Nothing Special   »   [go: up one dir, main page]

Catalogo Pts 1000

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Automated Perimeter PTS 1000

PTS 1000 Technical Data


Examination bowl

300 mm radius, closed type, ventilated

Tested field range

100 (160 with fixation shift horizontally)

Perimetry technique

Static, kinetic

Stimulus size

Goldmann Sizes I-V

Stimulus colors

white, blue, red, green

Stimulus speed in
kinetic perimetry

2-10/s

Maximum Stimulus
intensity

10000 asb

Fixation method

control of blind spot position or digital detection of pupil position

Patient response time

adaptive to patient speed or set manually from 0,1 to 9,9s

Background
illumination

depends on stimuli type-31,5 asb for white and red stimuli, 10 asb for green,
314 asb yellow background for blue stimuli, set automatically

Maps

24 (24 with extent to 30nasally), 30 (central 30), Full (50 in every directions)
Central (30 in horizontal axis and 22 in vertical axis)
Glaucoma (30 with extent up to 50 in nasal direction)
Peripheral (from 30 to 50), Macula (up to 10)
Extended (special field for drivers examination 50 in nasal direction;
80 in temporal direction), Fast (up to 30 with scarce points)
Binocular Drivers Test (up to 80 in horizontal axis, up to 50 in vertical axis)
User (up to 50 user defined)

Strategies

Kinetic, Screening, Threshold, 3-zone, Fast threshold, BSV (Binocular Single Vision),
Flicker (Critical Fusion Frequency), Blue On Yellow (SWAP)
BDT (Binocular Drivers Test), Advanced
Reduced field option
Neurological defects option

Result maps

age norm deviation (total deviation), pattern deviation, hill of vision deviation
defect probability graph,defects progress analysis, ,results overview
Bebie curve, Pupil movement graph, 3D visualization of patients HOV.

OPTOPOL Technology S.A.

Interface

USB

Tel/Fax: +48 32 6709173


info@optopol.com.pl

Dimensions

693 x 585 x 444 HxWxD

Operating Voltage

100-250V 50-60Hz

Additional features

Eye monitoring by means of built-in video camera. Advanced auto-detection


of eye position. Automatic pupil diameter measurement. Automatically controlled
chin-rest enables to set proper patients position precisely and easily
Printout manager with predefined printout styles. Network capabilities (remote
database, networked review stations). Direct database back-up. Special ventilation
system is used to keep fresh air throughout examination inside stimulation bowl

ul. abia 42, 42-400 Zawiercie, POLAND

www.optopol.com

Local Distributor:

ver. PTS1000 03-2009

PTS 1000

Automated Perimeter
PTS 1000
is a modern diagnostic instrument
for precise and fast testing of field
of vision.

It offers static and kinetic stimuli with


all Goldmann stimuli sizes and all stimuli colors used in perimetry. Wide range
of strategies and analysis tools combined with intuitive interface give you
powerful diagnostic tool whose handling you will enjoy. Built-in maps and
possibility of creating own ones give a
chance to examine only these areas,
which are necessary. With PTS1000
examination doesn't have to be tiring
anymore.

FLICKERING TEST

The device also enables examination by means of flickering stimuli for CFF (Critical Fusion Frequency) measurement. CFF is used as an index of fatigue and it is
clinically applied to neuro-ophthalmologic disorders
derived from optic nerve disorder, especially for diagnosis and evaluation of glaucoma.

Depending on chosen test strategy, it enables defining


the sensitivity threshold of retina in a given area, as well
as making a fast screening test. Accurate threshold,
Intelligent advanced threshold, Screening and quick 3zone can be selected according to needs and patient's
condition.

FIELDS

PTS 1000 in standard offers all analysis tools required to


make a diagnosis. Age normative data and age norm deviation (total deviation) graph allow to quickly state condition of
the patient. Bebie curve points the size and character of
vision field defect while HoV and pattern deviation graphs
highlight its irregularity. Overview window can be used to display previous examinations for long term analysis.

24 24/30

COLOUR PERIMETRY

PTS 1000 offers white, blue, red and green stimuli on


white or yellow background. Except classic perimetry it
enables to use "blue on yellow" (SWAP) examination
method which utilizes fact of earlier loss of sensitivity to
color based stimuli than to white-on-white stimuli
based testing. Red color can additionally be used for
diagnosis of toxic vision losses.

STRATEGIES
Examination strategies:
Kinetic test
Screening
Threshold
3-zone
Fast threshold
BSV (Binocular Single Vision)
Flicker (Critical Fusion Frequency measurement)
BDT (Binocular Drivers' Test)
Advanced

BINOCULAR CAPABILITIES

STANDARD VISION TESTS

ANALYSIS TOOLS

Implemented BSV strategy allows examination of


diplopic areas. Testing of drivers is also possible thanks
to included extended field, which enables testing field
up to 80 degrees temporally and Binocular Drivers Test
with Esterman score.

30 30
central 30
full 50
peripheral 30 50
macula 10
glaucoma 22 / 50
extended nas. 50 / temp. 80
fast 30
user defined 50
BDT Binocular Drivers' Test
(80 horizontal, 50 vertical)

OVERVIEW MODULE

Overview module allows review of 5 different analysis graphs


(5 columns) of up to 8 examinations simultaneously. User can
freely select analysis tool and graph type. All this information
can be printed or saved as image file.

TIME SAVING
Advanced strategy which utilizes special algorithm
allows quicker examination without loss in result resolution. 30-2 field can be tested in less than 3 minutes.
Additionally 3 accuracy levels can be selected.
Reduced Field and Neurological Field Reduction
options help reduce examination time for other strategies.

PTS 1000 software has a new printout manager module. It


gives great degree of freedom in deciding what should be on
a printout and where it should be. Possibility to save own
layouts as well as access to predefined templates makes PTS
1000 software very powerful tool which is easy to handle even
by non experienced operator. Printouts may look and contain
information as Octopus' or Humphrey's depending on
doctor's custom.

RELIABILITY

PTS1000 is all you need for modern perimetry:


Goldmann kinetic and static perimetry
Threshold, Fast Threshold, Advanced, Screening,
3-zone
Flickering (CFF), Blue on Yellow (SWAP),
BSV for testing diplopia
Binocular Drivers Test (160) with Esterman
standard score
4 stimuli colors: white, blue, red, green
Advanced analysis tools for easy diagnosis
Advanced fixation control for high reliability

Examination reliability can be estimated on the basis of


false negative and false positive tests. Built-in digital
camera allows eye-detection during examination and
during setting patient's position. Thanks to pupil tracking system it allows a continuous automatic control of
fixation. When patient loses fixation, blind spot is examined and special attraction mechanism turned on. Well
known Heijl-Krakau method allows tracking of a blind
spot and monitoring of examination reliability. All reliability indices are presented in examination results and
on the printout.

KINETIC TEST

Thanks to kinetic strategy it is possible to examine


hardly cooperating patients with big defects for whom
static examination is difficult to perform. 4 stimuli
colors, I-V Goldmann sizes, adjustable stimuli velocity,
silent operation, built-in programs together with option
of retesting arbitrary vectors defined by user make
PTS1000 a top product for kinetic perimetry.

INTERFACE
Test result is presented as four easy-to-interpret graphic
charts which contents can be freely selected from available
analysis tools. Results can be presented in form of numerical
maps of sensitivity in dB, intuitive dot scale or color map for

faster identification of out-of-norm regions. New interface


allows easy follow up. It is possible to take a look into present
and past examinations of one patient on one screen.

PTS 1000

PRINTOUT

You might also like