Elektronikon BASIC G7 15 Procedure and QA 201802 Ed00
Elektronikon BASIC G7 15 Procedure and QA 201802 Ed00
Elektronikon BASIC G7 15 Procedure and QA 201802 Ed00
ON G7-15
GUIDELINES & FAQ – ED 00
Product Company Brendola
Atlas Copco IT
2
GENERAL INFO
Q & A from the field
4
ES 99:
• Designed in 1995
• Led status visualization
• No display for an easy and intuitive visualization
• No running/load hours
• No service advices
• No pressure setting, Electro-Pneumatic machine
4
5
Technical features
– Power supply 12VAC (±15%): 12VDC is not allowed
– Protection Grade (IP grade) IP54 front, IP20 back
– Connections via connectors
– Temperature Range:
‒ Operating -10°C…+60°C
‒ Storage -20°C…+70°C
– Permissible Humidity RH 85%, no condensation @ nominal reference
6
3 LED ’s
– Red (alarm led), software controllable
– Yellow (service led), software controllable = lit when the service interval is elapsed
– Green (power led), not software controllable = lit when power to controller is OK
7
Unloading
When the working pressure reaches the maximum value, the solenoid valve is de-energized by venting the control air
– Inlet valve closes completely and unloading valve opens completely
– Compressor runs unloaded (0% output).
Elektronikon basic will stop the compressor after a variable period of unloaded operation using following rules:
– If the unloading pressure is reached after the first start and if there is no air consumption, the compressor will run unloaded during
30 seconds and then stops
– If the compressor is stopped manually, it stops after 30 seconds of unloaded operation
– To reduce the energy consumption, the compressor stops as soon as a certain time is elapsed → it is calculated as follows:
‒ Compressor cannot go over the number of hourly activation (10#/hr = cycle of 6 minutes)
‒ If the calculated virtual temperature of the motor (that increases each motor start) is above the safety limit, the compressor still goes in unload mode
until it is decreased below the safety limit
‒ If there is no pressure request at the end of the cycle & the pressure is > 2/3 of pressure band, compressor stops
‒ If there is a pressure request at the end of the cycle & the pressure is < 2/3 of pressure band, compressor goes in loading mode
The compressor will automatically restart when the net pressure drops to the minimum limit
12
Pressure
transducer
Other Inputs
– Emergency Stop
– Overload Motor
– Auxiliary Relay
– Remote Start/Stop
13
Power contactors
Activators
Options
14
UNIT PROTECTION
Shut Down Conditions
UNIT PROTECTION
Shut Down Conditions
SERVICE WARNING
What’s new?
The new controller has the service warning function in order to inform customer about service
plan
When the timer exceeds the programmed service interval, alarm LED (6) is blinking with a
following screen
– SErU means “SERVICE”
17
GENERAL OVERVIEW
Access the MAIN MENU
GENERAL OVERVIEW
Structure of the MAIN MENU
PROGRAMMING
•
DATA •
REGULATION PRESSURE
TIMER (MAINTENACE) TEST INFO
• DISPLAY
• CONTROL
• ES99 MODE
• UNLOADING
• WIZARD
• PASSWORD
19
GENERAL OVERVIEW
dAtA
d.1: Calling up running
hours
– Tot nr of working hours (time
of output line=on)
GENERAL OVERVIEW
dAtA
d.3: Calling up module hours
– Tot nr of hours with controller
powered
GENERAL OVERVIEW
dAtA
d.5: Calling up load relay
– Tot nr of solenoid valve
activation
GENERAL OVERVIEW
dAtA – sum up
GENERAL OVERVIEW
ProG
rEG.P: Calling up / Modifying pressure band selection – PrSL
rEG.P: Calling up / Modifying pressure band settings – LPr.1, uPr.1, LPr.2 and uPr.2
24
GENERAL OVERVIEW
ProG
GENERAL OVERVIEW
ProG
GENERAL OVERVIEW
ProG
After any power failures and before restarting, the compressor will wait for a fixed time.
– Factory set up for delay is 30 seconds (editable ONLY with password up to 120 seconds)
– The display will show the countdown:
27
WIZARD PROCEDURE
It is possible reinitialize the controller through the WIZARD procedure
WIZARD PROCEDURE
Guidelines
Check the dataplate
– Unit version: FF (with dryer) or PACK (without dryer)
– MAX working pressure and SCALE
– Version of electrical standard
WARNING: DO NOT SHUT DOWN THE POWER SUPPLY DURING THE PROGRAMING.
In case of interruption during this step, the controller will be NOT full programmed.
30
WIZARD PROCEDURE
How to choose the correct «program»
STAR
T
1) IS THISNO
AN «APH» UNIT? YES
BAR
2) WHAT PSI
IS THE PRESSURE PSI
UNIT? BAR
1 3) SEE TABLE
2 3 4
31
WIZARD PROCEDURE
MAX PRESSURE BAR
TABLE 1 PACK 7,5 10 13
G7 G11 G15
FF 7,25 9,75 12,75
MAX PRESSURE PSI
PACK d107 d132 d157 d182
G7 G11
FF d103 d128 d153 d178
TABLE 2
PACK S107 S132 S157 S182
G15
FF S103 S128 S153 S178
MAX PRESSURE
PSI
FOR APH UNITS
PACK S107 S132 S157 S182
TABLE 3 G7 G11 G15
FF S103 S128 S153 S178
MAX PRESSURE
BAR
FOR APH UNITS
7,4 9,1 10,8 12,6
TABLE 4 PACK S107 S132 S157 S182
G7 G11 G15
7,1 8,8 10,6 12,3
FF S103 S128 S153 S178
WARNING: DO NOT USE A DIFFERENT PRESSURE SETTING FROM THE DATAPLATE!
‒ IT’S A SAFETY RISK AND COMPRESSOR COULD BE DAMAGED
32
3. Would Smartlink kit be mounted? What can be retrieved on the web portal?
– Smartlink is not compatible with Elektronikon® basic but only with Mk5
9. Is there DSS timer in the new Elektronikon® basic like we have in the MK5 modules? Or fix
unload time (if yes, what is that time?)? What are the max starts/hour?
– There is no DSS function but here we have a virtual algorithm
– Min unload time is fixed and cannot be changed: 30 seconds
– Factory setup of motor start/stop is 10#/hr: you can decrease (i.e 6#) but not increase
If nHCA = 0 (no restart per hour), unit is always in UNLOAD mode and never stops
12. Is it possible to set an digital input for different pressure band on Elektronikon® basic?
– Customer requests a contact for secondary pressure band settings activation: when this contact off,
compressor works as normal pressure band
– Unfortunately this is not possible
38
15. Is it possible to disable the virtual algorithm and just let the unit load/ unload on the
pressure settings? Virtual algorithm creates too long idle time.
– You can NOT disable virtual algorithm related to idle time
40