Magnetic Level Gauge K-TEK Products: KM26S Standardized Configuration Guide
Magnetic Level Gauge K-TEK Products: KM26S Standardized Configuration Guide
Magnetic Level Gauge K-TEK Products: KM26S Standardized Configuration Guide
Features
Highly visible level indication with no process fluid in contact
with the glass
All construction in-house by code certified welders
Float designed and weighted for maximum accuracy with 75
grams minimum upward buoyant force
Transmitter and switch options which can be installed, adjusted and maintained with no process interruption
Safe for corrosive, flammable, toxic, high-temperature and
high-pressure applications
Available materials
Stainless steel304/304L, 316/316L, CS Flange
Process capabilities
Full vacuum to 600 lb flange rating
-320 to 1000F/ -196 to 538C
0.25 specific gravity
All liquid viscosities
Interfaces as Low as .03SG
Testing and documentation available upon request
KM26S.a.b.c.d.e.f.g.h.i.j
a
b
d1-dx
e
f
g1-gx
Indicator Type
S1P
Fluorescent Shuttle with Permanently Sealed Lexan Tube (250F/121C max)1,4,5
S1G Fluorescent Shuttle with Hermetically Sealed Glass Tube (350F/177C max)1,4,5
S2G High Temperature Shuttle with Hermetically Sealed Glass Tube (1000F/538C max)1,4,5
M1P Yellow/Black MBG with Permanently Sealed Lexan Tube (250F/121C max)2,4,5
M2P Red/White MBG with Permanently Sealed Lexan Tube (250F/121C max2,4,5
M1G Yellow/Black MBG with Hermetically Sealed Glass Tube (650F/343C max)3,4,5
M2G Red/White MBG with Hermetically Sealed Glass Tube (650F/343C max)3,4,5
X
None
Notes:
1. Not available when a single transmitter is used for total & interface level combined.
2. Add IH as an additional ordering code to include insulation pad behind the indicator to increase the temperature rating to 350F/177C.
j
Indicator Scale/Ruler
N
No indicator channel (must select N for Indicator Type)
A
SS channel; no scale
B
SS channel; SS scale marked in ft / inches with 1/2 divisions (from 0 to 50 ft. standard3)
C
SS channel; SS scale marked in meters/centimeters with 1 cm divisions1,3
D
SS channel; SS scale marked in running inches with 1/2 divisions2,3
E
SS channel; SS scale marked in running inches with 1/8 divisions2,3
F
SS channel; custom SS scale (%, gallons, liters, etc.); Provide details of custom scale separate from model
number.
H
SS channel; dual scale; Specify types separately from model number.
Notes:
1. Standard rulers begin with 0 cm but can be specified from 100 cm to 10 meters.
2. Standard rulers begin with 0 inches but can be specified from: 1/2 divisions: -48 to 216 OR 1/8 divisions:
-48 to 144
Additional
ordering codes
VV
Vent Valve (In stock only 1/2, 3/4, 1)
IV
Isolation Valve (In stock only 1/2, 3/4, 1)
DV
Drain Valve (In stock only 1/2, 3/4, 1)
Inside Services:
ASM Certificate of Compliance to ASME (requires MTRs & Hydrotest)
COC Certificate of Compliance (General)
CCC Calibration Certificate
CRN Canadian Registration Number (requires MTRs & Hydrotest)
COO Certificate of Origin
DFR
Drawings (For Record)
DWG Drawings (For Approval)
ABD Drawings (As Built)
FUT
Functional Test
CRV Float Curve (Total level only)
HYD Hydrotest
HDC Hydrotest (with chart recording)
ITP
Inspection & Test Plan, No third party inspection allowed; review only
MTR Material Test Reports (MTRs)
MDR MDR (Manufacturers Data Records)
NAC NACE Hardness Certificate (requires MTRs)
Table 1
Chamber/Connection Material
SS4
304 / 304L SS
SS6
316 / 316L SS
Carbon Steel 1
Notes:
1
Not available as a chamber option. When CST, LCS and DUP materials are chosen, all parts which are not welded directly to the side of the
chamber can be of those same material types.
Table 2
Code Options / Definitions
B0
Blind Flange with Float Stop Spring and Mating Slip-On Flange
B1
B0 with FNPT3
B2
B0 with Plug3
B3
B4
B5
B6
B7
B9S
B9W
B10
B3L
B4L
B5L
B0 with Flat Sock-o-let or Flat Weld-o-let and Nipple for Socket Welding (Flat)3
B6L
B0 with Flat Sock-o-let or Flat Weld-o-let and Nipple for Butt Welding (37.5 Bevel)3
B7L
B9SL
B0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and Slip-on Flange3
B9WL
B0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and Weld Neck Flange3
B4P
B4LP
C0
FNPT Coupling
C0P
C0 with plug
C0E
C0EP
C0L
C0C
C0CE
C1
C1C
C1CE
Socket Weld Coupling with Pipe Nipple connected via Extruded Outlet2
C0LC
FNPT Coupling with Pipe Nipple and Sock-o-let (Min. SCH 40 Chamber)
C1L
C1LC
Table 2
Code Options / Definitions
D0
Blind Flange with Float Stop Spring and a Mating Weld Neck Flange
D1
D0 with FNPT3
D2
D0 with Plug3
D3
D4
D5
D6
D7
D9S
D9W
D10
D3L
D4L
D0 with Thread-o-let3
D5L
D6L
D0 with Flat Sock-o-let or Flat Weld-o-let, and Nipple for Butt Welding (37.5 Bevel)3
D7L
D9L
D0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and Slip-on Flange3
D3C
D4C
D3LC
D0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and Socket Weld Coupling3
D4LC
D0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and FNPT Coupling3
D4P
D4LP
D4CP
D4LCP
D0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple, FNPT Coupling and Plug3
Table 2 (continued)
Weld Neck Flange with Float Stop Spring (Top/Bottom Code Option)1
FE
F0
F0E
F1
F1C
F2
F2C
Weld Neck Flange with Weld-o-let and Pipe Nipple (Min. SCH 40 Chamber)
Weld Neck Flange with Weld-o-let and Concentric Reducer (Min. SCH 40 Chamber)
Weld Neck Flange with Weld-o-let and Concentric Reducer and Pipe Nipple (Min. SCH 40 Chamber)
F3
F3E
Weld Neck Flange with Concentric Reducer connected to chamber via Extruded Outlet2
F3C
F3CE
Weld Neck Flange with Concentric Reducer and Pipe Nipple connected via Extruded Outlet2
F4
F4C
Weld Neck Flange with Butt Weld Tee and Pipe Nipple
F43
Weld Neck Flange with Butt Weld Tee and Concentric Reducer
F43C
Weld Neck Flange with Butt Weld Tee and Concentric Reducer and Pipe Nipple
F9
GE
G0
G1
Slip-On Flange with Weld-o-let and Pipe Nipple (Min. SCH 40 Chamber)3
G2
G3
G3E
Slip-On Flange with Concentric Reducer and Pipe Nipple Connected via Extruded Outlet2
G4
G43
Slip-On Flange with Butt Weld-o-let, Concentric Reducer and Pipe Nipple
N0E
Branch Nipple for Socket Weld (Flat) connected to chamber via Extruded Outlet2
N0
N2E
Branch Nipple for Butt Welding (37.5 Bevel) connected to chamber via Extruded Outlet2
N2
N3E
N3
N6
N0L
Weld-o-let with Nipple for Socket Weld (Flat) (Min. SCH 40 Chamber)
N2L
Weld-o-let with Nipple, for Butt Welding (37.5 Bevel) (Min. SCH 40 Chamber)
N3L
Table 2 (continued)
Code Options / Definitions
R9
Weld Neck Flange with Mating Weld Neck Flange, Concentric Reducer and weld Neck Flange
S0
Screwed Pipe Cap with Float Stop Spring (Min. SCH 40 Chamber)
S4
S4P
S7
SW
Socket Weld Flange with Float Stop Spring (Top/Bottom Code Option)1
SW0
Blind Flange with Float Stop Spring and Mating Socket Weld Flange
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW9
SW10
SW3L
SW4L
SW5L
SW0 with Flat Sock-o-let or Flat Weld-o-let and Nipple for Socket Welding (Flat)3
SW6L
SW0 with Flat Sock-o-let or Flat Weld-o-let and Nipple for Butt Welding (37.5 bevel)3
SW7L
SW0 with Flat Sock-o-let or Flat Weld-o-let and Nipple for Nipple, MNPT3
SW9L
SW0 with Flat Sock-o-let or Flat Weld-o-let and Nipple for Pipe Nipple and Socket Weld Flange3
SW3C
SW4C
SW3LC
SW0 with Flat Sock-o-let or Flat Weld-o-let and Nipple and Socket Weld Coupling3
SW4LC
SW0 with Flat Sock-o-let or Flat Weld-o-let and Nipple and FNPT Coupling3
SW4P
SW4LP
SW4CP
SW4LCP
SWS1
SWS
SWE
SWS3
SWS3E
Socket Weld Flange with Concentric Reducer and Pipe Nipple connected via Extruded Outlet
SWS4
Socket Weld Flange with Butt Weld Tee and Pipe Nipple
SWS2
Socket Weld Flange with Sock-o-let, Pipe Nipple, Concentric Reducer and Pipe Nipple
SWS43
Socket Weld Flange with Butt Weld Tee, Concentric Reducer and Pipe Nipple
Table 2 (continued)
Code Options / Definitions
T0
T3
T4
T5
T6
T7
T9S
T9SW
T9W
T3L
T4L
T4P
T4LP
T5L
T0 with Flat Sock-o-let or Flat Weld-o-let and Pipe Nipple, for Socket Welding (Flat)
T6L
T0 with Flat Sock-o-let or Flat Weld-o-let and Pipe Nipple, for Butt Welding (37.5 Bevel)
T7L
T9SL
T0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and Slip on Flange3
T9WL
T0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and Weld Neck Flange
T9SWL
T0 with Flat Sock-o-let or Flat Weld-o-let, Pipe Nipple and Socket Weld Flange
Table 2 (continued)
Code Options / Definitions
W0
W1
W0 with FNPT
W2
W0 with Plug
W3
W4
W5
W6
W7
W9S
W9W
W10
W3L
W4L
W5L
W0 with Flat Sock-o-let or Flat Weld-o-let and Pipe Nipple for Socket Welding (Flat)
W6L
W0 with Flat Sock-o-let or Flat Weld-o-let and Pipe Nipple for Butt Welding (37.5 Bevel)
W7L
W9SL
W0 with Flat Sock-o-let or Flat Weld-o-let and Pipe Nipple and Slip-on Flange
W9WL
W0 with Flat Sock-o-let or Flat Weld-o-let and Pipe Nipple and Weld Neck Flange
W9SWL
W0 with Flat Sock-o-let or Flat Weld-o-let and Pipe Nipple and Socket Weld Flange
W1E
Branch Nipple with Flat End Cap with FNPT, connected via Extruded Outlet2
W1S
Branch Nipple with Flat End Cap with FNPT, connected via Saddle Weld
No Connection
Notes:
1. When a flanged option (F, G, L, SW) is a process connection on either end of the chamber as shown in the configuration tables these
will be provided with a float stop bar (or disk) and spring to keep the float confined in the chamber.
2. Extruded outlet connections can be utilized as follows:
*Stainless Steel:
*Stainless Steel:
Chamber Schedule
10
40
Flange/Pipe Sizes
1, 1-1/2 & 2
1-1/2 & 2
COUPLING SIZES
3/4, 1, 1 1/4
1 1/4
B0
B1
B2
B3
B4
B5
B6
B7
B9S
B9W
B10
B3L
B4L
B5L
B6L
B7L
B9SL
B9WL
B3C
B4C
B3LC
B4LC
B4P
B4LP
B4CP
B4LCP
D0
D1
D2
D3
D4
D5
D6
D7
D9S
D9W
D10
D3L
D4L
D5L
D6L
D7L
D9L
D3C
D4C
D3LC
D4LC
D4P
D4LP
D4CP
D4LCP
F9
L1
L2
L39
L9
R9
S0
S4
S4P
S7
SW
SW0
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW9
SW10
SW3L
SW4L
SW5L
SW6L
SW7L
SW9L
SW3C
SW4C
SW3LC
SW4LC
SW4P
SW4LP
SW4CP
SW4LCP
T0
T3
T4
T5
T6
T7
T9W
T3L
T4L
T5L
T6L
T7L
T9WL
T3C
T4C
T3LC
T4LC
T4P
T4LP
T4CP
T4LCP
W0
W1
W2
W3
W4
W5
W6
W7
W9S
W9W
W10
W3L
W4L
W5L
W6L
W7L
W9WL
W3C
W4C
W3LC
W4LC
W4LP
W4CP
W4LCP
C0
C0E
C1
C0P
C0EP
C0L
C1L
C0C
C0CE
C1C
C1CE
C0LC
C1LC
FE
F0
F0E
F1
F1C
F2
F2C
F3
F3E
F3C
F3CE
F4
F4C
F43
F43C
GE
G0
G1
G2
G3
G3E
G4
G43
LE
L0
L4
LCE
L43
LC
L3E
L3
L3EC
L3C
N0E
N0
N2E
N2
N3E
N3
N6
N0L
N2L
N3L
SWS1
SWSE
SWS3
SWS3E
SWS4
W1E
W1S
B0
B1
B2
B3
B4
B5
B6
B7
B9S
B9W
B10
B3L
B4L
B5L
B6L
B7L
B9SL
B9WL
B3C
B4C
B3LC
B4LC
B4P
B4LP
B4CP
B4LCP
D0
D1
D2
D3
D4
D5
D6
D7
D9S
D9W
D10
D3L
D4L
D5L
D6L
D7L
D9L
D3C
D4C
D3LC
D4LC
D4P
D4LP
D4CP
D4LCP
F9
L1
L2
L39
L9
R9
S0
S4
S4P
S7
SW
SW0
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW9
SW10
SW3L
SW4L
SW5L
SW6L
SW7L
SW9L
SW3C
SW4C
SW3LC
SW4LC
SW4P
SW4LP
SW4CP
SW4LCP
T0
T3
T4
T5
T6
T7
T9W
T3L
T4L
T5L
T6L
T7L
T9WL
T3C
T4C
T3LC
T4LC
T4P
T4LP
T4CP
T4LCP
W0
W1
W2
W3
W4
W5
W6
W7
W9S
W9W
W10
W3L
W4L
W5L
W6L
W7L
W9WL
W3C
W4C
W3LC
W4LC
W4LP
W4CP
W4LCP
Table 3
Flanged Connections
Slip on Flanges:
Socket Weld
Flanges:
Raised Face
Raised Face
Raised Face
150#
300#
600#
SR51
SR53
SR56
SWR51
SWR53
SWR56
WR51
WR53
WR56
150#
300#
600#
SR71
SR73
SR76
SWR71
SWR73
SWR76
WR71
WR73
WR76
150#
300#
600#
SR11
SR13
SR16
SWR11
SWR13
SWR16
WR11
WR13
WR16
150#
300#
600#
SR151
SR153
SR156
SWR151
SWR153
SWR156
WR151
WR153
WR156
150#
300#
600#
SR21
SR23
SR26
SWR21
SWR23
SWR26
WR21
WR23
WR26
150#
300#
600#
SR251
SR253
SR256
SWR251
SWR253
SWR256
WR251
WR253
WR256
150#
300#
600#
SR31
SR33
SR36
SWR31
SWR33
SWR36
WR31
WR33
WR36
Pressure Rating
Size
1/2
3/4
1-1/2
2-1/2
Table 3 (continued)
Slip on Flanges:
Socket Weld
Flanges:
Raised Face
Raised Face
Raised Face
SR41
SR43
SR46
N/A
N/A
N/A
WR41
WR43
WR46
Pressure Rating
Size
150#
300#
600#
NOTES:
1. Extruded Outlets are full bore up to a maximum of 2 See Note 2, Table 2 on page 11.
2. Flat face flanges can be supplied in lieu of raised face. Replace "R" notation with "F". (i.e. For a 150# flat face slip-on. . . SF51)
3. The items marked "N/A" are not availabe per ASME B16.5.
Weld-o-lets:
Size
Rating
Sock-o-lets:
Thread-o-lets:
Designation
Size
Rating
Designation
Size
Rating
Designation
1/2
3/4
1
1-1/2
2
SCH
SCH
SCH
SCH
SCH
40
40
40
40
40
W054
W075
W104
W154
W204
1/2
3/4
1
1-1/2
2
3000#
3000#
3000#
3000#
3000#
S053
S073
S103
S153
S203
1/2
3/4
1
1-1/2
2
3000#
3000#
3000#
3000#
3000#
T053
T073
T103
T153
T203
1/2
3/4
1
1-1/2
2
SCH
SCH
SCH
SCH
SCH
80
80
80
80
80
W058
W078
W108
W158
W208
1/2
3/4
1
1-1/2
2
6000#
6000#
6000#
6000#
6000#
S056
S076
S106
S156
S206
1/2
3/4
1
1-1/2
2
6000#
6000#
6000#
6000#
6000#
T056
T076
T106
T156
T206
1/2
3/4
1
1-1/2
2
SCH
SCH
SCH
SCH
SCH
160
160
160
160
160
W051
W071
W101
W151
W201
Pipe Nipples:
Size
Rating
Plugs:
Threaded Couplings:
Designation
Size
Rating
Designation
Size
Rating
Designation
Size
Rating
Designation
1/2
3/4
1
1-1/2
2
SCH
SCH
SCH
SCH
SCH
40
40
40
40
40
N054
N074
N104
N154
N204
1/2
3/4
1
1-1/2
2
3000#
3000#
3000#
3000#
3000#
P053
P073
P103
P153
P203
1/2
3/4
1
1-1/2
2
3000#
3000#
3000#
3000#
3000#
C053
C073
C103
C153
C203
1/2
3/4
1
1-1/2
2
3000#
3000#
3000#
3000#
3000#
SC053
SC073
SC103
SC153
SC203
1/2
3/4
1
1-1/2
2
SCH
SCH
SCH
SCH
SCH
80
80
80
80
80
N058
N078
N108
N158
N208
1/2
3/4
1
1-1/2
2
6000#
6000#
6000#
6000#
6000#
P056
P076
P106
P156
P206
1/2
3/4
1
1-1/2
2
6000#
6000#
6000#
6000#
6000#
C056
C076
C106
C156
C206
1/2
3/4
1
1-1/2
2
6000#
6000#
6000#
6000#
6000#
SC056
SC076
SC106
SC156
SC206
1/2
3/4
1
1-1/2
2
SCH
SCH
SCH
SCH
SCH
160
160
160
160
160
N051
N071
N101
N151
N201
FN05
FN07
FN10
FN15
FN20
SW05
SW07
SW10
SW15
SW20
Sample Accessories
KM26 with AT200 & MS41
Top Process (from Side) and Bottom Process (from bottom) of KM26 (Center to Face)
Sample Model #:
KM26S.SS6.SS6.WO.FE.X.G.WR21.SR21.S1G.B-IH1.TT1
Note: The required CF and/or ML dimensions shall be specified by the customer.
CF
C-F
FC
Top Process and Bottom Process (from top and bottom) of KM26 (Face to Face)
Sample Model #:
KM26S.SS6.CST.G.X.X.G.SR21.SR21.S1P.C
Note: The required FF and/or ML dimensions (in addition to the desired A and
B dimensions) shall be specified by the customer.
FF
Top and Bottom Process Connection (from side) of KM26 (Center to Center)
Samplel Model #:
KM26S.SS4.SS4.W0.FE.FE.B0.WR23.WR23.S2G.D
CC & ML
Top Process (from top) and Bottom Process (from bottom side) of KM26 (Face to
Center)
Sample Model #:
KM26S.SS6.CST.G.X.GE.B2.SR21.SR21.P073.S2G.B
Note: The required FC and/or ML dimensions shall be specified by the customer.
FC
CC & ML
Factory Contact:
Seller Information
Name:
Phone:
Email:
Company or LBU:
Main Phone:
Fax:
Name:
Phone:
Email:
Company or LBU:
Country of Final Destination:
Note: This information will be required before accepting an order.
* All fields required
Tag ID#:
Process Conditions
Application for (select one): Total Level - Interface Level - Total & Interface
Upper Fluid Operating Sp. Gravity:
Minimum Specific Gravity:
Lower Fluid Second Sp. Gravity:
Fluid(s):
If water, steam service? Yes - No
Operating Temp:
Operating Pressure:
Minimum Ambient Temperature:
High Vibration Environment (Compressor Etc.)?
Max Temp:
Max Pressure:
Min. Temp:
Yes - No
Process Connection
Type:
Chamber Material:
Size:
Float Material:
Rating:
Flange Material:
Center to Center/ Measuring Length:
Vent/Drain Type & Size:
Indicator Details
Select: ___Shuttle or
___Bar Graph (choose color combination) Yellow/Black - Red/White
Scale (select one): Feet/In - Running In. (1/2 Div.) - Running In. (1/8/) - Meter/cm - Custom
Special Requirements:
__3:00
__6:00
__9:00
AT Transmitter:
__3:00
__6:00
__9:00
Switches:
__3:00
__6:00
__9:00
9:00
3:00
6:00
Note: Overall length will always be greater than measuring length (ML). Please specify if a max overall length is required.
ABB Inc.
18321 Swamp Road
Prairieville, LA 70769 USA
Phone: +1 225 673 6100
Service: +1 225 677 5836
Fax: +1 225 673 2525
E-mail: quotes.ktek@us.abb.com
Service e-mail: ktek-service@us.abb.com
ABB Engineering (Shanghai) Ltd.
No. 5, Lane 369, Chuangye Road
Kangqiao Town, Pudong District
Shanghai, 201319, P.R. China
Phone: +86 10 64231407
Service: +86 21 61056421
Fax: +86 10 64371913
E-mail: shan.li@cn.abb.com
Service e-mail: rola.li@cn.abb.com
ABB Limited
Salterbeck Trading Estate
Workington, Cumbria, England CA14 5DS
Phone: +44 7885333752
Service: +44 145 3826661
E-mail: enquiries.mp.uk@gb.abb.com
Service e-mail: abb.service@gb.abb.com
www.abb.com/level
Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or
possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents - in whole or in parts is
forbidden without prior written consent of ABB.
Copyright 2014 ABB
All rights reserved
Sales
Service
Contact us