PROGRAMMING MANUAL
(Translation of the original instructions)
TECHNICAL SPECIFICATIONS
• Power supply 3~+PE 400V±10% 50-60Hz;
• Alarm warning light [ 1 ];
• Maintenance warning light [ 2 ];
• Emergency STOP button [ 3 ];
• Button to turn on centralized vacuum system (ON) [ 4 ]
• Button to turn off centralized vacuum system (OFF) [ 5 ]
• LCD with backlighting (128x64dots) [ 6 ];
• Interlocked isolating switch [ 7 ];
• Function keys [ 8 ];
• Manual/Automatic selector, emergency pump (for hospital cabinet only) [ 9 ];
• Absolute pressure sensor 1100÷0 mbar ±0.5% FS on tank;
• Current meter protection (TA) for industrial use;
• Protection fuses;
• Buffer battery (6 years life time with not supplied switchboard)
• Protection rating of cabinet IP44;
• Protection rating of control panel IP65;
• Operating temperature from +12°C to +40°C;
• Humidity: max. 50% at +40°C;
• Rated insulation voltage 450V~;
• Rated voltage of auxiliary circuits:
♦ Control circuits: 12-24V~
♦ Coils for energizing remote switches: 24V~
Numbers between brackets [ ] refer to the front view drawing of the switchboard cabinet illustrated below.
CABINET FOR INDUSTRIAL USE CABINET FOR HOSPITAL USE (UNI EN ISO 7396-1)
Centralized vacuum systems create and maintain vacuum in a system by means of information that comes from an
electronic control unit by means of an absolute pressure sensor installed on the tank.
Each system has a START parameter and a STOP parameter. The software installed in the PLC controls operation
of the vacuum pump(s) automatically depending on the type of system and guarantees even wear and tear of
pumps (for systems with more than one pump).
Programming and management of MENU parameters are protected by three password levels. Thanks to this
precaution, staff members can work on functions that fall within their area of qualification.
• Password level 0 (Operator)
• Password level 1 (Maintenance)
• Password level 2 (Factory)
DISPAY VISUALIZATION
After the vacuum unit is supplied, the PLC display will show as follows:
OFF
999 mbar (Abs.)
I
MENU MIS.
0
F1 F2 F3 F4
After the first start of the vacuum unit we advise to press the emergency button before entering the configuration
parameters in order to familiarize with the use of PLC functions and setting and to avoid the unwilling start of the
unit.
Make sure that the emergency STOP button is not pressed and start the unit pressing the green button I (ON).
The unit will turn on and the display will show the following information:
P1 250 Stop
!
mbar
P2 310 (Abs.)
P3
I
350 Start !
P1 Pump off.
P1 Pump running.
! Active alarm.
Maintenance signal.
FUNCTION KEYS
Depending on the page you have opened, keys F1 – F2 – F3 – F4 have different meanings, which are shown on the
display.
• START: absolute pressure on the start of the unit.
• STOP: absolute pressure on the stop of the unit.
• MENU: access to PLC menu.
• MIS.: access to monitoring parameters of the unit.
• ENTER: data confirmation/access to parameter or submenu.
• ESC: exit from parameter or submenu.
• DEL: data cancellation.
• ALL: access to visualization of the signalled alarm.
• : move of the selected item or increment/decrement of the value of a parameter.
• move of the selected item or increment/decrement of the value of a parameter.
When an alarm is active, the displayed function above button F4 starts flashing and “Measurement” (MIS) and
“Alarms” (ALL) appear alternately (see Section 9- Alarms).
When the “Remote Trminal” is connected and upon condition that there are no alarms, the display will be showing
the letters "RT" (Remote Terminal) in the alarm triangle [ Kit available upon demand ].
During the functioning of the unit it is possible to select the password level 0 parameters (Operator), directly from
the aboved described frame, in order to visualize or modify them.
• To modify START pressure, hold F1 down for two seconds (the setting will start flashing). Press F1 or F2 ( )
to modify the setting and press F3 (ENTER) to save your setting, which will stop flashing. The entering of this
value may also be set by START 1st level (see paragraph 4.3)
• To modify STOP pressure, hold F2 down for two seconds (the setting will start flashing). Press F1 or F2 ( ) to
modify the setting and press F3 (enter) to save your setting, which will stop flashing. The entering of this value
may also be set by STOP 1st level (see paragraph 4.2)
• Use button F4 (Measurements – MIS.) to display the following information for each pump:
Oil temperature (*).
Power draw.
Hours of work.
Oil level check (*).
Oil and filter replacement.
Air filter and exhaust filter replacement (*).
Numbers of startups per hour.
(*) This parameter is displayed only if the sensor kit obtaining the exhaust filter, temperature and oil level efficiency
is installed [ it is an optional kit ].
ANTI-PANIC FUNCTION
Irrespective of the section of the menu, the pages or settings you are working on, if you wait 30 seconds without
pressing a key, you will return to the main page and none of your modifications will be saved.
During the display and/or setting stage, the PLC is active. This means that any alarms will be displayed in the main menu.
NOTE: the functioning of alarms prevents the unit to be activated till the alarms are not deactivated
(see 9 – Alarms).
MENU LIST
To gain access to the PLC configuration parameter setting page from the main menu, press the F3 key (MENU)
and scroll through the parameters you wish to display or modify using F1 and/or F2 keys ( or ).
Here below is a list showing the order of the menus and the relative password levels.
Note: with a level 0 password (Operator), you will not be allowed to open a sub-menu subject to a level 1
(Assistance) or 2 password (Factory). The message "Protected parameter" will appear on the display.
Similarly, it is not allowed to enter the sub-menu of level 2 password (Factory) from level 1 password (Assistance).
1 - PASSWORD
1.1 - SERVICE
1.2 - FACTORY
0XX 0XXX
↑ ↓ ENTER ESC ↑ ↓ ENTER ESC ↑ ↓ ENTER ESC
From the main menu, press F1 and/or F2 ( or ) to select “Password" and confirm with F3 (ENTER).
Still using the same buttons, select the password level and press F3 to confirm. The password level is shown on the
first line. The second line features '0' (highlighted) and X X [Service] or 0 (highlighted) and X X X [Factory].
Default settings of password levels:
• Service password = 111 factory setting.
• Factory password = set by the manufacturer.
If the password is correct, the main menu will appear otherwise the message "Wrong password" will appear for 5
seconds and the page previously displayed will appear.
If you have forgotten your password, turn the system off and on again, and hold keys F3 down contemporaneously
and F4 for 5 seconds. During this lapse of time, the message "Password" will be flashing on the display; when the
message stops flashing, the default settings of the passwords have been resumed.
To modify password Assistance: once entered menu 1.1. – ASSISTANCE following the above mentioned
indications, the main menu is displayed again and the option 1 “Change Password” appears. Enter the sub-menu
pressing F3 (ENTER) and then write the new password.
2 – DISPLAY SETUP
ENGLISH P mbar
P mbar °C Mon 01/01/2011
10:23
°C - +
Daylight time: Yes
- + Set clock
ENTER ESC ENTER ESC ENTER ESC
In this section it is possible to visualize (pressing F1 e F2 - / ) and/or modify the following parameters:
• Language (Italian / English / French / German / Spanish / Portuguese) – [ default setting: Italian ].
• Unit of measurement of pressure (mbar (Abs.) / PSI / mmHg) – [ Default setting: mbar (abs.) ].
• Temperature (°C / °F) – [ Default setting: °C ]
• Brightness of display.
• Setting time / day / month / year.
3 – UNIT SETUP
3.1 - PUMP CAPACITY
Setting range: from 50 to 50,000 litres/minute (5 l/min. steps).
Default setting: 1000 l/min (to be modified depending on reference unit).
3.6 – EMERGENCY PUMP TIME [this is only active on vacuum systems Duplex and Triplex]
Permissible setting: YES / NO.
Default setting: NO.
If setting is NO: pumps will work in accordance to the ON / OFF parameters that have been set.
If setting is YES: Setting range from 1 to 60 min. (default setting 5 min.). The vacuum system works as follow:
In case the air entering the system prevents the pump to reach the STOP pressure value, the reserve pump (the
one with less working hours) starts working after that the set time (counted from the turning on of the pump) has
elapsed. When the second pump starts working , the countdown of the set time begins again and if at the deadline
the pressure has not reached the STOP pressure value yet, the third pumps starts working.
In this way it is possible to equilibrate the working hours of the pumps.
3.9 – PUMPS WORKING TIME BALANCE [this is only active on vacuum systems Duplex and Triplex]
Permissible setting: YES / NO.
Default setting: NO.
This parameter allows the PLC software to manage the work of each pump in order to balance the working hours.
3.10 - RESTART
Permissible setting: MANUAL / AUTOMATIC.
Default setting: MANUAL.
If setting is MANUAL: if a power failure occurs and the switchboard goes off, when power is resumed, the PLC
puts itself in OFF condition and the "No Power" alarm message appears. The pumps of the vacuum system are off.
If setting is AUTOMATIC: if a power failure occurs and the switchboard goes off, when power is resumed, the
vacuum system starts automatically depending on the pressure of the system.
DANGER: considering the risk relating to use of this operation, read the "Instructions for use"
paragraph of the use and maintenance manual with particular care!
3.11 – EMERGENCY PUMP [this is only active on vacuum systems Duplex and Triplex]
Permissible setting: YES / NO.
Default setting: NO.
If setting is YES: setting range from 1 to 3 (default setting: 1). This parameter allows the selection of the pump,
which is NOT used during the normal functioning of the unit, but only in case a working pump fails or a pump is
momentarily stopped for maintenance.
NOTE: during the first start of the day of the unit the reserve pump is activated for a sigle cycle in order to
verify its correct functioning.
3.18 – ENABLING SENSORS (only if sensor kit is installed, signalling the efficiency of the exhaust filter, oil
temperature and level – available upon demand)
Permissible setting: YES / NO.
Default setting: NO.
If setting is NO: the sensor kit is not fitted to the pump/s and the PLC will not be displaying the following
parameters:
• Temperature parameter and all temperature controls (parameter 5 - Temperature);
• In the main visualization of Measurement menu (MIS) is not active the visialization of the oil temperature of the
pump/s;
• Temperature alarm parameter (STx) (Parameter 9 - Alarms);
• Oil level alarm parameter (LOx) (Parameter 9 - Alarms);
• Pressure switch alarm parameter (PRx) (Parameter 9 - Alarms);
If setting is YES: the sensor kit is fitted to the pump/s and the PLC will be displaying all following parameters are
displayed:
• Temperature parameter (parameter 5 - Temperature);
• In the main visualization of Measurement menu (MIS) is active the visialization of the oil temperature of the
pump/s;
• Temperature alarm parameter (STx) (Parameter 9 - Alarms);
• Oil level alarm parameter (LOx) (Parameter 9 - Alarms);
• Pressure switch alarm parameter (PRx) (Parameter 9 - Alarms);
ATTENTION: if there is no sensor kit fitted to the pump, this parameter must be set to NO otherwise the
PLC will not give the authorisation to start (I - ON) at the vacuum system.
4 – PRESSURES
4.1 - High vacuum alarm (P1)
900
Setting range: from 0 to (P2-25) mbar (Abs.). ALL - P4
5 – OIL TEMPERATURES
The following parameters refer to the temperature of the oil in the tank of the pump/s and allow the visualization of
the temperarture on PLC display only if the sensor kit is installed, showing the efficiency of the exhaust filter, oil
temperature and level.
NOTE: the values of the parameters must be T1>T2>T3>T4.
6 – PUMPS CORRENTS
NOTE: the setting must be entered in PLC following this order 1, A2. A3 and respecting this proportion
A1>A2>A3.
7 - TIMER
Permissible setting: YES / NO.
Default setting: NO.
Thanks to this parameter it is possible to set 3 different daily time slots during which the starting (I – ON) and stop
(0 – Off) of the unit may be planned together with the programming of the 2 different pressure levels (1° and 2°
level; see 4 – Pressures) assigned to each time slot.
If setting is NO: the parameter is deactivated.
If setting is YES: the symbol of the clock (see Display visualizations) appears in the PLC display, either the unit is
working or not.
In case the pressure parameter 2° level is activated (see 3.12 – 4.6 – 4.7) in TIMER menu together with ON and
OFF parameters, the LIV settings will be displayed allowing the control of the 3 time slots of START/STOP
assigned both to 1° and 2° level of pressure.
Activating this parameter, that is, the activation of START (I –ON)/STOP (0 –OFF) by means of the timer, in any
case it is possible to turn the unit on bypassing this set parameter (TIMER), holding I (ON) button down for 5
seconds. When the unit is turned on, it automatically re-starts working respecting the previously saved time slots.
Similarly, press 0 button (OFF) to turn the unit off (in case of unscheduled stop) in TIMER mode.
NOTE: the signal comes from the remote emergency button START/STOP (see 4.8.2 in Use and
Maintenance Manual) and it is active only when TIMER parameter is in NO mode. In other words, when
TIMER parameter is in YES mode, the remote START/STOP function is not active.
8 – MAINTENANCE
If the new setting is lower than the countdown underway, the latter is reset.
The countdown refers to the hours of work of each pump (hours of work are counted down); when the countdown
reaches 0, the relative maintenance alarm is given and the countdown is continued in negative.
Hours are memorised every 15 minutes. If a power failure occurs during the countdown, the 15-minute lapse of time
will not be considered.
With the maintenace message on the display the yellow signal of the optional alarm visualization kit turns on and
RL5 relay contact is closed. (see section 9 – Alarms and vacuum unit maintenance manual).
NOTE: cancel the displayed alarms, once maintenance is carried out. After cancellation of the alarms the
calculation starts again to signal the next maintenance alarm.
9 - ALARMS
The access to this menu section (password level 0 – Operator) allows the visualization of the alarms with relative
codes, meaning, progressive number, cause, date and time of the event.
The memory may contain till 100 alarms and message nr. 101 cancels the first alarm and so on.
If the memory is empty, the message “EMPTY MEMORY” appears.
When an alarm is obtained, in the low right part of the display the symbol of “Alarm Presence” (triangle) appears
and the red Led (Alarm Presence) turns on, RL6 relay on NC is closed and button F4 alternatively changes meaning
from Measurement to Alarm (ALL). Selecting F4 (when on ALL) it is possible to visualize the generated alarm.
OFF
999 mbar (Abs.)
I
P2
P3
mbar
310 (Abs.)
I
! 350 Start !
RELAY STATUS
• RL4 (machine status): relay RL4 is energized when the system is ON or OFF, when maintenance signal (M) is
active and when no alarm is activated.; it is de-energized when block (B) and/or visual alarms (W) are active.
• RL5 (maintenance): relay RL5 is energized when the maintenance signal (M) is active; it is de-energized when
the system is ON or OFF and when block (B) and/or visual alarms (W) are active.
• RL6 (block alarm): relay RL6 is energized when the system is ON or OFF, when maintenance signal (M) is active
and when no alarm is activated; it is de-energized when block (B) and/or visual alarms (W) are active.
RELAY STATUS RL 4 RL 5 RL 6
OFF ON (n.o.) OFF ON
START ON (n.o.) OFF ON
WARNING (W) OFF (n.c.) OFF ON
BLOCK (B) OFF (n.c.) OFF OFF (n.c.)
MAINTENANCE (M) ON (n.o.) ON (n.o.) OFF (n.c.)
NOTE: The AL.B.04 “No power” alarm is displayed only if the system is set up for manual restarting. On the
contrary, the message “Power OFF” appears.
NOTE: Alarm AL.W.01 is displayed when the vacuum system is turned on and when the first pressure check is
performed.
NOTE: When there is a maintenance alarm, press F3 to reset alarm display. However, if the alarm is not reset in
menu 10 - maintenance reset - the alarm message will reappear after 8 hours.
10 - RESET
Entering this section it is possible to reset the below listed parameters as they were programmed by the factory.
• Maintenance
Selecting this parameter all the pumps of the unit are visualized. Choosing a pump the items of the “Maintenance “
menu (check of oil, oil filter and inlet/exhaust filter) appear in the display. Now it is possible to reset the intended
parameter.
• Hours of work
Selecting this parameter all the pumps of the unit are visualized. Choosing a pump the display shows YES/NO for
the relative setting.
NOTE: the resetting of the hours of work has to be used only in case of replacement of a pump or PLC. In case the
counter of the replaced pump is reset to zero, the PLC will make it work till that pump will reach the same working
hours of the other pumps (if settting is YES in “Hour balancing” parameter, see 3.9).
• Alarms
Permissible setting: YES / NO.
Default setting: NO.
Selecting NO: You will return to the previous page.
Selecting YES: The resetting of the alarms is carried out.
NOTE: When resetting has been confirmed, the message “RESETTING” starts flashing. When resetting has been
completed, the message will stop flashing and previous page will appear.
11 – SERIAL PORTS
11.2 – Supervision
NOT active parameter.
11.3 - Modem
This parameter allows the entering of telephone numbers of GSM modem.
This parameter is not active.
12 – SERIAL NUMBERS
In this menu section (protected 2 level password – Factory) the values of the following parameters are entered:
• Serial nr. P1
• Serial nr. P2
• Serial nr. P3
• Vacuum system serial number
• CPU software release
• PLC software release (factory settings)
1
M11 M10 M2 ID5 LO3
OIL LEVEL
M5 ID4 LO2
PROBES
TA1
ID3 LO1
AMPERE
TRANSDUCERS
TA2 M9 1
REMOTE
ID2 STR
TA3 START/STOP
KD1
1
ID8 PR3
NO
M6
PRESSURE
ID7 PR2
PROBES
RL3
ST1
ID6 PR1
TEMPERATURE 1
RL2
ST2 Relay 3
PROBES
M8 Relay 2
M3
ST3 Relay 1
RL1
1
- NO
PRESSURE
TPA Relay 6
+ NC
RL6
TRANSDUCERS
1
NO
N
M4 NC Relay 5
RL5
1 1
RELAY STATUS
WITHOUT
POWER SUPPLY
CONNECTION KEY
Terminal Description Connections
n°1 - Neutral (0 Vac)
n°2 - L12V (12Vac)
M1 Power supply n°3 - L24V (24Vac)
n°4 - L24V EM
n°1 = GND
n°2 = RX
M2 Serial output n°3 = TX
n°4 = +15 Vcc
n°1 = P. n°1
Relay outputs for pump
M3 n°2 = P. n°2
control n°3 = P. n°3
RL4 = n°1 N.C. e n°2 N.O.
Relay output alarms
M4 RL5 = n°3 N.C. e n°4 N.O.
(relay contacts: 2A - 24Vac) RL6 = n°5 N.C. e n°6 N.O.
n°1e2 = ID3 (LO1)
M5 Safety devices n°3e4 = ID4 (LO2)
n°5e6 = ID5 (LO3)
n°1e2 = ID6 (PR1)
n°3e4 = ID7 (PR2)
M6 Safety device n°5e6 = ID8 (PR3)
n°7e8 = ID2 (STR) [remote START/STOP – Only for cabinet for industrial use]
n°1e2 = ST1
n°3e4 = ST2
Temperature probes
M8 n°5e6 = ST3
Pressure transducer n°7 = TPA (negative - white)
n°8 = TPA (positive - brown)
n°1e2 = TA1
M9 Transducers, Ammeters n°3e4 = TA2
n°5e6 = TA3
M10 Front card
M11 Expansion
+15V
GND
RX
TX
1
M11 M10 M2
M5
M9 1
KD1
1
NO
M6
RL3
1
RL2
M8
M3
RL1
1
RL6
M4
RL5
M1
RL4
1 1
Warranty means the free replacement or repair at its own assistance network of any components of the
product that are found to be faulty from the start due to manufacturing defects.
In the event of repair, D.V.P. Vacuum Technology s.p.a. guarantees, exclusively to its own customer, the
identical spare parts for 24 months from the shipping date; once this period has passed, the pieces may no
longer be available on the market, therefore the repairs, even under warranty, may require the payment of a
difference between the product purchased and that installed during the repair. This price will be indicated
to the customer before the repair is carried out, for acknowledgement and acceptance.
D.V.P. Vacuum Technology s.p.a. will do everything reasonable within its power to respect the assistance
times and standard response (20 working days), which may vary according to the distance and accessibility
of the place where the product is located and the availability of the components.
D.V.P. Vacuum Technology s.p.a. will not be held responsible for any direct or indirect losses caused by its
failure to respect the assistance times and will not have any responsibility or contractual or civil obligation
for product faults or for failure to repair the faults in a reasonable period of time.
In the event of irreparable faults, the product will be replaced. The replacement will cause the original
warranty to be extended to the new product, until its expiry date.
The warranty does not cover any parts that appear to be faulty due to negligence and/or carelessness
during use (failure to observe the equipment operating instructions, lack of maintenance), incorrect
installation and/or maintenance, maintenance carried out by unauthorized staff, damage due to transport, or
circumstances which, in any case, cannot be attributed to manufacturing faults on the equipment.
The warranty also excludes all components of the product that have been modified or repaired without prior
written authorisation from D.V.P. Vacuum Technology s.p.a.
The warranty also excludes any faults deriving from improper use, normal wear, galvanic and electrostatic
currents, chemical corrosion, tampering, replacement or elimination of the registration plate.
The warranty does not cover, in any case, faults generated by external causes, such as accidents and
fortuitous events.
D.V.P. Vacuum Technology s.p.a. declines all responsibility to anyone for any damage and, consequence, of
any kind and/or reason, that may derive from the use of the product, as well as for any faults that it may
present.
By way of non-limiting example, it declines all responsibility:
• for any damage that could, directly or indirectly, be caused to people, objects and animals, due to failure
to observe all the instructions indicated in the relevant use and maintenance manual, especially the
indications on the installation, use and maintenance of the equipment;
• for any damage and/or loss caused by faults of deficiencies of products repaired by D.V.P. Vacuum
Technology s.p.a.;
• for any indirect or consequential damage such as, by way of non-limiting example, loss of business,
profits, salaries, payments etc.;
• losses that could have been avoided by the customer by following the advice and instructions from
D.V.P. Vacuum Technology s.p.a..
In any case, the customer waives the right to claim any right and/or demand as well as raising any objection
or promoting any action, inherent to the use of the product.
The warranty is not extended to consumable parts, or faults deriving from: filtering cartridges, blades,
membranes or sealing rings, as well as third party products that are part of the final product.
The transport, removal and subsequent re-installation costs of the repaired or replaced product are,
however, to be entirely borne by the customer.
Cod. 8702032 – 01/09/2016 – R.9 – ( EN )