2 Manfred Waidhas
2 Manfred Waidhas
2 Manfred Waidhas
2)
GWh
Flexible and
Storage o f excess Energy
Grid energy subsequent efficient power Topic of current develop-
to o ther three o ptions storage
generation ments, but technical and
economic limitations
4 3
* DMS = d emand side management
Key statements
§ There is no universal solution for
electrical storage
/ Methane
§ Large scale storage can only be
addressed by Pumped Hydro,
Compressed Air (CAES) and
chemical storage media like
hydrogen and methane
H2 via P2G is the only viable approach to store electrical energy >10 GWh
© Siemens AG 2 015 All rights reserved.
Page 4 PD LD HY
Hydrogen is multi-functional: shifts CO2-savings
in power generation to mobility and industry
• There is a huge industrial demand of hydrogen (≈ 100 billion USD)
today • Electrolyzers, splitting water into H2 and O2 are used in niches for
hydrogen production.
• However, they will be the enabler to store (volatile) electricity.
à New technical properties will be required
Objective:
• Develop an energy storage plant for the
decentralized use of grid bottlenecks in order
to provide grid services (control power )
• High efficiency, dynamic load changes
• Injection in local gas grid and multi-use
trailer-filling
• 6 MW Electrolyzer (3 Stack à 2 MW)
• Timeline: 03/2013 – 12/2016
Milestones:
• Groundbreaking ceremony May 2014
• Commissioning July 2015
Partners:
Project funded by BMWi
© Siemens AG 2 015 All rights reserved.
Page 8 PD LD HY
Energiepark Mainz
Elektrolyzer System
§ 3 SILYZER 200
PEM-electrolyzer skids
§ 1.25 MW rated power / 2.0 MW
peak power (limited in time)
§ High dynamic: load changes in
seconds, capable for partial load
in a wide range
§ 35 bar outlet pressure
9
SILYZER 200 / Electrolyser basic system
Solution for tomorrow
* depends o n o peration
purchased
electric power electricity price
purchased electric power
electricity price
Quelle: eigene Darstellung
12
Energiepark Mainz Demand in secondary control power ( 2nd CP)
and conceivable use of a PtG plant
Qualification for grid services positive 2nd CP negative 2nd CP
BETR. P OS BETR. NEG
SRL-Bedarf
Soll-Leistung
power slope Ist-Leistung
power profile 500 MW
0 MW
6 000 -500 MW
demand
-1 000 MW
5 000 -1 500 MW
0:00h 6:00h 12:00h 18:00h 24:00h
4 000
power [kW]
4 MW
PtG-Anlage
PtG plant
3 000
3 MW
2 000
2 MW
Einsatzof
operation
1 000
1 MW
-
13:00:00 13:15:00 13:30:00 13:45:00 14:00:00 0 MW
Tagesverlauf (14.01.2015)
intraday Jan 14, 2015
source: own measurements
13
Energiepark Mainz – Status
First results
H 2 production
H2 Produktion efficiency
Wirkungsgrad
(outlet electrolyzers)
600 60%
• Data obtained by
measurements in 400 40%
Oct 2015
200 20%
- 0%
- 1 000 2 000 3 000 4 000 5 000 6 000 7 000
Purchased power Energiepark Mainz [kW]
14
“Power to Gas” needs a common understanding
use of hydrogen as a valuable injection of hydrogen into the reaction of hydrogen with CO2
material natural gas grid to methane and subsequent
- directly as fuel - use as fuel
- chemical syntheses - injection into the NG grid
- process gas
The business cases of the individual P2G approaches differ notably.
© Siemens AG 2 015 All rights reserved.
Page 1 5 PD LD HY
Green (CO2-free) hydrogen:
a broad variety of potential applications
• Steel • Generator
production cooling
wind turbines