Electrical Contractor News and Updates: Newsletter No. 12 JANUARY 2010
Electrical Contractor News and Updates: Newsletter No. 12 JANUARY 2010
Electrical Contractor News and Updates: Newsletter No. 12 JANUARY 2010
This newsletter is produced by Bruce Blacker of Insight Electrical Consulting & Training Pty Ltd to inform and aid the electrical contracting industry. All information contained in this newsletter to be taken as a guide only and should be verified prior to its implementation or use.
Welcome
Through this newsletter I will attempt to keep you all up to date with the major issues which affect you. If you have any comment or suggestions in regards to this newsletter please pass them onto me so that the information contained in this publication remains both informative and suits your needs.
Contents
The following articles appear in this newsletter: Happy New Year AS/NZS 3000 Wiring Rules Amendments AS/NZS 3000 Wiring Rules Frequently Asked Questions Revised and Updated Australian Standards Level 2 Service Provider Courses
Page 1 of 5
Page 2 of 5
Table 3.7 The heading to the third column of this table has been altered. This now shows that the requirement of separation of the earthing stake is only to conductive underground services such as water pipes, etc and not to all types of under services. Clause 5.3.3.2 The clause has been altered to state that the largest size main earthing conductor to an earth stake is not required to be any larger than 120mm2. Table 5.2 This table now allows 25mm2 bare copper conductor to be used as a strip electrode. Clause 5.6.2.5 This clause has been altered to state clearly that the requirement for the bonding of the concrete steel reinforcing needs only be to any part of the earthing system. Clause 6.3.1 This clause has been altered to bring areas of natural water to be treated the same as a swimming pool area. Table 8.2 This table has been revised. Some of the resistances have been lowered. Tables C9, C10 and C11 Tables for number of cables in conduits have been reviewed. Appendix K This appendix has been deleted as a separate standard for high voltage installations now exists.
Clarification of the requirements for mechanical protection. Spacing of underground services. Clarification on the requirements for equipotential bonding of steel reinforcing in showers and bathrooms.
If you are interested in attending a Level 2 Service Provider course in the Albury area please contact me with details, etc. If I can get enough people interested this course will be arranged. Please note that there will be no obligation to attend just by supplying me with an expression of interest. If you feel there is enough interest to run these courses in other areas please contact me to discuss further.
Final Comments
Insight Electrical Consulting & Training Pty Ltd is still available to help in many areas including; liaison with supply authorities, technical advice, interpretation of defects and Wiring Rules, switchboard specification and design, single line diagrams, electrical designs, etc. If you have any areas which you need assistance just give us a call and I will help you out. Insight Electrical Consulting & Training Pty Ltd is able to specify switchboards and source prices from a number of switchboard manufacturers. All comments in this newsletter are those of Insight Electrical Consulting & Training Pty Ltd and clarifications may be required before this information is used for general work.
Page 5 of 5