Nothing Special   »   [go: up one dir, main page]

AWS D1.8 Certificate-Primacore LW71

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

The Shanghai Lincoln Electric Co., Ltd.

No. 195, Lane 5008, Hu Tai Rd.


Baoshan, Shanghai, 201907, P. R. China

Product: PRIMACORE LW-71


Classification: E71T-1C, E71T-9C
(EN ISO 17632-A-T 42 2 P C1 according to EN10204)
Specification: AWS D1.8/D1.8M:2013
Lot Number: E186089600
Date Issued: 2018/6/25

This is to certify that the above listed product was manufactured to meet the class T4 requirement of AWS A5.01 as required by clause 6.3.8.1 of AWS
D1.8/D1.8M.

The product stated herein was manufactured and supplied in accordance with the Quality System Program of The Shanghai Lincoln Electric Co.,Ltd,
Shanghai, China as outlined in our Quality Assurance manual. The Quality System Program of The Shanghai Lincoln Electric Co.,Ltd. has been accepted
by ABS and certified to ISO 9001:2015 by Certificate No.34753 with an expiration date of May 29.2020.

Test Conditions AWS D1.8 Requirements High Heat Input Low Heat Input
Results Results
Electrode Size (mm) 1.2 1.2
Electrode Polarity DC+ DC+
Wire Feed Speed inch/min 300 170
Current (amps) 280 190
Arc Voltage (volts) 28 22
Contact Tip to Work Distance (mm) 25 20
Passes/Layers 9/5 16/7
Preheat Temp. ℃ 120 35
Interpass Temp. ℃ 240 120
Shielding Gas (Per AWS A5.32) 100%CO2 (SG-C) 100%CO2 (SG-C)
Heat input KJ/mm avg. 3.2 1.2
Welding Position 1G 1G

Mechanical Properties
Tensile Strength (MPa) 480 min. 575 615
Yield Strength (MPa) 400 min. 480 550
Elongation (%) 22% min. 28.5 26.5
Avg.Charpy V-notch Impact Properties 146 157
Joules @ 20℃ 54 min. 143, 147, 147 156, 157, 157

REMARK:
WE HEREBY CERTIFY THAT THIS REPORT IS CORRECT AND THAT ALL TEST RESULTS ARE IN COMPLIANCE WITH THE SPECIFICATION
DESCRIBED HEREIN.AND THE CERTIFICATE COMPLIES TO THE REQUIREMENTS OF EN10204, Type 2.2 ALSO.

This product satisfies the requirements of AWS D1.8/D1.8M, Annex E after exposure for two weeks at 27℃, 80% relative humidity.

Strength values in SI units are reported to the nearest 10 MPa converted from actual data, Preheat and interpass temperature values in SI units are
reported to the nearest 5 degrees.

The strength and elongation properties were obtained from 12.5mm (0.5 in.), A4 tensile specimen artificially aged at 105℃ for 48 hours, as permitted by
AWS A5.20. A naturally aged tensile specimen may take months to achieve the specified properties. See AWS A5.20, paragraph A8.3. The time required
for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure of the weld deposit and other
factors.

D.S.Park Technical Director Joe Yang Managing Director

The Shanghai Lincoln Electric Co.,Ltd. Page 1 of 1 SLEC-QAF-015 Rev. B