GEFRAN AGL 50 Drive wiring for OMKAR Controller

Incoming Power & Earth Braking Resistor (DBR)


U1 / L1 Incoming Power - R Phase 4kW Drive : 100 Ohms, 750 Watts
U2 / L2 Incoming Power - Y Phase 5.5kW Drive : 68 Ohms, 750 Watts
U3 / L3 Incoming Power - B Phase 7.5kW Drive : 68 Ohms, 1000 Watts
PE1 Earth from Incoming Power Braking Resistor (DBR) connection in Drive : BR1, C

Motor Power & Earth


U2 / T1 Motor Power - R Phase
V2 / T2 Motor Power - Y Phase
W2 / T3 Motor Power - B Phase
PE2 Motor Earth

Control Wires
Terminal
Wire Ferrule Description
Number
12 BB Safety Input
14 UP UP Command
16 DOWN DOWN Command
18 S1 Slow Speed
20 S2 High Speed
22 DARD
24
Loop
26
28 COM Drive Common
11
Direction Change Over Output in ARD Mode (Transistor O/P)
13
21 M12 / GND
Brake Release Output (Relay)
23 DBK
25 M12 / GND
Drive Run Output (Relay)
27 RKM

3 Phase Power Supply Input Terminals - L1, L2, L3

d.000 Menu of read-only parameters (display)

S.000 Menu of basic drive start up parameters

I.000 Menu of input/output drive settings

F.000 Menu of multi frequencies and


ramps settings

P.000 Menu of read/write drive parameters

A.000 Menu of Function Blocks

C.000 Menu of control-type


parameters (Save, Load default, etc.)
Motor Power Connection DBR Connection
Terminals - U2, V2, W2 Terminals - BR1, C

JJ Kings Automation
Authorised GEFRAN Drive Distributor
GEFRAN AGL50 Drive Parameters for OMKAR Controller Contact: 9381053454
Rev-0 dated 11-11-2014 PAGE 1 of 2 E-mail: jjkings.automation@yahoo.com
GEFRAN AGL 50 Parameters for OMKAR Controller
Sl.No. PARAMETERS Default Value Set Value PARAMETER DESCRIPTION
Parameter Access
P.998 2 3 Parameter protection code
P.999 0 3 All parameter access level
P.281 75 100 / 68 Ohmic Value Of Braking Resistor
P.282 0.03 0.75 / 1.00 Braking Resistor Power in kW
P.341 0.0 8.0 Max Powerloss Time
P.580 8 1 Output Frequency Display at start up

Input & Output Parameters


I.000 2 2 Drive Enable.
I.005 7 0 Dig Input 6 Configuration
I.011 0 7 ARD Mode Configuration in Dig Input 6 (Terminal 22)
I.101 54 54 Brake Release Output (Terminal 21 & 23)
I.102 2 51 Drive Run Output (Terminal 25 & 27)
F.115 5.0 Hz 6.0 Hz Set ARD Frequency
Motor Parameters & Tuning
S.100 380 Motor Rated Voltage Set Motor voltage from motor nameplate
S.101 50 Motor Rated Frequency Set Motor frequency from motor nameplate
S.150 9.2 Motor Rated Current Set Motor current from motor nameplate
S.151 2 Motor Pole Pairs Set Motor poles from motor nameplate
S.152 0.8 Motor Power Factor Set Motor power factor (COS Ø) from motor nameplate

* In OMKAR Controller switch ON Inspection Mode.


* In V3F DRIVE Press enter key , then Display show 'off' then press up
arrow Key then display show 'do' then Press again enter Key after that
display show 'tunn' ,
* with in 5 Seconds press & hold Inspection UP Button in OMKAR
S.170 off Motor Tuning
Controller then display show 'runn'. And wait till display show 'done' .
* Then release the Inspection UP Button in OMKAR Controller, after
that Tuning is completed.
* Then save these parameters in V3F DRIVE.
* for SAVE please follow the procedure given in C.000

Setting Parameters
S.180 0.50 0.65 - 1.00 Enter Car Travel Speed(m/Sec)
S.200 10.0 Hz 0.0 Hz Multi Speed-0
S.201 50.0 Hz 7.0 Hz Multi Speed-1 (Slow Speed)
S.202 0.0 Hz 40.0 Hz Multi Speed-2 (High Speed)
S.203 0.0 Hz 15.0 Hz Multi Speed-3 (Inspection Speed)
S.204 0.0 Hz 0.0 Hz Multi Speed-4
S.225 1.00 0.80 Acc/Dec factor
S.230 0.50 0.30 Accc initial jerk
S.231 0.60 0.60 Acceleration
S.234 0.60 0.60 Deceleration
S.251 1.00 0.70 Magnetic time
S.254 1.00 1.00 Dc Brake stop time
S.260 1 0 Lift stop mode
S.301 0 1 Auto boost
Saving Parameters
Press enter key , then display show 'off' then
C.000 off save parameter press up key display show 'do' then again press
enter key then display show 'done' ,save is done
Display Parameters
d.000 Motor Frequency
d.002 Motor Current