Walkin Hood
Walkin Hood
Walkin Hood
Features:
• Radiused corner posts and airfoils
for smooth air movement assures high
level of comfort, safety and efficiency.
• 4" thick endwalls provide more
Available Option: interior work space and clean-lined
uncluttered design.
Adjustable Baffles
• Interior baffles designed to
Air Flow and Static Pressure Alarms minimize turbulence and optimize
Service Fittings and Piping containment.
Electrical Fixtures and Wiring • Frameless sashes with full-length
formed steel handle for neat, clean
UL listed when pre-wired per UL 61010A-1 appearance and streamline air
1805 UL classified with Kemglass, Stainless features.
Steel, or Phenolic Resin liner • Low profile PVC sash tracks and
Vapor Proof and Explosion Proof Lighting exclusive sash leveling and
alignment features assure easy-
Stainless Steel Deflector Vane smooth sash operation
Alternate Sash Handles • Large friction-fit interior access
Sash Frame panels provide easy access to
piping and service fittings.
Tempered Sash Glass
• Heavy gauge cold rolled steel
Tissue Screen exterior panels with independent
Fire Extinguisher rigid structural frame.
Distillation Rack • Designed and tested using
ASHRAE 110-1995, BS 7258, and
Sash Stop DIN 12 924 standards.
Stainless Steel Duct Collar
Work Floor & Removable Work Shelf
SAFH-11/09-32
Supreme Air Fume Hood H30
Specifications:
Supreme Air General Purpose Walk-In interior plumbing access panels. collars.) Supreme Air Walk-In Hoods
Fume Hoods are furnished with a Hood exteriors are fabricated of cold are available with either an Open By-
choice of liner and baffles with upper, rolled steel, phosphate coated with a Pass or a Restricted By-Pass for VAV
center, and lower exhaust slots. Each baked chemical resistant, synthetic use. An auxiliary air chamber is
fume hood is complete with two resin finish. The exhaust duct collar is available for use on the Open
counter- balanced, frameless sashes polyethylene, 1115/16" O.D. (8 foot By-Pass hood.
of 1/4" combination safety glass and hoods are furnished with two duct
Available Models:
Dynamic Barrier By-Pass
Features:
• Requires over 60 percent less
exhaust air volume than a
traditional by-pass fume hood.
• Extra large vertical sash design
allows full view into hood interior
and 73" opening height for
apparatus setup.
• Radiused corner posts and airfoils
for smooth air movement assures high
level of comfort, safety and efficiency.
• 4" thick endwalls provide more
interior work space and clean-lined
uncluttered design.
Available Option:
• Low profile sash frame for easy
Service Fittings and Piping access through horizontal panels.
Electrical Fixtures and Wiring • Service ports provide convenient,
UL listed when pre-wired per UL 61010A-1 safe passage for equipment
connections.
1805 UL classified with Kemglass, Stainless
Steel, or Phenolic Resin liner • Exclusive Air Alert 600 Monitor
provides a visual one-hour timeline
Lighting of fume hood performance.
Stainless Steel Deflector Vane • Exclusive static pressure averaging
mechanism provides accurate face
Tempered Sash Glass velocity readings regardless of
Tissue Screen sash opening.
Fire Extinguisher • Quiet fume hood operation, under
40 dBA with properly sized fans
Distillation Rack and ductwork.
Stainless Steel Duct Collar • Designed and tested using
Removable Work Shelf ASHRAE 110-1995, BS 7258, and
DIN 12 924 standards.
SAFH-11/09-34
Dynamic Barrier Fume Hood H52
Specifications:
Dynamic Barrier Supreme Air Walk-In and a frameless lower sash of 1/4" polyethylene, 715/16" O.D. (8 foot
Fume Hoods are furnished with a choice combination safety glass, and an Air hoods are furnished with two duct
of liner and baffles with center and lower Alert 600 Monitor with static pressure collars.)
exhaust slots and interior plumbing averaging. Hood exteriors are Dynamic Barrier Supreme Air Walk-In
access panels. Each fume hood is fabricated of cold rolled steel, Hoods are not designed for use with
complete with a counter balanced, phosphate coated with a baked auxiliary air chambers.
extra large, low-flow narrow framed chemical resistant, synthetic resin
upper sash with six horizontal panels, finish. The exhaust duct collar is
Dynamic Barrier Walk-In Fume Hoods — Low-flow Combination Vertical Rising/Horizontal Sash
Features:
• Radiused corner posts and airfoils
for smooth air movement assures high
level of comfort, safety and efficiency.
• 4" thick endwalls provide more
interior work space and clean-lined
uncluttered design.
Available Option: • Interior baffles designed to
Adjustable Baffles minimize turbulence and optimize
containment.
Air Flow and Static Pressure Alarms • Narrow framed upper sash with
Service Fittings and Piping four horizontal glass panels on two
tracks, frameless lower sash with
Electrical Fixtures and Wiring full-length formed steel handle for
UL listed when pre-wired per UL 61010A-1 neat, clean appearance and
streamline air features.
1805 UL classified with Kemglass, Stainless
Steel, or Phenolic Resin liner • Low profile PVC sash tracks and
exclusive sash leveling and
Vapor Proof and Explosion Proof Lighting alignment features assure easy-
Stainless Steel Deflector Vane smooth sash operation
Sash Frame • Large friction-fit interior access
panels provide easy access to
Tempered Sash Glass piping and service fittings.
Tissue Screen • Heavy gauge cold rolled steel
Fire Extinguisher exterior panels with independent
rigid structural frame.
Distillation Rack
• Designed and tested using
Sash Stop ASHRAE 110-1995, BS 7258, and
Stainless Steel Duct Collar DIN 12 924 standards.
Work Floor & Removable Work Shelf
SAFH-11/09-36
Supreme Air Fume Hood H32
Specifications:
Supreme Air Combination Sash Walk- of cold rolled steel, phosphate coated Combination Sash Walk-In Hoods are
In Fume Hoods are furnished with a with a baked chemical resistant, furnished with a Restricted By-Pass to
choice of liner and baffles with upper, synthetic resin finish. The exhaust match the restricted sash opening. They
center, and lower exhaust slots. Each duct collar is polyethylene, 1115/16" are designed for use with both constant
fume hood is complete with a counter O.D. (8 foot hoods are furnished with volume and VAV applications. An Open
balanced, narrow framed upper sash two duct collars.) By-Pass is available on request for
with horizontal panels, and a frameless applications where the hood is operated
lower sash of 1/4" combination safety with the sash fully open. Combination
glass and interior plumbing access Sash Walk-In Hoods are not designed
panels. Hood exteriors are fabricated for use with Auxiliary Air Chambers.
S = Type 304 Stainless Steel Accessories Include: Two 120 volt AC 20 amp GFI receptacles, single-tube,
T-5 fluorescent light fixture with bulb and 20 amp light switch. No wiring for
The blank left in the fume hood
the electrical fixtures is included unless H-Option is selected.
catalog numbers is for designating
the desired lining. Optional Accessories: Each front post and interior end liner is punched for
Example: H32T5448B00 would up to five (5) remote control service fittings. The right hand post is punched for
designate a 4' hood with a Phenolic a second electrical fixture at the top which may be used for a fan switch or
Resin lining. other electrical device. Service fittings, fan, fan switch, optional work floor,
and removable work shelf must be ordered separately.
Features:
• Radiused corner posts and airfoils
Available Option: for smooth air movement assures high
Adjustable Baffles level of comfort, safety and efficiency.
Air Flow and Static Pressure Alarms • 4" thick endwalls provide more
interior work space and clean-lined
Service Fittings and Piping uncluttered design.
Electrical Fixtures and Wiring • Interior baffles designed to
UL listed when pre-wired per UL 61010A-1 minimize turbulence and optimize
containment.
1805 UL classified with Kemglass, Stainless • Three panel framed sash, hung
Steel, or Phenolic Resin liner from full length triple track
Vapor Proof and Explosion Proof Lighting overhead carrier on nylon rollers for
smooth operation and easy access.
Stainless Steel Deflector Vane
• Large friction-fit interior access
Stainless Steel Sash Frame panels provide easy access to
Tempered Sash Glass piping and service fittings.
Tissue Screen • Heavy gauge cold rolled steel
exterior panels with independent
Fire Extinguisher rigid structural frame.
Distillation Rack • Designed and tested using
Sash Stop ASHRAE 110-1995, BS 7258, and
DIN 12 924 standards.
Stainless Steel Duct Collar
Work Floor & Removable Work Shelf
SAFH-11/09-38
Supreme Air Fume Hood H34
Specifications:
Supreme Air Horizontal Sash Walk-In on a triple track overhead carrier polyethylene exhaust duct collars,
Fume Hoods are furnished with a and interior plumbing access 1115/16" O.D.
choice of liner and baffles with panels. Hood exteriors are Supreme Air Horizontal Sash Walk-In
upper, center, and lower exhaust fabricated of cold rolled steel, Fume Hoods are available with a
slots. Each fume hood is complete phosphate coated with a baked Restricted By-Pass only. They may
with three panel framed sash of 1/4" chemical resistant, synthetic resin be used either with or without a
combination safety glass, hanging finish. They are furnished with two VAV system.
Consult your Kewaunee representative or the factory for other sash arrangements.
SAFH-11/09-39