Nothing Special   »   [go: up one dir, main page]

BITUFLAME P 4180, P 4200 & P 4260: - Description

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

BITUFLAME P 4180, P 4200 & P 4260

APP MODIFIED – POLYESTER REINFORCED – TORCH APPLIED

• DESCRIPTION
Bituflame range of modified bitumen waterproofing membranes are manufactured from a rich
mixture of bitumen and selected polymers blended together to obtain excellent heat resistance, UV
resistance and cold temperature flexibility. Polymerized bitumen then coated onto a dimensionally
stable non woven polyester carrier to obtain excellent tensile strength, tear and puncture resistance.

• USES
Bituflame is used as waterproofing/damproofing membrane for protection of various substrates in
wide range of applications.

• INSTRUCTION FOR APPLICATION


Application procedure may vary depending upon site conditions. General application guideline is
given below.

Priming
Apply Bitukote Bitumen Primer to a clean, smooth and dry surface by brush, roller or spray. Refer
primer data sheet for more details.

Alignment
Unroll and align Bituflame and re roll correctly before torching. Overlap should be 8 to 10mm and
end lap should be 100 to 150mm.

Torching
Use gas burner to heat substrate and underside of Bituflame. Embossing on the lower face of the
membrane allows a fast and safe laying. When embossing disappears, after torching, the
membrane is ready to stick. Roll forward and press firmly against the substrate to bond.

Sealing
Heat both the overlaps and use round tipped trowel to seal the overlap. Excess compound should
be smoothened and pressed into seam using hot trowel.

Upstand
All angles and abutments should be sealed with extra care to ensure full bondage. Seal the edges
well into the grooves and protect with Bitumastic or Polysulphide sealant.
BITUFLAME P 4180, P 4200 & P 4260
APP MODIFIED – POLYESTER REINFORCED – TORCH APPLIED

• STORAGE
Bituflame should be stored vertically in clean covered area. Rolls should not be stacked.

• HEALTH & SAFETY


All safety measures should be observed during application. Fire extinguishers should be available at site.
Care should be taken with gas and torch should not be rested on finished surface or on any materials
that can be scorched by flame or hot torch. Protective tools, such as gloves and goggles should be
worn by all workers during application.

BITUFLAME MEMBRANES P4180, P4200& P4260


TECHNICAL DATA
PROPERTIES VALUES TEST METHOD
P4180 P4200 P4260
Roll Size – m 10 X 1 10 X 1 10 x 1
Thickness – mm 4.0 4.0 4.0
Unit weight – Kg/m2 4.0-4.20 4.0-4.20 4.0-4.20 UEAtc
Carrier (polyester) weight g/m2 180 200 260 UEAtc
Coating Asphalt Polymer modified asphalt
Softening Point (R&B) oC 150 ASTM D 36
Penetration at 25oC, 0.1mm 15 – 25 ASTM D 5
Tensile Strength (L/T), N/5cm 800/600 850/650 1100/800 UEAtc
Elongation at break (L.T), % 40/50 40/50 40/50 UEAtc
32,000/ 34,000/ 49,500/ CGSB-37 GP 56M
Load strain product (L/T) N
30,000 32,000 40,000
Lap Joint Strength (L/T), N/5cm >800/600 >850/650 >1100/800 UEAtc
Tear Resistance (L/T), N 180/200 200/220 220/240 UEAtc
Static : L4
Puncture resistance UEAtc
Dynamic : L3
Resistance leakage at joints Pass UEAtc
Resistance to water pressure No Leakage DIN 52123
Water absorption, % (BSP) <0.15 ASTM D 5147
Heat resistance at 100oC No flow UEAtc
Resistance to aging after 2000 hrs
No deterioration ASTM D 4799
(Weather-O-Meter)
Tolerance according standards 5 – 20% 04-05

Quality Products since 1994

Manufactured by
GULF MEMBRANE & COATING INDUSTRIES WLL
P.O. Box 10266, Manama, Kingdom of Bahrain
Tel : +973 17 770019, Fax : +973 17 774450
Web site : www.gmcibahrain.com