Bvm-20f1u/20f1e Bvm-20e1u/20e1e Bvm-14f1u/14f1e Bvm-14e1u/14e1e Bvm-14f5u/14f5e Bvm-14e5u/14e5e
Bvm-20f1u/20f1e Bvm-20e1u/20e1e Bvm-14f1u/14f1e Bvm-14e1u/14e1e Bvm-14f5u/14f5e Bvm-14e5u/14e5e
Bvm-20f1u/20f1e Bvm-20e1u/20e1e Bvm-14f1u/14f1e Bvm-14e1u/14e1e Bvm-14f5u/14f5e Bvm-14e5u/14e5e
BVM-20F1U/20F1E
BVM-20E1U/20E1E
BVM-14F1U/14F1E
BVM-14E1U/14E1E
BVM-14F5U/14F5E
BVM-14E5U/14E5E
ATTENTION
To avoid electrical shock, do not open the
Il y a un risque d’explosion si la pile est mal insérée.
cabinet. Refer servicing to qualified Remplacer la pile uniquement par une pile de même type ou
personnel only. de type équivalent recommandé par le fabricant. Jeter les
piles usées conformément aux instructions du fabricant.
AVERTISSEMENT
Afin d’éviter tout risque d’incendie ou d’électrocution, ne pas VORSICHT:
exposer cet appareil à la pluie ou à l’humidité. Es besteht Explosionsgefahr, wenn die Batterie inkorrekt
eingelegt wird.
Afin d’écarter tout risque d’électrocution, garder le coffret Es darf nur eine identische oder eine vom Hersteller
fermé. Ne confier l’entretien de l’appareil qu’à un personnel empfohlene Batterie des gleichen Typs eingesetzt werden.
qualifié. Entladene Batterien sind nach den Anweisungen des
Herstellers zu entsorgen.
PRECAUCION
WARNUNG Peligro de explosión en caso de haberse instalado
Um Feuergefahr und die Gefahr eines elektrischen SchIages incorrectamente la betería.
zu vermeiden, darf das Gerät weder Regen noch Cambie sólo por una del mismo tipo o especificaciones
Feuchtigkeit ausgesetzt werden. equivalentes, de entre las recomendadas por el fabricante.
Las baterías viejas se deben eliminar siguiendo las
Um einen elektrischen Schlag zu vermeiden, darf das instrucciones del fabricante.
Gehäuse nicht geöffnet werden. Überlassen Sie
Wartungsarbeiten stets nur einem Fachmann. ATTENZIONE:
Pericolo di esplosione se la pila viene sostituita
scorrettamente.
ADVERTENCIA Sostituirla solo con un’altra uguale o di un tipo equivalente
Para evitar incendios o el riesgo de electrocución, no consigliato dal fabbricante. Gettare via le pile usate secondo
exponga la unidad a la lluvia ni a la humedad. le istruzioni del fabbricante.
Remarque
ATTENZIONE La prise doit être près de l’appareil et facile d’accès.
Per evitare incendi o cortocircuiti, l’apparecchio non deve
essere esposto alla pioggia o all’umidità. Hinweis
Zur Trennung vom Netz ist der Netzstecker aus der
Per evitare scosse elettriche, non aprite l’apparecchio. Per Steckdose zu ziehen, welche sich in der Nähe des Gerätes
le riparazioni rivolgetevi solo a personale qualificato. befinden muß und leicht zugänglich sein soll.
Nota
La toma mural debe estar instalada cerca del equipo y debe
accederse a ésta con facilidad.
Nota
La presa di corrente deve essere situata vicino
all’apparecchio e deve essere facilmente accessibile.
WARNING: THIS WARNING IS APPLICABLE FOR USA Note
ONLY. Be sure to use the supplied power cord for this monitor, or
this monitor may not conform with the FCC Rules or EEC
If used in USA, use the UL LISTED power cord specified Directive 89/336/EEC.
below.
DO NOT USE ANY OTHER POWER CORD. Remarque
Utiliser le cordon d’alimentation fourni pour ce moniteur,
Plug Cap Parallel blade with ground pin sinon il pourrait ne pas être conforme aux règles FCC ou à la
(NEMA 5-15P Configuration) directive CEE 89/336/EEC.
Cord Type SVT, three 16 or 18 AWG wires
Length Less than 2.5 m (8 ft 3 in) Hinweis
Rating Minimum 10 A, 125 V Dieser Monitor darf ausschließlich mit dem mitgelieferten
Netzkabel betrieben werden, weil anderenfalls der Monitor
Using this unit at a voltage other than 120V may require the nicht mehr die FCC-Vorschriften oder die EG-Richtlinie 89/
use of a different line cord or attachment plug, or both. To 336/EWG erfüllt.
reduce the risk of fire or electric shock, refer servicing to
qualified service personnel. Nota
Utilice sin falta el cable eléctrico que viene con este monitor;
de lo contrario el monitor puede no cumplir con los
For customers in the USA reglamentos de la FCC o de la directiva 89/336/EEC de la
This equipment has been tested and found to comply with Comunidad Europea.
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide Nota
reasonable protection against harmful interference when the Assicurarsi di usare il cavo di alimentazione in dotazione per
equipment is operated in a commercial environment. This questo monitor, altrimenti il monitor può non essere
equipment generates, uses, and can radiate radio frequency conforme alle norme FCC o alla Direttiva CEE/89/336.
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio For the customers in the United Kingdom
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the WARNING
user will be required to correct the interference at his own THIS APPARATUS MUST BE EARTHED
expense.
IMPORTANT
You are cautioned that any changes or modifications not The wires in this mains lead are coloured in accordance with
expressly approved in this manual could void your authority the following code:
to operate this equipment. Green-and-yellow: Earth
Blue: Neutral
The shielded interface cable recommended in this manual Brown: Live
must be used with this equipment in order to comply with the As the colours of the wires in the mains lead of this
limits for a digital device pursuant to Subpart B of Part 15 of apparatus may not correspond with the coloured markings
FCC Rules. identifying the terminals in your plug proceed as follows:
The wire which is coloured green-and-yellow must be
Voor de klanten in Nederland connected to the terminal in the plug which is marked by the
letter E or by the safety earth symbol Y or coloured green or
green-and-yellow.
The wire which is coloured blue must be connected to the
terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the
• Dit apparaat bevat een vast ingebouwde batterij die niet terminal which is marked with the letter L or coloured red.
vervangen hoeft te worden tijdens de levensduur van het Ensure that your equipment is connected correctly - if you
apparaat. are in any doubt consult a qualified electrician.
• Raadpleeg uw leverancier indien de batterij toch vervangen
moet worden.
De batterij mag alleen vervangen worden door
vakbekwaam servicepersoneel.
• Gooi de batterij niet weg maar lever deze in als klein
chemisch afval (KCA).
• Lever het apparaat aan het einde van de levensduur in voor
recycling, de batterij zal dan op correcte wijze verwerkt
worden.
For the customers in Europe
This product with the CE marking complies with both the
EMC Directive (89/336/EEC) and the Low Voltage Directive
(73/23/EEC) issued by the Commission of the European
Community.
Compliance with these directives implies conformity to the
following European standards:
• EN60950: Product Safety
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors) and E4 (controlled EMC environment, ex.
TV studio).
Precaution.................................................................................................. 3
Chapter 1 Overview
Overview .................................................................................................... 4
Features ............................................................................................... 4
Options ................................................................................................ 5
Connector Panel Configuration ........................................................... 7
Location and Function of Parts ............................................................... 9
Front Panel .......................................................................................... 9
Rear Panel ......................................................................................... 15
1
Table of Contents
2
Precaution
Chapter 1 Overview
On safety On repacking
• Operate the unit only with a power source as Do not throw away the carton and packing materials.
Chapter 1 Overview
specified in “Specifications” section. They make an ideal container which to transport the
• The nameplate indicating operating voltage, power unit. When shipping the unit to another location,
consumption, etc., is located at the rear. repack it as illustrated on the carton.
• Should any solid object or liquid fall into the cabinet,
unplug the unit and have it checked by qualified If you have any questions about this unit, contact your
personnel before operating it any further. authorized Sony dealer.
• Do not drop or place heavy objects on the power
cord. If the power cord is damaged, turn off the
power immediately. It is dangerous to use the unit On magnetism
with a damaged power cord.
• Unplug the unit from the wall outlet if it is not to be • Do not place the unit near any objects or pieces of
used for several days or more. equipment which generate magnetism, such as
• Disconnect the power cord from the AC outlet by magnets, speakers, electric clocks, toys using
grasping the plug, not by pulling the cord. magnets, health appliances, etc. Magnetism will
• The socket-outlet shall be installed near the cause picture bounce, oscillations or picture
equipment and shall be easily accessible. discoloration.
• Also, the picture may become fuzzy or the colors
may not reproduce correctly due to earth magnetism.
On installation This depends on direction that the unit is installed.
This is not equipment failure. In such a case, simply
• Allow adequate air circulation to prevent internal heat degauss the unit.
build-up.
Do not place the unit on surfaces (rugs, blankets, etc.)
or near materials (curtains, draperies) that may block On the CRT
the ventilation holes.
• Do not install the unit in a location near heat sources • Dust accumulates on the CRT easily. Clean the CRT
such as radiators or air ducts, or in a place subject to when necessary with a soft cloth.
direct sunlight, excessive dust, mechanical vibration The surface of the CRT is easily scratched; therefore,
or shock. do not rub or touch the surface of the CRT
unnecessarily since this may result in a scratched
picture tube.
On cleaning • If you touch the surface of the CRT, you may feel a
weak electrical shock. This is simply static electricity
To keep the unit looking brand-new, periodically clean that is generated on the surface of the CRT. It will not
it with a mild detergent solution. Never use strong affect the human body.
solvents such as thinner or benzine, or abrasive
cleansers since they will damage the cabinet. As a
safety precaution, unplug the unit before cleaning it.
3
Overview
Monitors are high-performance 20- and 14-inch color Card to save and load monitor setup and adjustment
video monitors. They are suitable for television data. If your system includes more than one monitor,
stations or video production houses, where precise you can use the monitor memory cards to exchange
image reproduction is required. data between monitors. This makes it easy to put all
monitors in your system into the same setup and
1) Trinitron® is a registered trademark of Sony adjustment state.
Corporation.
Standard auto alignment system
Decoder chroma and phase adjustment, as well as
color temperature control, may be performed with the
Features auto alignment system. This makes it possible to
coordinate settings among multiple monitors.
High resolution picture tube
The HR Trinitron picture tube produces a clear, high Expandable input capability
resolution image. The input connector configuration may be easily
Model Aperture Resolution at the modified by simply sliding optional decoder adaptors
grille pitch center of the picture or input expansion adaptors into input option slots at
BVM-20F1U/20F1E 0.30 mm 900 TV lines the rear of the monitor. The BVM-20F1U/20F1E/
BVM-20E1U/20E1E 0.25 mm 1000 TV lines 20E1U/20E1E/14F5U/14F5E/14E5U/14E5E may be
BVM-14F1U/14F1E 0.25 mm 800 TV lines fitted with up to four adaptors, and the BVM-14F1U/
BVM-14E1U/14E1E 0.22 mm 900 TV lines 14F1E/14E1U/14E1E will accept two.
BVM-14F5U/14F5E 0.25 mm 800 TV lines
4:3/16:9 dual aspect ratio design
BVM-14E5U/14E5E 0.22 mm 900 TV lines
The monitors can be changed to either 4:3 or 16:9
aspect ratio with just a simple switching operation. The
Separate control unit (BVM-20FIU/20FIE/
screen can be also changed to 4:3 or 16:9 display by
20EIU/20EIE/14FIU/14FIE/14EIU/14EIE only)
The BVM-20F1U/20F1E/20E1U/20E1E/14F1U/ the replacement of a mask (no tools required).
14F1E/14E1U/14E1E are controlled by a separate
Stable color temperature
control unit, such as a BKM-10R/11R Monitor Control
The internal beam current feedback circuit maintains a
Unit. Use of a separate control unit reduces the space
constant color temperature over long periods of time.
needed for the equipment. With the BVM-20F1U/
20F1E/20E1U/20E1E, it is also possible to attach the
Blue-only mode convenient for monitoring
BKM-10R with an optional BKM-32H Monitor
noise
Control Unit Attachment Kit.
All three CRT cathodes can be driven with a blue
signal, producing a monochrome display. This mode
Controlling monitor groups
is convenient for chroma and phase adjustment, and
Up to 32 monitors can be controlled from this monitor.
for monitoring VTR noise.
First, the built-in menu system is used to assign a
monitor address number to each monitor, divide the
Menu operation
monitors into groups, and assign a group number to
The monitor’s various functions and operating
each group. Then you can use this monitor to control
conditions can be set with on-screen menus.
individual monitors or monitor groups simply by
entering monitor address or group numbers. You can
also execute the same operation on all connected
monitors, or use this monitor to put all connected
monitors into the same setup and adjustment state.
4
Other features BKM-14L Auto Setup Probe
• Compatible with the ISR (Interactive Status This probe allows automatic adjustment of this
Reporting) system. monitor’s color temperature.
Chapter 1 Overview
• Has both RS-485 serial remote and relay contact
parallel remote control connectors.
• Built-in safe area display and test signal generator for For screen
crosshatch, 100% white signal, 20% gray signal, gray
scale, and PLUGE (Picture Line Up Generating BKM-33H20 Monitor 16:9 Mask
Equipment). Adapts the BVM-20F1U/20F1E/20E1U/20E1E screen
• Built-in VITC (Vertical Interval Time Code) reader. for 16:9 aspect ratio display.
• Built-in Caption Vision.
• Pulse cross function for simultaneous checking of the BKM-33H14 Monitor 16:9 Mask
horizontal and vertical synchronization signals. VITS Adapts the BVM-14F1U/14F1E/14E1U/14E1E/
(Vertical Interval Test Signal) checking is also 14F5U/14F5E/14E5U/14E5E screen for 16:9 aspect
possible. ratio display.
• Auto and manual degaussing.
• Built-in CRT protection circuit.
For installation
• The monitor may be mounted in an EIA-standard 19-
inch rack, using an optional BKM-30E20/30E14/
BKM-30E20 Rack Mount Kit
31E14 Rack Mount Kit.
Rack mount kit for mounting the BVM-20F1U/20F1E/
• Controllable from the optional BKM-10R/11R
20E1U/20E1E in an EIA standard 19-inch rack.
Monitor Control Unit. (For details about connection
and operation, refer to the BKM10R/11R Operation
BKM-30E14 Rack Mount Kit
Manual.
Rack mount kit for mounting the BVM-14F5U/14F5E/
14E5U/14E5E in an EIA standard 19-inch rack.
5
Overview
optional decoder adaptors and/or input expansion The input signal type for each connector is set with the
adaptors into input option slots at the rear of the INPUT CONFIGURATION menu, in accordance with
monitor. The BVM-20F1U/20F1E/20E1U/20E1E/ the configuration of the connector panel.
14F5U/14F5E/14E5U/14E5E may be fitted with up to
four adaptors, and the BVM-14F1U/14F1E/14E1U/ BKM-25P PAL Decoder Adaptor
14E1E will accept two. Includes a decoder for analog composite PAL signals
and input/output connectors for six analog channels.
Note The input signal type for each connector is set with the
When installing the adaptors, be sure to perform the INPUT CONFIGURATION menu, in accordance with
necessary input signal setup with the INPUT the configuration of the connector panel.
CONFIGURATION menu. If the setup is not
performed, the adaptors may not function correctly. BKM-26M PAL-M Decoder Adaptor
Includes a decoder for analog composite PAL-M
For information about the INPUT CONFIGURATION signals and input/output connectors for six analog
menu, see “Setting the Input Configuration —INPUT channels. The input signal type for each connector is
CONFIGURATION Menu” on page 33. set with the INPUT CONFIGURATION menu, in
accordance with the configuration of the connector
BKM-20D SDI 4:2:2 Decoder Adaptor panel.
Includes decoders for serial digital component signals
(525/625). Input/output connectors for three serial BKM-27T Tri-Standard Decoder Adaptor
digital channels (component inputs only) and three Includes decoders for analog composite NTSC, PAL,
analog channels. The input signal type for each and SECAM signals and input/output connectors for
connector is set with the INPUT CONFIGURATION six analog channels. The input signal type for each
menu, in accordance with the configuration of the connector is set with the INPUT CONFIGURATION
connector panel. menu, in accordance with the configuration of the
connector panel.
BKM-21D SDI Multi Decoder Adaptor
Includes decoders for serial digital signals (525/625 BKM-28X Analog Input Expansion Adaptor
component and NTSC/PAL composite) and analog Used with decoder adaptors, increases the number of
composite signals (NTSC and PAL). Input/output input/output channels. Includes input/output
connectors for three serial digital channels and three connectors for six analog channels. The input signal
analog channels are equipped. The input signal type type for each connector is set with the INPUT
for each connector is set with the INPUT CONFIGURATION menu, in accordance with the
CONFIGURATION menu, in accordance with the configuration of the connector panel.
configuration of the connector panel.
BKM-48X HD Analog Input Expansion Adaptor
BKM-22X SDI Input Expansion Adaptor Increases the number of input/output channels.
Used with decoder adaptors, increases the number of Includes input/output connectors for six analog
input/output channels. Includes input/output channels. For each input/output connector, either
connectors for three serial digital channels and three floating or ground can be selected by the switch inside
analog channels. The input signal type for each the board. The input signal type for each connector is
connector is set with the INPUT CONFIGURATION set with the INPUT CONFIGURATION menu, in
menu, in accordance with the configuration of the accordance with the configuration of the connector
connector panel. panel.
6
Connector Panel Configuration
The monitor comes standard with connectors for one Notes
Chapter 1 Overview
channel of Y/R–Y/B–Y or RGB. By adding optional • Only one BKM-22X board can be installed in the
decoder adaptors and/or input expansion adaptors, the monitor together with either the BKM-20D or the
input/output connector panel can be assembled in a BKM-21D.
wide variety of configurations. • The BKM-20D, BKM-21D, and BKM-22X can not
The signals that each of the adaptors’ connectors provide proper active-through outputs if a signal
supports are given in the table below. The type of whose format is not selected in the INPUT
signal to be applied to each input/output connector is CONFIGURATION menu is input. (If AUTO is
set with the INPUT CONFIGURATION menu. selected, input a signal which has the same format
with the signal monitored last.)
Adaptor name
BKM-20D BKM-21D BKM-24N BKM-25P BKM-26M BKM-27T BKM-22X BKM-28X BKM-48X1)
SDI 4:2:2 SDI Multi NTSC PAL PAL-M Tri- SDI Input Analog HD Analog
Decoder Decoder Decoder Decoder Decoder Standard Expansion Input Input
Adaptor Adaptor Adaptor Adaptor Adaptor Decoder Adaptor Expansion Expansion
Adaptor Adaptor Adaptor
Serial Component O O ®
digital 525/625
input Composite ® O ®
NTSC
Composite ® O ®
PAL
Analog Composite ® O O ® ® O ® ® ®
input NTSC
Composite ® O ® O ® O ® ® ®
PAL
Composite ® ® ® ® O ® ® ® ®
PAL-M
Composite ® ® ® ® ® O ® ® ®
SECAM
Y/R–Y/B–Y O O O O O O O O O
525/625
RGB 525/ O O O O O O O O O
625
Y/C O ® ® O ® ®
NTSC
Y/C ® O ® O ® ®
PAL
Y/C ® ® O ® ® ®
PAL-M
Number of digital 3 3 – – – – 3 – –
inputs
Number of analog 3 3 6 6 6 6 3 6 6
input
O: Independent input possible ®: Input possible when used with decoder adaptor
1) Equipped with floating/non-floating ground mode selector
for hum reduction.
7
Overview
The table on the right shows which decoder adaptor Input signal type Decoder adaptor
Chapter 1 Overview
will be selected preferentially when more than one and format BKM- BKM- BKM- BKM-
decoder adaptor which can accept the NTSC or PAL 24N 25P 27T 21D
signal format have been installed in the monitor. Composite NTSC 1 3 2
signal PAL 1 3 2
For example, when a BKM-24N and a BKM-27T are Y/C NTSC 1 2
installed and an NTSC signal is selected, the NTSC signal
PAL 1 2
signal connected to the BKM-24N’s input connectors
Numbers in the table show priority.
and the NTSC signal connected to the BKM-27T’s
input connectors are both processed by the decoder on
the BKM-24N.
Figure 1 Figure 2
When one of the input option slots on the rear of the 20D/21D may be damaged or detached (see Figure 4).
monitor has a BKM-20D/21D (optional) installed, if Using the BKM-20D/21D with the radiation shield
the slot to the right has another adaptor or the analog damaged or detached may result in electromagnetic
input connectors board, or a cover plate fitted, as interference. Always use care about the radiation
shown in Figure 3, the radiation shield of the BKM- shield.
BKM-20D/21D
8
Location and Function of Parts
Front Panel
BVM-14F5U/14F5E/14E5U/14E5E
Chapter 1 Overview
1 Tally lamp
2 POWER switch
0 SHIFT button
3 DEGAUSS button
4 Numeric keypad
!¡ Function buttons
5 MANUAL adjustment
buttons and knobs
8 STANDBY lamp
BVM-20F1U/20F1E/20E1U/20E1E/14F1U/14F1E/14E1U/14E1E
1 Tally lamp
8 STANDBY lamp
(Illustration: BVM-20F1U/20F1E/20E1U/20E1E)
9
Location and Function of Parts
This manual explains the location and function of parts Channel number entry method:
and controls using the control panel of the BVM- (In the explanation below, x represents any digit
14F5U/14F5E/14E5U/14E5E. The explanation applies between 1 and 9, and y represents any digit between
Chapter 1 Overview
7 8 9 CHROMA
10
6 Menu operation buttons
MENU button: Press to display the Menus.
UP MENU
Chapter 1 Overview
UP/DOWN buttons: Press to select the
DOWN ENTER
items and setting values.
7 POWER lamp
Lights when the monitor is put into operation mode
from standby mode (see STANDBY lamp 8) by
pressing the POWER switch 2.
Note
When the STANDBY lamp 8 is blinking, the monitor
cannot be put into operation mode (internal data
initialization is taking place). Wait until the
STANDBY lamp 8 is steadily lit.
8 STANDBY lamp
Lights when the monitor is in standby mode. The
monitor will be in standby mode under the following
conditions:
• The MAIN POWER switch (on the rear panel) is
turned on (the STANDBY lamp will blink for a few
moments after the switch is turned on, then will
light).
• The monitor is changed from operation mode to
standby mode by external control.
11
Location and Function of Parts
Each time the SHIFT button is pressed, the LED turns turns off, and the operation conditions are changed.
on (SHIFT ON: lit in orange) and off (SHIFT OFF: lit Each button has two functions. Select one of the two
in green). functions by pressing the SHIFT button 0. When the
SHIFT OFF: The functions indicated on the left side SHIFT button is set to ON, the LED lights in orange,
of the function buttons can be used. and when the SHIFT button is set to OFF, the LED of
SHIFT ON: The functions indicated on the right side each button lights in green.
of the function buttons can be used.
(H delay) button: When this button is pushed in (ON), the picture moves
horizontally, and a horizontal sync signal appears approximately one quarter in the
left edge of the screen.
• The brightness of the picture increases automatically, and it makes it easy to check
the sync part.
• If it is pressed together with the button, a pulse cross picture is displayed.
(V delay) button: When this button is pushed in (ON), the picture moves vertically,
and a vertical sync signal appears approximately in the center of the screen.
• The brightness of the picture increases automatically, and it makes it easy to check
the sync part.
• If it is pressed together with button, a pulse cross picture is displayed.
16 : 9
MONO button: When this button is pushed in (ON), a monochrome picture is displayed.
When the buttons is off, the monitor switches automatically between color and
SYNC monochrome mode, depending on the presence or absence of color burst signal.
BLUE APT (aperture) button: When this button is pushed in (ON), the frequency response
ONLY can be modified. The degree of modification is set with the menu.
This function is available when an optional decoder adaptor such as a BKM-24N is
MONO R installed.
APT G
F2 F1 button: When this button is pushed in (ON), the characters disappear from the
F4
monitor on the MANUAL menu of the level 2 of the CONTROL PRESET ADJ menu,
the MANUAL menu of the level 2 of the COLOR TEMP ADJ menu, and the
SAFE ALIGNMENT menu of the level 2 of SETUP menu.
ADDRESS
AREA
F2 button: When this button is pushed in (ON), you can access directly the MANUAL
menu of the level 2 of the COLOR TEMP ADJ menu, if the short-cut function is
assigned to this button.
For details of short-cut functions, see “Setting the Channel Selection Method and Power-Up
Conditions – System Configuration Menu” on page 42.
ADDRESS button: When this button is pushed in (ON), the ADDRESS menu appears
on the screen. By using the ADDRESS menu, operation conditions for multiple
monitors are set.
For details of the ADDRESS menu, see “Selecting the Monitor to Control - ADDRESS
Menu” on page 54.
12
SHIFT ON (LEDs of function buttons in orange)
16:9 button: When this button is pushed in (ON), the aspect ratio changes to
Chapter 1 Overview
16:9, and when set to OFF, the aspect ratio changes to 4:3.
SYNC button: When this button is pushed in (ON), the monitor synchronizes
to the sync signal input to the SYNC connectors on the rear panel (EXT
SYNC). When set to OFF, it synchronizes to the sync signal included in
the signals being monitored (INT SYNC).
Notes
• When INT SYNC is selected, use a component or YC signals including a
sync signal on the Y signal, and use RGB signal including a sync signal
on the G signal.
16 : 9 • To monitor serial digital signals, select INT SYNC.
SYNC
BLUE ONLY button: When this button is pushed in (ON), red and green
BLUE signals are cut, and only the blue signal is displayed as a monochrome
ONLY picture. It makes it easy to adjust CHROMA and to check VTR noise.
MONO R R/G/B buttons: When these buttons are pushed in (ON), R(red), G(green),
and B(blue) beams are cut respectively.
APT G
COMB B
F2 F4
SAFE SAFE AREA button: When this button is pushed in (ON), a safe area is
ADDRESS
AREA displayed on the screen.
Note
When EXT SYNC is selected, the safe area display possibly may not be
shown in the correct position.
13
Location and Function of Parts
the monitor
memory card.
Take out the
Card monitor memory
card.
EJECT button
Press the EJECT button to eject
!£ OPTION connector
Used to connect the BKM-11R Monitor Control Unit
or BKM-14L Auto Setup Probe.
14
Rear Panel
6 Analog input/output
Chapter 1 Overview
connectors
8 REMOTE 1 connectors
and TERMINATE
switch
9 REMOTE 2 connector
1 MAIN POWER switch
3 Fuse
For details of the SYSTEM CONFIGURATION menu, see 5 CONTROL UNIT connector (female, D-sub 9-
“Setting the Channel Selection Method and Power-Up pin)(not provided on BVM-14F5U/14F5E/14E5U/
Conditions —SYSTEM CONFIGURATION Menu” on page 14E5E)
42.
Connects a monitor control unit such as the BKM-10R
using a straight cable with D-sub 9-pin plugs such as
2 AC IN connector (3-pin)
an RCC-5G (not supplied).
Connects the monitor to an AC power source, via the
supplied AC power cord.
Plug holder
15
Location and Function of Parts
IN REMOTE 1
Y/G Y/G connectors (BNC)
OUT
IN REMOTE 1 IN connector
IN
TERMINATE
IN
ON
OFF TERMINATE switch
R-Y/R R–Y/R connectors (BNC)
OUT
IN
RGB signals, component signals (Y, R–Y, and B–Y), These are RS-485 serial interface connectors, used for
or composite sync signals can be fed in the IN connecting two or more BVM/HDM-series monitors.
connectors. The type of signal applied to each The IN and OUT connectors form a loop-through
connector is set with the INPUT CONFIGURATION connection. Set the TERMINATE switch to OFF.
menu. The OUT connectors are used for loop-through Connect two monitors using a straight cable with D-
output of the input signal. When not using loop- sub 9-pin plugs such as an RCC-5G (not supplied) as
through, connect a 75-ohm terminator (not supplied) to shown in the figure.
the OUT connectors.
The BVM-20F1U/20F1E/20E1U/20E1E/14F5U/
14F5E/14E5U/14E5E may be fitted with up to four TERMINATE TERMINATE
ON ON
adaptors, and the BVM-14F1U/14F1E/14E1U/14E1E OFF OFF
will accept two.
OUT OUT
TERMINATE TERMINATE
switch: OFF switch: OFF
16
9 REMOTE 2 connector (female, D-sub 9-pin)
Forms a pararell switch and controls the monitor
externally. The pin arrangement and factory setting
Chapter 1 Overview
function assigned to each pin are given below.
5 1
9 6
17
Menu Structure
Chapter 2 Menus
The various functions and operating conditions of the
monitor can be set with on-screen menus. Each menu
consists of several levels of subsidiary menus or lists
of settings. An overview of the menu system is shown
in “Menu Directories” on page 21, and the details of
the structure of each menu is shown at the top of the
explanation of the menu.
Chapter 2 Menus
Displaying Menus
To display menus, press the MENU button. When you select a menu from the main menu, a list of
items for the selected menu is displayed on the screen.
A list of menus, called “the main menu”, is displayed The display of this list is called “the level 1 display” of
on the monitor screen. the selected menu.
M E N U
The adjustments and settings which can be made with
p C O N T R O L P R E SE T A D J ... A the respective menus are outlined in the table below.
C O L O R T E M P A D J ... B
S E T U P ... C Note
M E M O R Y C A R D ... D On this monitor, menu settings displayed in blue
C O P Y ... E
S T A T U S ...
cannot be changed.
F
M A I N T E N A N C E ... G
K E Y P R O T E C T O F F H
Main menu
19
Menu Structure
e.g. A 1 3 21
Note
The menu numbers are merely for convenience of
explanation. They do not appear on the screen of your
monitor.
ADDRESS Menu
In addition to the menus listed in the table, the
ADDRESS menu is provided. This ADDRESS menu
is used to select the monitor or the monitor group, so
that when several monitors are connected together via
serial remote ports, the control panel can select which
monitor to control.
To display or exit the ADDRESS menu, press the
ADDRESS button. The method of choosing menu
items and changing settings is the same as with the
other menus.
20
Menu Directories
The menu system for the BVM-series monitors The diagram below shows part of the structure of the
covered by this manual is largely divided into eight menu system from the main menu down to level 2. For
menus (or eight menu groups), which are arranged in the structure of each menu, see the page whose number
the main menu. Each of the eight menus consists of is shown in ( ).
many items (subsidiary menus and settings) arranged
Chapter 2 Menus
on several menu levels.
H CV RC (4/4)
21
Basic
Basic Menu
Menu Operations
Operations
4 5 6 1 Numeric keypad
1 Press the MENU button 5.
The main menu is displayed.
7 8 9
22
4 Repeat steps 2 and 3 until the desired menu is 2 Using the UP and DOWN buttons or PHASE
displayed. knob, change the setting.
On how to make adjustments and settings on the menu
thus displayed, see the following descriptions.
3 Press the ENTER or Ent button.
The setting is confirmed (the item is displayed in
[ ↓ ] indicates that
the menu white text again).
continues onto
I N P U T C O N F I G U R A T I O N ↑↓
next page.
Selecting from a setting list
Chapter 2 Menus
0 1 C H [ ↑ ] indicates that
p F O R M A T ... N T S C - 7 .5 the menu is
S L O T N O 2 continued from
previous page.
1 Using the UP and DOWN buttons or PHASE knob,
I N P U T N O 1 move the cursor to the desired item in the setting list.
Y C S E P 3L I N E S C O M B Select from
S Y N C M OD E I N T various options. S C R E E N MO D E
S C R E E N M O D E ... 4 : 3 - N O R M Indicates that
S A F E A R E A O F F
selecting this 4 : 3 - N O R M
p
item brings you
S C A L E ... 8 0 % to a lower menu 4 : 3 - U N D R
A P E R T U R E O F F level. 1 6 : 9 - N O R M
V A LU E 1 0 0 Enter numerical 1 6 : 9 - U N D R
values.
23
Basic Menu Operations
2 Set the value in one of the following three ways: 3 Select the character you wish to enter using the UP
• Enter the value using the numeric keypad and DOWN buttons or PHASE knob. When you
• Select the value using the UP and DOWN buttons press the UP button, or turn the PHASE knob
• Select the value using the PHASE knob clockwise, characters and symbols appear one by
one in the order shown below.
3 Press the ENTER button.
The setting is confirmed (the item is displayed in A, B, .............Y, Z, 0, 1, ...............8, 9, ( , ), :, ;, .,
white text again). -, +, /, &, CH, (space), ?
Chapter 2 Menus
P R O G
P R O G
E D I T
E D I T
C A M
C A M
V T R
V T R
p N E W N A M E
p N E W N A M E
C ?
24
Preset Adjustment of the Picture Level Control
Knobs — CONTROL PRESET ADJ Menu
Overview
The preliminary adjustment of contrast, brightness, (1) Adjustment with the MANUAL knobs
chroma, and phase are carried out with the CONTROL (2) Automatic adjustment (An external color bar signal
PRESET ADJ menu to set the preset values to the is necessary.)
knobs for the above-mentioned adjustments. Preset (3) Copying data from other channels, common data,
values can be set either commonly to all channels or other BVM-series monitors that have been
Chapter 2 Menus
separately for individual channels. connected via the serial remote connector, or from
Preset values can be set in the following ways: data stored in monitor memory cards
(4) Restoring factory settings.
25
Preset Adjustment of the Picture Level Control Knobs — CONTROL
PRESET ADJ Menu
[A11] MANUAL menu CH SET: Copy data set for another channel. Input
Adjust values by turning the PHASE, CHROMA, the number of the channel from which the data
BRIGHT, and/or CONTRAST knobs. After the will be copied.
adjustment, press the ENTER button to confirm the When the input channel number is deleted with
adjusted values. the Del button. the number “1” appears instead.
PHASE: xxxx Restore the previous setting by pressing the
CHROMA: xxxx MENU button, then re-enter the channel number.
BRIGHT: xxxx (Setting with the UP and DOWN buttons or
Chapter 2 Menus
26
Adjusting the Color Temperature — COLOR TEMP
ADJ Menu
Overview
The color temperature is adjusted with the COLOR (3) Copying other data
TEMP ADJ menu. The color temperature can be set Copying data from other channels, common data, other
either commonly to all channels or individually for BVM-series monitors that have been connected via the
each channel. serial remote connector, or from data stored in monitor
The adjusted value can then be used as an original memory cards.
Chapter 2 Menus
value.
27
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
PROBE B12 SONY BKM-14L B121 ADJUST B1211 START B12111 SET PROBE
ANALYZE B1212 X ON CRT
GRASEBY SLS9400 Y
MINOLTA CA-100 LOW LIGHT (20IRE)
PHILIPS RM5639 HIGHLIGHT (100IRE)
THOMA TF6 B122 START D65
X D93
Y SET PROBE
LOW LIGHT ON THIS CRT B12121 X
(20IRE) Y
HIGHLIGHT SET PROBE
ON CRT L
(100IRE)
D65
D93
28
Constituent Menus of the COLOR TEMP ADJ Menu
This section describes the functions of the constituent [B11] MANUAL menu
menus of the COLOR TEMP ADJ menu. Set the following data necessary to perform knob
adjustment and select ADJUST.
Notes ADJUST...: Adjust the gain and bias. To shift
• The menu numbers (A, B1, C11 and so on) are not between gain adjustment and bias adjustment,
Chapter 2 Menus
displayed on the monitor screen. press the UP or DOWN button. Use the
For details of menu numbers, see page 20. appropriate knob for each adjustment as described
• An arrow (÷) following the description of an item below. After the adjustment, press the ENTER
or setting in each menu indicates another menu which button to confirm the adjusted values.
appears or an operation which is executed when you RED: CONTRAST knob (Adjust the R gain or
select that menu item or setting. If the description of bias with the CONTRAST knob.)
an item or setting is not followed by an arrow, it GREEN: BRIGHT knob (Adjust the G gain or
indicates that selecting the item or setting finishes the bias with the BRIGHT knob.)
setting operation. BLUE: CHROMA knob (Adjust the B gain or
bias with the CHROMA knob.)
[B] COLOR TEMP ADJ menu LUMINANCE: PHASE knob (Adjust luminance
Select STD, COL1, COL2, or CH SET. ÷ [B1] with the PHASE knob.)
STD: Use common data (factory setting: D65).
COL1: Use common data (factory setting: D93). To reset RED/GREEN/BLUE to the value
COL2: Use common data (factory setting: D56/ before adjustment
D651)). When you are adjusting the gain or bias using the
CH SET: Use data for each individual channel MANUAL adjustment knobs, you can reset the
(factory setting: D65). Use the numeric keypad to setting to the one before adjustment by pressing the
select the desired channel. corresponding MANUAL button.
To reset all the settings at the same time, press the
[B1] STD/COL1/COL2/CH SET menu PHASE button.
Select the adjustment method.
MANUAL...: Set with the MANUAL knob. ÷ Note
[B11] You cannot reset the setting after you press the
PROBE...: Set using a probe. ÷ [B12] ENTER button.
COPY...: Copy data from elsewhere. ÷ [B13]
TRIM...: Perform fine adjustments after setting the ORIGINAL VALUE...: Set the initial value.
color temperature. ÷ [B14] STD: Use common data (factory setting: D65).
COL1: Use common data (factory setting: D93).
COL2: Use common data (factory setting: D56/
D651)).
SIGNAL: Select the white signal to be used for
adjustment.
INT: Use an internal signal. Simultaneously with
the adjustment of the gain and bias, the 100 IRE
and 20 IRE signals are automatically switched.
EXT: Use an external input signal. When
adjusting the gain and bias, input the proper
signal.
...........................................................................................................................................................................................................
1) D56: BVM-20F1U/20E1U/14F1U/14E1U/14F5U/14E5U
D65: BVM-20F1E/20E1E/14F1E/14E1E/14F5E/14E5E
29
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
30
[B131] OTHER VALUE menu: [B133] MEMORY CARD menu
Select one of the following. ÷ Copy is carried out. Select the file name. ÷ [B1331]
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93). [B1331] FILE NAME menu
COL2: Copy common data (factory setting: D56/ Select STD, COL1, COL2,or CH SET of the memory
D651)). card data. ÷ Copy is carried out.
CH SET: Copy data from a particular channel STD: Copy common data (factory setting: D65).
(factory setting: D65). Enter the number of the COL1: Copy common data (factory setting: D93).
Chapter 2 Menus
channel from which the data will be copied. COL2: Copy common data (factory setting: D56/
When the input channel number is deleted with D651)).
the Del button. the number “1” appears instead. CH SET: Copy data from a particular channel
Restore the previous setting by pressing the (factory setting: D65). Enter the number of the
MENU button, then re-enter the channel number. channel from which the data will be copied.
(Setting with the UP and DOWN buttons or When the input channel number is deleted with
PHASE knob is possible without pressing the the Del button. the number “1” appears instead.
MENU button.) Restore the previous setting by pressing the
D65: Copy the color temperature of D65. MENU button, then re-enter the channel number.
D93: Copy the color temperature of D93. (Setting with the UP and DOWN buttons or
PHASE knob is possible without pressing the
[B132] OTHER MONITOR menu MENU button.)
Input the address of the monitor from which the data
will be copied. [B14] TRIM menu
MONITOR ADDRESS: Input the address of the Trim the original setting by selecting ADJUST.
monitor from which the data will be copied. ÷ ADJUST: Adjust the gain and bias. To shift between
[B1321] gain adjustment and bias adjustment, press UP/
DOWN buttons. Use appropriate knobs in each
[B1321] MONITOR ADDRESS menu adjustment as described below. After the
Select STD, COL1,COL2, or CH SET. ÷ Copy is adjustment, press the ENTER button to confirm
carried out. the adjusted values.
STD: Copy common data (factory setting: D65). RED: CONTRAST knob (Adjust the R gain or
COL1: Copy common data (factory setting: D93). bias with the CONTRAST knob.)
COL2: Copy common data (factory setting: D56/ GREEN: BRIGHT knob (Adjust the G gain or
D651)). bias with the BRIGHT knob.)
CH SET: Copy data from a particular channel BLUE: CHROMA knob (Adjust the B gain or
(factory setting: D65). Enter the number of the bias with the CHROMA knob.)
channel from which the data will be copied.When LUMINANCE: PHASE knob (Adjust luminance
the input channel number is deleted with the Del with the PHASE knob.)
button. the number “1” appears instead. Restore
the previous setting by pressing the MENU To reset RED/GREEN/BLUE to the value
button, then re-enter the channel number. (Setting before adjustment
with the UP and DOWN buttons or PHASE knob When you are adjusting the gain or bias using the
is possible without pressing the MENU button.) MANUAL adjustment knobs, you can reset the
setting to the one before adjustment by pressing
the corresponding MANUAL button.
To reset all of settings at the same time, press the
PHASE button.
...........................................................................................................................................................................................................
1) D56: BVM-20F1U/20E1U/14F1U/14E1U/14F5U/14E5U
D65: BVM-20F1E/20E1E/14F1E/14E1E/14F5E/14E5E
31
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
Note
Even if NOT APPLY of the TRIM item is selected,
pressing the ENTER button to confirm the adjusted
values results in that APPLY will be selected.
32
Setting the Input Configuration — INPUT
CONFIGURATION Menu
Overview
Data pertaining to the input signals are set with the Assigning the Signal Type and Format
INPUT CONFIGURATION menu.
When a channel number (1 to 90) is entered with the The signal type and format which can be assigned to
numeric keypad, it is then possible to set which input each channel number vary, depending on what
connector on the rear panel will be assigned to that adaptors are installed in the rear panel.
Chapter 2 Menus
channel number, and select the type of signal that will
be connected. The channel numbers from 91 to 99 are Assigning serial digital signals
assigned to internal signals. It is possible to assign serial digital signals to the serial
091: PLUGE signal (Picture Line Up Generating digital input connectors on the BKM-20D/21D/22X
Equipment) adaptors. However, at least one BKM-21D which
092: 20% gray signal includes the decoder for serial digital signals or BKM-
093: 100% white signal 20D which includes the decoder for serial digital
094: five-step gray scale signal component signals must be installed.
095: cross hatch signal
096: cross hatch signal Assigning analog composite signals
097: dot signal It is possible to assign any composite signal to the
098: cross hatch signal analog signal input connectors of the BKM-20D/21D/
099: 0% black signal 22X, and any of the connectors of the BKM-24N/25P/
26M/27T/28X/48X adaptors. However, at least one of
the following decoder adaptors must be installed:
Assigning Slot and Connector Numbers
To assign NTSC signals: BKM-21D/24N/27T
To assign PAL signals: BKM-21D/25P/27T
Set which input connector on which slot will be
To assign PAL-M signals: BKM-26M
assigned to the current channel. The slots are
To assign SECAM signals: BKM-27T
numbered from the left, as seen when facing the rear
panel, with the REMOTE connectors slot being
Assigning Y/C signals
number 1, the input option slots numbers 2 to 5, and
It is possible to assign any Y/C signals to the input
the analog input connectors slot being number 6. The
connectors of the BKM-24N/25P/26M/27T/28X/48X
connectors are numbered 1 to 6 (from the top) for the
adaptors. However, at least one of the following
slot.
decoder adaptors must be installed:
To assign NTSC signals: BKM-24N/27T
To assign PAL signals: BKM-25P/27T
To assign PAL-M signals: BKM-26M
33
Setting the Input Configuration — INPUT CONFIGURATION Menu
CONTROL PRESET
CH SET
34
Constituent Menus of the SET UP / INPUT CONFIGURATION Menu
This section describes the functions of the constituent [C1](2/2) INPUT CONFIGURATION menu (2/2)
menus of the SET UP/INPUT CONFIGURATION Set input signal data for each channel.
menu. xxCH: Current channel is indicated. Enter a channel
number with the numeric keypad if changing the
Notes channel. The settings below will be stored as
Chapter 2 Menus
• The menu numbers (A, B1, C11 and so on) are not information about the signal to be connected to
displayed on the monitor screen. this channel.
For details of menu numbers, see page 20. FILTER: Switch the filter operation (OFF or ON)
• An arrow (÷) following the description of an item when the monochrome display is selected.
or setting in each menu indicates another menu which CHANNEL NAME...: Give the channel a name. ÷
appears or an operation which is executed when you [C15]
select that menu item or setting. If the description of CONTROL: Select whether to use local (“CH SET”)
an item or setting is not followed by an arrow, it or common (“PRESET”) values for contrast,
indicates that selecting the item or setting finishes the brightness, chroma, and phase.
setting operation. PRESET: Use common data.
CH SET: Use values set for each channel.
[C1](1/2) INPUT CONFIGURATION menu (1/2) COLOR TEMP...: Set the color temperature. ÷
Set input signal data for each channel. [C16]
xxCH: Current channel is indicated. Enter a channel H PHASE: Set the horizontal picture position (–128
number with the numeric keypad if changing the to +127).1)
channel. The settings below will be stored as SAD H POSITION: Adjust the horizontal display
information about the signal to be connected to position of the safety area (–128 to +127). 1)
this channel. COPY...: Select a method for copying data from
FORMAT...: Select the input signal type. ÷ [C11] elsewhere. ÷ [C17]
SLOT NO: Enter the slot number.
INPUT NO: Enter the input connector number. 1) The monitor will not operate correctly if values above or
YC SEP...: Select a Y/C separation filter. ÷ [C12] below the allowable range are entered.
SYNC MODE: Select the sync signal.
INT: Use an internal sync signal. [C11] FORMAT menu
EXT: Use an external sync signal. Select the signal format.
SCREEN MODE...: Select the scan size. ÷ [C13] COMPOSITE...: Composite signal. ÷ [C111]
SAFE AREA: Choose whether or not to display the YC...: Y/C signal. ÷ [C111]
safe area (OFF or ON). COMPONENT...: Component or RGB signal. ÷
SCALE...: Select the safe area size. ÷ [C14] [C112]
APERTURE: Choose whether or not to use aperture SDI...: Serial digital signal. ÷ [C113]
adjustment (OFF or ON).
VALUE: Enter the aperture adjustment value (0 to Note
200). If there is no input connector or decoder corresponding
to a format, that format will not be selectable (the
cursor will skip over that item).
35
Setting the Input Configuration — INPUT CONFIGURATION Menu
36
[C16] COLOR TEMP menu [C1721] MEMORY CARD menu
Select STD, COL1, COL2, or CH SET. Select which channel of the chosen file from which to
STD: Use common data (factory setting: D65). copy data. ÷ Copy is carried out.
COL1: Use common data (factory setting: D93). CH NO: Enter the channel number.
COL2: Use common data (factory setting: D56/ When the input channel number is deleted with
D651)). the Del button. the number “1” appears instead.
CH SET: Use data for the current channel (factory Restore the previous setting by pressing the
setting: D65). MENU button, then re-enter the channel number.
Chapter 2 Menus
(Setting with the UP/DOWN buttons or PHASE
[C17] COPY menu knob is possible without pressing the MENU
Select the source to be copied from. button.)
OTHER CH: Copy data from another channel.
Enter the channel number.
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP/DOWN buttons or PHASE
knob is possible without pressing the MENU
button.)
OTHER MONITOR...: Copy data from another
monitor. ÷ [C171]
MEMORY CARD...: Copy data from a memory
card. ÷ [C172]
...........................................................................................................................................................................................................
1) D56: BVM-20F1U/20E1U/14F1U/14E1U/14F5U/14E5U
D65: BVM-20F1E/20E1E/14F1E/14E1E/14F5E/14E5E
37
Assigning the Remote Control Functions
— REMOTE Menu
Overview
The remote control functions are set with the About monitor address and group numbers
REMOTE menu. With this monitor, both serial remote
control (REMOTE 1) and parallel remote control
The BKM-10R/11R or HDM-14E5U, BVM-14E5U/
(REMOTE 2) are possible. It is possible to
14E5E/14F5U/14F5E/14G5U/14G5E/14G5A are able
simultaneously use the REMOTE 1, and REMOTE 2
to control up to 32 monitors connected via serial
Chapter 2 Menus
Note
The address number must differ from one monitor to
another. If two or more monitors have the same
address number, an operation error occurs.
INPUT CONFIGURATION C1
REMOTE C2 REMOTE 1 CONFIG C21 MONITOR ADDRESS
PASSWORD C3 GROUP ADDRESS
SYSTEM CONFIGURATION C4 REMOTE MODE C211
ON SCREEN SET C5
ALIGNMENT C6 REMOTE 2 CONFIG C22 1 PIN C221 CH (1/2)
EXTEND MENU C7 REMOTE 2 2 PIN
3 PIN BLUE ONLY (2/2)
4 PIN
5 PIN
6 PIN
7 PIN
8 PIN
38
Constituent Menus of the SET UP / REMOTE Menu
This section describes the functions of the constituent [C22] REMOTE 2 CONFIG menu
menus of the SET UP/REMOTE menu. Select the REMOTE 2 connector pins for which you
want to change the function. The factory settings for
Notes each pin are given below. ÷ [C211]
• The menu numbers (A, B1, C11 and so on) are not 1 PIN...: CH01
Chapter 2 Menus
displayed on the monitor screen. 2 PIN...: CH02
For details of menu numbers, see page 20. 3 PIN...: EXT SYNC
• An arrow (÷) following the description of an item 4 PIN...: MONO
or setting in each menu indicates another menu which 5 PIN...: SAFE AREA
appears or an operation which is executed when you 6 PIN...: unused
select that menu item or setting. If the description of 7 PIN...: unused
an item or setting is not followed by an arrow, it 8 PIN...: TALLY
indicates that selecting the item or setting finishes the
setting operation. [C221](1/2) 1-8 PIN menu (1/2)
Assign a function to the selected pin.
[C2] REMOTE menu CH: Select a channel number. Enter the desired
Select the type of remote control. channel number with the numeric keypad.
REMOTE 1 CONFIG...: Set the address and group ----: Set to unused.
number of the monitor controlled via the UNDERSCAN: Set underscan on or off.
REMOTE 1 (serial remote control) connector. ÷ 16:9: Set a 16:9 aspect ratio on or off.
[C21] H DELAY: Set the horizontal sync display on or off.
REMOTE 2 CONFIG...: Set the pin assignments for V DELAY: Set the vertical sync display on or off.
the REMOTE2 (parallel remote control) EXT SYNC: Set the synchronization to external sync
connector. ÷ [C22] signals enabled or disabled.
REMOTE 2: Select whether or not parallel remote COMB: Set the comb filter on or off.
control will be used (ON or OFF). APERTURE: Set the correction of frequency
characteristics enabled or disabled.
[C21] REMOTE 1 CONFIG menu MONO: Set monochrome display on or off.
Set the monitor address, group address and remote
mode of the monitor. [C221](2/2) 1-8 PIN menu (2/2)
MONITOR ADDRESS: Enter a number. Assign a function to the selected pin.
GROUP ADDRESS: Enter a number. BLUE ONLY: Set the blue signal pictures display
REMOTE MODE: Select the remote mode. ÷ (monochrome) on or off.
[C211] R OFF: Set cutting red beams enabled or disabled.
G OFF: Set cutting green beams enabled or disabled.
[C211] REMOTE MODE menu B OFF: Set cutting blue beams enabled or disabled.
Select a remote mode according to the type of VITC ON: Set the VITC display on or off.
monitors connected through the REMOTE 1 SAFE AREA ON: Set the safe area display on or off.
connector. CAPTION VISION: Set the caption vision on or off.
When only Sony BVM-xxE/F/G or HDM-xxE TALLY ON: Set tally signals on or off.
series monitors are connected: set REMOTE DEGAUSS ON: Set degaussing on or off.
MODE to 0. POWER OFF: Set the monitor power on or off.
When a Sony BVM-xx11/16 series monitor or a
Sony PVM monitor (with BKM-103 Serial For details of pin connections, see the description of the
Remote Interface Kit installed) is connected: REMOTE 2 connector on page 17.
set REMOTE MODE to 1 and enter a number
over 64 as the MONITOR ADDRESS for each
connected Sony BVM-xxE/F/G and HDM-xxE
series monitor.
39
Setting the Password — PASSWORD Menu
Overview
A four-digit password can be specified and applied to Use of the password
desired menu options to prohibit the menu settings
from being changed without permission. The password
The message “ENTER PASSWORD” is displayed
is set with the PASSWORD menu.
when an attempt is made to select a menu item for
A password is always assigned to the PASSWORD which the password has been applied. Then, enter the
Chapter 2 Menus
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3 ENTER CHANGE ENTER RE-ENTER
PASSWORD C31 PASSWORD C311 PASSWORD C3111 PASSWORD
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
APPLY CONTROL PRESET ADJ
ALIGNMENT C6 PASSWORD C312
COLOR TEMP ADJ
EXTEND MENU C7
SET UP
MEMORY CARD
COPY
KEY PROTECT
40
[C3111] ENTER PASSWORD menu
Create a new password.
RE-ENTER PASSWORD TO CONFIRM : Enter
the new password again and press the ENTER
button. ÷ The password is recorded.
To change it, press the MENU button. ÷ Return to
[C31].
Chapter 2 Menus
[C312] APPLY PASSWORD menu
Choose whether or not to apply the password to each
menu.
CONTROL PRESET ADJ: Select YES or NO.
CONTROL TEMP ADJ: Select YES or NO.
SET UP: Select YES or NO.
MEMORY CARD: Select YES or NO.
COPY: Select YES or NO.
KEY PROTECT: Select YES or NO.
41
Setting the Channel Selection Method and Power-
Up Conditions — SYSTEM CONFIGURATION Menu
Overview
The SYSTEM CONFIGURATION menu is used for (5) AFC time constant
the following settings:
(6) Residual subcarrier detection (when using the
(1) Channel number entry method BKM-24N/25P)
Select a method to enter channel numbers using the It is possible to detect residual subcarrier signals from
Chapter 2 Menus
ten-key pad, from two options. phase change by setting the adaptor’s residual
subcarrier switch on.
(2) Power-up condition
This menu sets the condition of the monitor when the (7) Auto chroma control (ACC) (when using the
MAIN POWER switch on the rear panel is switched BKM-27T)
on.
(8) Holding the current contrast/brightness setting
(3) Power-up input channel after white balance adjustment
Specify the channel to be selected automatically when
the power is turned on. (9) Making a shortcut to a white balance
adjustment menu
(4) Time from power-up until degauss Make the [F2] key a shortcut key to display the
If several monitors are turned on at the same time and COLOR TEMP ADJ MANUAL menu. This allows
all start degaussing at the same time, there will be a you to jump directly to the MANUAL menu display
very large current draw on the power supply for a few corresponding to the color temperature setting (STD/
moments. To prevent this, the delay time between COL 1/COL 2) for the currently displayed image.
power-up and degaussing can be set for each monitor
independently.
Level 1 Level 2
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
SYSTEM CONFIGURATION C4 INPUT SELECT
ON SCREEN SET C5 STANDBY MODE
ALIGNMENT C6 DEFAULT CH
EXTEND MENU C7 DEGAUSS DELAY
AFC TIME
RESIDUAL SC SW
ACC SW
CONT/BRT HOLD
COL TEMP SHORT-CUT
42
Constituent Menus of the SET UP / SYSTEM CONFIGURATION Menu
This section describes the functions of the constituent DEGAUSS DELAY: Set the time between power-up
menus of the SET UP/SYSTEM CONFIGURATION and the beginning of degaussing. Enter the desired
menu. time (in seconds).
AFC TIME: Select the AFC time constant (SLOW
Notes or FAST).
Chapter 2 Menus
• The menu numbers (A, B1, C11 and so on) are not RESIDUAL SC SW: Switch the residual switch
displayed on the monitor screen. (OFF or ON).
For details of menu numbers, see page 20. ACC SW: Switch the ACC switch (OFF or ON).
• An arrow (÷) following the description of an item CONT/BRT HOLD: Select the contrast and
or setting in each menu indicates another menu which brightness settings to the center or adjusted value
appears or an operation which is executed when you after adjusting the white balance or auto
select that menu item or setting. If the description of adjustment of CONTROL PRESET (OFF or ON).
an item or setting is not followed by an arrow, it ON: The contrast and brightness are set to the
indicates that selecting the item or setting finishes the value before adjusting.
setting operation. OFF: The contrast and brightness are set to the
center value (1000) after adjusting.
[C4] SYSTEM CONFIGURATION menu COL TEMP SHORT-CUT: Assign the shortcut
Set each of the various items. function to the MANUAL menu of the COLOR
INPUT SELECT: Select the channel number entry TEMP ADJ menu to [F2] key (OFF or ON).
method (DIRECT or 10KEY). ON: Assigns the shortcut to the MANUAL menu
(In the explanation below, x and y represent any of the COLOR TEMP ADJ menu.
digit between 1 and 9.) OFF: Do not assign the shortcut to the
DIRECT mode: To select channel x, press the x MANUAL menu of the COLOR TEMP ADJ
button. To select channel xy (a two-digit menu.
channel number), press the 0, x, and y buttons
in this order.
10KEY mode: To select channel x, press the x
button, then the ENTER button. To select
channel xy (a two-digit channel number), press
the x, y, and ENTER button in this order.
When multiple monitors are connected by a serial
remote connection, this setting will be common to
all the monitors. It is not possible to change the
setting for individual monitors.
STANDBY MODE: Select the power-up condition
when the MAIN POWER switch is turned on
(OFF or ON).
ON: Standby mode
OFF: Operation mode
DEFAULT CH: Select the power-up input channel
(LAST or CH xx).
LAST: Set the channel to the channel that was
selected at the time the power was last turned
off.
CH xx: Set the channel to a specific channel
number.
43
Setting the Screen Display — ON SCREEN SET
Menu
Overview
The ON SCREEN SET menu is used to select the type (1) The VITC or user bit from the input signal
of information that will be displayed on the screen and (2) Caption vision
how that information will be displayed. The types of (3) SDI signal ancillary data blanking (when using the
information that can be set are as follows. BKM-20D/21D)
(4) Channel number and name
Chapter 2 Menus
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5 VITC C51 VITC
ALIGNMENT C6 USER BIT
EXTEND MENU C7
CAPTION VISION C52 CAPTION 1
CAPTION 2
ANCILLARY DATA TEXT 1
TEXT 2
OFF
CH NO C53 AUTO
CH NAME ON
OFF
This section describes the functions of the constituent [C5] ON SCREEN SET menu
menus of the SET UP/ON SCREEN SET menu. Select items to be displayed on the screen.
VITC...: Select whether or not to display the VITC
Notes or user bit data contained in the input signal. ÷
• The menu numbers (A, B1, C11 and so on) are not [C51]
displayed on the monitor screen. CAPTION VISION...: Select whether or not to
For details of menu numbers, see page 20. display the caption, and select the display mode.
• An arrow (÷) following the description of an item ÷ [C52]
or setting in each menu indicates another menu which ANCILLARY DATA: Select whether or not to
appears or an operation which is executed when you display the ancillary data in the serial digital
select that menu item or setting. If the description of signal (OFF or ON).
an item or setting is not followed by an arrow, it CH NO...: Select the display mode of the channel
indicates that selecting the item or setting finishes the number. ÷ [C53]
setting operation.
44
CH NAME...: Select the display mode of the channel
name. ÷ [C53]
VITC POSITION...: Select the display position for
the VITC data. ÷ [C54]
CH NO POSITION...: Select the display position
for the channel number. ÷ [C54]
CH NAME POSITION...: Select the display
position for the channel name. ÷ [C54]
Chapter 2 Menus
[C51] VITC menu
Select whether or not to display the VITC and user bit.
VITC: OFF or ON
USER BIT: OFF or ON
45
Convergence Adjustments — ALIGNMENT Menu
Overview
The ALIGNMENT menu is used for adjusting
convergence and geometry.
Level 1 Level 2
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6 ROTATION (1/4)
EXTEND MENU C7
H PIN (2/4)
H CV R C (4/4)
46
[C6](2/4) ALIGNMENT menu (2/4) [C6](4/4) ALIGNMENT menu (4/4)
Adjust each item with the UP and DOWN buttons or Adjust each item with the UP and DOWN buttons or
PHASE knob. PHASE knob.
H PIN: Correct side pincushion distortion. H CV R C: Adjust horizontal convergence at the
H PIN BAL: Correct the balance of side pincushion center right of the screen.
distortion. H CV R T: Adjust horizontal convergence at the top
H CORNER PIN: Correct pincushion distortion at right of the screen.
the corner of the picture. H CV R B: Adjust horizontal convergence at the
Chapter 2 Menus
H CENTER PIN: Correct center bow distortion. bottom right of the screen.
H MID PIN: Correct pincushion distortion at the H CV R M T: Adjust horizontal convergence at the
middle of the picture. middle right between the top and the center of the
H KEY: Correct trapezoid distortion. screen.
H KEY BAL: Correct the balance of trapezoid H CV R M B: Adjust horizontal convergence at the
distortion. middle right between the bottom and the center of
H LIN: Correct horizontal linearity. the screen.
H LIN BAL: Correct the balance of horizontal H CV L C: Adjust horizontal convergence at the
linearity.Monitor Memory Card Data Operations center left of the screen.
H CV L T: Adjust horizontal convergence at the top
[C6](3/4) ALIGNMENT menu (3/4) left of the screen.
Adjust each item with the UP and DOWN buttons or H CV L B: Adjust horizontal convergence at the
PHASE knob. bottom left of the screen.
V STATIC CONV: Adjust vertical static H CV L M T: Adjust horizontal convergence at the
convergence. middle left between the top and the center of the
V CONV TOP: Adjust vertical convergence at the screen.
top of the screen. H CV L M B: Adjust horizontal convergence at the
V CONV BOT: Adjust vertical convergence at the middle left between the bottom and the center of
bottom of the screen. the screen.
H STATIC CONV: Adjust horizontal static
convergence.
H CONV C T: Adjust horizontal convergence at the
top of the screen.
H CONV C B: Adjust horizontal convergence at the
bottom of the screen.
H CV C M T: Adjust horizontal convergence at the
middle between the top and the center of the
screen.
H CV C M B: Adjust horizontal convergence at the
middle between the bottom and the center of the
screen.
47
Using Extended Functions — EXTEND MENU
Overview
The following 4 functions can be executed with the (3) Restart the monitor.
EXTEND menu. (4) Automatically adjust the setup level and 100 IRE
level of the internal white signal which is used in
(1) Restore factory default data for installed boards. the COLOR TEMP ADJ menu [B].
(2) Write monitor setting and adjustment data to the
Chapter 2 Menus
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
EXTEND MENU C7 ENTER PASSWORD RE-LOAD FACTORY SLOT1 CONTROL
C71 DATA C711 SLOT2 SDI 4:2:2/4 FSC1)
SLOT6 VIDEO AMP C7111 Confirmation
SLOT7 DEFLECTION message2)
SLOT9 POWER
SUPPLY
1) This is displayed when the BKM-21D is installed in the SLOT 2. 3) A message appears, requiring your confirmation. If you select
2) A message appears, requiring your confirmation. If you select OK, data is read out from the monitor memory card. If you
OK, data is reset and the monitor is automatically turned off and select CANCEL, then you will be back in the MEMORY CARD
on again. If you select CANCEL, then you will be back in the menu [C712] .
RE-LOAD FACTORY DATA menu [C711].
48
Constituent Menus of the SET UP / EXTEND Menu
Chapter 2 Menus
displayed on the monitor screen.
ITS FACTORY SETTING
For details menu numbers, see page 20.
AND MONITOR WILL RESTART
• An arrow (÷) following the description of an item
ARE YOU SURE?
or setting in each menu indicates another menu which
appears or an operation which is executed when you OK : ENTER KEY
select that menu item or setting. If the description of CANCEL : MENU KEY
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the OK: To continue, press the ENTER button. ÷
setting operation. Resets the data and automatically turn the monitor
off and on again.
CANCEL: To cancel, press the MENU button. ÷
[C7] EXTEND menu
Returns to the RE-LOAD FACTORY DATA
Enter the password (ENTER PASSWORD [C71]).
When the correct password is entered, the following menu. ([C711])
item appears. Choose the function to execute.
RE-LOAD FACTORY DATA...: Restore factory [C712] MEMORY CARD menu
default data for the board installed in the selected Insert the monitor memory card into the MEMORY
slot. ÷ [C711] CARD slot and select the operation to perform.
MEMORY CARD...: Read and write setting and BACK UP SYSTEM DATA...: Write the data to the
adjustment data by using the monitor memory monitor memory card. ÷ [C7121]
card. ÷ [C712] RE-STORE SYSTEM DATA...: Read the data from
RE-START MONITOR: Restart the monitor. ÷ the monitor memory card. ÷ [C7122]
[C713]
Notes
ADJ INT SIGNAL: Automatically adjust the
SETUP level and 100 IRE level of internal • Before a monitor memory card can be used, it must
signals. ÷ [C714] be formatted it with the FORMAT menu ([D4]).
• System data and memory card data ([D]) cannot be
[C711] RE-LOAD FACTORY DATA menu stored on the same memory card. To store memory
Select a slot where a board is installed to reload factory card data, use another memory card.
default data to the board. ÷ [C7111] • The BKM-12Y monitor memory card has a capacity
of 256 Kbytes. It can store either system data for up
Note to 8 monitors or 38 files of memory card data.
You can only select slots 6 and 7. However, when the
optional board has been installed, you can also select [C7121] BACK UP SYSTEM DATA menu
slot 2. While the system is writing the data, a “–” mark blinks
at the top right of the menu. (It takes some time to save
the data.)
49
Using Extended Functions — EXTEND MENU
OK : ENTER KEY
CANCEL : MENU KEY
50
Monitor Memory Card Data Operations
— MEMORY CARD Menu
Overview
Operations on monitor memory card data are
performed with the MEMORY CARD menu.
Chapter 2 Menus
Main menu Level 1 Level 2 Level 3
51
Monitor-to-Monitor Data Copy — COPY Menu
Overview
When multiple monitors are connected via their serial
remote ports, data can be shared between the monitors
by data copy. The data copy from one monitor to
another is accomplished with the COPY menu.
Chapter 2 Menus
52
Displaying Information About the Monitor
— STATUS Menu
Overview
The STATUS menu is used to view general data about
the monitor and information about signals assigned to
the slots in the rear panel.
Chapter 2 Menus
Main menu Level 1 Level 2 Level 3
SERIAL NO
53
Selecting the Monitor to Control — ADDRESS
Menu
A L L P O W E R O N
A L L P O W E R O FF
Displaying the ADDRESS Menu
D I S P L A Y M O N IT O R A D D R E SS
D I S P L A Y G R O UP A D D R E S S
Press the ADDRESS button. S E T U P P V M ( BK M - 1 0 3 )
The ADDRESS button lights, and the ADDRESS ADDRESS Menu
menu is displayed on the screen.
Settings made with the menu items are as follows:
Item Function
SINGLE Control only a specified monitor. Enter the monitor address number.
GROUP Control only a specified monitor group. Enter the group address number.
ALL Control all monitors.
ALL POWER ON Turn all connected monitors on.
ALL POWER OFF Turn all connected monitors off.
DISPLAY MONITOR ADDRESS When this item is selected, each connected monitor displays its monitor address on its
screen.
DISPLAY GROUP ADDRESS When this item is selected, each connected monitor displays its group address on its screen.
SET UP PVM (BKM-103) Transfer the INPUT CONFIG settings of a BVM monitor to a PVM monitor. The BKM-103
Serial Remote Interface Kit must be installed in the PVM monitor, and the monitor address
of the PVM monitor must be selected using the SINGLE menu item.
54
Cancelling the Remote Control Short-cut Function in the
Mode ADDRESS Menu
To cancel the remote control mode, press the When selecting the monitor, short-cut function will
ADDRESS button. enable to select the target monitor without using the
items in the ADDRESS menu. The operation
procedure is as follows.
Chapter 2 Menus
Exiting the ADDRESS Menu To select the monitor in the SINGLE mode
To exit the ADDRESS menu, press the ADDRESS
button or the MENU button.
1 Press the ADDRESS button.
55
Specifications
Chapter 3 Appendix
General Effective picture size:
267 × 200 mm (10 5/8 ×
System 525 lines, 60 fields per second 7 7/8 inches) (w/h)
interlaced 331 mm (13 1/8 inches) (diagonal
625 lines, 50 fields per second size)
interlaced CRT protection: EHT (extremely
CRT Super fine pitch Trinitron high tension) protectiontype
BVM-20F1U/20F1E/20E1U/ Warm-up time: approx. 30 minutes
20E1E Anode voltage: 25 kV with no
Aperture grille pitch: 0.3 mm beam current
(BVM-20F1U/20F1E) or Nominal chromaticity coordinates:
0.25 mm (BVM-20E1U/
Chapter 3 Appendix
20E1E), 90 degree deflection, SMPTE phosphor (BVM-14F1U/
14E1U)
30.6 mm diameter in-line gun.
x y
Effective picture size:
R 0.630 0.340
387 × 291 mm (15 1/4 ×
G 0.310 0.595
111/2 inches) (w/h)
483 mm (19 1/8 inches) (diagonal B 0.155 0.070
size) EBU phosphor (BVM-14F1E/14E1E)
CRT protection: EHT (extremely
x y
high tension) protection type
R 0.640 0.330
Warm-up time: approx. 30 minutes
Anode voltage: 27 kV with no G 0.290 0.600
beam current B 0.150 0.060
Nominal chromaticity coordinates: Power requirements
100 to 240 V AC, 10%, 50/60 Hz
SMPTE phosphor (BVM-20F1U/ Power consumption
20E1U)
BVM-20F1U/20F1E/20E1U/
x y
20E1E: 120 W
R 0.630 0.340 When an optional adaptor is
G 0.310 0.595 installed: 200 W
B 0.155 0.070 BVM-14F1U/14F1E/14E1U/
Error: less than ±0.005 14E1E: 110 W
When an optional adaptor is
EBU phosphor (BVM-20F1E/20E1E) installed: 145 W
BVM-14F5U/14F5E/14E5U/
x y
14E5E: 110 W
R 0.640 0.330
When an optional adaptor is
G 0.290 0.600 installed: 175 W
B 0.150 0.060 Peak inrush current
Error: less than ±0.005 (1) Power ON, current probe method:
55A (240V) (BVM-20F1E/20E1E/14F5E/
BVM-14F1U/14F1E/14E1U/ 14E5E/14F1E/14E1E)
14E1E//14F5U/14F5E/14E5U/ (2) Hot switching inrush current, measured in
14E5E accordance with European standard
Aperture grille pitch: 0.25 mm EN55103-1: 50A (230V) (BVM-20F1E/
(BVM-14F1U/14F1E/14F5U/ 20E1E), 38A (230V) (BVM-14F5E/14E5E/
14F5E) or 0.22 mm (BVM- 14F1E/14E1E)
14E1U/14E1E/14E5U/14E5E),
90-degree deflection, 29.4 mm
diameter in-line gun.
57
Specifications
280 (111/2)
265 (101/2)
257 (101/8)
BVM-14F5U/14F5E/14E5U/14E5E:
482 × 280 × 573 mm (19 × 111/8 ×
22 5/8 inches)
4 (3/16)
(w/h/d)
Chapter 3 Appendix
Dimensional drawing
BVM-20F1U/20F1E/20E1U/20E1E Mass BVM-20F1U/20F1E/20E1U/
Unit: mm (inches)
20E1E: approx. 37 kg (81 lb
444 (171/2)
9 oz)
410 (161/4) BVM-14F1U/14F1E/14E1U/
14E1E: approx. 22 kg (48 lb
(3 5/8)
90.3
8 oz)
BVM-14F5U/14F5E/14E5U/
14E5E: approx. 25 kg (55 lb
1 oz)
414 (16 3/8)
Input/output Connectors
high impedance
BVM-14F1U/14F1E/14E1U/14E1E Y: 1 Vp-p ±6 dB, positive, high
Unit: mm (inches)
impedance
346 (135/8)
R–Y/B–Y: 0.7 Vp-p ±6 dB,
330 (13)
positive, high impedance
Sync input BNC type, 1 (with loop-through
output)
280 (111/2)
265 (101/2)
257 (101/8)
75-ohm termination)
Remote control OPTION
Mini-DIN 8-pin, 1
CONTROL UNIT
D-sub 9-pin, 1 (only on BVM-
20F1U/20F1E/20E1U/20E1E/
14F1U/14F1E/14E1U/14E1E)
REMOTE 1
D-sub 9-pin, 1 (with loop-
through output), RS-485 serial
interface
58
REMOTE 2 Convergence error
D-sub 9-pin, 1 (with loop- Within a central area bounded by a
through output) circle with a diameter equal to the
ISR picture height:
D-sub 9-pin, 1 Less than 0.4 mm (BVM-20F1U/
20F1E/20E1U/20E1E)
Video Signal Less than 0.3 mm (BVM-14F1U/
14F1E/14E1U/14E1E/14F5U/
Differential gain Less than 2% (for luminance from 14F5E/14E5U/14E5E)
0 to 100 cd/m2) Outer area of the above-mentioned
Differential phase Less than 2˚ (for luminance from 0 circle:
to 100 cd/m2) Less than 0.7 mm (BVM-20F1U/
Chapter 3 Appendix
Frequency response 20F1E/20E1U/20E1E)
50 Hz to 10 MHz, ±1 dB Less than 0.6 mm (BVM-14F1U/
DC restoration Back porch type 14F1E/14E1U/14E1E/14F5U/
Black level fluctuation: less than 14F5E/14E5U/14E5E)
1% for 10 to 90% APL input Standard luminescence
signal variation. 100 cd/m2 (at standard 1 Vp-p
100% white signal)
Raster size stability
Synchronization Less than 1% of picture height (at
100 cd/m2 peak luminescence, 10
AFC time Constant to 90% APL)
0.5 ms (fast mode) Scan delay Horizontal: Approx. 1/4 line
2 ms (normal mode) Vertical: Approx. 1/2 field
Line pull range/line hold range Resolution (at screen center, 100 cd/m2 luminescence)
Greater than ±500 Hz (with 0.5 ms BVM-20F1U/20F1E: 900 TV lines
AFC time constant) BVM-20E1U/20E1E: 1000 TV
Vertical blanking time lines
Normal: less than 1 ms. BVM-14F1U/14F1E/14F5U/
Underscan: less than 0.8 ms 14F5E: 800 TV lines
Horizontal blanking time BVM-14E1U/14E1E/14E5U/
Less than 10 µs 14E5E: 900 TV lines
59
Specifications
Accessories Supplied
5 3
8 6
Signal Pin Number Pin Number Signal
N.C. 1 1 H SYNC
GND 2 2 V SYNC
RXD 3 3 RTS
TXD 4 4 GND
GND 5 5 N.C.
N.C. 6 6 TXD
7 +5V
8 RXD
60
Connection cable for Minolta CA-100 probe
5 3
14 25 8 6
Signal Pin Number Pin Number Signal
N.C. 1 1 H SYNC
TXD 2 2 V SYNC
RXD 3 3 RTS
Chapter 3 Appendix
RTS 4 4 GND
CTS 5 5 N.C.
N.C. 6 6 TXD
GND 7 7 +5V
N.C. 8–25 8 RXD
Connection cable for Philips PM 5639 probe (corresponds to Philips PM 5639/64 cable)
5 3
8 6
Signal Pin Number Pin Number Signal
+5V 1 1 H SYNC
N.C. 2 2 V SYNC
RXD 3 3 RTS
TXD 4 4 GND
N.C. 5 5 N.C.
GND 6 6 TXD
7 +5V
8 RXD
61
Specifications
5 3
9 15 8 6
Signal Pin Number Pin Number Signal
N.C. 1 1 H SYNC
RXD 2 2 V SYNC
TXD 3 3 RTS
N.C. 4 4 GND
Chapter 3 Appendix
N.C. 5 5 N.C.
N.C. 6 6 TXD
GND 7 7 +5V
N.C. 8–15 8 RXD
62
The material contained in this manual consists of
information that is the property of Sony Corporation and is
intended solely for use by the purchasers of the equipment
described in this manual.
Sony Corporation expressly prohibits the duplication of any
portion of this manual or the use thereof for any purpose
other than the operation or maintenance of the equipment
described in this manual without the express written
permission of Sony Corporation.