Features - Extremely easy to install - User-friendly snap t cover - Case geometry allows easy cable lead-in - Cable strain relief integrated in PG11 - Combi-bracket for vertical or horizontal installation - High adjustment accuracy through individual scale laser-etching per switch - Long-term stability of switching points through trapezoidal bead diaphragm - Multi-layer gold plated contact
Pressure
Snap t cover
Humidity
The type 604 pressure switch is used as a p ow switch in ventilation ducts for the control of lters and fans, and in primary and secondary control systems for the control of air dampers. The 604 pressure monitoring switches are also ideally suited to protect heating coils from overheating and for monitoring industrial air cooling circuits.
SPECIFICATIONS
Medium Air and neutral gases Pressure range 0.2 50 mbar Tolerable overload on one side 75 mbar at -30 75 C 50 mbar at -30 85 C Setting ranges / Switching differential The switching differential is factory-set Contact system Changeover switch Service life Mechanical > 106 switching cycles Electrical connection/Protection standard Screw terminals or AMP connectors 6.3 mm or 4.8 mm according to DIN 46244 Cable gland PG11 with cable strain relief Protection connections Without cover IP 00 With cover IP 54 Pressure connections Pipe 6.2 mm Adapter inside thread G 1/8 Weight Without bracket approx. 93 g With combi-bracket type C approx. 144 g Mounting Several brackets Fastening clip for quick mounting Test / Admissions ETL CE conformity DVGW according to DIN 1854 EU conformity: Low voltage directive 73/23/EWG Gas appliance directive: 90/396/EWG CE 0085 A P0918 Packaging Please state on order Single packaging n cardboard Multiple packaging in cardboard (20, 100 or 320 pcs)
Air Flow
Repeatability Setting range between 0.2 3 mbar 0.025 mbar 0.5 5 mbar 0.05 mbar 1 10 mbar 0.05 mbar 5 20 mbar 0.05 mbar 10 50 mbar 0.15 mbar Switching load Multi-layer contact (suitable for DDC) Resistive load 5 A at 250 VAC 4 A at 30 VDC Inductive: (loads with 6-fold starting current cos _ 0.6) 0.8 A at 250 VAC 0.7 A at 30 VDC Material in contact with medium Case: PC 10% GF Cover: PC Diaphragm: Silicone LSR tempered 200 C, free of gas emissions Temperature Medium and ambient temperature -30+85C Storage -40 -+85C
Environment
EX Proof / IS
Portable Instruments
151
Temperature
Huba Control
Calibrator
Versions A - Snap t B - Electrical connections C - Individual scale engraving D - Switch with fastening clip
Pressure
COMPACT A/C SET (STANDARD) Consisting of switch with hose connection 6.2 mm, scale in mbar, screw terminals, multi-layer contact up to 5 A (suitable for DDC), combi-bracket type C and hose connection set, single packaging.
SETTING RANGE (MBAR) 0.2 ... 3 0.5 ... 5 1 5 10 ... 10 ... 20 ... 50
CONNECTION SET Fig.1 (Metal) Fig.1 (Metal) Fig.1 (Metal) Fig.1 (Metal) Fig.1 (Metal) Fig.2 (Plastic) Fig.2 (Plastic) Fig.2 (Plastic) Fig.2 (Plastic) Fig.2 (Plastic)
Humidity
ORDERING TABLE
Standard Version ETL execution, re classication VO Setting range mbar Pa InchH2O 0.2 ... 3 20 ... 300 0.08 ... 1.2 0.5 ... 5 50 ... 500 0.2 ... 2 1 ... 10 100 ... 1000 0.4 ... 4 5 ... 20 500 ... 2000 2 ... 8 10 ... 50 1000 ... 5000 4 ... 20 Scale Scale in mbar Scale in Pa Scale in inchH2O Without scale (rating plate in mbar) Without scale (rating plate in Pa) Without scale (rating plate in inchH2O) Pressure connections Pipe 6.2 mm without pressure orice Pipe 6.2 mm with pressure orice on P2 Inside thread G1/8 without pressure orice Inside thread G1/8 with pressure orice on P2 Electrical connection Screw terminals AMP connector 6.3 mm AMP connector 4.8 mm Cover / Bracket With cover combi-bracket type C With cover bracket type A With cover bracket type B With cover without bracket Without cover combi-bracket type C Without cover bracket type A Without cover bracket type B Without cover without bracket Connection kit Without With connection kit (metal), 90C angled including tube 2m long (Fig.1) 1) With connection kit (plastic), straight including tube 2m long (Fig.2) 1) Switching points Two factory set switching points (please specify on order) One factory set switching point high (please specify on order) One factory set switching point low (please specify on order) Accessories Connection kit for vent duct (metal), 90C angled Connection kit for vent duct (plastic), straight Bracket type A 1) Bracket type B 1) Combi-bracket type C 1) Special screws for fastening switches to bracket Fastening clip for bracket A, B, C or direct mounting including tube 2m long (Fig.1) 1) including tube 2m long (Fig.2) 1)
604. 9
9 E
X X X X X X X
0 1 2 4 5 0 1 2 3 4 5 0 1 2 3 0 1 2 0 1 2 3 5 6 7 8 0 1 2 W R U Order no. 104312 100064 100295 100098 100106 102976 100294 100293