Iec 60335-2-40
Iec 60335-2-40
Iec 60335-2-40
TEST REPORT
IEC 60335-2-40
Safety of household and similar electrical appliances
Part 2-40: Particular requirements for electrical heat pumps, air
conditioners and dehumidifiers
Report Number. .............................. : 180423126GZU-001
Date of issue ................................... : September 28, 2018; Modification 12: November 10, 2020
Total number of pages ................... : 177
Applicant’s name ............................ : Gree Electric Appliances, Inc. of Zhuhai
Address ........................................... : West Jinji Road, Qianshan, Zhuhai, Guangdong 519070, P.R.
China
Test specification:
Standard .......................................... : IEC 60335-2-40:2002 (Fourth Edition) + A1:2005 (incl. Corr.1:2006)
+ A2:2005 in conjunction with
IEC 60335-1:2010 (Fifth Edition)
Test procedure ............................... :
Non-standard test method………..: N/A
Test Report Form No...................... : IEC60335_2_40J
Test Report Form(s) Originator .... : VDE
Master TRF ...................................... : Dated 2014-06
Copyright © 2014 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
Test item description ..................... : Air conditioner, portable (Local air conditioner)
Trade Mark ...................................... : GREE
Manufacturer ................................... : Gree Electric Appliances, Inc. of Zhuhai
Model/Type reference .................... : GPC12AL-K5NNA3A, GPH12AL-K5NNA3A, GPH12AL-K5NNA2A,
GPC12AL-K5NNA3B, GPH12AL-K5NNA2B, GPC12AL-K5NNA2A,
GPC12AL-K5NNA3C, GPH12AL-K5NNA3C, GPH12AL-K5NNA1C,
GPH12AL-K5NNA1A, GPC12AL-K5NNA1C, GPC12AL-K5NNA2C;
GPH12AL-K5NNA2C, GPC12AL-K5NNA3D
Ratings ............................................ : 220-240V~, 50Hz, Class I, R290,
1500W for GPC12AL-K5NNA3C, GPC12AL-K5NNA1C, GPC12AL-
K5NNA2C, GPC12AL-K5NNA3D
1550W for other models
German:
Warning mark:
Note:
1. the value for “X”, refer to user manual.
2. The symbol “Caution: risk of fire” including colour and format shall be permanently placed on the
appliance and the perpendicular height of the triangle shall be at least 30mm.
3. The symbol “Caution: risk of fire” shall be placed on the nameplate of the appliance, and perpendicular
height of the symbol shall be at least 10mm without the need of be in colour.
4. The symbols of “read operator’s manual”, “operator’s manual, and “service indicator shall be placed on
the appliance, and their perpendicular heights shall be at least 10mm.
Note:
1. When placing these electrical equipments on the market, the importer and manufacturer should indicate
on the electrical equipments his name, registered trade name or registered trade mark and the postal
address at which he can be contacted.
2. When placing these electric equipments on the market, Type, batch, or series number that allows their
identifications will be pasted on the appliance.
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Modification 1:
This test report replaces the original test report 180423126GZU-001 dated on September 28, 2018. It is
issued because of following additions and/or changes:
1. Adding one new model GPH12AL-K5NNA2A which is identical with original model GPH12AL-
K5NNA3A except front panel. See photo document for details.
2. Adding one alternative front panel for models GPH12AL-K5NNA3A, GPC12AL-K5NNA3A. See
photo document for details.
3. Adding alternative plug for all models. See table 24.1 for details.
Modification 2:
This test report replaces the original test report 180423126GZU-001 with modification 1, dated on January
07, 2019. It is issued because of following additions and/or changes:
1. Adding two new models GPC12AL-K5NNA3B and GPH12AL-K5NNA2B which are separately
identical with original models GPC12AL-K5NNA3A and GPH12AL-K5NNA3A except main board
and new models have WIFI function. See photos document for details.
2. Adding one new model GPC12AL-K5NNA2A which is identical with original model GPC12AL-
K5NNA3A except front panel. See photo document for details.
3. Adding alternative x capacitor and rectifier for all models. See table 24.1 for details.
Modification 3:
This test report bases on the test report 180423126GZU-001 with modification 2, dated on March 06, 2019.
It is issued because of following additions and/or changes:
1. Adding main board (M701F1PJ) which is identical with main board (M701F1NJ) except main board
(M701F1PJ) has deleted WIFI function for model GPC12AL-K5NNA3B, GPC12AL-K5NNA3A,
GPC12AL-K5NNA2A. See table 24.1 for details.
2. Adding main board which (M701F2SJ) is identical with main board (M701F2TJ) except main board
(M701F2SJ) has deleted WIFI function for model GPH12AL-K5NNA2B, GPH12AL-K5NNA3A,
GPH12AL-K5NNA2A. See table 24.1 for details.
Modification 5:
This test report replaces the test report 180423126GZU-001 with modification 2, dated on March 06, 2019,
modification 3, dated on April 08, 2019, modification 4, dated on July 01, 2019. It is issued because of
adding one new model GPC12AL-K5NNA3C which is identical with model GPC12AL-K5NNA3B except
model name, rated power and refrigerant charge. See marking plate for details.
TRF No. IEC60335_2_40J
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou,
Guangdong, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Report No.: 180423126GZU-001
Page 13 of 177 Modification 12: November 10, 2020
Modification 6:
This test report replaces the test report 180423126GZU-001 with modification 5, dated on August 21, 2019.
It is issued because of following addition:
1. Adding one new model GPH12AL-K5NNA3C which is identical with model GPH12AL-K5NNA2B
except model name, weight, refrigerant charge, condenser and evaporator. See marking plate and
photos document for details.
2. Adding one new model GPH12AL-K5NNA1C which is identical with model GPH12AL-K5NNA3C
except front panel. See photos document for details.
Modification 7:
This test report replaces the test report 180423126GZU-001 with modification 6, dated on September 20,
2019. It is issued because of following addition:
1. Adding one new model GPH12AL-K5NNA1A which is identical with model GPH12AL-K5NNA3A
except front panel. See photos document for details.
2. Adding alternative front panel for model GPH12AL-K5NNA1C. See photos document for details.
3. Adding alternative 4-way valve for all models which have heating mode. See table 24.1 for details.
Modification 8:
This test report replaces the test report 180423126GZU-001 with modification 7, dated on November 22,
2019. It is issued because of following addition:
1. Adding one new model GPC12AL-K5NNA1C which is identical with model GPC12AL-K5NNA3C
except front panel. See photos document for details.
2. Adding one new factory as below:
Name: GREE ELECTRIC APPLIANCES (WUHU) CO., LTD.
Address: North of Lianhe Road, West of Wuhua Road, East of Yapeng Road, Economic Development
District of Sanshan, Wuhu City, 241000, AN’HUI, P. R. China
3. Adding alternative X2 capacitor. See table 24.1 for details.
Modification 9:
This test report replaces the test report 180423126GZU-001 with modification 8, dated on January 02,
2020. It is issued because of following addition:
1. Adding a new model GPC12AL-K5NNA2C which is the same as GPC12AL-K5NNA3C except the front
panel.
2. Adding a new model GPH12AL-K5NNA2C which is the same as GPH12AL-K5NNA3C except the front
panel.
3. Adding some alternative Y capacitor and high frequency transformer for all model, details refer to table
24,1.
Modification 11:
This test report replaces the test report 180423126GZU-001 modification 9 dated on April 3, 2020 and test
report 180423126GZU-001 modification 10 dated on June 17, 2020. It is issued because of the following
additions and changes:
1. Updating the standards from “EN 60335-1:2012+A11:2014+A13:2017” to “EN 60335-1:2012+A11:2014
+A13:2017+A1::2019+A14:2019+A2:2019”.
2. Adding alternative main board (M701F2ASJ), main board (M701F2BKJ), main board (M701F1BLJ) and
main board (M701F1BKJ) which have the same circuit diagram as main board (M701F2TJ), main board
(M701F2SJ), main board (M701F1NJ) and main board (M701F1PJ) respectively except for PCB layout.
See photos of documents for details.
3. Adding alternative control board, see photos documents for details.
4. Adding alternative high frequency transformer for all models. See table 24.1 for details.
Modification 12:
This test report replaces the test report 180423126GZU-001 modification 11 dated on July 20, 2020. It is
issued because of the following additions and changes:
1. Adding a new model GPC12AL-K5NNA3D which is the same as GPC12AL-K5NNA3C except for no
WIFI module in GPC12AL-K5NNA3D and the mass of refrigerant charge.
2. Adding alternative relay (HF160F/12-H5), fan motor (YD28X-L Tongde) and high frequency transformer
(ECO20-07PA XIN YUAN) for all model. See table 24.1 for details.
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
For water valves containing live parts and that are N/A
incorporated in external hoses for connection of an
appliance to the water mains, the degree of
protection declared for subclause 6.5.2 of
IEC 60730-2-8 is IPX7
24.1.5 Appliance couplers complying with IEC 60320-1 N/A
However, for appliances classified higher than N/A
IPX0, the appliance couplers complying with
IEC 60320-2-3
Interconnection couplers complying with N/A
IEC 60320-2-2
24.1.6 Small lamp holders similar to E10 lampholders N/A
complying with IEC 60238, the requirements for
E10 lampholders being applicable
24.1.7 For remote operation of the appliance via a N/A
telecommunication network, the relevant standard
for the telecommunication interface circuitry in the
appliance is IEC 62151
24.1.8 The relevant standard for thermal links is N/A
IEC 60691
Thermal links not complying with IEC 60691 are N/A
considered to be an intentionally weak part for the
purposes of clause 19
24.1.9 Contactors and relays, other than motor starting P
relays, tested as part of the appliance
They are also tested in accordance with clause 17 P
of IEC 60730-1, the number of cycles of operations
in 24.1.4 selected according to the contactor or
relay function in the appliance .............................. :
24.2 Appliances not fitted with: ----
- switches or automatic controls in flexible cords P
- devices causing the protective device in the fixed P
wiring to operate in the event of a fault in the
appliance
- thermal cut-outs that can be reset by soldering, P
unless
the solder has a melding point of at least 230 °C N/A
24.3 Switches intended for all-pole disconnection of N/A
stationary appliances are directly connected to the
supply terminals and have a contact separation in
all poles, providing full disconnection under
overvoltage category III conditions
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
25.1 Appliance not intended for permanent connection to fixed wiring, means for ----
connection to the supply:
- supply cord fitted with a plug, P
- an appliance inlet having at least the same degree N/A
of protection against moisture as required for the
appliance, or
- pins for insertion into socket-outlets N/A
Supply cord fitted with plug provided, if (IEC 60335-2-40): ----
- appliance only for indoor use (IEC 60335-2-40), P
- marked with rating of 25 A or less and P
(IEC 60335-2-40)
- complies with code requirements of country where N/A
it will be used (IEC 60335-2-40).
Appliance inlet not allowed (IEC 60335-2-40) N/A
25.2 Appliance not provided with more than one means P
of connection to the supply mains
Stationary appliance for multiple supply may be N/A
provided with more than one means of connection,
provided electric strength test of 1250 V for 1 min
between each means of connection causes no
breakdown
25.3 Appliance intended to be permanently connected to fixed wiring provided with one ----
of the following means for connection to the supply mains:
- a set of terminals allowing the connection of a N/A
flexible cord
- a fitted supply cord N/A
- a set of supply leads accommodated in a suitable N/A
compartment
- a set of terminals for the connection of cables of N/A
fixed wiring, cross-sectional areas specified in 26.6,
and the appliance allows the connection of the
supply conductors after the appliance has been
fixed to its support
- a set of terminals and cable entries, conduit N/A
entries, knock-outs or glands, allowing connection
of appropriate types of cable or conduit, and the
appliance allows the connection of the supply
conductors after the appliance has been fixed to its
support
For a fixed appliance constructed so that parts can N/A
be removed to facilitate easy installation, this
requirement is met if it is possible to connect the
fixed wiring without difficulty after a part of the
appliance has been fixed to its support
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
29.2 Creepage distances not less than those appropriate (see appended table) P
for the working voltage, taking into account the
material group and the pollution degree ............... :
Pollution degree 2 applies, unless Main power box P
- precautions taken to protect the insulation; N/A
pollution degree 1
- insulation subjected to conductive pollution; Parts in airflow P
pollution degree 3
A force of 2 N is applied to bare conductors, other P
than heating elements
A force of 30 N is applied to accessible surfaces P
In a double insulation system, the working voltage N/A
for both the basic and supplementary insulation is
taken as the working voltage across the complete
double insulation system
Insulation located in airflow, pollution degree 3 P
unless (IEC 60335-2-40)
insulation enclosed or located so that unlikely to be N/A
exposed to pollution due to normal use
(IEC 60335-2-40)
29.2.1 Creepage distances of basic insulation not less (see appended table) P
than specified in table 17 ...................................... :
However, if the working voltage is periodic and has N/A
a frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of
IEC 60664-4, these values being used if exceeding
the values in table 17 ............................................ :
Except for pollution degree 1, corresponding N/A
creepage distance not less than the minimum
specified for the clearance in table 16, if the
clearance has been checked according to the test
of clause 14........................................................... :
29.2.2 Creepage distances of supplementary insulation at (see appended table) P
least those specified for basic insulation in table 17,
or ........................................................................... :
Table 2 of IEC 60664-4, as applicable ................. : N/A
29.2.3 Creepage distances of reinforced insulation at least (see appended table) P
double those specified for basic insulation in table
17, or ..................................................................... :
Table 2 of IEC 60664-4, as applicable ................. : N/A
29.2.4 Creepage distances of functional insulation not less (see appended table) P
than specified in table 18 ...................................... :
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
Capacitors likely to be permanently subjected to the supply voltage, and used for ----
radio interference suppression or voltage dividing, comply with the following clauses
of IEC 60384-14, with the following modifications:
1.5 Terms and definitions ----
1.5.3 Class X capacitors tested according to subclass X2 N/A
1.5.4 This subclause is applicable N/A
1.6 Marking ----
Items a) and b) are applicable N/A
3.4 Approval testing ----
3.4.3.2 Table 3 is applicable as described N/A
4.1 Visual examination and check of dimensions ----
This subclause is applicable N/A
4.2 Electrical tests ----
4.2.1 This subclause is applicable N/A
4.2.5 This subclause is applicable N/A
4.2.5.2 Only table 11 is applicable N/A
Values for test A apply N/A
However, for capacitors in heating appliances the N/A
values for test B or C apply
4.12 Damp heat, steady state ----
This subclause is applicable N/A
Only insulation resistance and voltage proof are N/A
checked
4.13 Impulse voltage ----
This subclause is applicable N/A
4.14 Endurance ----
Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7 are N/A
applicable
4.14.7 Only insulation resistance and voltage proof are N/A
checked
No visible damage N/A
4.17 Passive flammability test ----
This subclause is applicable N/A
4.18 Active flammability test ----
This subclause is applicable N/A
G ANNEX G (NORMATIVE) ----
SAFETY ISOLATING TRANSFORMERS
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
The following modifications to this standard are applicable for safety isolating ----
transformers:
7 Marking and instructions ----
7.1 Transformers for specific use marked with: ----
- name, trademark or identification mark of the N/A
manufacturer or responsible vendor ..................... :
- model or type reference ...................................... : N/A
17 Overload protection of transformers and associated circuits ----
Fail-safe transformers comply with subclause 15.5 N/A
of IEC 61558-1
22 Construction ----
Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 are N/A
applicable
29 Clearances, creepage distances and solid insulation ----
29.1, 29.2, The distances specified in items 2a, 2c and 3 in N/A
29.3 table 13 of IEC 61558-1 apply
For insulated winding wires complying with N/A
subclause 19.12.3 of IEC 61558-1 there are no
requirements for clearances or creepage distances
For windings providing reinforced insulation, the N/A
distance specified in item 2c of table 13 of
IEC 61558-1 is not assessed
For safety isolating transformers subjected to N/A
periodic voltages with a frequency exceeding
30 kHz, the clearances, creepage distances and
solid insulation values specified in IEC 60664-4 are
applicable, if greater than the values specified in
items 2a, 2c and 3 in table 13 of IEC 61558-1
H ANNEX H (NORMATIVE) ----
SWITCHES
Switches comply with the following clauses of IEC 61058-1, as modified below: ----
The tests of IEC 61058-1 carried out under the N/A
conditions occurring in the appliance
Before being tested, switches are operated 20 N/A
times without load
8 Marking and documentation ----
Switches are not required to be marked N/A
However, a switch that can be tested separately N/A
from the appliance marked with the manufacturer’s
name or trade mark and the type reference
13 Mechanism ----
The tests may be carried out on a separate sample N/A
TRF No. IEC60335_2_40J
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou,
Guangdong, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Report No.: 180423126GZU-001
Page 71 of 177 Modification 12: November 10, 2020
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
Modifications applicable for class 0 and 01 appliances having a rated voltage ----
exceeding 150 V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE
Modifications may also be applied to class 1 appliances having a rated voltage ----
exceeding 150 V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE, if liable to be connected to a supply mains that
excludes the protective earthing conductor
5.7 The ambient temperature for the tests of clauses 11 N/A
and 13 is 40 +3/0 °C
7.1 The appliance marked with the letters WDaE N/A
7.12 The instructions state that the appliance is to be N/A
supplied through a residual current device (RCD)
having a rated residual operating current not
exceeding 30 mA
The instructions state that the appliance is N/A
considered to be suitable for use in countries
having a warm damp equable climate, but may also
be used in other countries
11.8 The values of Table 3 are reduced by 15 K N/A
13.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA
15.3 The value of t is 37 °C N/A
16.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA (mA):
19.13 The leakage current test of 16.2 is applied in N/A
addition to the electric strength test of 16.3
Q ANNEX Q (INFORMATIVE) ----
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits P
R ANNEX R (NORMATIVE) ----
SOFTWARE EVALUATION
Programmable electronic circuits requiring software N/A
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 validated in
accordance with the requirements of this annex
R.1 Programmable electronic circuits using software ----
Programmable electronic circuits requiring software N/A
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 constructed
so that the software does not impair compliance
with the requirements of this standard
R.2 Requirements for the architecture ----
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
NOTE A Stuck-at fault model denotes a fault model representing an open circuit or a non-varying signal
level. A DC fault model denotes a stuck-at fault model incorporating short circuit between signal lines.
a) For fault/error assessment, some components are divided into their sub-functions.
b) For each sub-function in the table, the Table R.2 measure will cover the software fault/error.
c) Where more than one measure is given for a sub-function, these are alternatives.
d) To be divided as necessary by the manufacturer into sub-functions.
e) Table R.1 is applied according to the requirements of R.1 to R.2.2.9 inclusive.
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
— — — — — —
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 ⎯ ⎯ N/A
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 ⎯ ⎯ N/A
1000 and 1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0 ⎯ ⎯ N/A
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 ⎯ ⎯ N/A
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 ⎯ ⎯ N/A
1250 and 1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0 ⎯ ⎯ N/A
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 ⎯ ⎯ N/A
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 ⎯ ⎯ N/A
1600 and 2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0 ⎯ ⎯ N/A
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 ⎯ ⎯ N/A
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 ⎯ ⎯ N/A
2000 and 2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0 ⎯ ⎯ N/A
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 ⎯ ⎯ N/A
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 ⎯ ⎯ N/A
>2500 and 3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0 ⎯ ⎯ N/A
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 ⎯ ⎯ N/A
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 ⎯ ⎯ N/A
3200 and 4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0 ⎯ ⎯ N/A
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 ⎯ ⎯ N/A
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 ⎯ ⎯ N/A
4000 and 5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0 ⎯ ⎯ N/A
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 ⎯ ⎯ N/A
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 ⎯ ⎯ N/A
5000 and 6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0 ⎯ ⎯ N/A
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 ⎯ ⎯ N/A
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 ⎯ ⎯ N/A
6300 and 8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0 ⎯ ⎯ N/A
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 ⎯ ⎯ N/A
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 ⎯ ⎯ N/A
8000 and 10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0 ⎯ ⎯ N/A
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 ⎯ ⎯ N/A
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 ⎯ ⎯ N/A
10000 and 12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0 ⎯ ⎯ N/A
Supplementary information:
*) Material group IIIb is allowed if the working voltage does not exceed 50 V
**) B = Basic insulation, S = Supplementary insulation, R = Reinforced insulation
1) Lacquered conductors of windings are considered to be bare conductors, but creepage distances need
not be greater than the associated clearance specified in Table 16 taking into account 29.1.1.
Appendix EMF P
TEST: Evaluation of the magnetic fields
Applied standards: IEC 62233:2005, EN 62233:2008 (incl. Corr.1:2008)
Method Used method: 5.5.2 Time domain evaluation —
Applied Limit ICNIRP Guidelines —
Identification of the appliance Type of apparatus Local air conditioner
Rated Voltage 220-240V
Rated Frequency 50Hz
Parameters required prior to the test Laboratory Ambient Temperature 25 °C ± 10 °C
Supply Voltage (Rated Voltage ± 2 %) V
Supply Frequency (Rated Frequency ± 2 %) Hz
Parameters recorded during the test Laboratory Ambient Temperature 25°C
Supply Voltage 230V
Supply Frequency 50Hz
Operating Mode
Method 5.5.2
Measuring Positions Measuring Distance Coupling Factor Measurement Uncertainty
Around 30cm — —
Frequency (kHz) Limit (%) Measured Maximum Value (%)
0,01 to 400 100 1,674%
Supplementary information:
The measured maximum value in this table may be weighted with the coupling factor if applicable, and the
measurement uncertainty is applied if the measured result is more than 75 % of the limit.
Photo documents:
Rear view
Control panel
Internal view
Internal view
Internal view
Earthing marking
Control board
Control board
Control board
Electric box
Internal view of electric box (main board and main board (high voltage board))
Note: the main board (M701F2Z) of model GPH12AL-K5NNA3A and main board (M701F1A) of model
GPC12AL-K5NNA3A of are same except main board (M701F1A) has deleting one relay which control 4-way
valve.
Fan motor
Compressor
Compressor marking
Note: The photos of model GPC12AL-K5NNA3A is same as photos of model GPH12AL-K5NNA3A except
GPC12AL-K5NNA3A has not 4-way valve.
Note: The other photos of models GPC12AL-K5NNA3B, GPH12AL-K5NNA2B can reference the photos of
models GPC12AL-K5NNA3A, GPH12AL-K5NNA3A for details.
Note: Other photos of model GPH12AL-K5NNA3C can reference photos of model GPH12AL-K5NNA2B.
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
Appendix
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
Norway ----
19.5 The test is also applicable to appliances intended to N/A
be permanently connected to fixed wiring
Norway ----
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
Ireland ----
25.6 These regulations apply to all plugs for domestic N/A
use at a voltage of not less than 200 V and in
general allow only plugs complying with I.S.
401:1997, or equivalent, to be fitted to domestic
appliances
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
Appendix
Variations to EN 60335-1:2012/A13:2017
ZZA ANNEX ZZA (INFORMATIVE) ----
REALATIONSHIP BETWEEN THIS EUROPEAN STANDARD AND THE SAFETY
OBJECTIVES OF DIRECTIVE 2014/35/EU [2014 OJ L96] AIMED TO BE
COVERED
Description relating to harmonized standards in the P
field of the Low Voltage Directive, M/511, to provide
one voluntary means of conforming to safety
objectives of Directive 2014/35/EU of the European
Parliament and of the Council of 26 February 2014
on the harmonization of the laws of the Member
States relating to the making available on the
market of electrical equipment designed for use
within certain voltage limits [2014 OJ L96]
A table with correspondence between this P
European standard and Annex I of Directive
2014/35/EU [2014 OJ L96]
ZZB ANNEX ZZB (INFORMATIVE) ----
REALATIONSHIP BETWEEN THIS EUROPEAN STANDARD AND THE
ESSENTIAL REQUIREMENTS OF DIRECTIVE 2006/42/EC AIMED TO BE
COVERED
Description relating to Mandate for standardisation N/A
in the field of machinery “M/396” to provide one
voluntary means of conforming to essential
requirements of EU Directive 2006/42/EC
A table with correspondence between this N/A
European standard and Annex I of Directive
2006/42/E [OJ No L 157]
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
Appendix
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-40
Clause Requirement + Test Result - Remark Verdict