damaging the device
or parts of the operator's plant.
WARNING!
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.
There is also the risk of damaging the device or parts of the operator's plant.
CAUTION!
Disregarding these instructions can result in damage to the device or to parts of the operator's
plant.
INFORMATION!
These instructions contain important information for the handling of the device.
HANDLING
• This symbol designates all instructions for actions to be carried out by the operator in the
specified sequence.
i RESULT
This symbol refers to all important consequences of the previous actions.
LEGAL NOTICE!
The responsibility as to the suitability and intended use of this device rests solely with the user.
The supplier assumes no responsibility in the event of improper use by the customer. Improper
installation and operation may lead to loss of warranty. In addition, the "Terms and Conditions of
Sale" apply which form the basis of the purchase contract.
INFORMATION!
• Further information can be found on the supplied CD-ROM in the manual, on the data sheet,
in special manuals, certificates and on the manufacturer's website.
• If you need to return the device to the manufacturer or supplier, please fill out the form
contained on the CD-ROM and send it with the device. Unfortunately, the manufacturer
cannot repair or inspect the device without the completed form.
INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
INFORMATION!
Assembly materials and tools are not part of the delivery. Use the assembly materials and tools
in compliance with the applicable occupational health and safety directives.
INFORMATION!
Product specific information and extensive product specification is available using PICK, the
Product Information Center KROHNE web-tool.
PICK can be found via the service menu button on the KROHNE.com website.
2.4 Storage
• Store the device in a dry and dust-free location.
• Avoid lasting direct exposure to the sun.
• Store the device in its original packaging.
• Storage temperature: -50 ...+70°C / -58...+158°F
Accessories necessary for the correct installation are available on request at the manufacturer
Make sure that these accesoires are available before starting installation;
• O-rings / L-ring gasket
• Special pipe flanges
• Stud bolts with lockwasher, plain washer and nut
INFORMATION!
To facilitate servicing and/or exchanging of the device, please note that:
it must be possible to shut off the flow through the pipeline ( control valve upstream in pipeline).
Drain the pipeline before removing device ( provide drain valve)
2.6.1 Vibration
CAUTION!
Install in a slightly descending pipe section to prevent air from collecting and to avoid faulty
measurements (meter can drain).
∠α > 2°
1 Drain valve (to empty pipeline)
2.7.3 Pump
∠α > 2°
1 Drain valve (to empty pipeline)
∠α > 2°
1 Drain valve (to empty pipeline)
CAUTION!
To ensure a correct measurement, avoid draining or partial filling of the flow sensor during
operation.
WARNING!
Vertical down position only in conjunction of a control valve
2.7.6 Mounting
2.7.7 Installation location
CAUTION!
Mount the flow sensor in such a way that the electrode axis
(X--------X) is approximately in a horizontal pipe run.
CAUTION!
Max. permissible deviation of pipe flange faces:
Lmax - Lmin ≤ 0.5 mm / 0.02"
2.7.9 Temperatures
1 Ambient temperature
2 Process temperature
Installation position
INFORMATION!
Avoid installation near hot product tanks. If possible, try to insulate the flowmeter from radiant
heat sources.
CAUTION!
On high temperature pipes and where temperatures exceed 100°C / 212°F, provide facilities to
compensate for longditudinal expansion of pipeline (due to heat-up). Use flexible pipe elements
(e.g. elbows).
DANGER!
Observe the national regulations for electrical installations!
DANGER!
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex
documentation.
WARNING!
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
3.2 Grounding
CAUTION!
The grounding should not transmit any interference voltage. Therefore do not ground any other
electrical device at the same conductor.
CAUTION!
When connecting to functional extra-low voltages (24VDC) , ensure that you use protective
separation (PELV) according to IEC 364/IEC 536 or VDE 0100/VDE 0106.
CAUTION!
Do not remove the secured (glued) adjusting screw. Removing the screw will affect the gas
tightness and durability of the device.
1 +24 VDC
2 Frequency output
3 Frequency output (ground)
4 Ground
5 To be connected for servicing only
1 + 24 VDC
2 Not Connected
3 To be connected for servicing only
4 Ground
5 Frequency output
6 Ground common I/O
7 Status output
8 Not Connected
Mode
• Status output On / Off
• Flow direction
Error signaling for following events: software failure or application failure (detection of empty
pipe only).No error ; status output open
Use one of the following attachment plug types to connect the flowmeter to a third
party system:
• moulded plug, straight or angle-entry form
• integrally extruded plug with cable in various lengths
• moulded plug, straight form, especially suitable for high-interference environments
DN10...15
1 (Grounding)
2 M12; 5 - 8 pins connector
DN25..40
Sizes of flanges
DN a [mm] b [mm] c [mm] d [mm] O-ring
Flange 1 2,5...10 * see table * see table * see table Ø 30.4 Special L-ring
below below below
Flange 2 15 Ø 14.2 Ø 19.2 Ø 26.6 Ø 30.4 15.47 * 3.53
Flange 3 25 Ø 25 Ø 31.3 Ø 41.2 Ø 49.2 15.47 * 3.53
Note; flanges must be fully welded and surface roughness, grinded and polished ( roughness
0,8). See for more information the 3A CCE 2007-2 Coordination Bulletin.
INFORMATION!
The O-rings require periodic inspection and replacement. As the interval depends on process-
specific variables, the length of the interval cannot be specified.
The O-rings are not part of the manufacturer portfolio.
INFORMATION!
For 3A applications, O-rings must conform to the requirements of the 3A sanitary standard for
Flow meters, number 28-04 Class I or Class II (max. 8% milk fat).
The used O-rings must also withstand the processing, sterilization and chemical conditions for
the intended use ( for more information, contact the manufacturer)
INFORMATION!
Detailed construction drawings of the above sketches are available from the manufacturer
website (see table for drawing numbers)