Test Report issued under the responsibility of:

TEST REPORT
IEC 60335-2-40 / EN 60335-2-40
Safety of household and similar electrical appliances
Part 2: Particular requirements for electrical heat pumps, air conditioners and
dehumidifier
Report Reference No...................... :

GZ12100571-1R3

Date of issue..................................... :

June 24, 2013

Total number of pages ......................

139

CB Testing Laboratory................... :

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch

Address ............................................ :

Block E, No.7-2 Guang Dong Software Science Park, Caipin Road,


Guangzhou Science City, GETDD, Guangzhou, China

Applicants name............................ :

Gree Electric Appliances, Inc. of Zhuhai

Address ............................................ :

Jinji West Road, Qianshan, Zhuhai, Guangdong 519070, P. R.


China

Test specification:
Standard ........................................... :

IEC 60335-2-40:2002 (Edition 4) + A1:2005 + A2:2005 with


IEC 60335-1:2001 (incl. Corrigendum 1:2002) + A1:2004 +
A2:2006 (See Appendix to TRF no. IECEN60335_2_40B) and/or
EN 60335-2-40:2003 + A11:2004 + A12:2005 + A1:2006 +
A2:2009 (See Appendix to TRF no. IECEN60335_2_40B) with
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 (See
Appendix to TRF no. IECEN60335_2_40B) + A2:2006 (See
Appendix to TRF no. IECEN60335_2_40B) + A13:2008 (See
Appendix to TRF no. IECEN60335_2_40B) + A14:2010 (See
Appendix to TRF no. IECEN60335_2_40B) + A15:2011 (See
Appendix to TRF no. IECEN60335_2_40B)
EN 62233:2008 (See Appendix to TRF no. IECEN60335_2_40B)

Test procedure ................................. :

LVD

Non-standard test method..:

N/A

Test Report Form No...................... :

IECEN60335_2_40B

Test Report Form(s) Originator ........ :

VDE

Master TRF ...................................... :

Dated 2006-11

Copyright 2006 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme
procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended
to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be
removed.
This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and
appended to a CCA Test Certificate issued by an NCB in accordance with CCA

TRF No. IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 3 of 139

Report. No.: GZ12100571-1R3

Tests performed (name of test and test clause):

Testing location:

Original:
Full tests were conducted on model GWH24RDK3DNA3C.

Intertek Testing Services Shenzhen Ltd.


Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science
Park, Caipin Road, Guangzhou Science City,
GETDD, Guangzhou, China

A construction check was conducted on all the


models.
Clause 32 was conducted on model GWH24RDK3DNA3C according to the standard of EN 603352-65.

Gree Electric Appliances, Inc. of Zhuhai


Jinji West Road, Qianshan, Zhuhai, Guangdong
519070, P. R. China

Modification 1:
Test of clause 10 was conducted on model
GWH24RD-K3DNA8C.
Modification 2:
After review, no test was needed.
Modification 3:
After review, no test was needed.
The product was tested complies with the
requirements of these standards.
Summary of compliance with National Differences: N/A
Copy of marking plate:

TRF No. IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 4 of 139

Report. No.: GZ12100571-1R3

TRF No. IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 5 of 139

Report. No.: GZ12100571-1R3

TRF No. IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 6 of 139

Report. No.: GZ12100571-1R3

Test item particulars .................................................. : Split type air conditioner


Classification of installation and use ............................ : Fixed appliance
Supply Connection........................................................ : Permanently connected to fixed wiring
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object..................: N/A
- test object does meet the requirement .......................: P (Pass)
- test object does not meet the requirement .................: F (Fail)
Testing ..........................................................................:
Date of receipt of test item ............................................: June 08, 2013
Date (s) of performance of tests ...................................: June 08, 2013 June 24, 2013

General remarks:

TRF No. IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 7 of 139
Report. No.: GZ12100571-1R3
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
(See Enclosure #) refers to additional information appended to the report.
(See appended table) refers to a table appended to the report.
Note: EN Group Differences together with National Differences and Special National Conditions, if
any, are in the Appendix to the main body of this TRF.
Throughout this report a comma is used as the decimal separator.
When determining the test result, measurement uncertainty has been considered.
Note: The Requirements of IEC 60335-2-40 and EN 60335-2-40 in clause 15 are by identical content
different numbered. For better handling the column Clause contains an additional Information
IEC or EN.
This report is for the exclusive use of Interteks Client and is provided pursuant to the agreement between
Intertek and its Client. Interteks responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first
be approved in writing by Intertek. The observations and test results in this report are relevant only to the
sample tested. This report by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.
The test report only allows to be revised only within the report defined retention period unless standard or
regulation was withdrawn or invalid.
General product information:
Manufacturing Site: Gree Electric Appliances, Inc. of Zhuhai
Jinji West Road, Qianshan, Zhuhai, Guangdong 519070, P.R. China
Original:
The appliances are split type, inverter, wall mounted air-conditioner with cooling and heating operate mode
intend for household use. The indoor unit must be installed at the height of 2,5m above the floor of indoor
and outdoor unit must be installed at outdoor side.
The power supplied by indoor unit via a supply lead permanently connected to fixed wiring, and the indoor
unit and outdoor unit via interconnection cords for communication of power supply and signal.
Model differences:
GWH24RD-K3DNA2C is the same as GWH24RD-K3DNA3C except front panel of indoor unit.
Model list:
Model name

Indoor unit

GWH24RD-K3DNA3C

GWH24RD-K3DNA3C/I

GWH24RD-K3DNA2C

GWH24RD-K3DNA2C/I

Outdoor unit
GWH24RD-K3DNA3C/O

Modification 1:
This test report replaces the original test report GZ12100571-1, dated on December 19, 2012, it is issued
for the following changes:
1. Changed the Heating Rated Input from 2700W to 4000W on the nameplate of GWH24RDK3DNA3C/O for models GWH24RD-K3DNA2C and GWH24RD-K3DNA3C.
2.

Added 3 new models GWH24RD-K3DNA6C, GWH24RD-K3DNA8C and GWH24RD-K3DBA5E.


Model GWH24RD-K3DNA6C is identical to GWH24RD-K3DNA3C except front panel of indoor unit.
Models GWH24RD-K3DNA8C and GWH24RD-K3DBA5E are identical to GWH24RD-K3DNA3C
except front panel of indoor unit and power supplied, the new models are supplied by outdoor unit and
via interconnection cord for connecting of indoor and outdoor unit.

TRF No. IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 8 of 139
Report. No.: GZ12100571-1R3
The new model GWH24RD-K3DBA5E can be operated at the lower ambient of -20C than the original
model GWH24RD-K3DNA3C, and the new model employing heating element for chassis at outdoor
unit, refer to attach photo for details.
4. Added some components such as main board M846F2UEJ, interconnection cord and terminal blocks
for the new models, see table 24.1 for details, main board M846F2UEJ and M846F2TAJ are the same
as original M846F2TJ except control software that does not affect the safety of product.
Model list:
Model name
Indoor unit
Outdoor unit

3.

GWH24RD-K3DNA6C

GWH24RD-K3DNA6C/I

GWH24RD-K3DNA3C/O

GWH24RD-K3DNA8C

GWH24RD-K3DNA8C/I

GWH24RD-K3DNA8C/O

GWH24RD-K3DBA5E

GWH24RD-K3DBA5E/I

GWH24RD-K3DBA5E/O

Modification 2:
This test report replaces the original test report GZ12100571-1R1, dated on March 20, 2013, it is issued for
the following changes:
1. Added a new model GWH24RD-K3DBE1E which is identical to GWH24RD-K3DBA5E except for front
panel of indoor unit.
2. Corrected the weight of outdoor unit on the nameplate for model GWH24RD-K3DBA5E from 68kg to
63kg.
Model list:
Model name
Indoor unit
Outdoor unit
GWH24RD-K3DBE1E

GWH24RD-K3DBE1E/I

GWH24RD-K3DBA5E/O

Modification 3:
This test report replaces the original test report GZ12100571-1R2, dated on April 28, 2013, it is issued for
the following changes:
1. Added 2 new models GWH24RD-K3DNA5C and GWH24RD-K3DBA3E which are identical to
GWH24RD-K3DNA8C and GWH24RD-K3DBA5E respectively except for front panel of indoor unit.
2. Added alternative relays and Y capacitor, refer to Table 24.1 for details.
Model list:
Model name
Indoor unit
Outdoor unit
GWH24RD-K3DNA5C
GWH24RD-K3DBA3E

GWH24RD-K3DNA5C/I
GWH24RD-K3DBA3E/I

GWH24RD-K3DNA8C/O
GWH24RD-K3DBA5E/O

TRF No. IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 9 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

GENERAL CONDITIONS FOR THE TESTS

Result

Tests performed according to cl. 5, e.g. nature of


supply, sequence of testing, etc.
5.2

Verdict

If the test of Annex D has to be carried out, an


additional appliance may be used.
(IEC/EN 60335-1/A1)

N/A

The testing of Clause 21 to be carried out on


separate samples. The testing of Clauses 11, 19
and 21 required that pressure measurements be
made at various points in the refrigerating
system.
(IEC/EN 60335-2-40/A1)

At least one additional specially prepared


sample is required for the tests of Annex FF
(Leak simulation tests), if that test option is
selected
(IEC/EN 60335-2-40/A1)

N/A

The temperatures on the refrigerant piping is


measured during the test of Clause 11.
(IEC/EN 60335-2-40/A1)

5.3

The tests of Clause 14 and 21.2 and 22.24 are


carried out after the tests of Clause 29.
(IEC/EN 60335-1/A1)

N/A

5.6

Appropriate controls rendered inoperative during


the test
(IEC/EN 60335-2-40)

5.10

For split-package units, the refrigerant lines shall


be installed in accordance with the installation
instructions.. EC 60335-2-40:2002)

The refrigerant line length shall be the maximum


length stated in the installation instructions or 7,5
m, whichever is the shorter.
(IEC/EN 60335-2-40)

The thermal insulation of the refrigerant lines


shall be applied in accordance with the
installation instructions. (IEC/EN 60335-2-40)

5.14

NOTE: Guidance is given in Annex P for


enhanced requirements that may be used to
ensure an acceptable level of protection against
electrical and thermal hazards for particular
types of appliances used in an installation
without a protective earthing conductor in
countries that have warm damp equable
climates.
(IEC/EN 60335-1/A1)

5.101

Motor-compressor comply with IEC 60335-2-34


(IEC/EN 60335-2-40)

N/A

QXAS-D23zX090B

Motor-compressor subjected to the relevant test


(IEC/EN 60335-2-40)

P
N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 10 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

5.102

Motor compressors that are tested and comply


with IEC 60335-2-34 need not be additionally
tested for Clause 21. (IEC/EN 60335-2-40/A1)

CLASSIFICATION

6.1

Protection against electric shock:


Class I, II, III
(IEC/EN 60335-2-40)

6.2

Protection against harmful ingress of water, IP


degree in accordance with IEC 60529
(IEC/EN 60335-2-40)
Appliance for outdoor use
(IEC/EN 60335-2-40)

Result

Verdict
P

Class I

P
P

IP24 for outdoor unit

Appliance for indoor use


(IEC/EN 60335-2-40)

N/A

Appliance for laundry rooms


(IEC/EN 60335-2-40)

N/A

6.101

Degree of accessibility (accessible/not accessible


to the general public)
(IEC/EN 60335-2-40)

Accessible to the general


public

MARKING AND INSTRUCTIONS

7.1

Rated voltage or voltage range (V) ..........................: 220-240

Symbol for nature of supply including number of


~
phases, unless for single phase operation
(IEC/EN 60335-2-40)..........

Rated frequency (Hz) ...............................................: 50

Rated power input (W) .............................................: See page 2

Rated current (A) .....................................................:

N/A

Manufacturers or responsible vendors name,


GREE
trademark or identification mark ..............................:

Model or type reference ...........................................: See page 2

Symbol 5172 of IEC 60417, for Class II


appliances

Class I appliance

Symbol IEC 60417-5036, for the enclosure of


electrically-operated water valves in external
hose-sets for connection of an appliance to the
water mains
(IEC/EN 60335-1/A1)
Mass of the refrigerant or of each refrigerant in a
blend (except for azeotropic type)
(IEC/EN 60335-2-40):

N/A
N/A

See page 2

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 11 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Refrigerant identification
(IEC/EN 60335-2-40)

R410A

Verdict
P

Permissible excessive operating pressure for


sanitary hot water heat pumps
(IEC/EN 60335-2-40):

N/A

the maximum operating pressure for the heat


exchanger for hydronic fan coil/air handling
units;
(IEC 60335-2-40/A2) ....:

N/A

Discharge side: 4,3MPa;


Excessive operating pressure of the refrigerant
Suction side: 2,5MPa
circuit for suction and discharge, if they differ
(IEC/EN 60335-2-40)........:

Symbol for degree of protection against ingress of IP24 for outdoor unit
water, other than IPX0
(IEC/EN 60335-2-40):

Separate marking of the appliances with all the


rated characteristics of the supplementary heaters
(IEC/EN 60335-2-40):

N/A

Marking of the direction of the fluid flow


(IEC/EN 60335-2-40):

N/A

The flame symbol and the instruction manual symbol of 7.6 is visible when a
flammable refrigerant is employed and the following conditions exist:
(IEC/EN 60335-2-40/A1)

accessing parts expected to be subjected to


maintenance or repair;

N/A

observing the appliance under sale or installed


conditions;

N/A

observing the appliance packaging, if the


appliance is charged with refrigerant.

N/A

If a flammable refrigerant is used, the symbols


for reading the user manual, the repair manual
and the installation manual (symbols 3084, 3038
and 1785 of ISO 7000) shall be placed on the
appliance in a location visible to the persons
required to know the information. The
perpendicular height shall be at least 10 mm.
(IEC/EN 60335-2-40/A1)

N/A

An additional warning symbol (flame symbol:


B.3.2 of ISO 3864) shall be placed on the
nameplate of the unit near the declaration of the
refrigerant type and charge information. The
perpendicular height shall be at least 10 mm,
and the symbol need not be in colour.
(IEC/EN 60335-2-40/A1)

N/A

The following warning shall also be applied to


the appliance when a flammable refrigerant is
employed.
WARNING

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 12 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

Appliance shall be installed, operated and stored


in a room with a floor area larger than X m2
(only applies to appliances that are not fixed
appliances).
(IEC/EN 60335-2-40/A1)

7.2

7.3

For appliances, which are not fixed appliances,


the minimum room size X shall be specified on
the appliance. The X in the marking shall be
2
determined in m by the procedure described in
paragraph 2 of Annex GG for unventilated areas
and the X in the marking shall be 4 if the
refrigerant charge of the appliance is less than
m1 (see Annex GG, paragraph 1.1).
(IEC/EN 60335-2-40/A1)

N/A

The maximum allowable pressure for the lowpressure side and the high-pressure side is
marked on the product.
(IEC/EN 60335-2-40/A1)

N/A

If not already visible when accessing a service


port and if a service port is provided, the service
port shall be marked to identify the type of
refrigerant. If the refrigerant is flammable,
symbol B.3.2 of ISO 3864, shall be included,
without specifying the colour.
(IEC/EN 60335-2-40/A1)

N/A

Warning for stationary appliances for multiple


supply

N/A

Warning placed in vicinity of terminal cover

N/A

Range of rated values marked with the lower and


upper limits separated by a hyphen

Different rated values marked with the values


separated by an oblique stroke

N/A

7.4

Appliances adjustable for different rated voltages,


the voltage setting is clearly discernible

N/A

7.5

Appliances with more than one rated voltage or


one or more rated voltage ranges, marked with
rated input or rated current for each rated voltage
or range, unless

N/A

the power input is related to the mean value of the Replaced by IEC/EN 60335rated voltage range
1/A2:2006, See appendix
Relation between marking for upper and lower
limits of rated power input or rated current and
voltage is clear
7.6

Correct symbols used


When a flammable refrigerant is employed, a
warning symbol B.3.2 of ISO 3864, including
colour and format, shall be permanently placed
on the appliance. The perpendicular height of

--N/A

P
N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 13 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

the triangle containing the Caution, risk of fire


symbol shall be at least 30 mm.
(IEC/EN 60335-2-40/A1)
When a flammable refrigerant is employed, a
symbol requiring reference to the manual [B.3.2
of ISO 3864], including colour and format, shall
be permanently placed on the appliance.
(IEC/EN 60335-2-40/A1)

N/A

7.7

Connection diagram fixed to appliances to be


connected to more than two supply conductors
and appliances for multiple supply

7.8

Except for type Z attachment, terminals for connection to the supply mains
indicated as follows:

- marking of terminals exclusively for the neutral


conductor (N)

N/A

- marking of protective earthing terminals (symbol


5019 of IEC 60417)

- marking not placed on removable parts

7.9

Marking or placing of switches which may cause a


hazard

7.10

Indications of switches on stationary appliances


By use of figures, letters or
and controls on all appliances by use of figures,
other visual means
letters or other visual means ....................................:

The figure 0 indicates only OFF position, unless


no confusion with the OFF position

N/A

7.11

Indication for direction of adjustment of controls

7.12

Instructions for safe use provided

7.12.1

Classification of 6.101 included, for appliances not


accessible to general public
(IEC/EN 60335-2-40)

N/A

For appliances using flammable refrigerants, an


installation, service and operation manual, either
separate or combined manuals, shall be
provided and include the information given in
Annex DD.
(IEC/EN 60335-2-40/A1)

N/A

Sufficient details for installation or maintenance supplied

(IEC/EN 60335-2-40):

- national wiring regulations for installation

- dimensions of space for installation

- minimum clearance from appliances with


supplementary heaters to combustible surfaces
- wiring diagram

N/A
P

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 14 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

- range of external static pressures (only heat


pumps and appliances with electric resistance
heaters)

N/A

- method of connection to the electrical supply


and interconnection of separate components

- indication of suitable parts for outdoor use

- type and rated characteristics of fuses

- details of supplementary heating elements,


including fitting instructions

N/A

- maximum and minimum water or brine operating


temperatures

N/A

- maximum and minimum water or brine operating


pressures

N/A

- indication of open water storage tanks

N/A

For appliances not accessible to the general


public and which are intended to be permanently
connected to fixed wiring and which may have
leakage currents exceeding 10 mA, the
installation instructions shall specify the rating of
the residual current device (RCD) to be installed.
(EN 60335-2-40/A12)

N/A

7.12.2

Stationary appliances not fitted with means for


disconnection from the supply mains having a
contact separation in all poles that provide full
disconnection under overvoltage category III, the
instructions state that means for disconnection
must be incorporated in the fixed wiring in
accordance with the wiring rules

7.12.3

Insulation of the fixed wiring in contact with parts


exceeding 50 K during clause 11; instructions
stating that the fixed wiring must be protected

N/A

7.12.4

Instructions for built-in appliances:

- dimensions of space

N/A

- dimensions and position of supporting means

N/A

- distances between parts and surrounding


structure

N/A

- dimensions of ventilation openings and


arrangement

N/A

- connection to supply mains and interconnection


of separate components

N/A

- allow disconnection of the appliance after


installation, by accessible plug or a switch in the
fixed wiring, unless
(IEC/EN 60335-1/A1)

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 15 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

a switch complying with 24.3


(IEC/EN 60335-1/A1)

N/A

The disconnection may be achieved by having


the plug accessible or by incorporating a switch
in the fixed wiring in accordance with the wiring
rules.
(IEC/EN 60335-1/A1)

N/A

Replacement cord instructions, type X attachment


with a specially prepared cord

N/A

Replacement cord instructions, type Y attachment

Replacement cord instructions, type Z attachment

N/A

7.12.6

Caution in the instructions for heating appliances


with a non-self resetting thermal cut-out
(IEC/EN 60335-1/A1)

N/A

7.12.7

Instructions for fixed appliances stating how the


appliance is to be fixed (IEC/EN 60335-1/A1)

7.12.8

Instructions for appliances connected to the water mains:


(IEC/EN 60335-1/A1)

- max. inlet water pressure (Pa)


(IEC/EN 60335-1/A1):

N/A

- min. inlet water pressure, if necessary (Pa)


(IEC/EN 60335-1/A1):

N/A

Instructions concerning new and old hose-sets for


appliances connected to the water mains by
detachable hose-sets
(IEC/EN 60335-1/A1)

N/A

7.12.5

7.13

Instructions and other texts in an official language

In English

7.14

Marking clearly legible and durable

7.15

Marking on a main part

Marking clearly discernible from the outside, if


necessary after removal of a cover

For portable appliances, cover can be removed or


opened without a tool

N/A

For stationary appliances, name, trademark or


identification mark and model or type reference
visible after installation

For fixed appliances, name, trademark or


identification mark and model or type reference
visible after installation according to the
instructions

Indications for switches and controls placed on or


near the components. Marking not on parts which
can be positioned or repositioned in such a way
that the marking is misleading

Marking on panel allowed, provided panel in place

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 16 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

for intended operation of appliance


(IEC/EN 60335-2-40)
7.16

Marking of a possible replaceable thermal link or


fuse link clearly visible with regard to replacing the
link

N/A

7.101

Marking of fuses and overload protective devices, if replaceable


(IEC/EN 60335-2-40):

- fuse rated current in amperes, type and rated


voltage
(IEC/EN 60335-2-40)

N/A

- manufacturer and model of the overload


protective device
(IEC/EN 60335-2-40)

N/A

7.102

Marking for connection with aluminium wire, if


necessary
(IEC/EN 60335-2-40)

N/A

PROTECTION AGAINST ACCESS TO LIVE PARTS

8.1

Adequate protection against accidental contact


with live parts

8.1.1

Requirement applies for all positions, detachable


parts removed

Insertion or removal of lamps, protection against


contact with live parts of the lamp cap

N/A

Use of test probe B of IEC 61032: no contact with


live parts

Use of test probe 13 of IEC 61032 through


openings in class 0 appliances and class II
appliances/ constructions: no contact with live
parts

8.1.2

Test probe 13 also applied through openings in


earthed metal enclosures having a nonconductive coating: no contact with live parts

N/A

8.1.3

For appliances other than class II, use of test


probe 41 of IEC 61032: no contact with live parts
of visible glowing heating elements

N/A

8.1.4

Accessible part not considered live if:

- safety extra-low a.c. voltage: peak value not


exceeding 42.4 V

N/A

- safety extra-low d.c. voltage: not exceeding


42.4 V

For wireless remote controller


only.

- or separated from live parts by protective


impedance

N/A

If protective impedance: d.c. current not


exceeding 2 mA, and

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 17 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

8.1.5

8.2

Requirement Test

Result

Verdict

a.c. peak value not exceeding 0.7 mA

N/A

- for peak values over 42.4 V up to and including


450 V, capacitance not exceeding 0,1 F

N/A

- for peak values over 450 V up to and including


15 kV, discharge not exceeding 45 C

N/A

The quantity of electricity in the discharge is


measured using a resistor having a nominal noninductive resistance of 2 000
(IEC/EN 60335-1/A1)

N/A

Live parts protected at least by basic insulation before installation or assembly:

- built-in appliances

N/A

- fixed appliances

- appliances delivered in separate units

Class II appliances and constructions constructed


so that there is adequate protection against
accidental contact with basic insulation and metal
parts separated from live parts by basic insulation
only

Neither bare live parts nor basic isolated live parts are touchable with the test finger
through openings in the enclosure. The lead wires of plasma ion generator have
double insulation.

--

Internal basic insulation wires are well-fixed and supplementary insulation from
accessible screw.
Only possible to touch parts separated from live
parts by double or reinforced insulation

STARTING OF MOTOR-OPERATED APPLIANCES

Not applicable

N/A

(IEC/EN 60335-2-40)

10

POWER INPUT AND CURRENT

10.1

Power input at normal operating temperature,


rated voltage and normal operation not deviating
from rated power input by more than shown in
table 1

(see appended table)

10.2

Current at normal operating temperature, rated


voltage and normal operation not deviating from
rated current by more than shown in table 2

(see appended table)

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 18 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

11

HEATING

11.1

No excessive temperatures in normal use


(IEC/EN 60335-2-40)

Result

Verdict

Compliance is checked by the tests of Annex C, if

(IEC/EN 60335-2-40):

11.2

- temperature of motor winding exceeds values


shown in Table 3
(IEC/EN 60335-2-40)

N/A

- there is no doubt about the classification of the


insulation system of the motor
(IEC/EN 60335-2-40)

N/A

Placing and mounting of appliance

(IEC/EN 60335-2-40):

- clearances to adjacent surfaces

- flow rates for liquid source or sink equipment,


except for fan coils where the flow rates and
liquid temperatures shall be the maximum
specified in the manufacturers instructions;
(IEC 60335-2-40/A2)

N/A

- static pressures

N/A

- adjustable limit controls set at the maximum cutout setting and the minimum differential

N/A

For appliances with supplementary heaters, use


test casing of 11.9
(IEC/EN 60335-2-40)

N/A

11.2.1

For appliances with supplementary heaters, an


inlet duct is connected to the inlet air opening
(IEC/EN 60335-2-40)

N/A

11.2.2

Air outlet duct if necessary


(IEC/EN 60335-2-40)

N/A

11.3

Temperature rise determine by thermocouples or


resistance method (IEC/EN 60335-2-40)

11.4

Test performed at supply voltage between 0,94


and 1.06 times the rated voltage
(IEC/EN 60335-2-40)

11.5

11.6

P
1,06x240=254,4V

Heating appliances operated under normal


operation at 1.15 times rated power input
(IEC/EN 60335-2-40)

N/A

Test conducted in the heating mode and in the


cooling mode, if both exist
(IEC/EN 60335-2-40)

All supplementary heating elements operative


simultaneously
(IEC/EN 60335-2-40)

N/A

Defrost test in the most unfavourable conditions,

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 19 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test
if needed

Result

Verdict

(IEC/EN 60335-2-40)

11.7

Appliances operated continuously until steady


conditions except for defrost tests
(IEC/EN 60335-2-40)

11.8

Monitored temperatures not exceeding the values (See appended table)


of Table 3
(IEC/EN 60335-2-40)

Protective devices do not operate


(IEC/EN 60335-2-40)

However, components in protective electronic


circuits are allowed to operate provided they are
tested for the number of cycles of operation
specified in 24.1.4
(IEC/EN 60335-1/A1)

N/A

The temperature rise limit does not apply to


switches or controls tested in accordance with
the conditions occurring in the appliance.
(IEC/EN 60335-1/A1)

N/A

Sealing compound not flowing out


(IEC/EN 60335-2-40)

Temperature of the air in the outlet duct not


exceeding 90C
(IEC/EN 60335-2-40)

N/A

Test casing and installation of the rest of the


appliances in accordance with the manufacturers
instructions
(IEC/EN 60335-2-40)

N/A

Glass fibre insulation for appliances without


indication of minimum clearances according to the
manufacturer; the thermocouple in contact with
the enclosure
(IEC/EN 60335-2-40)

N/A

13

LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING


TEMPERATURE

13.1

Leakage current not excessive and electric


strength adequate

11.9

Heating appliances operated at 1.15 times rated


power input ...............................................................:

13.2

N/A

Motor-operated appliances and combined


1,06x240=254,4V
appliances supplied at 1.06 times rated voltage......:

Protective impedance and radio interference


filters disconnected before carrying out the tests

Leakage current measured by means of the


circuit described in figure 4 of IEC 60990

Leakage current measurements

(see appended table)

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 20 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

13.3

The appliance is disconnected from the supply


and the insulation is immediately subjected to a
voltage having a frequency of 50 Hz or 60 Hz for
1 min, in accordance with IEC 61180-1.
(IEC/EN 60335-1/A1)

Result

The high-voltage source used for the test is to


be capable of supplying a short circuit current Is
between the output terminals after the output
voltage has been adjusted to the appropriate
test voltage.(IEC/EN 60335-1/A1)

(see appended table)

The overload release of the circuit is not to be


operated by any current below the tripping
current Ir. The values of Is and Ir are given in
Table 5 for various high-voltage sources.
(IEC/EN 60335-1/A1)

(see appended table)

No breakdown during the tests

14

15.1

TRANSIENT OVERVOLTAGES

Appliances withstand the transient overvoltages to


which they may be subjected

N/A

Clearances having a value less than specified in


table 16 subjected to an impulse voltage test, the
test voltage specified in table 6

15

Verdict

(see appended table)

N/A

No flashover during the test, unless of functional


insulation

N/A

In case of flashover of functional insulation, the


appliance complies with clause 19 with the
clearance short circuited

N/A

MOISTURE RESISTANCE

(IEC) Enclosure provides the degree of moisture


protection against the ingress of water (rain,
overflow from the drain pan or defrosting, tests of
15.2, 15.3, 11.6 and Cl. 16)
(IEC/EN 60335-2-40)

N/A

(IEC) Motor-compressor not operated and detachable


parts are removed during 15.2 and 15.3
(IEC 60335-2-40/A2)

N/A

(EN) Enclosure provides the degree of moisture


protection against the ingress of water (rain,
overflow from the drain pan or defrosting, tests of
15.1.1, 15.1.2, 15.2, 11.6 and Cl. 16)
(EN 60335-2-40)

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 21 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

(EN) After test, water inside the enclosure has not


reduced the creepage distances and clearances
below the values of Cl. 29
(EN 60335-2-40)

15.1.2

15.2
15.1.1

Verdict
P

(EN) Water valves containing live parts and that are


incorporated in external hoses for connection of
an appliance to the water mains are subjected to
the test specified for IPX7 appliances.
(IEC/EN 60335-1/A1)

N/A

(EN) Appliances normally fixed to a ceiling are


mounted underneath a horizontal unperforated
support that is constructed to prevent water
spraying onto its top surface. The pivot axis of
the oscillating tube is located at the same level
as the underside of the support and aligned
centrally with the appliance. The spray is
directed upwards.
(IEC/EN 60335-1/A1)

N/A

(EN) For IPX4 appliances, the movement of the tube


is limited to two times 90 from the vertical for a
period of 5 min.
(IEC/EN 60335-1/A1)

(IEC) Tests in accordance with IEC 60529 in appliances IPX4 for outdoor unit
other than IPX0, as specified
(EN)
(IEC/EN 60335-2-40)

Spillage of liquid does not affect the electrical


insulation
(EN 60335-2-40)

N/A

Appliances with type X attachment fitted with a


flexible cord as described
(EN 60335-2-40)

N/A

Appliances incorporating an appliance inlet tested


with or without an connector, whichever is most
unfavourable
(EN 60335-2-40)

N/A

Detachable parts removed

N/A
(EN 60335-2-40)

Overfilling test with additional amount of


water, over a period of 1 min (l)...............................
(EN 60335-2-40)

N/A

The appliance withstands the electric strength test


of 16.3
(EN 60335-2-40)

N/A

No trace of water on insulation that can result in a


reduction of clearances and creepage distances
below values specified in clause 29
(EN 60335-2-40)

N/A

Drain pan filled to brim and subjected to


continuous overflow and fan(s) switched on
(EN 60335-2-40)

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 22 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause
15.3
15.2

Requirement Test

Result

(IEC) Drain pan filled to brim and subjected to


continuous overflow and fan(s) switched on
(EN)
(IEC/EN 60335-2-40)

15.101 (IEC) Spillage test as specified


(IEC 60335-2-40/A2)

Verdict
P

The appliance must be


installed on the height of 2,5m
or more above floor.

N/A

16

LEAKAGE CURRENT AND ELECTRIC STRENGTH

16.1

Leakage current not excessive and electric


strength adequate

Protective impedance disconnected from live


parts before carrying out the tests

Single-phase appliances: test voltage 1.06 times 1,06x240=254,4 V


rated voltage .............................................................:

16.2

Three-phase appliances: test voltage 1.06 times


rated voltage divided by 3.......................................:

16.3

N/A

Leakage current measurements

(see appended table)

Electric strength tests according to table 7

(see appended table)

No breakdown during the tests

17

18

OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED


CIRCUITS

No excessive temperatures in transformer or


associated circuits in event of short-circuits likely
to occur in normal use

N/A

(see appended table)

Appliance supplied with 1.06 or 0.94 times rated


voltage and the most unfavourable short-circuit or
overload likely to occur in normal use applied .........:

N/A

Temperature rise of insulation of the conductors


of safety extra-low voltage circuits not exceeding
the relevant value specified in table 3 by more
than 15 K

N/A

Temperature of the winding not exceeding the


value specified in table 8,

N/A

however limits do not apply to fail-safe


transformers complying with sub-clause 15.5 of
IEC 61558-1

N/A

ENDURANCE

Not applicable (IEC/EN 60335-2-40)

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 23 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

19

ABNORMAL OPERATION

19.1

The risk of fire or mechanical damage under


abnormal or careless operation obviated (tests
19.2-19.13)
(IEC/EN 60335-2-40)

Electronic circuits so designed and applied that a


fault will not render the appliance unsafe (electric
shock, fire or mechanical hazard, dangerous
malfunction) (test 19.11 and 19.12)
(IEC/EN 60335-2-40)

Test of appliance with motor rotors, other than


motor-compressors, operated for 15 days (360h)
or until a protection device opens the circuit
(IEC/EN 60335-2-40)

Insulation of motor windings


(see appended table of 19.2)
(IEC/EN 60335-2-40)........:

(see appended table of 19.2)

Temperature of the windings does not exceed the (see appended table of 19.2)
values shown in the table ; temperature (C)
(IEC/EN 60335-2-40)........:

Electric strength test as specified in 16.3, 72h


after the beginning of the test
(IEC/EN 60335-2-40)

A 30mA residual current device does not open


(IEC/EN 60335-2-40)

At the end, the leakage current between the


(see appended table of 19.2)
windings and the enclosure does not exceed 2mA
(IEC/EN 60335-2-40)

Motor-compressor complies with IEC 60335-2-34 QXAS-D23zX090B


(IEC/EN 60335-2-40)...............:

19.2

Temperature of enclosure does not exceed (C)


(IEC/EN 60335-2-40):

19.3

Result

Verdict

Test of the motor-compressor with the rotor


locked as specified in 19.101 of IEC 60335-2-34
(IEC/EN 60335-2-40)

N/A

19.4

Test of three-phase motors operated under the


conditions of Cl. 11 with one phase disconnected
until steady conditions
(IEC/EN 60335-2-40)

19.5

Test of appliance with heat transfer medium flow


of the outdoor heat exchanger restricted or shut
off when reaching steady conditions
(IEC/EN 60335-2-40)

Test of appliance with heat transfer flow of the


indoor heat exchanger restricted or shut off when
reaching steady conditions

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 24 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

(IEC/EN 60335-2-40)
Disconnection of the motor common to both the
outdoor and the indoor heat exchangers when
reaching steady conditions
(IEC/EN 60335-2-40)

N/A

19.6

Test of appliances using water as heat transfer


medium
(IEC/EN 60335-2-40)

N/A

19.7

The test of air to air appliances at rated voltage or


at the upper limit of the rated voltage range. The
dry-bulb temperature is 5K below the values
specified by the manufacturer
(IEC/EN 60335-2-40)

Test with the dry-bulb temperature 10K over the


values specified by the manufacturer
(IEC/EN 60335-2-40)

19.8

Test of appliances with supplementary electric


heaters
(IEC/EN 60335-2-40)

N/A

19.9

Test at a temperature permitting continuous


operation of the motor-compressor and the
electric heating elements at the same time
(IEC/EN 60335-2-40)

N/A

19.10

Test of the appliance with any defect which may


be expected during normal use
(IEC/EN 60335-2-40)

19.10.1

Test of 19.10 is repeated on class 01 appliances


and class 1 appliances incorporating tubular
sheathed or embedded heating elements.
(IEC/EN 60335-2-40/A1)

N/A

However, controls are not short-circuited but one


end of the element is connected to the sheath of
the heating element.
(IEC/EN 60335-2-40/A1)

N/A

The test is repeated with the polarity of the


supply to the appliance reversed and with the
other end of the element connected to the
sheath.
(IEC/EN 60335-2-40/A1)

N/A

The test is not carried out on appliances


intended to be permanently connected to fixed
wiring and on appliances where all-pole
disconnection occurs during the test of 19.10.
(IEC/EN 60335-2-40/A1)

N/A

The test of 19.10 is repeated on class 0I


appliances and class I appliances incorporating
tubular sheathed or embedded heating
elements.
(IEC 60335-2-40/A2)

N/A

19.10.101

However, controls are not short-circuited but one


end of the element is connected to the sheath of
the heating element.
TRF No.: IECEN60335_2_40B

N/A

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch


Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 25 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

(IEC 60335-2-40/A2)

19.11

19.11.1

19.11.2

The test is repeated with the polarity of the


supply to the appliance reversed and with the
other end of the element connected to the
sheath.
(IEC 60335-2-40/A2)

N/A

The test is not carried out on appliances


intended to be permanently connected to fixed
wiring and on appliances where an all-pole
disconnection occurs during the test of 19.10.
(IEC 60335-2-40/A2)

N/A

Electronic circuits, compliance checked by


evaluation of the fault conditions specified in
19.11.2 for all circuits or parts of circuits, unless
they comply with the conditions specified in
19.11.1
(IEC/EN 60335-2-40)

Appliances incorporating a protective electronic


circuit are subjected to the tests of 19.11.3 and
19.11.4. (IEC/EN 60335-1/A1)

N/A

Appliances having a switch with an off position


obtained by electronic disconnection, or a switch
that can place the appliance in a stand-by mode,
are subjected to the tests of 19.11.4.
(IEC/EN 60335-1/A1)

N/A

Windings temperature not exceeding values


shown in Table 6
(IEC/EN 60335-2-40)

Appliance shall comply with the conditions of


19.14
(IEC/EN 60335-2-40)

Appliance withstands the test : a conductor


becomes open circuited and three conditions are
met
(IEC/EN 60335-2-40)

N/A

Before applying the fault conditions a) to f) in 19.11.2, it is checked if circuits or


parts of circuit meet both of the following conditions
(IEC/EN 60335-2-40):

- the electronic circuit is a low-power circuit, that


is, the maximum power at low-power points does
not exceed 15W according to the tests specified
(IEC/EN 60335-2-40)

N/A

- the protection against electric shock, fire hazard,


mechanical hazard or dangerous malfunction in
other parts of the appliance does not rely on the
correct functioning of the electronic circuit
(IEC/EN 60335-2-40)

N/A

Fault conditions applied one at a time, the appliance operated under conditions
specified in Cl.11, but supplied at rated voltage, the duration of the tests as
specified
(IEC/EN 60335-2-40):

a) short circuit of creepage distances and


clearances between live parts of different
potential, if these distances are less than the

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 26 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

values specified in 29.1, unless the relevant part


is adequately encapsulated
(IEC/EN 60335-2-40)
b) open circuit at the terminals of any component
(IEC/EN 60335-2-40)

N/A

c) short circuit if capacitors, unless they comply


with IEC 60384-14
(IEC/EN 60335-2-40)

d) short circuit of any two terminals of an


electronic component, other than integrated
circuits. This fault condition is not applied between
the circuits of an optocoupler
(IEC/EN 60335-2-40)

e) failure of triacs in the diode mode


(IEC/EN 60335-2-40)

N/A

f) failure of an integrated circuit.


(IEC/EN 60335-1/A1)

N/A

Short-circuit of low-power circuits


(IEC/EN 60335-2-40)

N/A

In each case, the test is ended if a non-selfresetting interruption of the supply occurs within
the appliance. (IEC/EN 60335-1/A1)

N/A

The duration of the tests

(IEC/EN 60335-2-40) :

- as specified in 11.7 but only for one operating


cycle (in case the fault cannot be recognised by
user)
(IEC/EN 60335-2-40)

19.11.4

N/A

- as specified in 19.2, if fault can be recognised by


user
(IEC/EN 60335-2-40)

- until steady conditions are established


(IEC/EN 60335-2-40)

Test ended if interruption of supply occurs within


the appliance
(IEC/EN 60335-2-40)

Fault condition f) applied to encapsulated or


similar components
(IEC/EN 60335-2-40)

N/A

PTCs, NTCs and VDRs resistors not shortcircuited if used as specified by manufacturer
(IEC/EN 60335-2-40)

Appliances having a switch with an off position


obtained by electronic disconnection, or a switch
that can be placed in the stand-by mode, are
subjected to the tests of 19.11.4.1 to 19.11.4.7.
The tests are carried out with the appliance
supplied at rated voltage, the switch being set in
the off position or in the stand-by mode.
(IEC/EN 60335-1/A1)

Appliances incorporating a protective electronic


circuit are subjected to the tests of 19.11.4.1 to
TRF No.: IECEN60335_2_40B

N/A

N/A

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch


Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 27 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

19.11.4.7. The tests are carried out after the


protective electronic circuit has operated during
the relevant tests of Clause 19 except 19.2, 19.6
and 19.11.3. However, appliances that are
operated for 30 s or 5 min during the test of 19.7
are not subjected to the tests for electromagnetic
phenomena.
(IEC/EN 60335-1/A1)
The tests are carried out with surge arresters
disconnected, unless they incorporate spark gaps
(IEC/EN 60335-1/A1)

N/A

19.11.4.1

The appliance is subjected to electrostatic


discharges in accordance with IEC 61000-4-2,
test level 4 being applicable. Ten discharges
having a positive polarity and ten discharges
having a negative polarity are applied at each
preselected point
(IEC/EN 60335-1/A1)

N/A

19.11.4.2

The appliance is subjected to radiated fields in


accordance with IEC 61000-4-3, test level 3
being applicable.
(IEC/EN 60335-1/A1)

N/A

19.11.4.3

The appliance is subjected to fast transient bursts


in accordance with IEC 61000-4-4. Test level 3 s
applicable for signal and control lines. Test level 4
is applicable for the power supply lines. The
bursts are applied for 2 min with a positive polarity
and for 2 min with a negative polarity
(IEC/EN 60335-1/A1)

N/A

19.11.4.4

The power supply terminals of the appliance are


subjected to voltage surges in accordance with
IEC 61000-4-5, five positive impulses and five
negative impulses being applied at the selected
points. Test level 3 is applicable for the line-to-line
coupling mode, a generator having a source
impedance of 2 being used. Test level 4 is
applicable for the line-to-earth coupling mode, a
generator having a source impedance of 12
being used.
(IEC/EN 60335-1/A1)

N/A

Earthed heating elements in class I appliances


are disconnected during this test
(IEC/EN 60335-1/A1)

N/A

For appliances having surge arresters


incorporating spark gaps, the test is repeated at a
level that is 95 % of the flashover voltage
(IEC/EN 60335-1/A1)

N/A

19.11.4.5

The appliance is subjected to injected currents in


accordance with IEC 61000-4-6, test level 3 being
applicable. During the test, all frequencies
between 0,15 MHz to 80 MHz are covered.
(IEC/EN 60335-1/A1)

N/A

19.11.4.6

The appliance is subjected to voltage dips and

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 28 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

interruptions in accordance with IEC 61000-4-11.


The durations specified in Table 1 of IEC 610004-11 are applied to each test level, the dips and
interruptions being applied at zero crossing of the
supply voltage
(IEC/EN 60335-1/A1)
19.11.4.7

The appliance is subjected to mains signals in


accordance with IEC 61000-4-13, test level class
2 being applicable
(IEC/EN 60335-1/A1)

N/A

19.12

If the safety of the appliance for any of the fault


conditions specified in 19.11.2 depends on the
operation of a miniature fuse-link complying with
IEC 60127, the test is repeated but with fuse-link
replaced by an ammeter
(IEC/EN 60335-2-40)

Current 2,1 times rated current of fuse-link,


circuit not adequately protected (fuse-link shortcircuited)
(IEC/EN 60335-2-40)

N/A

Current 2,75 times rated current of fuse-link,


circuit adequately protected
(IEC/EN 60335-2-40)

Current 2,1 and 2,75 times rated current,


fuse-link short-circuited and test carried out during
specified time
(IEC/EN 60335-2-40)

N/A

19.13

Test of appliances with PTC heating elements


(IEC/EN 60335-2-40)

N/A

19.13

The appliance shall not undergo a dangerous


malfunction, and there shall be no failure of
protective electronic circuits if the appliance is
still operable.
(IEC/EN 60335-1/A1)

Replaced by EN 60335-2-40

---

Appliances tested with an electronic switch in the Replaced by EN 60335-2-40


off position, or in the stand-by mode, shall not
become operational
(IEC/EN 60335-1/A1)

---

Temperature rise shall not exceed the values


shown in Table 9
(IEC/EN 60335-2-40)

---

(See appended table)

Electric strength test, the test voltage as specified


in Table 4
(IEC/EN 60335-2-40)

---

19.14

During the tests of 19.2 to 19.10.1 and 19.11,


19.12 and 19.13 if appropriate, the appliances not
emit flames, molten metal, poisonous or ignitable
gas in hazardous amounts
(IEC 60335-2-40/A2)

19.101

All appliances provided with supplementary


heaters and with free air discharge are subjected
to the specified test in each mode of operation.

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 29 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

(IEC 60335-2-40/A2)
During the test the temperature shall not exceed
150 C but an overshoot of 25 C is permitted
during the first hour.
(IEC 60335-2-40/A2)

N/A

20

STABILITY AND MECHANICAL HAZARDS

20.1

Adequate stability

N/A

Tilting test through an angle of 10 (appliance


placed on an inclined plane/horizontal plane);
appliance does not overturn

N/A

Tilting test repeated on appliances with heating


elements, angle of inclination increased to 15

N/A

Possible heating test in overturned position;


temperature rise does not exceed values shown
in table 9

N/A

20.2

Moving parts adequately arranged or enclosed as


to provide protection against personal injury

Access to fan impeller of the outdoor unit is prevented by a grill, which is not
removable without using a tool. The test finger can not touch the fan impeller with a
force not more than 5N.

--

Protective enclosures, guards and similar parts


are non-detachable

Adequate mechanical strength and fixing of


protective enclosures

Self-resetting thermal cut-outs and overcurrent


protective devices not causing a hazard, by
unexpected reclosure

N/A

Not possible to touch dangerous moving parts


with test probe

21

MECHANICAL STRENGTH

21.1

Appliance has adequate mechanical strength and


is constructed as to withstand rough handling

Safety requirements of ISO 5149 applied


(IEC 60335-2-40/A2)

Safety requirements specified in Annex EE


applied. The pressure test in Annex EE applies
to parts other than pressure vessels.
(IEC/EN 60335-2-40/A1)

Checked by applying blows to the appliance in

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 30 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

accordance with test Ehb of IEC 60068-2-75,


spring hammer test, impact energy 0.5J
(IEC/EN 60335-1/A1)

21.2

If necessary, supplementary or reinforced


insulation subjected to the electric strength test of
16.3

N/A

If necessary, repetition of groups of three blows


on a new sample

N/A

Accessible parts of solid insulation shall have


sufficient strength to prevent penetration by sharp
implements.
(IEC/EN 60335-1/A1)

Compliance is checked by subjecting the


insulation to the following test, unless the
thickness of supplementary insulation is at least 1
mm and that of reinforced insulation is at least 2
mm.
(IEC/EN 60335-1/A1)

The insulation is raised to the temperature


measured during the test of Clause 11.
(IEC/EN 60335-1/A1)

N/A

The surface of the insulation is then scratched by


means of a hardened steel pin, the end of which
has the form of a cone with an angle of 40: Its t ip
is rounded with a radius of 0,25 mm 0,02 mm.
(IEC/EN 60335-1/A1)

N/A

The pin is held at an angle of 80 - 85 to the


horizontal and loaded so that the force exerted
along its axis is 10 N 0,5 N.
(IEC/EN 60335-1/A1)

N/A

The scratches are made by drawing the pin along


the surface of the insulation at a speed of
approximately 20 mm/s. Two parallel scratches
are made.
(IEC/EN 60335-1/A1)

N/A

They are spaced sufficiently apart so that they are


not affected by each other, their length covering
approximately 25 % of the length of the insulation.
(IEC/EN 60335-1/A1)

N/A

Two similar scratches are made at 90o to the first


pair without crossing them.
(IEC/EN 60335-1/A1)

N/A

The test fingernail of Figure 7 is then applied to


the scratched surface with a force of
approximately 10 N. No further damage, such as
separation of the material, shall occur. The
insulation shall then withstand the electric strength
test of 16.3.
(IEC/EN 60335-1/A1)

N/A

The hardened steel pin is then applied


perpendicularly with a force of 30 N 0,5 N to an
unscratched part of the surface. The insulation

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 31 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

shall then withstand the electric strength test of


16.3 with the pin still applied and used as one of
the electrodes.
(IEC/EN 60335-1/A1)

22

CONSTRUCTION

22.1

Appliance marked with the first numeral of the IP


system, relevant requirements of IEC 60529 are
fulfilled

22.2

Stationary appliance: means to provide all-pole disconnection from the supply


provided, the following means being available:

IP24 for outdoor unit

- a supply cord fitted with a plug

- a switch complying with 24.3

N/A

- a statement in the instruction sheet that a


disconnection incorporated in the fixed wiring is to
be provided

N/A

- an appliance inlet

N/A

Singe-pole switches and single-pole protective


devices for the disconnection of heating elements
in single-phase permanently connected class I
appliances, connected in the phase conductor
22.3

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Appliance provided with pins: no undue strain on


socket-outlets

N/A

Applied torque not exceeding 0.25 Nm

N/A

Pull force of 50N to each pin after the appliance


has being placed in the heating cabinet; when
cooled to room temperature the pins are not
displaced by more than 1mm

N/A

Each pin subjected to a torque of 0.4Nm; the pins


are not rotating unless rotating does not impair
compliance with the standard

N/A

22.4

Appliance for heating liquids and appliance


causing undue vibration not provided with pins for
insertion into socket-outlets

N/A

22.5

The appliance is supplied at rated voltage. Any


Replaced by IEC/EN 60335switch is then placed in the off position and the
1/A2:2006, See appendix
appliance is disconnected from the supply mains
at the instant of voltage peak. One second after
disconnection, the voltage between the pins of
the plug is measured with an instrument that
does not appreciably affect the value to be
measured.
(IEC/EN 60335-1/A1)

---

The voltage shall not exceed 34 V

---

Replaced by IEC/EN 603351/A2:2006, See appendix

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 32 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

22.6

Electrical insulation not affected by condensing


water or leaking liquid

Electrical insulation of Class II appliances not


affected in case of a hose rupture or seal leak

N/A

Electrical insulation not affected by snow


penetration to the appliance enclosure
(IEC/EN 60335-2-40)

22.7

Adequate safeguards against the risk of


excessive pressure in appliances provided with
steam-producing devices

22.8

Electrical connections not subject to pulling during


cleaning of compartments to which access can be
gained without the aid of a tool, and that are likely
to be cleaned in normal use

22.9

Insulation, internal wiring, windings, commutators


and slip rings not exposed to oil, grease or similar
substances

Adequate insulating properties of oil or grease to


which insulation is exposed

22.10

22.11

Not possible to reset voltage-maintained non-selfresetting thermal cut-outs by the operation of an


automatic switching device incorporated within the
appliance
(IEC/EN 60335-1/A1)

N/A

Non-self resetting thermal motor protectors have


a trip-free action, unless
(IEC/EN 60335-1/A1)

N/A

they are voltage maintained


(IEC/EN 60335-1/A1)

N/A

Location or protection of reset buttons of non-selfresetting controls is so that accidental resetting is


unlikely
(IEC/EN 60335-1/A1)

N/A

Reliable fixing of non-detachable parts that


provide the necessary degree of protection
against electric shock, moisture or contact with
moving parts

Obvious locked position of snap-in devices used


for fixing such parts

N/A

No deterioration of the fixing properties of snap-in


devices used in parts that are likely to be removed
during installation or servicing

N/A

Tests as described
22.12

N/A

Handles, knobs etc. fixed in a reliable manner

N/A

Fixing in wrong position of handles, knobs etc.


indicating position of switches or similar
components not possible

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 33 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

Axial force 15 N applied to parts, the shape being


so that an axial pull is unlikely to be applied

N/A

Axial force 30 N applied to parts, the shape being


so that an axial pull is likely to be applied

N/A

22.13

Unlikely that handles, when gripped as in normal


use, make the operators hand touch parts having
a temperature rise exceeding the value specified
for handles which are held for short periods only

N/A

22.14

No ragged or sharp edges creating a hazard for


the user in normal use, or during user
maintenance

No exposed pointed ends of self tapping screws


etc., liable to be touched by the user in normal
use or during user maintenance

22.15

Storage hooks and the like for flexible cords


smooth and well rounded

N/A

22.16

Automatic cord reels cause no undue abrasion or


damage to the sheath of the flexible cord, no
breakage of conductors strands, no undue wear
of contacts

N/A

Cord reel tested with 6000 operations, as


specified

N/A

Electric strength test of 16.3, voltage of 1000 V


applied

N/A

22.17

Spacers not removable from the outside by hand


or by means of a screwdriver or a spanner

N/A

22.18

Current-carrying parts and other metal parts


resistant to corrosion under normal conditions of
use

22.19

Driving belts not used as electrical insulation

N/A

22.20

Direct contact between live parts and thermal


insulation effectively prevented, unless material
used is non-corrosive, non-hygroscopic and noncombustible

N/A

Compliance is checked by inspection and, if


necessary, by appropriate test

N/A

22.21

Wood, cotton, silk, ordinary paper and fibrous or


hygroscopic material not used as insulation,
unless impregnated

22.22

Appliances not containing asbestos

22.23

Oils containing polychlorinated biphenyl (PCB) not


used

22.24

Bare heating elements adequately supported to


prevent contact with accessible metal parts in
case of rupture or sagging
TRF No.: IECEN60335_2_40B

N/A

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch


Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 34 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

(IEC/EN 60335-2-40)
Bare heating elements only used with metal
enclosures (wood or composite enclosures not
allowed)
(IEC/EN 60335-2-40)

N/A

22.25

Sagging heating conductors cannot come into


contact with accessible metal parts

N/A

22.26

The insulation between parts operating at safety


extra-low voltage and other live parts complies
with the requirements for double or reinforced
insulation

22.27

Parts connected by protective impedance


separated by double or reinforced insulation

N/A

22.28

Metal parts of Class II appliances conductively


connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insulation

N/A

22.29

Class II appliances permanently connected to


fixed wiring so constructed that the required
degree of access to live parts is maintained after
installation

N/A

22.30

Parts serving as supplementary or reinforced


insulation fixed so that they cannot be removed
without being seriously damaged, or

22.31

22.32

so constructed that they cannot be replaced in an


incorrect position, and so that if they are omitted,
the appliance is rendered inoperable or manifestly
incomplete

N/A

Clearances and creepage distances over


supplementary and reinforced insulation not
reduced below values specified in clause 29 as a
result of wear

Clearances and creepage distances between live


parts and accessible parts not reduced below
values for supplementary insulation, if wires,
screws etc. become loose

Supplementary and reinforced insulation designed


or protected against deposition of dirt or dust

Supplementary insulation of natural or synthetic


rubber resistant to ageing, or arranged and
dimensioned so that creepage distances are not
reduced below values specified in 29.2

N/A

Ceramic material not tightly sintered, similar


material or beads alone not used as
supplementary or reinforced insulation

N/A

Oxygen bomb test at 70 C for 96 h and 16 h at


room temperature

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 35 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

22.33

Conductive liquids that are or may become


accessible in normal use are not in direct contact
with live parts

Result

Verdict
P

Electrodes not used for heating liquids

N/A

For class II constructions, conductive liquids that


are or may become accessible in normal use, not
in direct contact with basic or reinforced insulation

For class II constructions, conductive liquids


which are in contact with live parts, not in direct
contact with reinforced insulation

N/A

22.34

Shafts of operating knobs, handles, levers etc. not


live, unless the shaft is not accessible when the
part is removed

N/A

22.35

Handles, levers and knobs, held or actuated in


normal use, not becoming live in the event of an
insulation fault

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Such parts being of metal, and their shafts or


Replaced by IEC/EN 60335fixings are likely to become live in the event of an 1/A2:2006, See appendix
insulation fault, they are either adequately covered
by insulation material, or their accessible parts are
separated from their shafts or fixings by
supplementary insulation

---

This requirement does not apply to handles,


levers and knobs on stationary appliances other
than those of electrical components, provided
they are either reliably connected to an earthing
terminal or earthing contact, or separated from
live parts by earthed metal

N/A

22.36

Handles continuously held in the hand in normal


use are so constructed that when gripped as in
normal use, the operators hand is not likely to
touch metal parts, unless they are separated from
live parts by double or reinforced insulation

N/A

22.37

Capacitors in Class II appliances not connected to


accessible metal parts, unless complying with
22.42

N/A

Metal casings of capacitors in Class II appliances


separated from accessible metal parts by
supplementary insulation, unless complying with
22.42

N/A

22.38

Capacitors not connected between the contacts of


a thermal cut-out

22.39

Lamp holders used only for the connection of


lamps

N/A

22.40

Motor-operated appliances and combined


appliances intended to be moved while in
operation, or having accessible moving parts,

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 36 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

fitted with a switch to control the motor. The


actuating member of the switch being easily
visible and accessible
22.41

No components, other than lamps, containing


mercury

22.42

Protective impedance consisting of at least two


separate components

N/A

Values specified in 8.1.4 not exceeded if any one


of the components are short-circuited or opencircuited

N/A

22.43

Appliances adjustable for different voltages,


accidental changing of the setting of the voltage
unlikely to occur

N/A

22.44

Appliances are not allowed to have an enclosure


that is shaped and decorated so that the
appliance is likely to be treated as a toy by
children

22.45

When air is used as reinforced insulation,


clearances not reduced below the values
specified in 29.1.4 due to deformation as a result
of an external force applied to the enclosure

22.46

Software used in protective electronic circuits is


software class B or C
(IEC/EN 60335-1/A1):

N/A

22.47

Appliances connected to the water mains


withstand the water pressure expected in normal
use
(IEC/EN 60335-1/A1)

N/A

No leakage from any part, including any inlet


water hose
(IEC/EN 60335-1/A1)

N/A

22.48

Appliances connected to the water mains


constructed to prevent backsiphonage of nonpotable water
(IEC/EN 60335-1/A1)

N/A

22.101

Appliances intended to be fixed, securely fixed


(IEC/EN 60335-2-40)

22.102.1

Double thermal cut-out in appliances with


supplementary heating elements for air (the first
one shall be a self-resetting and the other a nonself-resetting thermal cut-out)
(IEC 60335-2-40/A2)

Replaced by EN 60335-240/A2: 2009, See appendix

---

Thermal cut-outs comply with 24.3 (switches)


(IEC/EN 60335-2-40)

Replaced by EN 60335-240/A2: 2009, See appendix

---

Thermal cut-outs operating in Cl. 19 shall be of


the non-self-resetting type
(IEC/EN 60335-2-40)

Replaced by EN 60335-240/A2: 2009, See appendix

---

Appliances provided with supplementary heaters Replaced by EN 60335-2for water incorporate a non-self-resetting
40/A2: 2009, See appendix
thermal cut-out, providing all-pole disconnection

---

22.102.2

Replaced by IEC/EN 603351/A2:2006, See appendix

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 37 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

that operates separately from water thermostats.


(IEC 60335-2-40/A2)
However, for appliances intended to be
connected to fixed wiring, the neutral conductor
need not be disconnected.
(IEC 60335-2-40/A2)

Replaced by EN 60335-240/A2: 2009, See appendix

---

22.102.3

Thermal cut-outs of the capillary type open in the


event of leakage of the capillary tube
(IEC 60335-2-40/A2)

Replaced by EN 60335-240/A2: 2009, See appendix

---

22.103

Non-self-resetting cut-outs independent of other


control devices
(IEC/EN 60335-2-40)

N/A

22.104

Containers of sanitary hot water heat pumps


withstand twice the permissible pressure in closed
containers of 0,15MPa in open containers, without
leakage or rupture
(IEC/EN 60335-2-40)

N/A

22.105

Air or vapour cushion in closed containers not


exceeding the 10%
(IEC/EN 60335-2-40)

N/A

22.106

Pressure relief devices operating at 0,1MPa over


the permissible pressure
(IEC/EN 60335-2-40)

N/A

22.107

Water outlet systems of open containers free from


obstruction causing over-pressure
(IEC/EN 60335-2-40)

N/A

Vented containers of sanitary hot water heat


pumps always open to the atmosphere through
appropriate aperture
(IEC/EN 60335-2-40)

N/A

22.108

Not vented open containers are subjected to a


test in accordance with 22.104 to a vacuum of
33kPa for 15 min
(IEC/EN 60335-2-40)

N/A

22.109

Replacement of non-self-resetting thermal cutouts does not damage other connections


(IEC/EN 60335-2-40)

N/A

22.110

Non-self-resetting thermal cut-outs operate


without short-circuiting live parts of different
potential and without causing contact between live
parts and the enclosure
(IEC/EN 60335-2-40)

N/A

Test repeated five times without blowing a 3 A


fuse which connects the appliance to earth
(IEC/EN 60335-2-40)

N/A

Electric strength test as specified in 16.3 for


supplementary heating elements
(IEC/EN 60335-2-40)

N/A

Manual resetting of thermostats not necessary


after power supply interruption
(IEC/EN 60335-2-40)

N/A

22.111

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 38 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

22.112

The construction of the refrigerating system


comply with the requirements of Section 3 of
ISO 5149.
(IEC/EN 60335-2-40/A1)

22.113

When a flammable refrigerant is used,


refrigerant tubing is protected or enclosed to
avoid mechanical damage.
(IEC/EN 60335-2-40/A1)

N/A

The tubing is protected to the extent that it will


not be handled or used for carrying during
moving of the product
(IEC/EN 60335-2-40/A1)

N/A

Tubing located within the confines of the cabinet


is considered to be protected from mechanical
damage. (IEC/EN 60335-2-40/A1)

N/A

22.114

When a flammable refrigerant is used, low


temperature solder alloys, such as lead/tin
alloys, are not acceptable for pipe connections.
(IEC/EN 60335-2-40/A1)

N/A

22.115

The total refrigerant mass (M) of all refrigerating


systems within the appliance employing
flammable refrigerants, not exceed m3 as
defined in Annex GG.
(IEC/EN 60335-2-40/A1)

N/A

22.116

Appliances using flammable refrigerants


constructed so that any leaked refrigerant will
not flow or stagnate so as to cause a fire or
explosion hazard in areas within the appliance
where electrical components, which could be a
source of ignition and which could function under
normal conditions or in the event of a leak, are
fitted.
(IEC/EN 60335-2-40/A1)

N/A

Separate components, such as thermostats,


which are charged with less than 0,5 g of a
flammable gas are not considered to cause a
fire or explosion hazard in the event of leakage
of the gas within the component itself.
(IEC/EN 60335-2-40/A1)

N/A

All electrical components that could be a source of ignition and which could
function under normal conditions or in the event of a leak, comply with one of the
following:
(IEC/EN 60335-2-40/A1)

IEC 60079-15:2001, Clauses 9 to 26, for group


IIA gases or the refrigerant used or an applicable
standard that makes electrical components
suitable for use in Zone 2, 1 or 0 as defined in
IEC 60079-14.
(IEC/EN 60335-2-40/A1)

N/A

Not be located in an area where a potentially


flammable gas mixture will accumulate as
demonstrated by the test of Annex FF

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 39 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

(IEC/EN 60335-2-40/A1)
Be located in an enclosure. The enclosure
containing the electrical components comply
with IEC 60079-15:2001 for enclosures suitable
for use with group IIA gases or the refrigerant
used.
(IEC/EN 60335-2-40/A1)

N/A

22.117

Temperatures on surfaces that may be exposed


to leakage of flammable refrigerants shall not
exceed the auto-ignition temperature of the
refrigerant reduced by 100 K; some typical
values are given in Annex BB.
(IEC/EN 60335-2-40/A1)

N/A

22.118

When a flammable refrigerant is used, all


appliances charged with refrigerant at the
manufacturing location or charged on site as
recommended by the manufacturer.
(IEC/EN 60335-2-40/A1)

N/A

A part of an appliance that is charged on site,


which requires brazing or welding in the
installation shall not be shipped with a
flammable refrigerant charge. Joints made in the
installation between parts of the refrigerating
system, with at least one part charged, made in
accordance with the following.
(IEC/EN 60335-2-40/A1)

N/A

A brazed, welded, or mechanical connection


shall be made before opening the valves to
permit refrigerant to flow between the
refrigerating system parts. A vacuum valve shall
be provided to evacuate the interconnecting pipe
and/or any uncharged refrigerating system part.
(IEC/EN 60335-2-40/A1)

N/A

Reusable mechanical connectors and flared


joints are not allowed indoors.
(IEC/EN 60335-2-40/A1)

N/A

Refrigerant tubing shall be protected or


enclosed to avoid damage.
(IEC/EN 60335-2-40/A1)

N/A

Flexible refrigerant connectors (such as


connecting lines between the indoor and outdoor
unit) that may be displaced during normal
operations shall be protected against
mechanical damage. (IEC/EN 60335-2-40/A1)

N/A

23

INTERNAL WIRING

23.1

Wireways smooth and free from sharp edges

Wires protected against contact with burrs,

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 40 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

cooling fins etc.

23.2

Wire holes in metal well rounded or provided with


bushings

Wiring effectively prevented from coming into


contact with moving parts

Beads etc. on live wires cannot change their


position, and are not resting on sharp edges or
corners

N/A

Beads inside flexible metal conduits contained


within an insulating sleeve

N/A

Electrical connections and internal conductors


movable relatively to each other not exposed to
undue stress

N/A

Flexible metallic tubes not causing damage to


insulation of conductors

N/A

Open-coil springs not used

N/A

Adequate insulating lining provided inside a coiled


spring, the turns of which touch one another

N/A

No damage after 10 000 flexings for conductors


flexed during normal use or 100 flexings for
conductors flexed during user maintenance

N/A

Electric strength test, 1000 V between live parts


and accessible metal parts

N/A

23.4

Bare internal wiring sufficiently rigid and fixed

N/A

23.5

The insulation of internal wiring withstanding the


electrical stress likely to occur in normal use

No breakdown when a voltage of 2000 V is


applied for 15 min between the conductor and
metal foil wrapped around the insulation

23.6

Sleeving used as supplementary insulation on


internal wiring retained in position by positive
means

23.7

The colour combination green/yellow used only for


earthing conductors

23.8

Aluminium wires not used for internal wiring

23.9

No lead-tin soldering of stranded conductors


where they are subject to contact pressure,
unless

23.3

clamping means so constructed that there is no


risk of bad contact due to cold flow of the solder
23.10

The insulation and sheath of internal wiring,


incorporated in external hoses for the connection
of an appliance to the water mains, at least
equivalent to that of light polyvinyl chloride
TRF No.: IECEN60335_2_40B

N/A
N/A

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch


Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 41 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

sheathed flexible cord (60227 IEC 52)


(IEC/EN 60335-1/A1)

24

COMPONENTS

24.1

Components comply with safety requirements in


relevant IEC standards

Replaced by IEC/EN 603351/A14: 2010, See appendix

---

List of components

Replaced by IEC/EN 603351/A14: 2010, See appendix

---

Components not tested and found to comply with


relevant IEC standard for the number of cycles
specified are tested in accordance with 24.1.1 to
24.1.6

Replaced by IEC/EN 603351/A14: 2010, See appendix

---

Components not tested and found to comply with Replaced by IEC/EN 60335relevant IEC standard, components not marked or 1/A14: 2010, See appendix
not used in accordance with its marking, tested
under the conditions occurring in the appliance

---

Motor-compressors not tested according to IEC


60335-2-34 (not necessary to meet all
requirements of IEC 60335-2-34)
(IEC/EN 60335-2-40)
24.1.1

24.1.2

24.1.3

24.1.4

Capacitors likely to be permanently subjected to


the supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14, or

N/A

tested according to annex F

N/A

Safety isolating transformers complying with IEC


61558-2-6, or

N/A

tested according to annex G

N/A

Switches complying with IEC 61058-1, the


number of cycles of operation being at least
10 000, or

N/A

tested according to annex H

N/A

If the switch operates a relay or contactor, the


complete switching system is subjected to the test

N/A

Automatic controls complying with IEC 60730-1 with relevant part 2. The number of
cycles of operation being:

- thermostats:

10 000

N/A

- temperature limiters:

1 000

N/A

- self-resetting thermal cut-outs


(IEC/EN 60335-2-40):

3 000

N/A

- voltage maintained non-self-resetting thermal


cut-outs:
1000

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 42 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

- other non-self-resetting thermal cut-outs:


(IEC/EN 60335-2-40):
300

N/A

- timers:

3 000

N/A

:10 000

N/A

- energy regulators

- thermostats which control motor-compressor


(IEC/EN 60335-2-40):
100 000

N/A

- motor-compressor starting relays


(IEC/EN 60335-2-40):

N/A
100 000

- automatic thermal motor-protectors for hermetic


and semi-hermetic type motor-compressors
(IEC/EN 60335-2-40):
min 2 000

- manual reset thermal motor-protectors for


hermetic and semi-hermetic type motorcompressors (IEC/EN 60335-2-40):
50

N/A

- other automatic thermal motor protectors


(IEC/EN 60335-2-40):
2 000

- other manual reset thermal motor protectors


(IEC/EN 60335-2-40):
30

N/A

Thermal motor protectors are tested in


combination with their motor under the conditions
specified in Annex D
(IEC/EN 60335-1/A1)

N/A

For water valves containing live parts and that are


incorporated in external hoses for connection of
an appliance to the water mains, the degree of
protection declared for subclause 6.5.2 of IEC
60730-2-8 is IPX7
(IEC/EN 60335-1/A1)

N/A

Appliance couplers complying with IEC 60320-1

N/A

However, appliances classified higher than IPX0,


the appliance couplers complying with IEC 603202-3
(IEC/EN 60335-1/A1)

N/A

Interconnection couplers complying with IEC


60320-2-2

N/A

24.1.6

Small lamp holders similar to E10 lampholders


complying with IEC 60238, the requirements for
E10 lampholders being applicable

N/A

24.2

No switches or automatic controls in flexible cords

No devices causing the protective device in the


fixed wiring to operate in the event of a fault in the
appliance

No thermal cut-outs that can be reset by soldering

Switches intended for all-pole disconnection of


stationary appliances are directly connected to the

N/A

24.1.5

24.3

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 43 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

supply terminals and having a contact separation


in all poles, providing full disconnection under
overvoltage category III conditions
24.4

Plugs and socket-outlets for extra-low voltage


circuits and heating elements, not
interchangeable with plugs and socket-outlets
listed in IEC 60083 or IEC 60906-1 or with
connectors and appliance inlets complying with
the standard sheets of IEC 60320-1

24.5

Capacitors in auxiliary windings of motors marked


with their rated voltage and capacitance and used
accordingly
Voltage across capacitors in series with a motor
winding does not exceed 1,1 times rated voltage,
when the appliance is supplied at 1,1 times rated
voltage under minimum load

24.6

N/A

Measure voltage:
Indoor fan motor capacitor:
295 V (max.)
Limited: 495V

Working voltage of motors connected to the


supply mains and having basic insulation that is
inadequate for the rated voltage of the appliance,
not exceeding 42V.

N/A

In addition, the motors are complying with the


requirements of Annex I

N/A

24.7

Hose-sets for connection of appliances to the


water mains, complying with IEC 61770 and
supplied with the appliance
(IEC/EN 60335-1/A1)

N/A

24.101

Replaceable parts of thermal control devices


identified by marking
(IEC/EN 60335-2-40)

N/A

25

SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS

25.1

Appliance not intended for permanent connection to fixed wiring, means for
connection to the supply:

- pins for insertion into socket-outlets

N/A

- supply cord fitted with a plug may be provided, if


(IEC/EN 60335-2-40):

N/A

the appliance is only for indoor use

N/A

it is marked with a rating of 25 A or less

N/A

it complies with the code requirements of


the country where it will be used
Appliance inlet not allowed
(IEC/EN 60335-2-40)
25.2

Appliance not provided with more than one


means of connection to the supply mains

N/A
N/A
P

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 44 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Stationary appliance for multiple supply may be


provided with more than one means of
connection, provided electric strength test of
1250 V for 1 min between each means of
connection causes no breakdown
25.3

N/A

Connection of supply conductors for appliance


intended to be permanently connected to fixed
wiring possible after the appliance has been fixed
to its support

Appliance provided with a set of terminals for the


connection of cables or fixed wiring, crosssectional areas specified in 26.6

N/A

Appliance provided with a set of terminals


allowing the connection of a flexible cord

N/A

Appliance provided with a set of supply leads


accommodated in a suitable compartment

25.4

25.5

Verdict

Appliance provided with a set of terminals and


cable entries, conduit entries, knock-outs or
glands, allowing connection of appropriate type of
cable or conduit

N/A

Cable and conduit entries, rated current of


appliance not exceeding 16 A, dimensions
according to table 10

N/A

Introduction of conduit or cable does not reduce


clearances or creepage distances below values
specified in 29

N/A

Method for assemble supply cord with the appliance:

- type X attachment

N/A

- type Y attachment

- type Z attachment, if allowed in part 2

N/A

Type X attachment, other than those with a


specially prepared cord, not used for flat twin
tinsel cords

N/A

25.6

Plugs fitted with only one flexible cord

N/A

25.7

Supply cord not lighter than:

- braided cord (60245 IEC 51)

Replaced by IEC/EN 603351/A2:2006, See appendix

---

- ordinary tough rubber sheathed cord


(60245 IEC 53)

Replaced by IEC/EN 603351/A2:2006, See appendix

---

- ordinary polychloroprene sheathed flexible cord


(60245 IEC 57)
(IEC/EN 60335-1/A1)

Replaced by IEC/EN 603351/A2:2006, See appendix

---

- flat twin tinsel cord (60227 IEC 41)

Replaced by IEC/EN 603351/A2:2006, See appendix

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 45 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

- light polyvinyl chloride sheathed cord


(60227 IEC 52), appliance not exceeding 3 kg

Replaced by IEC/EN 603351/A2:2006, See appendix

---

- ordinary polyvinyl chloride sheathed cord


(60227 IEC 53), appliance exceeding 3 kg

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Temperature rise of external metal parts


exceeding 75 K, PVC cord not used, unless

Replaced by IEC/EN 603351/A2:2006, See appendix

---

appliance so constructed that the supply cord is


not likely to touch external metal parts in normal
use, or

Replaced by IEC/EN 603351/A2:2006, See appendix

---

the supply cord is appropriate for higher


temperatures, type Y or type Z attachment used

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Supply cords for outdoor use not lighter than


polychloroprene sheathed flexible cord (60245
IEC 57)
(IEC/EN 60335-2-40)

H07RN-F for interconnection


cord

25.8

Nominal cross-sectional area of supply cords


according to table 11; rated current (A); crosssectional area (mm) ................................................:

25.9

Supply cord not in contact with sharp points or


edges

25.10

Green/yellow core for earthing purposes in Class I


appliance

25.11

Conductors of supply cords not consolidated by


lead-tin soldering where they are subject to
contact pressure, unless

clamping means so constructed that there is no


risk of bad contacts due to cold flow of the solder

N/A

25.12

Moulding the cord to part of the enclosure does


not damage the insulation of the supply cord

N/A

25.13

Inlet opening so shaped as to prevent damage to


the supply cord

Unless the enclosure at the inlet opening is of


insulation material, a non-detachable lining or
bushing complying with 29.3 for supplementary
insulation provided

If unsheathed supply cord, a similar additional


bushing or lining is required, unless

N/A

the appliance is class 0

N/A

Supply cords adequately protected against


excessive flexing

N/A

Flexing test:

- applied force (N).....................................................:

N/A

- number of flexings..................................................

N/A

25.14

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 46 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

25.15

25.16

Requirement Test

Result

Verdict

The test does not result in:

- short circuit between the conductors

N/A

- breakage of more than 10% of the strands of


any conductor

N/A

- separation of the conductor from its terminal

N/A

- loosening of any cord guard

N/A

- damage, within the meaning of the standard, to


the cord or the cord guard

N/A

- broken strands piercing the insulation and


becoming accessible

N/A

Conductors of the supply cord relieved from


strain, twisting and abrasion by use of cord
anchorage

The cord cannot be pushed into the appliance to


such an extent that the cord or internal parts of
the appliance can be damaged

Pull and torque test of supply cord, values shown 100N; 0,35Nm
in table 12: pull (N); torque (not on automatic cord
reel) (Nm) .................................................................:

Max. 2 mm displacement of cord

Creepage distances and clearances not reduced


below values specified in 29.1

N/A

Cord anchorages for type X attachments constructed and located so that:

- replacement of the cord is easily possible

N/A

- it is clear how the relief from strain and the


prevention of twisting are obtained

N/A

- they are suitable for different types of cord

N/A

- cord cannot touch the clamping screws of cord


anchorage if these screws are accessible, unless
separated from accessible metal parts by
supplementary insulation

N/A

- the cord is not clamped by a metal screw which


bears directly on the cord

N/A

- at least one part of the cord anchorage securely


fixed to the appliance, unless part of a specially
prepared cord

N/A

- screws which have to be operated when


replacing the cord do not fix any other component,
if applicable

N/A

- if labyrinths can be bypassed the test of 25.15 is


nevertheless withstood

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 47 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

- for Class 0, 0I and I appliances: they are of


insulating material or are provided with an
insulating lining, unless a failure of the insulation
of the cord does not make accessible metal parts
live

N/A

- for Class II appliances: they are of insulating


material, or if of metal, they are insulated from
accessible metal parts by supplementary
insulation

N/A

Conductors not moved more than 1 mm in


terminals

N/A

25.17

Adequate cord anchorages for type Y and Z


attachment

25.18

Cord anchorages only accessible with the aid of a


tool, or

so constructed that the cord can only be fitted with


the aid of a tool

N/A

Type X attachment, glands not used as cord


anchorage in portable appliances

N/A

Tying the cord into a knot or tying the cord with


string not used

N/A

25.20

Conductors of the supply cord for type Y and Z


attachment adequately additionally insulated

25.21

Space for supply cord for type X attachment or for


connection of fixed wiring constructed to permit
checking of conductors with respect to correct
positioning and connection before fitting any
cover, no risk of damage to the conductors when
fitting the cover, no contact with accessible metal
parts if a conductor becomes loose, etc.

For portable appliances, the uninsulated end of a


conductor prevented from any contact with
accessible metal parts, unless the end of the cord
is such that the conductors are unlikely to slip free

N/A

Appliance inlet:

- live parts not accessible during insertion or


removal

N/A

- connector can be inserted without difficulty

N/A

- the appliance is not supported by the connector

N/A

- is not for cold conditions if temp. rise of external


metal parts exceeds 75 K, unless the supply cord
is not likely to touch such metal parts

N/A

25.19

25.22

25.23

Interconnection cords comply with the


requirements for the supply cord, except as

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 48 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

specified
If necessary, electric strength test of 16.3

N/A

25.24

Interconnection cords not detachable without the


aid of a tool if compliance with the standard is
impaired when they are disconnected

25.25

Dimensions of pins compatible with the


dimensions of the relevant socket-outlet.
Dimensions of pins and engagement face in
accordance with the relevant plug in IEC 60083

N/A

26

TERMINALS FOR EXTERNAL CONDUCTORS

26.1

Appliances provided with terminals or equally


effective devices for connection of external
conductors

26.2

26.3

Outdoor unit

Terminals only accessible after removal of a nondetachable cover

However, earthing terminals may be accessible if


a tool is required to make the connections and
means are provided to clamp the wire
independently from its connection
(IEC/EN 60335-1/A1)

N/A

Appliances with type X attachment and


appliances for connection to fixed wiring provided
with terminals in which connections are made by
means of screws, nuts or similar devices, unless
the connections are soldered

Screws and nuts serve only to clamp supply


conductors, except

internal conductors, if so arranged that they are


unlikely to be displaced when fitting the supply
conductors

N/A

If soldered connections used, the conductor so


positioned or fixed that reliance is not placed on
soldering alone

N/A

Soldering alone used, barriers provided,


clearances and creepage distances satisfactory if
the conductor becomes free at the soldered joint

N/A

Terminals for type X attachment and for


connection to fixed wiring so constructed that the
conductor is clamped between metal surfaces
with sufficient contact pressure and without
damaging the conductor

N/A

Terminals for type X attachment and those for connection to fixed wiring so fixed
that when tightening or loosening the clamping means:

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 49 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

- the terminal does not loosen

- internal wiring is not subjected to stress

- clearances and creepage distances are not


reduced below the values in 29

Compliance checked by inspection and by the test Replaced by IEC/EN 60335of subclause 8.6 of IEC 60999-1, the torque
1/A2:2006, See appendix
applied being equal to two-thirds of the torque
specified. Nominal diameter of thread (mm);
screw category; torque (Nm)....................................:

---

26.4

Terminals for type X attachment, except those


with a specially prepared cord, and those for
connection to fixed wiring, no special preparation
of conductors required, and so constructed or
placed that conductors prevented from slipping
out

26.5

Terminals for type X attachment so located or


shielded that if a wire of a stranded conductor
escapes, no risk of accidental connection to other
parts that result in a hazard

N/A

Stranded conductor test, 8 mm insulation


removed

N/A

No contact between live parts and accessible


metal parts and, for class II constructions,
between live parts and metal parts separated
from accessible metal parts by supplementary
insulation only

N/A

26.6

Terminals for type X attachment and for


Replaced by IEC/EN 60335connection to fixed wiring suitable for connection 1/A2:2006, See appendix
of conductors with required cross-sectional area
according to table 13; rated current (A); nominal
cross-sectional area (mm) ......................................:

---

Terminals only suitable for a specially prepared


cord

N/A

26.7

Terminals for type X attachment accessible after


removal of a cover or part of the enclosure

N/A

26.8

Terminals for the connection to fixed wiring,


including the earthing terminal, located close to
each other

26.9

Terminals of the pillar type constructed and


located as specified

N/A

26.10

Terminals with screw clamping and screwless


terminals not used for flat twin tinsel cords, unless
conductors ends fitted with a device suitable for
screw terminals

N/A

Pull test of 5 N to the connection

N/A

26.11

For type Y and Z attachment: soldered, welded,

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 50 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

crimped and similar connections may be used


For Class II appliances: the conductor so
positioned or fixed that reliance is not placed on
soldering, welding or crimping alone

N/A

For Class II appliances: soldering, welding or


crimping alone used, barriers provided,
clearances and creepage distances satisfactory if
the conductor becomes free

N/A

27

PROVISION FOR EARTHING

27.1

Accessible metal parts of Class 0I and I


appliances, permanently and reliably connected to
an earthing terminal or contact of the appliance
inlet

Earthing terminals not connected to neutral


terminal

27.2

27.3

27.4

Class 0, II and III appliance have no provision for


earthing

N/A

Safety extra-low voltage circuits not earthed,


unless protective extra-low voltage circuits

N/A

Clamping means adequately secured against


accidental loosening

Terminals used for the connection of external


equipotential bonding conductors allow
connection of conductors of 2.5 to 6 mm, and

N/A

do not provide earthing continuity between


different parts of the appliance

N/A

Conductors cannot be loosened without the aid of


a tool

N/A

For detachable parts that are plugged into another


part of the appliance, and having an earth
connection, the earth connection made before
and separated after current-carrying connections
when removing the part
(IEC/EN 60335-1/A1)

N/A

For appliances with supply cord, current-carrying


conductors become taut before earthing
conductor, if the cord slips out of the cord
anchorage

N/A

No risk of corrosion resulting from contact


between metal of earthing terminal and other
metal

Adequate resistance to corrosion of coated or


uncoated parts providing earthing continuity, other

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 51 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

than parts of a metal frame or enclosure

27.5

Parts of steel providing earthing continuity


provided at the essential areas with an
electroplated coating, thickness at least 5 m

Adequate protection against rusting of parts of


coated or uncoated steel, only intended to provide
or transmit contact pressure

In case of aluminium alloys precautions taken to


avoid risk of corrosion

N/A

Low resistance of connection between earthing


terminal and earthed metal parts

This requirement does not apply to connections


providing earthing continuity in the protective
extra-low voltage circuit, provided that clearances
of basic insulation are based on the rated voltage
of the appliance

27.6

N/A

Resistance not exceeding 0,1 at the specified


low-resistance test

0,05

The printed conductors of printed circuit boards


not used to provide earthing continuity in hand
held appliances

Replaced by IEC/EN 603351/A2:2006, See appendix

---

They may be used in other appliances if:

- at least two tracks are used with independent


soldering points and the appliance complies with
requirements of 27.5 for each circuit

Replaced by IEC/EN 603351/A2:2006, See appendix

---

- the material of the printed circuit board complies


with IEC 60249-2-4 or IEC 60249-2-5

Replaced by IEC/EN 603351/A2:2006, See appendix

---

28

SCREWS AND CONNECTIONS

28.1

Fixings, electrical connections and connections


providing earthing continuity withstand mechanical
stresses

Screws not of soft metal liable to creep, such as


zinc or aluminium

Diameter of screws of insulating material min.


3 mm

N/A

Screws of insulating material not used for any


electrical connection or connections providing
earthing continuity

N/A

Screws used for electrical connections or


connections providing earthing continuity screw
into metal
Screws not of insulating material if their
replacement by a metal screw can impair

No screws are insulation


material.

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 52 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

supplementary or reinforced insulation


Type X attachment, screws to be removed for
replacement of supply cord or for user
maintenance, not of insulating material if their
replacement by a metal screw can impair basic
insulation
For screws and nuts; test as specified
28.2

28.3

28.4

29

N/A

(see appended table)

Electrical connections and connections providing


earthing continuity constructed so that contact
pressure not transmitted through insulating
material liable to shrink or distort, unless
shrinkage or distortion compensated

P
P

This requirement does not apply to electrical


connections in circuits carrying a current not
exceeding 0.5A

N/A

Space-threaded (sheet metal) screws only used


for electrical connections if they clamp the parts
together

N/A

Thread-cutting (self-tapping) screws only used for Replaced by IEC/EN 60335electrical connections if they generate a full form
1/A2:2006, See appendix
standard machine screw thread

---

Such screws not used if they are likely to be


Replaced by IEC/EN 60335operated by the user or installer unless the thread 1/A2:2006, See appendix
is formed by a swaging action

---

Thread-cutting and space-threaded screws may


be used in connections providing earthing
continuity, provided unnecessary to disturb the
connection and at least two screws are used for
each connection

---

Replaced by IEC/EN 603351/A2:2006, See appendix

Screws and nuts that make mechanical


connection secured against loosening if they also
make electrical connections or connections
providing earthing continuity

Rivets for electrical connections or connections


providing earthing continuity secured against
loosening if subjected to torsion

N/A

CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION

Clearances, creepage distances and solid


insulation withstand electrical stress

For coatings used on printed circuits boards to


Replaced by IEC/EN 60335protect the microenvironment (Type A) or to
1/A2:2006, See appendix
provide basic insulation (Type B), annex J applies
(IEC/EN 60335-1/A1)

---

The microenvironment is pollution degree 1 under Replaced by IEC/EN 60335-

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 53 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Type A coating

1/A2:2006, See appendix

(IEC/EN 60335-1/A1)

No creepage distance or clearance requirements


under Type B coating
(IEC/EN 60335-1/A1)

Replaced by IEC/EN 603351/A2:2006, See appendix

---

For motor-compressor complies with IEC 603352-34, parts related not checked
(IEC/EN 60335-2-40)

QXAS-D23zX090B

For motor-compressor not complying with IEC


60335-2-34, additions and modifications as
specified
(IEC/EN 60335-2-40)
29.1

N/A

Clearances not less than the values specified in


Table 16, taking into account the rated impulse
voltage for the overvoltage categories of Table 15,
unless
(IEC/EN 60335-1/A1)

for basic insulation and functional insulation, they


comply with the impulse voltage test of clause 14
(IEC/EN 60335-1/A1)

N/A

However, if construction is affected by wear,


distortion, movement of the parts or during
assembly, the clearances for rated impulse
voltages of 1500V and above are increased by
0.5mm and the impulse voltage test is not
applicable
(IEC/EN 60335-1/A1)

N/A

Impulse voltage test not applicable:

29.1.1

Verdict

(IEC/EN 60335-1/A1)

- when the microenvironment is pollution


degree 3
(IEC/EN 60335-1/A1)

N/A

- for basic insulation of class 0 and class 0I


appliances
(IEC/EN 60335-1/A1)

N/A

Appliances are in overvoltage category II

Compliance is checked by inspection and


measurements as specified

Clearances of basic insulation withstand the


overvoltages, taking into account the rated
impulse voltage

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Clearance at the terminals of tubular sheathed


heating elements may be reduced to 1mm if the
microenvironment is pollution degree 1

N/A

Lacquered conductors of windings considered to


be bare conductors (IEC/EN 60335-1/A1)

29.1.2

Clearances of supplementary insulation not less


than those specified for basic insulation in table
16

29.1.3

Clearances of reinforced insulation not less than


those specified for basic insulation in table 16, but
using the next higher step for rated impulse

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 54 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

voltage
29.1.4

29.1.5

29.2

For functional insulation, the values of table 16


are applicable, unless

the appliance complies with clause 19 with the


functional insulation short-circuited

N/A

Lacquered conductors of windings considered to


be bare conductors (IEC/EN 60335-1/A1)

However, clearances at crossover points are not


measured

Clearance between surfaces of PTC heating


elements may be reduced to 1mm

N/A

Lacquered conductors of windings assumed to be


bare conductors, but the clearances specified in
table 16 are reduced by 0.5mm for rated impulse
voltages of at least 1500V

N/A

Appliances having higher working voltage than


rated voltage, the voltage used for determining
clearances from table 16 is the sum of the rated
impulse voltage and the difference between the
peak value of the working voltage and the peak
value of the rated voltage

N/A

If the secondary winding of a step-down


transformer is earthed, or if there is an earthed
screen between the primary and secondary
windings, clearances of basic insulation on the
secondary side not less than those specified in
table 16, but using the next lower step for rated
impulse voltage

N/A

Circuits supplied with a voltage lower than rated


voltage, clearances of functional insulation based
on the working voltage used as the rated voltage
in table 15

Creepage distances not less than those


appropriate for the working voltage, taking into
account the material group and the pollution
degree

Pollution degree 2 applies, unless

precautions taken to protect the insulation;


pollution degree 1

N/A

insulation subjected to conductive pollution;


pollution degree 3

N/A

Compliance is checked by inspection and


measurements as specified
Insulation located in airflow, pollution degree 3
unless
(IEC/EN 60335-2-40)

P
N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 55 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

29.2.1

Requirement Test

Result

Verdict

Insulation enclosed or located so that unlikely to


be exposed to pollution due to normal use
(IEC/EN 60335-2-40)

N/A

Creepage distances of basic insulation not less


than specified in table 17

For pollution degree 1, creepage distance not less


than the minimum specified for the clearance in
table 16, if the clearance has been checked
according to the test of clause 14

N/A

29.2.2

Creepage distances of supplementary insulation


at least as specified for basic insulation in table 17

29.2.3

Creepage distances of reinforced insulation at


least double as specified for basic insulation in
table 17

29.2.4

Creepage distances of functional insulation not


less than specified in table 18

Creepage distances may be reduced if the


appliance complies with clause 19 with the
functional insulation short-circuited
29.3

Supplementary and reinforced insulation having


adequate thickness, or a sufficient number of
layers, to withstand the electrical stresses
(IEC/EN 60335-1/A1)
Compliance checked by:
- measurement, in accordance with 29.3.1, or

29.3.1

29.3.2

29.3.3

N/A

- an electric strength test in accordance with


29.3.2, or

N/A

- an assessment of the thermal quality of the


material combined with an electric strength test, in
accordance with 29.3.3

N/A

Supplementary insulation having a thickness of at


least 1mm
(IEC/EN 60335-1/A1)

Reinforced insulation having a thickness of at


least 2mm
(IEC/EN 60335-1/A1)

Each layer of material withstand the electric


strength test of 16.3 for supplementary insulation
(IEC/EN 60335-1/A1)

N/A

Supplementary insulation consisting of at least 2


layers
(IEC/EN 60335-1/A1)

N/A

Reinforced insulation consisting of at least 3


layers

N/A

The insulation is subjected to the dry heat test Bb


of IEC 60068-2-2, followed by
(IEC/EN 60335-1/A1)

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 56 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

the electric strength of 16.3


(IEC/EN 60335-1/A1)

N/A

If the temperature rise during the tests of Clause


19 does not exceed the value specified in Table 3,
the test of IEC 60068-2-2 is not carried out
(IEC/EN 60335-1/A1)

N/A

30

RESISTANCE TO HEAT AND FIRE

30.1

External parts of non-metallic material,

parts supporting live parts, and

thermoplastic material providing supplementary or


reinforced insulation,

sufficiently resistant to heat

Ball-pressure test according to IEC 60695-10-2

75 C for enclosure
External parts: at 40 C plus the maximum
temperature rise determined during the test of
clause 11, or at 75 C, whichever is the higher;
temperature (C).......................................................:

125C for PCB, terminal block.


Parts supporting live parts: at 40C plus the
maximum temperature rise determined during the
test of clause 11, or at 125C, whichever is the
higher; temperature (C) ..........................................:

Parts of thermoplastic material providing


(See appended table)
supplementary or reinforced insulation, 25C plus
the maximum temperature rise determined during
clause 19, if higher; temperature (C)......................:

N/A

30.2

Relevant parts of non-metallic material adequately Replaced by IEC/EN 60335resistant to ignition and spread of fire
1/A2:2006, See appendix

---

30.2.1

Glow-wire test of IEC 60695-2-11 at 550 C,


unless

Replaced by IEC/EN 603351/A2:2006, See appendix

---

the material is classified at least HB40 according


to IEC 60695-11-10

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Parts for which the glow-wire test cannot be


carried out meet the requirements in ISO9772 for
category HBF material
(IEC/EN 60335-1/A1)

Replaced by IEC/EN 603351/A2:2006, See appendix

---

30.2.2

Not applicable

(IEC/EN 60335-2-40)

N/A

30.2.3

Appliances operated while unattended, tested as


specified in 30.2.3.1 and 30.2.3.2

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Test not applicable to conditions as specified

Replaced by IEC/EN 603351/A2:2006, See appendix

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 57 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

30.2.3.1

Parts of insulating material supporting


connections carrying a current exceeding 0.2A
during normal operation, and

Replaced by IEC/EN 603351/A2:2006, See appendix

---

parts of insulating material within a distance of


3mm,

Replaced by IEC/EN 603351/A2:2006, See appendix

---

having a glow-wire flammability index of at least


850C according to IEC 60695-2-12

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Parts of insulating material supporting currentcarrying connections, and

Replaced by IEC/EN 603351/A2:2006, See appendix

---

parts of insulating material within a distance of


3mm,

Replaced by IEC/EN 603351/A2:2006, See appendix

---

subjected to glow-wire test of IEC 60695-2-11

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Test not carried out on material having a glowReplaced by IEC/EN 60335wire ignition temperature according to IEC 60695- 1/A2:2006, See appendix
2-13 as specified

---

30.2.3.2

Glow-wire test of IEC 60695-2-11, the temperature being:

30.2.4

31

Verdict

-750C, for connections carrying a current


exceeding 0,2A during normal operation

Replaced by IEC/EN 603351/A2:2006, See appendix

---

-650C, for other connections

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Parts that during the test produce a flame


persisting longer than 2 s, tested as specified

Replaced by IEC/EN 603351/A2:2006, See appendix

---

If a flame persists longer than 2 s during the test,


parts above the connection, as specified,
subjected to the needle-flame test of annex E,
unless

Replaced by IEC/EN 603351/A2:2006, See appendix

---

the material is classified as V-0 or V-1 according


to IEC 60695-11-10

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Base material of printed circuit boards subjected


to needle-flame test of annex E

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Test not applicable to conditions as specified

Replaced by IEC/EN 603351/A2:2006, See appendix

---

RESISTANCE TO RUSTING

Relevant ferrous parts adequately protected


against rusting

Salt mist test of IEC 60068-2-52, severity 2


(IEC/EN 60335-2-40)

Before test, coatings are scratched by means of a


harden steel pin as specified
(IEC/EN 60335-2-40)

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 58 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

32

Requirement Test

Result

Five scratches made at least 5mm apart and at


least 5mm from the edges
(IEC/EN 60335-2-40)

Appliance not deteriorated to such an extent that


compliance with cl. 8 and cl. 27 is impaired
(IEC/EN 60335-2-40)

Coating not be broken and not loosened from the


metal surface
(IEC/EN 60335-2-40)

RADIATION, TOXICITY AND SIMILAR HAZARDS

Appliance does not emit harmful radiation

Replaced by IEC/EN 603351/A2:2006, See appendix

--

Appliance does not present a toxic or similar


hazard

Replaced by IEC/EN 603351/A2:2006, See appendix

--

ANNEX A (INFORMATIVE)
ROUTINE TESTS
Description of routine tests to be carried out by
the manufacturer

3.1.9

Verdict

Not
checked

ANNEX B (NORMATIVE)
APPLIANCES POWERED BY RECHARGEABLE BATTERIES

The following modifications to this standard are


applicable for appliances powered by batteries
that are recharged in the appliance

N/A

This annex does not apply to battery chargers

N/A

Appliance operated under the following conditions:

-the appliance, supplied by its fully charged


battery, operated as specified in relevant part 2

N/A

-the battery is charged, the battery being initially


discharged to such an extent that the appliance
cannot operate

N/A

-if possible, the appliance is supplied from the


supply mains through its battery charger, the
battery being initially discharged to such an extent
that the appliance cannot operate. The appliance
is operated as specified in relevant part 2

N/A

If the appliance incorporates inductive coupling


between two parts that are detachable from each
other, the appliance is supplied from the supply
mains with the detachable part removed

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 59 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

3.6.2

Part to be removed in order to discard the battery


is not considered to be detachable

N/A

5.101

Appliances supplied from the supply mains tested


as specified for motor-operated appliances

N/A

7.1

Battery compartment for batteries intended to be


replaced by the user, marked with battery voltage
and polarity of the terminals

N/A

7.12

The instructions for appliances incorporating


batteries intended to be replaced by the user
includes required information

N/A

Details about how to remove batteries containing


materials hazardous to the environment given

N/A

7.15

Markings placed on the part of the appliance


connected to the supply mains

N/A

8.2

Appliances having batteries that according to the


instruction may be replaced by the user need only
have basic insulation between live parts and the
inner surface of the battery compartment

N/A

If the appliance can be operated without batteries,


double or reinforced insulation required

N/A

11.7

The battery is charged for the period described

N/A

19.1

Appliances subjected to tests of 19.101, 19.102


and 19.103

N/A

19.101

Appliances supplied at rated voltage for 168 h, the


battery being continually charged

N/A

19.102

Short-circuiting of the terminals of the battery,


being fully charged, for appliances having
batteries that can be removed without the aid of a
tool

N/A

19.103

Appliances having batteries replaceable by the


user supplied at rated voltage under normal
operation with the battery removed or in any
position allowed by the construction

N/A

21.101

Appliances having pins for insertion into socketoutlets have adequate mechanical strength,
checked according to procedure 2 of IEC 68-2-32

N/A

Part of the appliance incorporating the pins subjected to the free fall test, procedure
2, of IEC 60068-2-32, the number of falls being:

- 100, the mass of part does not exceed 250 g

N/A

- 50, the mass of part exceeds 250 g

N/A

After the test, the requirements of 8.1, 15.1.1,


16.3 and clause 29 are met

N/A

Appliances having pins for insertion into socketoutlets tested as fully assembled as possible

N/A

22.3

Result

Verdict

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 60 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

25.13

An additional lining or bushing not required for


interconnection cords operating at safety extralow voltage

N/A

30.2

For parts of the appliance connected to the supply


mains during the charging period, 30.2.3 applies

N/A

For other parts, 30.2.2 applies

N/A

ANNEX C (NORMATIVE)
AGEING TEST ON MOTORS

Tests, as described, carried out when doubt with


regard to the temperature classification of the
insulation of a motor winding

N/A

Result

ANNEX D (NORMATIVE)
THERMAL MOTOR PROTECTORS

Verdict

N/A

ANNEX E (NORMATIVE)
NEEDLE-FLAME TEST

Needle-flame test carried out in accordance with IEC 60695-2-2, with the following
modifications:

Severities

The duration of application of the test flame is


30 s 1 s

Replaced by IEC/EN 603351/A2:2006, See appendix

---

Test procedure

8.2

The specimen so arranged that the flame can be


applied to a vertical or horizontal edge as shown
in the examples of figure 1

Replaced by IEC/EN 603351/A2:2006, See appendix

---

8.4

The first paragraph does not apply

Replaced by IEC/EN 603351/A2:2006, See appendix

---

If possible, the flame is applied at least 10 mm


from a corner

Replaced by IEC/EN 603351/A2:2006, See appendix

---

The test is carried out on one specimen

Replaced by IEC/EN 603351/A2:2006, See appendix

---

If the specimen does not withstand the test, the


test may be repeated on two further specimens,
both withstanding the test

Replaced by IEC/EN 603351/A2:2006, See appendix

---

8.5

10

Evaluation of test results


The duration of burning not exceeding 30 s

Replaced by IEC/EN 603351/A2:2006, See appendix

---

However, for printed circuit boards, the duration of Replaced by IEC/EN 60335burning not exceeding 15 s
1/A2:2006, See appendix

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 61 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

ANNEX F (NORMATIVE)
CAPACITORS

Capacitors likely to be permanently subjected to the supply voltage, and used for
radio interference suppression or voltage dividing, comply with the following
clauses of IEC 60384-14, with the following modifications:

1.5

Terminology

1.5.3

Class X capacitors tested according to subclass


X2

N/A

1.5.4

This subclause is applicable

N/A

1.6

Marking

Items a) and b) are applicable

N/A

3.4

Approval testing

3.4.3.2

Table II is applicable as described

N/A

4.1

Visual examination and check of dimensions

This subclause is applicable

N/A

4.2

Electrical tests

4.2.1

This subclause is applicable

N/A

4.2.5

This subclause is applicable

N/A

4.2.5.2

Only table IX is applicable

N/A

Values for test A apply

N/A

However, for capacitors in heating appliances the


values for test B or C apply

N/A

Damp heat, steady state

This subclause is applicable

N/A

Only insulation resistance and voltage proof are


checked

N/A

Impulse voltage

This subclause is applicable

N/A

Endurance

Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7


applicable

N/A

Only insulation resistance and voltage proof are


checked

N/A

Visual examination, no visible damage

N/A

Passive flammability test

4.12

4.13

4.14

4.14.7

4.17

Result

Verdict

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 62 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

This subclause is applicable

N/A

Active flammability test

This subclause is applicable

N/A

ANNEX G (NORMATIVE)
SAFETY ISOLATING TRANSFORMERS

The following modifications to this standard are applicable for safety isolating
transformers:

Marking and instructions

7.1

Transformers for specific use marked with:

-name, trademark or identification mark of the


manufacturer or responsible vendor

N/A

-model or type reference

N/A

Overload protection of transformers and associated circuits

Fail-safe transformers comply with subclause


15.5 of IEC 61558-1

N/A

Construction

Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 are


applicable

N/A

Clearances, creepage distances and solid insulation

4.18

17

22

29

29.1, 29.2 and The distances specified in items 2a, 2c and 3 in


29.3
table 13 of IEC 61558-1 apply

N/A

ANNEX H (NORMATIVE)
SWITCHES

Switches comply with the following clauses of IEC 61058-1, as modified:

-The tests of IEC 61058-1 carried out under the


conditions occurring in the appliance

N/A

-Before being tested, switches are operated 20


times without load

N/A

Marking and documentation

Switches are not required to be marked

N/A

However, switches that can be tested separately


from the appliance marked with the
manufacturers name or trade mark and the type
reference

N/A

Mechanism

13

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 63 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

The tests may be carried out on a separate


sample

N/A

15

Insulation resistance and dielectric strength

15.1

Not applicable

N/A

15.2

Not applicable

N/A

15.3

Applicable for full disconnection and microdisconnection

N/A

17

Endurance

Compliance is checked on three separate


appliances or switches

N/A

For 17.2.4.4, the number of cycles is 10 000,


unless otherwise specified in 24.1.3 of the
relevant part 2 of IEC 60335

N/A

Switches for operation under no load and which


can be operated only by a tool and switches
operated by hand that are interlocked so that they
cannot be operated under load, are not subjected
to the tests

N/A

Subclause 17.2.2 and 17.2.5.2 are not applicable

N/A

The ambient temperature during the test is that


occurring in the appliance during the test of
Clause 11 in IEC 60335-1

N/A

Temperature rise of the terminals not more than


30 K above the temperature rise measured in
clause 11 of IEC 60335-1

N/A

Clearances, creepage distances, solid insulation and coatings of rigid printed board
assemblies

This clause is applicable to clearances and


creepage distances for functional insulation,
across full disconnection and microdisconnection, as stated in table 24

N/A

20

6.6

ANNEX I (NORMATIVE)
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE
RATED VOLTAGE OF THE APPLIANCE

N/A

ANNEX J (NORMATIVE)
COATED PRINTED CIRCUIT BOARDS

Testing of protective coatings of printed circuit boards carried out in accordance


with IEC 60664-3 with the following modifications:

Climatic sequence

When production samples are used, three

Replaced by IEC/EN 60335-

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 64 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

6.6.1

Requirement Test

Result

samples of the printed circuit board are tested

1/A2:2006, See appendix

Cold

The test is carried out at -25C


6.6.3

Replaced by IEC/EN 603351/A2:2006, See appendix

Replaced by IEC/EN 603351/A2:2006, See appendix

--

Replaced by IEC/EN 603351/A2:2006, See appendix

ANNEX K (NORMATIVE)
OVERVOLTAGE CATEGORIES

---

The information on overvoltage categories is


extracted from IEC 60664-1

Overvoltage category is a numeral defining a


transient overvoltage condition

Equipment of overvoltage category IV is for use at


the origin of the installation

N/A

Equipment of overvoltage category III is


equipment in fixed installations and for cases
where the reliability and the availability of the
equipment is subject to special requirements

N/A

Equipment of overvoltage category II is energy


consuming equipment to be supplied from the
fixed installation

--

Additional tests
This sub-clause is not applicable

--

Partial discharge extinction voltage


Type A coatings not subjected to a partial
discharge test

6.9

Replaced by IEC/EN 603351/A2:2006, See appendix

Rapid change of temperature


Severity 1 is specified

6.8.6

Verdict

If such equipment is subjected to special


requirements with regard to reliability and
availability, overvoltage category III applies

N/A

Equipment of overvoltage category I is equipment


for connection to circuits in which measures are
taken to limit transient overvoltages to an
appropriate low level

N/A

ANNEX L (INFORMATIVE)
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES

Sequences for the determination of clearances


and creepage distances

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 65 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

ANNEX M (NORMATIVE)
POLLUTION DEGREE

Result

The information on pollution degrees is extracted


from IEC 60664-1
Pollution

Verdict

The microenvironment determines the effect of


pollution on the insulation, taking into account the
microenvironment

Means may be provided to reduce pollution at the


insulation by effective enclosures or similar

Minimum clearances specified where pollution


may be present in the microenvironment

Degrees of pollution in the microenvironment

For evaluating creepage distances, the following degrees of pollution in the


microenvironment are established:

- pollution degree 1: no pollution or only dry, nonconductive pollution occurs. The pollution has no
influence

N/A

- pollution degree 2: only non-conductive pollution


occurs, except that occasionally a temporary
conductivity caused by condensation is to be
expected

- pollution degree 3: conductive pollution occurs or


dry non-conductive pollution occurs that becomes
conductive due to condensation that is to be
expected

N/A

- pollution degree 4: the pollution generates


persistent conductivity caused by conductive dust
or by rain or snow

N/A

ANNEX N (NORMATIVE)
PROOF TRACKING TEST

The proof tracking test is carried out in accordance with IEC 60112 with the
following modifications:

Test apparatus

7.3

Test solutions

Test solution A is used

N/A

10

Determination of proof tracking index (PTI)

10.1

Procedure

Proof voltage is 100V, 175V, 400V or 600V ............:

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 66 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

10.2

Requirement Test

Result

Last paragraph of clause 3 applies

N/A

The test is carried out on five specimens

N/A

In case of doubt, additional test with proof voltage


reduced by 25V, the number of drops increased
to 100

N/A

Report

The report stating if the PTI value was based on a


test using 100 drops with a test voltage of (PTI25) V

N/A

ANNEX O (INFORMATIVE)
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30

Description of tests for determination of


resistance to heat and fire

Verdict

ANNEX P (INFORMATIVE)
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES

Modifications applicable for class 0 and 0I appliances having a rated voltage


exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE

Modifications may also be applied to class I appliances having a rated voltage


exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE, if liable to be connected to a supply mains that
excludes the protective earthing conductor

General conditions for the tests

5.7

The ambient temperature for the tests of Clauses

N/A

11 and 13 is

+3
40 0 C

Marking and instructions

7.1

The appliance marked with the letters WDaE

N/A

7.12

The instructions state that the appliance is to be


supplied through a RCD having a rated residual
operating current not exceeding 30mA

N/A

The instructions state that the appliance is


considered to be suitable for use in countries
having a warm damp equable climate, but may
also be used in other countries

N/A

11

Heating

11.8

The values of Table 3 are reduced by 15K

N/A

13

Leakage current and electric strength at operating temperature

13.2

The leakage current for class I appliances not

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 67 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

exceeding 0.5mA
15

Moisture resistance

15.3

The value of t is 37C

N/A

16

Leakage current and electric strength

16.2

The leakage current for class I appliances not


exceeding 0.5mA

N/A

19

Abnormal operation

19.13

The leakage current test of 16.2 is applied in


addition to the electric strength test of 16.3

N/A

ANNEX Q (INFORMATIVE)
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS

Description of tests for appliances incorporating electronics circuits

ANNEX R (NORMATIVE)
SOFTWARE EVALUATION

Software evaluated in accordance with the following clauses of Annex H of IEC


60730-1, as modified:

Definitions

N/A

Only definitions H.2.16 to H.2.20 applicable

N/A

Information

N/A

Only footnotes 12) to 18) of Table 7.2, as


modified, applicable

N/A

Controls using software

N/A

All the subclauses of H.11.12, as modified, except


H.11.12.6 and H.11.12.6.1, applicable

N/A

H.11.12.7

Delete text

N/A

H.11.12.7.1

For appliances using software class C having a


single channel with self-test and monitoring
structure, the manufacturer provides the
measures necessary to address the fault/errors in
safety related segments and data

N/A

H.11.12.8

Software fault/error detection occurs before


compliance with 19.13 of IEC 60335-1 is impaired

N/A

H.12.8.1

Replace text

N/A

H.12.13

Software and safety related hardware under its


control initializes and terminates before
compliance with 19.13 of IEC 60335-1 is impaired

N/A

H.2

H.7

H.11.12

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 68 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

AA

ANNEX AA (INFORMATIVE)
Examples for operating temperatures of the appliance

BB

ANNEX BB (NORMATIVE)
Selected information about refrigerants

CC

ANNEX CC (INFORMATIVE)
Transportation, marking and storage for units that employ flammable
refrigerants

CC.1

Transport of equipment containing flammable


refrigerants

N/A

CC.2

Marking of equipment using signs

N/A

CC.3

Disposal of equipment using flammable


refrigerants

N/A

CC.4

Storage of equipment/appliances

N/A

CC.5

Storage of packed (unsold) equipment

N/A

DD

ANNEX DD (NORMATIVE)
Service operations

DD.1

Generals

N/A

DD.2

Symbols

N/A

DD.3

Information in manual

N/A

DD.4

Information on servicing

N/A

DD.5

Repairs to sealed components

N/A

DD.6

Repair to intrinsically safe components

N/A

DD.7

Cabling

N/A

DD.8

Detection of flammable refrigerants

N/A

DD.9

Leak detection methods

N/A

DD.10

Removal and evacuation

N/A

DD.11

Charging procedures

N/A

DD.12

Decommissioning

N/A

DD.13

Labelling

N/A

DD.14

Recovery

N/A

EE

ANNEX EE (NORMATIVE)
Pressure Tests

EE.1

General

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 69 of 139

Report. No.: GZ12100571-1R3

IEC / EN 60335-2-40
Clause

Requirement Test

Result

Verdict

EE.2

Pressure test value determined under testing


carried out in Clause 11

EE.3

Pressure test value determined under testing


carried out in Clause 19.

Measure pressure:
Indoor unit: 3,2MPa;
Outdoor unit: 3,2MPa
Measure pressure:
Indoor unit: 3,8MPa;
Outdoor unit: 4,2MPa
Tested pressure:
Indoor unit: 11,4MPa;
Outdoor unit: 12,6MPa

EE.4

Pressure test value determined under testing


carried out under standstill conditions

N/A

EE.5

Fatigue test option for Clauses EE.1 and EE.4.1

N/A

FF

ANNEX FF (NORMATIVE)
Leak simulation tests

FF.1

General

N/A

FF.2

Test methods

N/A

GG

ANNEX GG (NORMATIVE)
Charge limits, ventilation requirements and requirements for secondary
circuits

GG.1

Requirements for charge limits in ventilated


areas

N/A

GG.2

Requirements for charge limits in unventilated


areas

N/A

GG.3

Requirements for charge limits in areas with


mechanical ventilation

N/A

GG.4

Requirements for mechanical ventilation within


the appliance enclosure

N/A

GG.5

Requirements for mechanical ventilation for


rooms complying with ISO 5149

N/A

GG.6

Requirements for refrigeration systems


employing secondary heat exchangers

N/A

GG.7

The appliance shall then be tested with a


maximum water flow under the conditions
described in g).

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 70 of 139

Report. No.: GZ12100571-1R3

APPENDIX 1:
To complete the assessment according to EN 60335-1
the following requirements are considered as well :
th

GROUP DIFFERENCES to IEC 60335-1, 4 ed (CB Bulletin 109B)


Clause

Requirement Test

Result

Verdict

6.1

Protection against electric shock: Class 0, 0I


(IEC 60335-1), I, II, III

Class I

7.1

Rated voltage or voltage range shall cover


-230 V for single-phase appliances
-400 V for multi-phase appliances

25.6

Supply cords of single-phase portable


appliances having a rated current not
exceeding 16 A shall be provided with a plug
complying with the following standard sheets
of IEC 60083 : 1975:

25.6

-for Class I appliances


(standard sheet C2b, C3b or C4)

...

N/A

25.6

-for Class II appliances


(standard sheet C5 or C6)

...

N/A

25.7

Add -ordinary polychloroprene sheathed


flexible cord (code designation
60245 IEC 57) ( H05RN-F)

P
P

N/A

When supply cords having high flexibility are


used, they shall not be lighter than :

- rubber insulated and sheathed cord (code


designation 60245 IEC 86) (H03RR-H);

N/A

- rubber insulated, crosslinked PVC sheathed


cord (code designation 60245 IEC 87)
(H03RV4-H);

N/A

- crosslinked PVC insulated and sheathed


cord (code designation 60245 IEC 88)
(H03V4V4-H).

N/A

NOTE Z1 The harmonized code designations


corresponding to the IEC cord types are
given in Annex ZD.

N/A

ANNEX ZC
(normative)

Normative references to international


publications with their corresponding
European publications

N/A

ANNEX ZD
(informative)

IEC and CENELEC code designations for


flexible cords

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 71 of 139

Report. No.: GZ12100571-1R3

Clause

Requirement Test

Result

Verdict

ZA

ANNEX ZA, SPECIAL NATIONAL CONDITIONS

7.12

DENMARK: requirements regarding marking


tag of power supply cord and connecting of
earthing wire

Not
checked

19.5

NORWAY: the test is also applicable to


appliances intended to be permanently
connected to fixed wiring

Not
checked

22.2

FRANCE, NORWAY: The second paragraph


of this subclause dealing with single-phase
Class I permanently connected appliances
with heating elements is not applicable due to
the supply system

Not
checked

25.6

BELGIUM, FRANCE, SPAIN , UNITED


KINGDOM: plugs according to Standard
Sheet C2b not allowed

Not
checked

AUSTRIA, FINLAND, GERMANY, ICELAND,


IRELAND, ITALY, LUXEMBOURG,
NETHERLANDS, NORWAY, PORTUGAL,
SPAIN, SWEDEN, SWITZERLAND, UNITED
KINGDOM: plugs according to Standard C3b
not allowed

Not
checked

DENMARK: Supply cords of single-phase


portable appliances having a rated current not
exceeding 13 A provided with a plug according
to the following:

(EN 60335-1:2002)

- Class I appliances: Section 107-2-D1


Standard Sheet DK2-1a

Not
checked

For appliances covered by a Part 2 of


EN 60 335, also plugs in accordance with
Section 107-2-D1 Standard Sheet C2b, C3b or
C4 are allowed

Not
checked

- Class II appliances: Section 107-2-D1,


Standard Sheet C1b ,C5, C6, DKA2-1a and
DKA2-1b

Not
checked

Stationary single-phase appliances, having a


rated current not exceeding 13 A, and
provided with a plug, the plug is in accordance
with the requirements above

Not
checked

Multi-phase appliances and single-phase


appliances having a rated current exceeding
13 A, and provided with a plug, the plug is in
accordance with the requirements below:

- Class I appliances: Section 107-2-D1,


Standard Sheet DK6-1a/EN 60 309-2,
Standard Sheet 2-II, 2-IV

Not
checked

- Class II appliances: Section 107-2-D1,


Standard Sheet DK6-1a*/2-II, 2-IV*

Not
checked

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 72 of 139
Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

For max. allowed current values see EN


60335-1

Not
checked

IRELAND: plug is in accordance with Standard


Sheets B2 and C2b (see annex ZB as well)

Not
checked

ITALY: Only plugs listed in CENELEC Report


ROBT-005:2001 are allowed

Not
checked

SPAIN: For household appliances the


following plugs only are allowed:

- UNE 20315:ESC 10-1b, C2b, C4, C6, or


ESB 25-5b;

Not
checked

- UNE-EN 50075

Not
checked

SWITZERLAND: supply cords of portable


household and similar electrical appliances,
rated current not exceeding 10 A, provided
with a plug complying with SEV 1011 or IEC
60884-1 and one of the following dimension
sheets:

SEV 6532-2:1991
plug type 15 3P+N+PE 250/400 V, 10 A

Not
checked

SEV 6533-2:1991
plug type 11 L+N 250 V, 10 A

Not
checked

SEV 6534-2:1991
plug type 12 L+N+PE 250 V, 10 A

Not
checked

UNITED KINGDOM: plug according to


Standard Sheet B2 or C5 used (refer to Annex
ZB)

Not
checked

25.8

IRELAND, UNITED KINGDOM: replacement


of figures (rated current/cross-sectional area)
in the table

Not
checked

ZB

ANNEX ZB, A-DEVIATIONS

SWITZERLAND: information about batteries

7.1

ITALY: the voltage is 220 V/380 V

(EN 60335-1:2002)

Not
checked
Not
checked
Not
checked

SPAIN: the voltages are 127 V/220 V and 220


V/380 V
25.6

IRELAND / UNITED KINGDOM: regulations


concerning plugs to be fitted to domestic
appliances

ZAA

ANNEX ZAA (informative)

Not
checked

(EN 60335-2-40/A11:2004)

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 73 of 139
Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

Refrigerating systems having a pressure


greater than 0,05 MPa are considered to be
assemblies falling within the scope of the
Pressure Equipment Directive, 97/23/EC.
However, according to Article 1, item 3.6 of
the directive, equipment classified no higher
than category I and covered by the low voltage
directive is excluded from its scope.

N/A

According to guideline 1/39 of the directive,


this exclusion applies to both components and
assemblies (refrigerant circuits). This applies
to appliances containing vessels (e.g.
compressors, receivers) or piping with limits in
accordance with the following:

N/A

vessels

---

dangerous refrigerants (Annex II, Table 1):

---

volume not exceeding 1 l, or

N/A

pressure x volume not exceeding 5 MPa l.

N/A

non-dangerous refrigerants (Annex II, Table 2):


volume not exceeding 1 l, or

--N/A

pressure x volume not exceeding 20 MPa l.

Piping

---

dangerous refrigerants (Annex II, Table 6):

---

numerical designation not exceeding 25, or

N/A

pressure not exceeding 1 MPa and


numerical designation not exceeding 100,
or

N/A

pressure exceeding 1 MPa and pressure x


numerical designation not exceeding
100 MPa.

N/A

non-dangerous refrigerants (Annex II, Table 7):

---

numerical designation not exceeding


100, or

---

pressure x numerical designation not


exceeding 350 MPa.

For other components, the most onerous limit


of the two applies.

N/A

The volume is the internal volume of the


vessel and includes the volume of pipework
up to the first connection. It excludes the
volume of fixed internal parts.

N/A

ANNEX EMF
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 74 of 139
Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

The Tested product also complies to the requirements of EN 62233:2008

Limit 100%

Max.: 1,735%

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 75 of 139

Report. No.: GZ12100571-1R3

TABLES:
10.1

TABLE: Power input deviation

Input deviation of/at:

P rated (W)

P measured
(W)

dP

Required dP

Remark

GWH24RD-K3DNA3C / at
230V~, 50Hz

3050

2214,9

-27,4%

+15%

Cooling mode

2700

2074,6

-23,2%

+15%

Heating mode

GWH24RD-K3DNA8C / at
230V~, 50Hz

4000

3986,0

-0,4%

+15%

Heating mode

10.2

TABLE: Current deviation

Current deviation of/at:

11.8

I rated (A)

N/A
I measured (A)

dI

Required dI

Remark

TABLE: Heating test, thermocouples

Test voltage (V) .......................................................


240x1,06=254,4V

Cooling mode: 32/23(IU); 43/26(OU)


Ambient, t1 (C) ........................................................
Heating mode: 27/--(IU); 24/18(OU)

Same as above
Ambient, t2 (C) ........................................................
T (C)

Thermocouple locations

Max. T (C)

cooling

heating

Supply cord

44,4

36,6

75

Relay ambient

35,7

30,9

T70

PCB

36,2

32,0

145

X capacitor

36,6

37,4

T100

Varistor

36,2

31,2

T85

High frequency transformer

43,9

39,6

Class E: 105

Inductance

45,7

48,4

Class E: 105

Terminal block

33,9

28,6

85

Fan motor enclosure

86,0

65,2

For reference

Capacitor of fan motor

36,8

31,5

T70

Step motor

40,8

38,1

For reference

Enclosure of indoor unit

32,1

25,8

85

Fan motor enclosure

60,7

30,7

For reference

Compressor enclosure (Top)

80,3

73,3

For reference

Compressor enclosure (side)

51,4

31,5

For reference

Indoor unit:

Outdoor unit:

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 76 of 139

Report. No.: GZ12100571-1R3

Discharge pipe of compressor

81,4

74,5

For reference

Suction pipe of compressor

13,9

20,4

For reference

4-way valve

51,3

78,9

For reference

Terminal block

54,3

37,9

85

Compressor lead wire

56,8

45,7

T105

Interconnection cord

40,7

36,9

75

Reactor

74,0

35,9

Class H: 165

PCB

52,7

35,7

145

X capacitor

38,8

33,6

T100

Relay ambient

37,0

31,5

T70

High frequency transformer

52,9

37,9

Class E: 105

Test corner

44,9

20,5

90

11.8

TABLE: Heating test, resistance method

Test voltage (V)........................................................: 240x1,06=254,4V

Ambient, t1 (C)......................................................... : 25

Ambient, t2 (C)......................................................... : Cooling mode:


32/23(IU); 43/26(OU)
Heating mode:
27/--(IU); 24/18(OU)

Temperature of winding

T1
(C)

R1 ()

R2 ()

Main winding of indoor fan


motor FN25A-PG (Kaibang)

25

194,0

248,9

234,5

98,4

79,2

115

Aux. winding of indoor fan


motor FN25A-PG (Kaibang)

25

188,8

237,9

224,3

92,5

73,8

115

Cooling

T (C)

Heating Cooling Heating

Max. T Insulation
class
(C)

25
1970
-2403
-82,0
120
B
4 ways valve
Remark:
1. The resistance method for 4 ways valve only conducted under heating operation mode because it
only operated at this mode.
2. The outdoor fan motor LW92K-ZL is DC type motor which is difficult to conduct resistance method.
13.2

TABLE: Leakage current


Heating appliances: 1.15 x rated input.................. :

N/A

Motor-operated and combined appliances:


1.06 x rated voltage ............................................... :

240x1,06=254,4V

Leakage current between


Live parts and accessible earthed metal part
Live parts and plastic enclosure
13.3

I (mA)

Max. allowed I (mA)

L: 0,33; N: 0,34

3,5

L: 0,024; N: 0,023

0,25

TABLE: Electric strength

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 77 of 139
Test voltage applied between:

Report. No.: GZ12100571-1R3


Voltage (V)
Breakdown
(Yes/No)

Live parts and accessible earthed metal part

1000

No

Internal wire sheath and plastic enclosure

1750

No

Live parts and plastic enclosure

3000

No

14

TABLE: Transient overvoltages

Clearance between:

16.2

Cl (mm)

N/A
Required
Cl (mm)

Rated impulse
voltage (V)

Impulse test
voltage (V)

Flashover
(Yes/No)

TABLE: Leakage current

Single phase appliances: 1.06 x rated voltage ..... :

240x1,06=254,4V

Three phase appliances 1.06 x rated voltage


divided by 3:......................................................... :

N/A

Leakage current between

I (mA)

Max. allowed I (mA)

Live parts and accessible earthed meal part

Max.: 0,82

3,5

Live parts and plastic enclosure

Max.: 0,054

0,25

16.3

TABLE: Electric strength

Test voltage applied between:

Voltage (V)

Breakdown
(Yes/No)

Live parts and accessible earthed meal part

1250

No

Internal wire sheath and plastic enclosure

1750

No

Live parts and plastic enclosure

3000

No

17

TABLE: Overload protection,

N/A

Temperature of part/at:

19.2

dT (C)

Max. dT (C)

TABLE: Lock motor test, temperature measurements.

Test voltage: supplied by the main controller


Ambient temperature: 25 C
Duration: 15 days endurance test, after 3 days high-voltage test performed.
Insulation
class

Enclosure
temperature(C)

Winding
temperature
(C)

HV test performed
with 1250V

Leakage
current
(mA)

FN25A-PG (Kaibang)

103,1

114,5

Pass

0,052

LW92K-ZL (Kaibang)

86,4

127,0

Pass

0,051

Measured sample

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 78 of 139
Report. No.: GZ12100571-1R3
Remark:
The temperature limited for enclosure is 150C, for Class E is 165C, and the Leakage current is 2 mA.
19.14

TABLE: Abnormal operation

t1 (C) ........................................................................ : ---

t2 (C) ........................................................................ : ---

Temperature T of part / at :

T (C)

Required T (C)

Test corner

47,1

175

Supply cord

37,1

175

Test corner

Maximum: 44,8

175

Supply cord

Maximum: 45,9

175

Test corner

Maximum: 53,7

175

Supply cord

Maximum: 50,7

175

Test corner

Maximum: 44,1

175

Supply cord

Maximum: 47,8

175

19.4

19.5

19.7

19.10

24.1

TABLE: Components

Object / part
No.

Manufacturer/
trademark

P
Type / model

Technical data

Standard

Mark(s) of
conformity

A1: GWH24RD-K3DNA2C, GWH24RD-K3DNA3C;


A2: GWH24RD-K3DNA6C;
A3: GWH24RD-K3DNA8C, GWH24RD-K3DBA5E, GWH24RD-K3DBE1E, GWH24RD-K3DNA5C,
GWH24RD-K3DBA3E
Indoor unit:
Supply lead

Guangdong Huasheng H05VV-F


Electrical Appliances
Co., Ltd.

3G2,5 mm

DIN VDE 0281-5 VDE


40005362

Alternative

Changzhou
Hongchang
Electronics Co., Ltd.

H05VV-F

3G2,5 mm

DIN VDE 0281-5 VDE


124978

Alternative

Various

H05VV-F

3G2,5 mm

DIN VDE 0281-5 S or other


EU
certification
marks

Interconnecti Guangdong Huasheng H07RN-F


on cord for
Electrical Appliances
A1, A2
Co., Ltd.

4G2,5 mm

DIN VDE 0282-4 VDE


40016788

Alternative

4G2,5 mm

DIN VDE 0282-4 VDE


40016464

Eastwire Industrial
Limited

H07RN-F

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Alternative

Page 79 of 139
H07RN-F
4G2,5 mm

Various

Report. No.: GZ12100571-1R3


DIN VDE 0282-4 S or other
EU
certification
marks

Interconnecti Guangdong Huasheng S05RN-F


on cord only Electrical Appliances
for A3
Co., Ltd.

4G0,75 mm

DIN VDE 0282-4 VDE


40015785

Alternative

4G0,75 mm

DIN VDE 0282-4 S or other


EU
certification
marks

Interconnecti Guangdong Huasheng H07RN-F


on cord for
Electrical Appliances
A3
Co., Ltd.

3G2,5 mm

DIN VDE 0282-4 VDE


40016788

Alternative

Eastwire Industrial
Limited

H07RN-F

3G2,5 mm

DIN VDE 0282-4 VDE


40016464

Alternative

Various

H07RN-F

3G2,5 mm

DIN VDE 0282-4 S or other


EU
certification
marks

Step Motor

Jiangsu Huayang
Electrical Appliance
Co.; Ltd

MP35XX

12VDC;Class A;
1308%

EN 60335-2-40

Tested with
appliance

Alternative

Changzhou Oukai
Electrical Appliance
Co.; Ltd

MP35XX

12VDC;Class A;
1308%

EN 60335-2-40

Tested with
appliance

Indoor fan
motor

Zhuhai Kaibang Motor FN25A-PG


Manufacturing Co.,
Ltd.

220-240V~; 50Hz; EN 60335-2-40


35W; 0,31A; Class
E; Main:1948%;
Aux:188,88%

Tested with
appliance

-Fan Motor
Protector

Jiangsu Changsheng BR-B5D


Electric Appliance Co.
Ltd.

250V; 5A;
Operation:100C

EN 60730-1

VDE
40015984

-Alternative

Changzhou
KW Series
Changhong Tongli
Electric Appliance Co.
Ltd.

250V; 8A;
Operation:100C

EN 60730-1

Sensata Technologies BRL Series


Holland; B.V.

250V; 8A;
Operation:100C

EN 60730-1

-Fan motor
capacitor

Wuxi Xixi Capacitor


Co.; Ltd.

CBB61-1

2,5uF; 450V; T70

EN 60252-1

TV
Rheinland
R50128479

-Alternative

Zhuhai Gree Xinyuan


Electronic Co., Ltd.

CBB61

2,5uF; 500VAC;
T70

EN 60252-1

TV
Rheinland
R50120798

-Alternative

Xiamen Faratronic
Co., Ltd.

CBB61

2,5uF; 450VAC;
T70

EN 60252-1

VDE
40004094

-Alternative

NINGBO SHINE
ELECTRICAL CO.
LTD.

CBB61A

2,5uF; 450VAC;
T70

EN 60252-1

TV
Rheinland
R50065558

-Alternative

Various

S05RN-F

EN 60730-2-2

EN 60730-2-2

EN 60730-2-2

VDE
40020906

KEMA
2089558.01

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 80 of 139
MKNS255
2,5uF; 450VAC;
T70

Report. No.: GZ12100571-1R3


EN 60252-1
TV
Rheinland
R50035566

CBB61

2,5uF; 450VAC;
T70

EN 60252-1

VDE
40006835

Cold plasma Shandong Xuesheng


generator
Technology Co.; Ltd.

XS-PL-06

220-240VAC;
50/60Hz; 2W

EN 60335-1; EN
60335-2-65

TV
Rheinland
R50172899

Main board
only for A1

GREE

M846F2TJ

--

EN 60335-2-40

Tested with
appliance

Main board
only for A2

GREE

M846F2TAJ

--

EN 60335-2-40

Tested with
appliance

Main board
only for A3

GREE

M846F2UEJ

--

EN 60335-2-40

Tested with
appliance

-X Capacitor Xiamen Faratronic


1#
Co., Ltd.

MKP62

275VAC; 104M;
T110

EN 132400;

VDE
40000358

-Alternative

Anhui Xinyang
Electronics Co., Ltd.

MKP

0,1F; AC275V;
T100

IEC 60384-14;

OKAYA Electric
Industries Co., Ltd.

LE104

275VAC; 0,1F;
T100

IEC 60384-14;

Various

Various

0,1F; AC275V;
T100 or above

IEC 60384-14;

275VAC; 224K;
T110; X2

EN 132400;

275VAC; 0,22F;
T100

IEC 60384-14;

0,22F; AC275V;
X2; T100 or above

IEC 60384-14;

-Alternative

Shanghai Haoye
Capacitors Co., Ltd.

-Alternative

Foshan Shunde
Fongming Electronic
Tech. Co., Ltd.

-Alternative

-Alternative

-X Capacitor Xiamen Faratronic


2#
Co., Ltd.

MKP62

-Alternative

OKAYA Electric
Industries Co., Ltd.

LE224

Various

Various

-Alternative

IEC 60384-14

EN 132400

EN 132400

EN 132400

IEC 60384-14

EN 132400

EN 132400

VDE
40024537
SEMKO
SE/0142-1D
S or other
EU
certification
marks
VDE
40000358
SEMKO
SE/0142-1D
S or other
EU
certification
marks

-Y capacitor

TDK-EPC
Corporation,
Capacitors Group

CS103M

250VAC; 103M; Y2 IEC 60384-14;


EN132400

VDE
40029781

-Alternative

Various

Various

250VAC; 103M; Y2 IEC 60384-14;


EN 132400

S or other
EU
certification
marks

-Y capacitor
for A3

Murata Mfg. Co., Ltd.

KX472M

250VAC; 472M

IEC 60384-14
EN 60384-14

VDE
40002831

-Alternative

Various

Various

250VAC; 472M

IEC 60384-14
EN 60384-14

S or other
EU
certification
marks

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 81 of 139
-Varistor

Chengdu Tieda
Electronic Co., Ltd.

MYN15-621K

385VAC; T85

Report. No.: GZ12100571-1R3


CECC 42000;
CECC 42200;

VDE
40008571

CECC 42201
-Alternative

Xianhua Advanced
FNR-14K621
Sensitive Components
Co., Ltd.

380VAC; T85

CECC 42000;
CECC 42200;

VDE
40008242

-Optocoupler

Sharp Corporation

PC817

Vceo:80V; If:50mA; EN 60747-5-2


Ic:50mA

VDE
40008087

-Alternative

Sharp Corporation

PC851

Vceo:350V;
If:50mA; Ic:50mA

EN 60747-5-2

VDE
40008087

-PCB
material

DOOSAN
CORPORATION
ELECTROMATERIALS BG

DS-7106

CEM-1; 94V-0;
1,6mm

EN 60335-2-40;
UL 94

Tested with
appliance &
UL
E103670

-Alternative

CHANG CHUN
PLASTICS CO LTD

CCP-508U

CEM-1; 94V-0;
1,6mm

EN 60335-2-40;
UL 94

Tested with
appliance &
UL
E108591

-Alternative

PACIFIC
INSULATING
MATERIAL CO LTD

P-121

CEM-1; 94V-0;
1,6mm

EN 60335-2-40;
UL 94

Tested with
appliance &
UL
E115974

-Alternative

GUANGDONG
S3116
SHENGYI SCI TECH
CO LTD

CEM-1; 94V-0;
1,6mm

EN 60335-2-40;
UL 94

Tested with
appliance &
UL
E109769

-Alternative

Various

Various

CEM-3 or FR-4;
94V-0; CTI 3;
thickness:
1,60,4mm

UL 94;
IEC 60707

S, ETL, UL
or other EU
certification
marks

-High
Frequency
Transformer

TDK XIAMEN Co.,


LTD.

ECO20-11P

LEN 60335-2-40
Pri.:550uH10%;
Lk-Pri:9,5uH MAX;
12,5V/0,8A;
15V/100mA; Class
E

Tested with
appliance

-Alternative

SHENZHEN YAMAXI
ELECTRONICS CO.,
LTD

ECO20-11P

250V/AC; 5EN 60335-2-40


200KHZ; 12,5V;
15V; Pri.R(32):0,4520%;
R(65):0,5320% ;
R(21):0,6820%;Sec
.R(97):120m20%;
R(1211):32.2m30%;
R(107):160m20%; LPri.:550uH10%;
Lk-Pri:9,5uH MAX;
Class B

Tested with
appliance

CECC 42201

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 82 of 139
200uH
200uH/2A

Report. No.: GZ12100571-1R3


EN 60335-2-40
Tested with
appliance

-Inductance

Hangzhou Ruichuang
Industry And Trade
Co., Ltd.

-Alternative

XINJI ELECTRONICS 200uH


COMPONENT(HANG
ZHOU) CO., LTD

200uH/2A

EN 60335-2-40

Tested with
appliance

-Alternative

Shenzhen Yamaxi
Electronic Co., Ltd.

T50-26

200uH/2A

EN 60335-2-40

Tested with
appliance

-Alternative

HUIZHOU JIAYANG
ELECTRONIC NEWTECH CO., LTD

200uH/2A

200uH/2A

EN 60335-2-40

Tested with
appliance

-Alternative

Fenghua Advanced
Technology(Holding)
Co., Ltd.

200uH/2A

200uH; 2A

EN 60335-2-40

Tested with
appliance

-Alternative

Dongguan Dazhong
Electronic Co., Ltd.

200uH/2A

200uH; 2A

EN 60335-2-40

Tested with
appliance

-Filter

XINJI ELECTRONICS SF2022ACOMPONENT(HANG 05220


ZHOU) CO.LTD

AC250V; 0,5A

EN 60335-2-40

Tested with
appliance

-Alternative

SHENZHEN YAMAXI
ELECTRONIC
CO.LTD

SF2022A05220

AC250V; 0,5A

EN 60335-2-40

Tested with
appliance

-Alternative

DAZHONG
ELECTRONIC
CO.LTD

SF2022A05220

AC250V; 0,5A

EN 60335-2-40

Tested with
appliance

-Relay 1#

Electronics(Shenzhen) PCF-112D2M
Co.; Ltd.

250VAC; 25A;
EN 61810-1
250VAC; 20A; T55;
100000 cycles

TV
Rheinland
R50139097

-Alternative

OMRON Relay &


Devices Corporation

G4A-1A-E

250VAC; 20A; T85; EN 61810-1


100000 cycles

TV
Rheinland
R50214482

-Alternative

OMRON Corporation

G4A-1A-E

250VAC; 20A; T50; EN 61810-1


100000 cycles

VDE
107293

-Relay 2#

Xiamen Hongfa
Electroacoustic Co.,
Ltd.

JZC-43F

250VAC; 3A; T85

EN 61810-1
EN 60255-23

VDE
40002220

-Alternative

Omron Electronic
Components
(Shenzhen)LTD

G5NB-1A

250VAC; 3A; T85

EN 60255-23

VDE
137575

-Alternative

Dongguan Sanyou
Electrical Appliances
Co., Ltd.

SRB-S-112DM 277VAC; 5A; T85

EN 61810-1

TV
Rheinland
R50138320

-Alternative

Songchuan Precision
Co., Ltd.

202N-1AC-C

250VAC; 5A; T85

EN 61810-1

VDE
40008369

-Alternative

Tyco Electronics
(Shenzhen) Co., Ltd.

PCJ-112D3M

250VAC; 3A; T90

EN 61810-1

VDE
40009151

-Alternative

Dongguan Churod
Electronics Co., Ltd.

CHM-S112DA3

250VAC; 5A; T90

EN 61810-1

TV
Rheinland
R50196152

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 83 of 139
-Relay 3#
(SSR)

AQH2223

250VAC; 0,9A; T85 EN 60950

VDE
40004928

-Current fuse Hollyland Company


Limited

50CT

AC 250 V; T; H;
3,15A; 5 x 20 mm

VDE
40014896

-Alternative

Walter Electronic Co.


Ltd.

TSC

AC250V; 3,15A; T; EN 60127-1;


H; 5x20mm
EN 60127-2

VDE
40016670

-Alternative

Various

Various

AC 250 V; T; H;
3,15A; 5 x 20 mm

EN 60127-1;

S or other
EU
certification
marks

AC600V; 1,5A

EN 60335-2-40

Tested with
appliance

Terminal
Changzhou
JX-G-4C
board (4 bits) Changheng Kaidu
Electric Appliance Co.,
Ltd.

AC250V; 2,5mm

EN 60998-1

VDE
40020936

Alternative

Zhenjiang Honglian
Electrician Co.; Ltd.

JX1239

250V; 2,5mm

EN 60335-2-40

Tested with
appliance

Alternative

Nantong Huaguan
Electric Co., Ltd.

JXW-4-G1

AC250V; 2,5mm

EN 60998-1

VDE
40013197

-Rectifier

Matsushita Electric
Works Ltd.

Report. No.: GZ12100571-1R3

SHINDENGEN
ELECTRIC MFG CO
LTD

NC 80

EN 60127-1;
EN 60127-2

EN 60127-2

EN 60998-2-1

EN 60998-2-1

Outdoor unit:
Terminal
board

Changzhou
JXD-3
Changheng Kaidu
Electric Appliance Co.,
Ltd.

AC450V; 2,5mm

Alternative

Nantong Huaguan
Electric Co., Ltd.

EN 60335-2-40

Tested with
appliance

AC450V;
2
2,5mm (24A)

EN 60335-2-40

Tested with
appliance

Terminal
Changzhou
JX-G-5H
board (5 bits) Changheng Kaidu
for A3
Electric Appliance Co.,
Ltd.

AC300V; 4,0mm

EN 60335-2-40

Tested with
appliance

Alternative

Nantong Huaguan
Electric Co., Ltd.

JXW

AC300V; 4,0mm;
32A

EN 60335-2-40

Tested with
appliance

Compressor

Zhuhai Landa
Compressor Co., Ltd.

QXASD23zX090B

260-350Vdc; 15120Hz; 3 PHASE;


25503%W;
1,157%;
Synthetic

EN 60335-2-34

TV
Rheinland
R50135262

JXW

EN 60335-1

-Thermal
protecor of
compressor

Sensata Technologies 1NT11L-6233


Holland B.V.

Operation:
1153C; Reset:
955C

EN 60730-1

-Alternative

Changzhou
Changrong Electrical
Appliance Co., Ltd

Operation: 115C;
Reset: 95C

EN 60730-1
EN 60730-2-9

HPC

EN 60730-2-9

KEMA
2014531.16
VDE
40032296

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

-Alternative

Jiangsu Changheng
(Group) Control
Devices & Products
Co., Ltd.

Chassiss
electrical
heater only
for
GWH24RDK3DBA5E
and
GWH24RDK3DBE1E
Outdoor fan
motor

Zhenjiang Dongfang
Electric Heating
Technology Co., Ltd.

Page 84 of 139
KSD
Operation: 115C;
Reset: 95C

Report. No.: GZ12100571-1R3


EN 60730-1
VDE
40022995
EN 60730-2-9

DYQ-02-I-230

230V; 160W

EN 60335-2-40

Tested with
appliance

200-370VDC;
90W; Class E

EN 60335-2-40

Tested with
appliance

Zhuhai Kaibang Motor LW92K-ZL


Manufacturing Co.,
Ltd.

4 ways valve Zhejiang Dunan


Artificial
Environmental
Equipment Co., Ltd.

DSF-9-R410A AC220V-240V;
EN 60730-1
50/60Hz; 7/5W;
1970197; Class
B

VDE
40013212

Alternative

Zhejiang Dunan
Artificial Environment
Co.; Ltd.

DSF-9-R410A AC220-240 V;
EN 60730-1
50/60Hz; 4-6 W;
1470100; Class
B

TV
Rheinland
R 50017212

Alternative

Zhejiang Sanhua
SHF-7H-34UClimate and Appliance PG
Controls Group Co.,
Ltd.

220-240V;
EN 60730-1
50/60Hz; 4,5/3,5W;
Class B;
2085208

VDE
40003240

Reactor

QINGDAO YUNLU
ENERGY
TECHNOLOGY CO
LTD

R 315D

3mH/22A; 60m
(20C); Class H

EN 60335-2-40

tested with
appliance

Alternative

HEFEI ECRIEETAMURA ELECTRIC


CO., LTD

L3mH/22A

3mH/22A; 60m
(20C); Class H

EN 60335-2-40

tested with
appliance

Main Board

GREE

W8303GB(TI)

---

EN 60335-2-40

Tested with
appliance

-Fuse 1#

HOLLYLANDCOLTD

65TS

AC250V; 30A

EN 60127-1

TV
Rheinland
J50136250

EN 60127-2
-Fuse 2#

Walter Electronic
Co.Ltd.

ICP

AC 250V; 3,15A; T EN 60127-1

-Alternative

Various

Various

AC 250 V; T; 3,15A EN 60127-1;


EN 60127-3

S or other
EU
certification
marks

-Y capacitor

TDK-EPC
Corporation,
Capacitors Group

CS103M

250VAC; 103M; Y2 IEC 60384-14;


EN132400

VDE
40029781

EN 60127-3

VDE
40012824

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 85 of 139
Report. No.: GZ12100571-1R3
250VAC; 103M; Y2 IEC 60384-14;
Various
S or other
EU
EN 132400
certification
marks

-Alternative

Various

-X capacitor
1#

Xiamen Faratronic
Co., Ltd.

MKP62

105K; 275V; T110

EN 60384-14

VDE
40000358

-Alternative

Anhui Xinyang
Electronics Co., Ltd.

MKP

1,0F; 275V; T100 EN 60384-14

VDE
40024537

-Alternative

Pilkor Electronics Ltd.

PCX2 335M

1,0F; 275V; T85

ENEC:

EN 60384-14

SE/0256-2
-Alternative

Various

Various

1,0F; AC275V;
T85 or above; X2

IEC 60384-14;
EN 132400

S or other
EU
certification
marks

-X capacitor
2#

Xiamen Faratronic Co. MKP62


Ltd.

225K; 275V; T110

EN 60384-14

VDE
40000358

-Alternative

Okaya Electric
Industries Co.; Ltd.

LE225

2,2F; 275V;T100

EN 60384-14

ENEC:SE/0
142-1D

-Alternative

Various

Various

2,2F; AC275V;
T100; X2

IEC 60384-14;

S or other
EU
certification
marks

275VAC; 104M;
T110

EN 132400;

0,1F; AC275V;
T100

IEC 60384-14;

275VAC; 0,1F;
T100

IEC 60384-14;

0,1F; AC275V;
T100 or above

IEC 60384-14;

-X Capacitor Xiamen Faratronic


3#
Co., Ltd.

MKP62

-Alternative

Anhui Xinyang
Electronics Co., Ltd.

MKP

OKAYA Electric
Industries Co., Ltd.

LE104

Various

Various

-Alternative

-Alternative

EN 132400

IEC 60384-14

EN 132400

EN 132400

EN 132400

VDE
40000358
VDE
40024537
SEMKO
SE/0142-1D
S or other
EU
certification
marks

-PTC
Resistance

Hubei Huagong Gaoli


Electronic Co., Ltd.

MZ8I EB500K

R:5010%

EN 60335-2-40

Tested with
appliance

-Alternative

Dandong Guotong
Electronic
Components Co., Ltd

MZ9250RM

R:5010%

EN 60335-2-40

tested with
appliance

-Optocoupler

Toshiba Corporation

TLP781

Vceo:80V; If:60mA; EN 60747-5-2


Ic:50mA

VDE
40021173

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 86 of 139
-High
Frequency
Transformer

DONGGUAN
DAZHONG
ELECTRONIC
LTD

-Inductance

ECO2020

Report. No.: GZ12100571-1R3

85~265V; 132KH; EN 60335-2-40


15V; 8V; Pri.R:21:750m20%; 32:560m20%; 65:80m20%;
Sec.R:1011:23m20%; 1112:33m20%; LPri.:0,676mH; LkPri:20uH; 15uH;
Class B

Tested with
appliance

XINJI ELECTRONICS 10uH


COMPONENT(HANG
ZHOU) CO. LTD

10uH; 1,5A

EN 60335-2-40

Tested with
appliance

-Alternative

Shenzhen Yamaxi
Electronic Co., Ltd.

10uH

10uH; 1,5A

EN 60335-2-40

Tested with
appliance

-Alternative

Dongguan Dazhong
Electronic Co., Ltd.

10uH

10uH; 1,5A

EN 60335-2-40

Tested with
appliance

-PCB
material

CHANG CHUN
PLASTICS CO LTD

CCP-508U

CEM-1; 94V-0;
1,6mm

EN 60335-2-40;
UL 94

Tested with
appliance &
UL
E108591

-Alternative

PACIFIC
INSULATING
MATERIAL CO LTD

P-121

CEM-1; 94V-0;
1,6mm

EN 60335-2-40;
UL 94

Tested with
appliance &
UL
E115974

-Alternative

S3116
GUANGDONG
SHENGYI SCI TECH
CO LTD

CEM-1; 94V-0;
1,6mm

EN 60335-2-40;
UL 94

Tested with
appliance &
UL
E109769

-Alternative

Various

Various

CEM-3 or FR-4;
94V-0; CTI 3;
thickness:
1,60,4mm

UL 94;
IEC 60707

S, ETL, UL
or other EU
certification
marks

SLA6868M

VDSS: 500V;
VCC:20V; I:2,5A;
IP: 5A; PD: 32,8W

EN 60335-2-40

Tested with
appliance

EN 60335-2-40

Tested with
appliance

CO.,

-IPM module Sanken Electric Co.,


Ltd.
-Alternative

MITSUBISHI
ELECTRIC CORP
SEMICONDUCTOR
DIV

PS21997-AST Operation:600V;
30A; Fsw=20KHz;
Viso=2500V

-Relay 1#

Xiamen Hongfa
Electroacoustics Co.,
Ltd.

JQX-102F

-Alternative

OMRON Relay &


Devices Corporation

G4A-1A-E-CN 250VAC; 20A; T85; EN 61810-1


100000 cycles

TV
Rheinland
R50214482

-Alternative

OMRON Corporation

G4A-1A-E-CN 250VAC; 20A; T50; EN 61810-1


100000 cycles

VDE
107293

-Alternative

Dongguan Sanyou
Electrical
Appliances Co., Ltd.

SFK-112DM

VDE
40007481

AC250 V; 20 A;
EN 61810-1
T85; 100000cycles

AC250 V; 20A; T85 EN 61810-1;


EN 60255-23

VDE
40024142

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 87 of 139
Report. No.: GZ12100571-1R3
Song Chuan Precision 891WP-1A-C AC250 V; 25A;
EN 61810-1
TV
Co., Ltd.
Rheinland
T85; 100000cycles EN 61810-5
R50003966
EN 60255-23

-Alternative

-Alternative

Tyco Electronics
(Shenzhen)
Co., Ltd.

EF00-1A2D012-F

AC250 V; 20A;
EN 61810-1
T85; 100000cycles

TV
Rheinland
R50117320

-Relay 2#

Xiamen Hongfa
Electroacoustics Co.,
Ltd.

JZC-32F

250VAC; 5A; T70;


100000 cycles

EN 61810-1

VDE
40012204

-Alternative

Dongguan Sanyou
Electrical Appliances
Co., Ltd.

SJ-S-112DM

250VAC; 5A; T85;


100000 cycles

EN 61810-1

VDE
40002146

250VAC; 5A; T85;


10000 cycles

EN 61810-1

-Alternative

Song Chuan Precision 307-1AH-C


Co., Ltd.

EN 60255-23

IEC 61810-1

TV
Rheinland
R 50128391

-Alternative

Tyco Electronics
(Shenzhen) Co., Ltd.

OJE-SS112DM

250VAC; 5A; T70;


100000 cycles

EN 61810-1
IEC 61810-1

TV
Rheinland
R50139166

-Alternative

Tyco Electronics
(Shenzhen)
Co., Ltd.

OJT-SH112DM

250VAC; 5A; T70;


100000 cycles

-Relay 3#

Xiamen Hongfa
Electroacoustics Co.,
Ltd.

HF32F-G

250VAC; 10A; T85; EN 61810-1


100000 cycles

VDE
40012204

-Alternative

Dongguan Sanyou
Electrical Appliances
Co., Ltd.

SJ-S-112DM

250VAC; 10A; T85; EN 61810-1


100000 cycles

TV
Rheinland
R50142420

-Alternative

Song Chuan Precision 835-1A-B-C


Co. Ltd.

250VAC; 10A; T85; EN 61810-1;


50000 cycles
EN 60255-23

VDE

-Alternative

Tyco Electronics
(Shenzhen)
Co., Ltd.

OJE-SS112HMF

250VAC; 10A; T70; EN 61810-1


100000 cycles

TV
Rheinland
R50139166

-Alternative

Dongguan Churod
Electronics Co., Ltd.

A1-S-112HAF

250VAC; 10A; T85 EN 61810-1

TV
Rheinland
R50174892

-Rectifier

Shanghai Microsemi
Semiconductor Co.,
Ltd.

GBJ25J

600V; 25A

EN 60335-2-40

Tested with
appliance

-Alternative

SHINDENGEN
ELECTRIC MFG CO
LTD

D25XB 60

600V; 25A

EN 60335-2-40

Tested with
appliance

28.1

EN 61810-1
EN 60255-23

VDE
40007630

40010643

TABLE: Threaded part torque test

Threaded part identification


Earthed screw

Diameter of thread
(mm)

Column number
(I, II, or III)

Applied torque ( Nm )

4,0

II

1,2

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 88 of 139
29.1

Report. No.: GZ12100571-1R3


P

TABLE: Clearances
Overvoltage category.... :

II
Type of insulation:

Rated impulse
voltage (V):

Min. cl
(mm)

Basic

Functional

Supplementary

Reinforced

Verdict / Remark

330

0,5

---

---

---

---

N/A

500

0,5

---

---

---

---

N/A

800

0,5

---

---

---

---

N/A

1 500

0,5

---

---

---

---

N/A

2 500

1,5

3,5

4,0

>5,0

---

Pass

4 000

3,0

---

---

---

>10,0

Pass

6 000

5,5

---

---

---

---

N/A

8 000

8,0

---

---

---

---

N/A

10 000

11,0

---

---

---

---

N/A

29.2

TABLE: Creepage distances, basic, supplementary and reinforced insulation

Working voltage
(V)

Creepage distance
(mm)
Pollution degree
1

Material group

Material group

II

IIIa/IIIb

II

Type of insulation

IIIa/IIIb

B*

S*

R*

Verdict

N/A

N/A

50

0,2

0,6

0,9

1,2

1,5

1,7

1,9

50

0,2

0,6

0,9

1,2

1,5

1,7

1,9

50

0,4

1,2

1,8

2,4

3,0

3,4

3,8

>50 and 125

0,3

0,8

1,1

1,5

1,9

2,1

2,4

>50 and 125

0,3

0,8

1,1

1,5

1,9

2,1

2,4

>50 and 125

0,6

1,6

2,2

3,0

3,8

4,2

4,8

>125 and 250

0,6

1,3

1,8

2,5

3,2

3,6

4,0

3,5

>125 and 250

0,6

1,3

1,8

2,5

3,2

3,6

4,0

>5,0

>125 and 250

1,2

2,6

3,6

5,0

6,4

7,2

8,0

>15

>250 and 400

1,0

2,0

2,8

4,0

5,0

5,6

6,3

N/A

>250 and 400

1,0

2,0

2,8

4,0

5,0

5,6

6,3

N/A

>250 and 400

2,0

4,0

5,6

8,0

10,0

11,2

12,6

N/A

>400 and 500

1,3

2,5

3,6

5,0

6,3

7,1

16,0

N/A

>400 and 500

1,3

2,5

3,6

5,0

6,3

7,1

8,0

>400 and 500

2,6

5,0

7,2

10,0

12,6

14,2

16,0

>500 and 800

1,8

3,2

4,5

6,3

8,0

9,0

10,0

N/A

N/A

N/A
N/A

N/A
N/A

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

>500 and 800

1,8

3,2

4,5

Page 89 of 139
6,3
8,0
9,0

>500 and 800

3,6

6,4

9,0

12,6

16,0

18,0

20,0

>800 and 1000

2,4

4,0

5,6

8,0

10,0

11,0

12,5

>800 and 1000

2,4

4,0

5,6

8,0

10,0

11,0

12,5

>800 and 1000

4,8

8,0

11,2

16,0

20,0

22,0

25,0

>1000 and 1250

3,2

5,0

7,1

10,0

12,5

14,0

16,0

>1000 and 1250

3,2

5,0

7,1

10,0

12,5

14,0

16,0

>1000 and 1250

6,4

10,0

14,2

20,0

25,0

28,0

32,0

>1250 and 1600

4,2

6,3

9,0

12,5

16,0

18,0

20,0

>1250 and 1600

4,2

6,3

9,0

12,5

16,0

18,0

20,0

>1250 and 1600

8,4

12,6

18,0

25,0

32,0

36,0

40,0

>1600 and 2000

5,6

8,0

11,0

16,0

20,0

22,0

25,0

>1600 and 2000

5,6

8,0

11,0

16,0

20,0

22,0

25,0

>1600 and 2000

11,2 16,0

22,0

32,0

40,0

44,0

50,0

>2000 and 2500

7,5

10,0

14,0

20,0

25, 0 28,0

32,0

>2000 and 2500

7,5

10,0

14,0

20,0

25, 0 28,0

32,0

>2000 and 2500

15,0 20,0

28,0

40,0

50,0

56,0

64,0

>2500 and 3200

10,0 12,5

18,0

25,0

32,0

36,0

40,0

>2500 and 3200

10,0 12,5

18,0

25,0

32,0

36,0

40,0

>2500 and 3200

20,0 25,0

36,0

50,0

64,0

72,0

80,0

>3200 and 4000

12,5 16,0

22,0

32,0

40,0

45,0

50,0

>3200 and 4000

12,5 16,0

22,0

32,0

40,0

45,0

50,0

>3200 and 4000

25,0 32,0

44,0

64,0

80,0

90,0

100,0

>4000 and 5000

16,0 20,0

28,0

40,0

50,0

56,0

63,0

>4000 and 5000

16,0 20,0

28,0

40,0

50,0

56,0

63,0

>4000 and 5000

32,0 40,0

56,0

80,0

100,0

112,0

126,0

>5000 and 6300

20,0 25,0

36,0

50,0

63,0

71,0

80,0

>5000 and 6300

20,0 25,0

36,0

50,0

63,0

71,0

80,0

>5000 and 6300

40,0 50,0

72,0

100,0

126,0

142,0

160,0

>6300 and 8000

25,0 32,0

45,0

63,0

80,0

90,0

100,0

>6300 and 8000

25,0 32,0

45,0

63,0

80,0

90,0

100,0

>6300 and 8000

50,0 64,0

90,0

126,0

160,0

180,0

200,0

>8000 and 10000

32,0 40,0

56,0

80,0

100,0

110,0

125,0

>8000 and 10000

32,0 40,0

56,0

80,0

100,0

110,0

125,0

>8000 and 10000

64,0 80,0

112,0

160,0

200,0

220,0

250,0

71,0

100,0

125,0

140,0

160,0

>10000 and 12500 40,0 50,0

10,0

Report. No.: GZ12100571-1R3


N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

>10000 and 12500 40,0 50,0

71,0

Page 90 of 139
100,0
125,0 140,0

>10000 and 12500 80,0 100,0

142,0

200,0

250,0

280,0

Report. No.: GZ12100571-1R3


160,0
N/A

320,0

N/A

* , B=Basic, S=Supplementary and R=Reinforced;


29.2

TABLE: Creepage distances, functional insulation

Working voltage
(V)

Creepage distance
(mm)
Pollution degree
1

Material group

Material group

II

IIIa/IIIb

II

IIIa/IIIb

Verdict / Remark

50

0,2

0,6

0,8

1,1

1,4

1,6

1,8

N/A

>50 and 125

0,3

0,7

1,0

1,4

1,8

2,0

2,2

N/A

>125 and 250

0,4

1,0

1,4

2,0

2,5

2,8

3,2

P / 4,0mm, L & N pole on


PCB

>250 and 400

0,8

1,6

2,2

3,2

4,0

4,5

5,0

N/A

>400 and 500

1,0

2,0

2,8

4,0

5,0

5,6

6,3

N/A

>500 and 800

1,8

3,2

4,5

6,3

8,0

9,0

10,0

N/A

>800 and 1000

2,4

4,0

5,6

8,0

10,0

11,0

12,5

N/A

>1000 and 1250

3,2

5,0

7,1

10,0

12,5

14,0

16,0

N/A

>1250 and 1600

4,2

6,3

9,0

12,5

16,0

18,0

20,0

N/A

>1600 and 2000

5,6

8,0

11,0

16,0

20,0

22,0

25,0

N/A

>2000 and 2500

7,5

10,0

14,0

20,0

25,0

28,0

32,0

N/A

>2500 and 3200

10,0 12,5

18,0

25,0

32,0

36,0

40,0

N/A

>3200 and 4000

12,5 16,0

22,0

32,0

40,0

45,0

50,0

N/A

>4000 and 5000

16,0 20,0

28,0

40,0

50,0

56,0

63,0

N/A

>5000 and 6300

20,0 25,0

36,0

50,0

63,0

71,0

80,0

N/A

>6300 and 8000

25,0 32,0

45,0

63,0

80,0

90,0

100,0

N/A

>8000 and 10000

32,0 40,0

56,0

80,0

100,0

110,0

125,0

N/A

>10000 and 12500 40,0 50,0

71,0

100,0

125,0

140,0

160,0

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

TABLE 30

Page 91 of 139

Report. No.: GZ12100571-1R3

RESISTANCE TO HEAT, FIRE AND TRACKING (appended table)

Ball pressure test


Component

Manufacturer

Type
75C

Terminal block
Terminal block

cl. 11
cl. 19
+40C 125C +25C

Tracking
test
GWT
[CTI/
550C
PTI]

GWT
650C

GWT
750C

GWFI
850C

GWIT

Needleflame
test

Verdict

Honglian

----

----

----

0,8

----

----

----

----

No flame

Ti:12,1s;
Te:32,0s

----

----

Kaidu

----

----

----

1,2

----

----

----

----

No flame

Ti:1,4s;
Te: 31,4s

----

----

----

----

1,3

----

----

----

----

Ti:1,4
s; Te:
31,7s

----

----

----

----

----

----

----

----

----

1,0

----

----

----

----

----

----

----

----

Enclosure

PCB

Glow wire test

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 92 of 139

Report. No.: GZ12100571-1R3

Photo documents:
Following photos are for all indoor units except especial note:

Front view for GWH24RD-K3DNA3C

Front view for GWH24RD-K3DNA2C

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 93 of 139

Report. No.: GZ12100571-1R3

Side view for GWH24RD-K3DNA3C

Side view for GWH24RD-K3DNA3C


Remark: the side view for model GWH24RD-K3DNA2C is the same as GWH24RD-K3DNA3C except the
front cover.

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 94 of 139

Report. No.: GZ12100571-1R3

Top view

Back view

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 95 of 139

Report. No.: GZ12100571-1R3

Room temperature sensor location

Opened front cover

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 96 of 139

Report. No.: GZ12100571-1R3

Control panel
location

Removed air filter

Terminal block cover

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 97 of 139

Report. No.: GZ12100571-1R3

Terminal block view

Removed front cover

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 98 of 139

Report. No.: GZ12100571-1R3

Earthing terminal

Earthing terminal on evaporator

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 99 of 139

Report. No.: GZ12100571-1R3

Cold plasma
generator

Electric external view

Front view of main board

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 100 of 139

Report. No.: GZ12100571-1R3

Back view of main board

Front view of display PCB

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 101 of 139

Report. No.: GZ12100571-1R3

Back view of display PCB

Anchorage of power supply cord

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 102 of 139

Report. No.: GZ12100571-1R3

Indoor fan motor

Cold plasma generator view

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 103 of 139

Report. No.: GZ12100571-1R3

Following photos are for the new models:

Front panel view for model GWH24RD-K3DNA6C

Front panel view for model GWH24RD-K3DNA8C

Front panel view for model GWH24RD-K3DBA5E

Front panel view for model GWH24RD-K3DBE1E

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 104 of 139

Report. No.: GZ12100571-1R3

Front panel view for model GWH24RD-K3DNA5C

Front panel view for model GWH24RD-K3DBA3E

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 105 of 139


The following photos are for the outdoor unit:

Report. No.: GZ12100571-1R3

Front view

Side view

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 106 of 139

Report. No.: GZ12100571-1R3

Side view

Temperature
sensor

Back view

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 107 of 139

Report. No.: GZ12100571-1R3


Main board location

Top view

Earthing terminal, terminal block and cord anchorage view

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 108 of 139

Report. No.: GZ12100571-1R3

Removed front cover

External view of electric box

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 109 of 139

Report. No.: GZ12100571-1R3

Internal view of electric box

Front view of outdoor main board

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 110 of 139

Report. No.: GZ12100571-1R3

Back view of outdoor main board

Outdoor fan motor

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 111 of 139

Report. No.: GZ12100571-1R3

Reactor view

Compressor view

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 112 of 139

Report. No.: GZ12100571-1R3

Earthing terminal block on compressor

Chassiss electric heater view only for model GWH24RD-K3DBA5E and GWH24RD-K3DBA3E

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 113 of 139


Appendix to TRF no. IECEN60335_2_40B

Report. No.: GZ12100571-1R3

AMENDMENT 2:2006 TO IEC 60335-1:2001


AMENDMENT 2:2006 TO EN 60335-1:2002
Clause

Requirement Test

GENERAL CONDITIONS FOR THE TESTS

5.3

(Addition:)

Result

Verdict
--N/A

The test of 19.14 is carried out before the tests


of 19.11 (IEC/EN 60335-1/A2:2006)

MARKING AND INSTRUCTIONS

---

7.5

(Replacement:)

the power input is related to the arithmetic mean


value of the rated voltage range (IEC/EN
60335-1/A2:2006)
7.6

(Replacement:)

N/A

-symbol IEC 60417-5032-1 (DB:2002-10)


-symbol IEC 60417-5032-2 (DB:2002-10)
(IEC/EN 60335-1/A2:2006)
(Replacement:)

N/A

-symbol ISO 7000-1641 (DB:2004-01)


(IEC/EN 60335-1/A2:2006)
(Addition:)

N/A

-symbol ISO 7000-0790 (DB:2004-01)


(IEC/EN 60335-1/A2:2006)
7.12

(Addition:)

This appliance is not intended for use by


persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety (IEC/EN 603351/A2:2006)
(Addition:)

Children should be supervised to ensure that


they do not play with the appliance
(IEC/EN 60335-1/A2:2006)

PROTECTION AGAINST ACCESS TO LIVE PARTS

---

8.1.1

Renumber the existing note as Note 1.

Add the following note after the third


TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 114 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

paragraph of the test specification:


NOTE 2 Without appreciable force is
considered to be a force not exceeding 1 N.
(IEC/EN 60335-1/A2:2006)
8.1.2

Renumber the existing note as Note 1.

Add the following note after the third


paragraph of the test specification:
NOTE 2 Without appreciable force is
considered to be a force not exceeding 1 N.
(IEC/EN 60335-1/A2:2006)
8.1.3

Add the following note after the first paragraph


of the test specification:

N/A

NOTE 1 Without appreciable force is


considered to be a force not exceeding 1 N.
Renumber the existing note as Note 2.
(IEC/EN 60335-1/A2:2006)
8.1.4

Accessible part not considered live if:


(Addition:)

--N/A

for voltages having a peak value over 15 kV,


the energy in the discharge shall not exceed
350 mJ.(IEC/EN 60335-1/A2:2006)
(Replace the third sentence of the second
paragraph of the test specification by the
following:)

N/A

The quantity of electricity and energy in the


discharge is measured using a resistor having
anominal non-inductive resistance of 2 000
(IEC/EN 60335-1/A2:2006)
8.2

(Replacement)

Compliance is checked by inspection and by


applying test probe B of IEC 61032 in
accordance with the conditions specified in
8.1.1.(IEC/EN 60335-1/A2:2006)

10

POWER INPUT AND CURRENT

10.1

(Addition:)

--N/A

The permissible deviations apply for both limits


of the range for appliances marked with a
rated voltage range having limits differing by
more than 10 % of the arithmetic mean value
of the range. ( IEC/EN 60335-1/A2:2006)
(Addition:)

N/A

The test is carried out at both the upper and


lower limits of the ranges for appliances
marked with one or more rated voltage ranges,
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 115 of 139


Clause

Requirement Test
unless

Report. No.: GZ12100571-1R3


Result

Verdict

( IEC/EN 60335-1/A2:2006)

(Addition:)

the marking of the rated power input is related


to the arithmetic mean value of the relevant
voltage range, in which case the test is carried
out at a voltage equal to the arithmetic mean
value of that range (IEC/EN 60335-1/A2:2006)
10.2

(Addition:)

N/A

The permissible deviations apply for both limits


of the range for appliances marked with a
rated voltage range having limits differing by
more than 10 % of the arithmetic mean value
of the range. ( IEC/EN 60335-1/A2:2006)
(Addition:)

N/A

The test is carried out at both the upper and


lower limits of the ranges for appliances
marked with one or more rated voltage ranges,
unless
( IEC/EN 60335-1/A2:2006)
(Addition:)

N/A

the marking of the rated current is related to


the arithmetic mean value of the relevant
voltage range, in which case the test is carried
out at a voltage equal to the arithmetic mean
value of that range (IEC/EN 60335-1/A2:2006)

11

HEATING
(Replacement:)

--N/A

Table 3 - Maximum normal temperature rises


replace the terms class A, class E, class B,
class F and class H by the terms class 105,
class 120, class 130, class 155 and class 180
(IEC/EN 60335-1/A2:2006)
(Replacement:)

N/A

Rubber, polychloroprene or polyvinyl chloride


insulation of internal and external wiring,
including supply cords: (IEC/EN 603351/A2:2006)
- without temperature rating or with a
temperature rating not exceeding 75C,
limit:50K (IEC/EN 60335-1/A2:2006)

N/A

- with temperature rating (T) where T exceeds


75C, limit: T-25 (IEC/EN 60335-1/A2:2006)

N/A

Add the following paragraph to footnote:

N/A

The temperature rise limit of windings in


transformers and inductors mounted on
printed circuit boards is equal to the thermal
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 116 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

class of the winding insulation reduced by 25 K


provided the largest dimension of the winding
does not exceed 5 mm in cross section or
length. (IEC/EN 60335-1/A2:2006)
Add the following footnote:

14

---

IEC 60245 Types 53, 57 and 87 supply cords


have a T rating of 60 C; (IEC/EN 603351/A2:2006)

N/A

IEC 60227 Types 52 and 53 supply cords have


a T rating of 70 C; (IEC/EN 60335-1/A2:2006)

N/A

EC 60227 Types 56 and 57 supply cords have


a T rating of 90 C. (IEC/EN 60335-1/A2:2006)

N/A

TRANSIENT OVERVOLTAGES
(Replacement:)

--N/A

Impulse test voltage has a no-load waveshape


corresponding to the 1,2/50 s standard
impulse specified in IEC 61180-1, supplied
from a generator having a conventional
impedance not exceeding 42 ohms.
(IEC/EN 60335-1/A2:2006)
Impulse test voltage is applied three times for
each polarity with intervals of at least 1 s

N/A

(IEC/EN 60335-1/A2:2006)

16

LEAKAGE CURRENT AND ELECTRIC STRENGTH

---

16.3

(Replacement:)

Immediately after the test of 16.2, the


insulation is subjected to a voltage having a
frequency of 50 Hz or 60Hz for 1 min in
according with IEC 61180-1. (IEC/EN 603351/A2:2006)

19

ABNORMAL OPERATION
This clause of part 1 is replaced by part 2.

22

CONSTRUCTION

22.2

(Replacement:)

--N/A

--N/A

Single-pole switches and single-pole protective


devices that disconnect heating elements from
the supply mains in single-phase, permanently
connected class 0I appliances and class I
appliances shall be connected to the phase
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 117 of 139


Clause

Requirement Test
conductor.

22.5

Report. No.: GZ12100571-1R3


Result

Verdict

(IEC/EN 60335-1/A2:2006)

(Replacement:)

N/A

No risk of electric shock from a capacitor


having a rated capacitance exceeding 0.1uF
when touching the pins of the plug, the
appliance being disconnected from the supply
at the instant of voltage peak. (IEC/EN 603351/A2:2006)

22.21

The voltage shall not exceed 34 V

N/A

(Addition:)

N/A

This requirement does not apply to


magnesium oxide and mineral ceramic fibres
used for the electrical insulation of heating
elements (IEC/EN 60335-1/A2:2006)
22.32

(Addition:)

N/A

Insulating material in which heating conductors


are embedded is considered to be basic
insulation and not reinforced insulation.
(IEC/EN 60335-1/A2:2006)
22.35

(Replacement:)

N/A

For constructions other than those of class III,


handles, levers and knobs that are held or
actuated in normal use shall not become live in
the event of a failure of basic insulation
(IEC/EN 60335-1/A2:2006)

22.40

If these handles, levers and knobs are of metal


and if their shafts or fixings are likely to
become live in the event of a failure of basic
insulation, they shall be adequately covered by
insulating material or their accessible parts
shall be separated from their shafts or fixings
by supplementary insulation. (IEC/EN 603351/A2:2006)

N/A

(Addition:)

N/A

Unless the appliance can operate


continuously, automatically or remotely without
giving rise to a hazard, appliances for remote
operation shall be fitted with a switch for
stopping the operation of the appliance. The
actuating member of this switch shall be easily
visible and accessible. (IEC/EN 603351/A2:2006)
22.44

(Replacement:)

Appliances shall not have an enclosure that is


shaped or decorated like a toy.
(IEC/EN 60335-1/A2:2006)
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 118 of 139


Clause

Requirement Test

22.49

(Addition:)

Report. No.: GZ12100571-1R3


Result

Verdict
N/A

For remote operation, duration of operation set


before the appliance can be started unless the
appliance switches off automatically at the end
of a cycle or it can operate continuously
without giving rise to a hazard. (IEC/EN 603351/A2:2006)
22.50

(Addition:)

N/A

Controls incorporated in the appliance, if any,


shall take priority over controls actuated by
remote operation. (IEC/EN 60335-1/A2:2006)
22.51

(Addition)

N/A

A control on the appliance shall be manually


adjusted to the setting for remote operation
before the appliance can be operated in this
mode. There shall be a visual indication on the
appliance showing that the appliance is
adjusted for remote operation. The manual
setting and the visual indication of the remote
mode are not necessary on appliances that
can
- operate continuously, or
- operate automatically, or
- be operated remotely,
without giving rise to a hazard. (IEC/EN
60335-1/A2:2006)
22.52

(Addition :)

N/A

Socket-outlets on appliances accessible to the


user shall be in accordance with the socketoutlet system used in the country in which the
appliance is sold. (IEC/EN 60335-1/A2:2006)

24

COMPONENTS

24.1

(Replacement:)
Components not tested and found to comply
with relevant IEC standard for the number of
cycles specified are tested in accordance with
24.1.1 to 24.1.9 (IEC/EN 60335-1/A2:2006)
(Addition:)
Lampholders and starterholders that have not
been previously tested and found to comply
with the relevant IEC standard are tested as a
part of the appliance and shall additionally
comply with the gauging and interchangeability
requirements of the relevant IEC standard
under the conditions occurring in the
appliance.

--Replaced by IEC/EN 603351/A14: 2010, See appendix

---

Replaced by IEC/EN 603351/A14: 2010, See appendix

---

(IEC/EN 60335-1/A2:2006)
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 119 of 139

Report. No.: GZ12100571-1R3

Clause

Requirement Test

Result

24.1.7

(Addition:)

Replaced by IEC/EN 603351/A13: 2008, See appendix

If the remote operation of the appliance is via a


telecommunication network, the relevant
standard for the telecommunication interface
circuitry in the appliance is IEC 62151

Verdict
---

(IEC/EN 60335-1/A2:2006)
24.1.8

(Addition:)

N/A

The relevant standard for thermal links is IEC


60691. Thermal links that do not comply with
IEC 60691 are considered to be an
intentionally weak part for the purposes of
Clause 19.
(IEC/EN 60335-1/A2:2006)
24.1.9

(Addition:)

Relays, other than motor starting relays, are


tested as part of the appliance. However, they
are also tested in accordance with Clause 17
of IEC 60730-1 under the maximum load
conditions occurring in the appliance for at
least the number of operations in 24.1.4
selected according to the relay function in the
appliance. (IEC/EN 60335-1/A2:2006)

25

SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS

---

25.7

(Replacement:)

---

Supply cords shall be one of the following types: (IEC/EN 60335-1/A2)


Rubber sheathed (code designation 60245
IEC 53)
(IEC/EN 60335-1/A2:2006)
Polychloroprene sheathed (code
designation 60245 IEC 57) (IEC/EN 603351/A2:2006)

N/A
H05VV-F

Cross-linked polyvinyl chloride sheathed


(code designation 60245 IEC 87) (IEC/EN
60335-1/A2:2006)
Polyvinyl chloride sheathed.
These cords shall not be used if they are likely to touch metal parts having a
temperature rise exceeding 75 K during the test of Clause 11. Their properties
shall be at least those of (IEC/EN 60335-1/A2:2006)

N/A

---

light polyvinyl chloride sheathed cord (code


designation 60227 IEC 52), for appliances
having a mass not exceeding 3 kg;
(IEC/EN 60335-1/A2: 2006)

N/A

ordinary polyvinyl chloride sheathed cord


(code designation 60227 IEC 53), for other
appliances; (IEC/EN 60335-1/A2:2006)

N/A

Heat resistant polyvinyl chloride sheathed.

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 120 of 139


Clause

Report. No.: GZ12100571-1R3

Requirement Test

Result

Verdict

These cords shall not be used for type X attachment other than specially
prepared cords. Their properties shall be at least those of (IEC/EN 603351/A2:2006)
heat-resistant light polyvinyl chloride
sheathed cord (code designation 60227 IEC
56), for appliances having a mass not
exceeding 3 kg; (IEC/EN 60335-1/A2:2006)

N/A

heat-resistant polyvinyl chloride sheathed


cord (code designation 60227 IEC 57), for
other appliances. (IEC/EN 60335-1/A2:2006)

N/A

26

TERMINALS FOR EXTERNAL CONDUCTORS

26.3

(Replacement:)

--N/A

Compliance checked by inspection and by the


test of subclause 9.6 of IEC 60999-1, the
torque applied being equal to two-thirds of the
torque specified. Nominal diameter of thread
(mm); screw category; torque (Nm) (IEC/EN
60335-1/A2:2006)
26.6

(Replacement:)
Terminals for type X attachment and for
connection to fixed wiring suitable for
connection of conductors with required crosssectional area according to table 13; rated
current (A); nominal cross-sectional area
(mm):

Measured current (Max. ):


11,68A

Nominal cross-sectional area


(mm): 2,5

In Table 13, replace the last two rows by the


following:
> 32 and 50
> 50 and 63
(IEC/EN 60335-1/A2:2006)

27

PROVISION FOR EARTHING

27.6

(Replacement:)

--N/A

The printed conductors of printed circuit


boards not used to provide earthing continuity
in hand held appliances (IEC/EN 603351/A2:2006)
They may be used in other appliances if at
least two tracks are used with independent
soldering points and the appliance complies
with requirements of 27.5 for each circuit
(IEC/EN 60335-1/A2:2006)

28

SCREWS AND CONNECTIONS

N/A

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 121 of 139


Clause

Requirement Test

28.1

(Replacement:)

Report. No.: GZ12100571-1R3


Result

Verdict
N/A

Table 14 the penultimate row: > 4.7 and 5.3


Torque Nm: 0.8, 2.0, 1.0
(IEC/EN 60335-1/A2:2006)
28.3

(Replacement:)

N/A

Thread-cutting (self-tapping) screws and


thread roller screws only used for electrical
connections if they generate a full form
standard machine screw thread. (IEC/EN
60335-1/A2:2006)
Such screws not used if they are likely to be
operated by the user or installer.

N/A

(IEC/EN 60335-1/A2:2006)
Thread-cutting, thread rolling and spacethreaded screws may be used in connections
providing earthing continuity provided it is not
necessary to disturb the connection:

N/A

in normal use,
during user maintenance,
when replacing a supply cord having a type
X attachment, or
during installation.
(IEC/EN 60335-1/A2:2006)
At least two screws must be used for each
connection providing earthing continuity unless
the screw forms a thread having a length of at
least half the diameter of the screw. (IEC/EN
60335-1/A2:2006)

29

CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION


(Replacement:)

N/A

--N/A

For coatings used on printed circuits boards to


protect the microenvironment (Type 1 coating)
or to provide basic insulation (Type 2 coating),
annex J applies (IEC/EN 60335-1/A2:2006)

29.1.1

The microenvironment is pollution degree 1


under Type 1 coating (IEC/EN 603351/A2:2006)

N/A

No creepage distance or clearance


requirements under Type 2 coating (IEC/EN
60335-1/A2:2006)

N/A

(Replacement:)

Clearances of basic insulation withstand the


overvoltages, taking into account the rated
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 122 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

impulse voltage, or cl. 14. (IEC/EN 603351/A2:2006)

30

RESISTANCE TO HEAT AND FIRE

---

30.2

(Replacement:)

Parts of non-metallic material resistant to


ignition and spread of fire (IEC/EN 603351/A2:2006)
This requirement does not apply to decorative
trims, knobs and other parts unlikely to be
ignited or to propagate flames that originate
inside the appliance. (IEC/EN 603351/A2:2006)
Compliance checked by test of 30.2.1

N/A

In addition, (IEC/EN 60335-1/A2:2006)


for attended appliances, 30.2.2 is applicable;
for unattended appliances, 30.2.3 is
applicable.
Appliances for remote operation, 30.2.3 is
applicable (IEC/EN 60335-1/A2:2006)

N/A
P
N/A

For based material of printed circuit boards,


30.2.4 is applicable (IEC/EN 60335-1/A2:2006)

Tests carried out on parts of non-metallic


material that have been removed from the
appliance (IEC/EN 60335-1/A2:2006)

When the glow-wire test is carried out, the


parts are placed in the same orientation as
they would be in normal use

(IEC/EN 60335-1/A2:2006)

30.2.1

These tests are not carried out on the


insulation of wires (IEC/EN 60335-1/A2:2006)

(Replacement:)

Glow-wire test of IEC 60695-2-11 at 550 C,


unless (IEC/EN 60335-1/A2:2006)

30.2.2

the material is classified at least HB40


according to IEC 60695-11-10 (IEC/EN 603351/A2:2006)

N/A

Parts for which the glow-wire test cannot be


carried out meet the requirements in ISO9772
for category HBF material (IEC/EN 603351/A2:2006)

N/A

(Replacement:)

N/A

Appliances operated while attended, parts of


non-metallic supporting current-carrying
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 123 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

connections and parts within a distance of


3mm subjected to the glow-wire test of IEC
60695-2-11 (IEC/EN 60335-1/A2:2006)
However, the glow-wire test is not carried out
on parts of material classified as having a
glow-wire flammability index according to IEC
60695-2-12 of at least:

N/A

(IEC/EN 60335-1/A2:2006)
-750C, for connections carrying a current
exceeding 0,5A during normal operation

N/A

-650C, for other connections

N/A

If the glow-wire flammability index is not


available for a sample with a thickness within
0,1 mm of the relevant part, then the test
sample shall have a thickness equal to the
nearest preferred value specified in IEC
60695-2-12 that is no thicker than the relevant
part.

N/A

NOTE 1 The preferred values in IEC 60695-212 are 0,75 mm 0,1 mm, 1,5 mm 0,1 mm
and 3,0 mm 0,2 mm. (IEC/EN 603351/A2:2006)
Where a non-metallic material is within 3 mm
of a current carrying connection, but is
shielded from the connection by a different
material, the glow-wire test of IEC 60695-2-11
is carried out at the relevant temperature with
the tip of the glow-wire applied to the
interposed shielding

N/A

Material with the shielded material in place and


not directly to the shielded material.
(IEC/EN 60335-1/A2:2006)

30.2.3

-750C, for connections carrying a current


exceeding 0,5A during normal operation
(IEC/EN 60335-1/A2:2006)

N/A

-650C, for other connections (IEC/EN 603351/A2:2006)

N/A

Test not applicable to conditions as specified


(IEC/EN 60335-1/A2:2006)

N/A

(Replacement:)

Appliances operated while unattended, tested


as specified in 30.2.3.1 and 30.2.3.2
(IEC/EN 60335-1/A2:2006)

30.2.3.1

Test not applicable to conditions as specified


(IEC/EN 60335-1/A2:2006)

(Replacement:)

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 124 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

Parts of insulating material supporting


connections carrying a current exceeding 0.2A
during normal operation, and (IEC/EN 603351/A2:2006)

30.2.3.2

Parts of non-metallic material within a distance


of 3 mm of such connections (IEC/EN 603351/A2:2006)

However, the glow-wire test is not carried out


on parts of material classified as having a
glow-wire flammability index of at least 850 C
according to IEC 60695-2-12. (IEC/EN 603351/A2:2006)

N/A

If the glow-wire flammability index is not


available for a sample with a thickness within
0,1 mm of the relevant part, then the test
sample shall have a thickness equal to the
nearest preferred value specified in IEC
60695-2-12 that is no thicker than the relevant
part. (IEC/EN 60335-1/A2:2006)

N/A

The glow-wire test is not carried out on small


parts that comply with Annex E or classify as
V-0 or V-1 according to IEC 60695-11-10,
provided that the sample was not thicker than
the relevant part of the appliance. (IEC/EN
60335-1/A2:2006)

Where a non-metallic material is within 3 mm


of a current carrying connection, but is
shielded from the connection by a different
material, the glow-wire test of IEC 60695-2-11
is carried out at the relevant temperature with
the tip of the glow-wire applied to the
interposed shielding material with the shielded
material in place and not directly to the
shielded material. (IEC/EN 60335-1/A2:2006)

N/A

(Replacement:)

Parts of non-metallic material supporting


current-carrying connections, and (IEC/EN
60335-1/A2:2006)
parts of non-metallic material within a distance
of 3mm, subjected to glow-wire test of IEC
60695-2-11. (IEC/EN 60335-1/A2:2006)

N/A

Test not carried out on material having a glowwire ignition temperature according to IEC
60695-2-13 of at least: (IEC/EN 603351/A2:2006)

N/A

775 C, for connections that carry a current


exceeding 0,2 A during normal operation,

N/A

675 C, for other connections

N/A

If the glow-wire ignition temperature is not


available for a sample with a thickness within

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 125 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

Verdict

0,1 mm of the relevant part, then the test


sample shall have a thickness equal to the
nearest preferred value specified in IEC
60695-2-13 that is no thicker than the relevant
part.
NOTE 1 The preferred values in IEC 60695-213 are 0,75 mm 0,1 mm, 1,5 mm 0,1 mm
and 3,0 mm 0,2 mm. (IEC/EN 603351/A2:2006)
Where an non-metallic material is within 3 mm
of a current carrying connection, but is
shielded from the connection by a different
material, the glow-wire test of IEC 60695-2-11
is carried out at the relevant temperature with
the tip of the glow-wire applied to the
interposed shielding material with the shielded
material in place and not directly to the
shielded material. (IEC/EN 60335-1/A2:2006)
Glow-wire test of IEC 60695-2-11,

N/A

the temperature being: (IEC/EN 603351/A2:2006)


-750C, for connections carrying a current
exceeding 0,2A during normal operation

30.2.4

-650C, for other connections

N/A

Parts that during the test produce a flame


persisting longer than 2 s, tested as specified
(IEC/EN 60335-1/A2:2006)

N/A

If a flame persists longer than 2 s during the


test, parts above the connection, as specified,
subjected to the needle-flame test of annex E,
unless (IEC/EN 60335-1/A2:2006)

N/A

the material is classified as V-0 or V-1


according to IEC 60695-11-10 provided that
the sample was not thicker than the relevant
part of the appliance. (IEC/EN 603351/A2:2006)

N/A

Base material of printed circuit boards


subjected to needle-flame test of annex E

(IEC/EN 60335-1/A2:2006)
Test not applicable to conditions as specified
(IEC/EN 60335-1/A2:2006)

32

RADIATION, TOXICITY AND SIMILAR HAZARDS


(Replacement:)

N/A

--N/A

Appliance does not emit harmful radiation


(IEC/EN 60335-1/A2:2006)
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 126 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

(Replacement:)

Verdict
N/A

Appliance does not present a toxic or similar


hazard (IEC/EN 60335-1/A2:2006)

ANNEX E (NORMATIVE)
NEEDLE-FLAME TEST (IEC/EN 60335-1/A2:2006)

---

Needle-flame test carried out in accordance


with IEC 60695-11-5, with the following
modifications:

Severities

---

(Replacement:)

The duration of application of the test flame is


30 s 1 s
9

Test procedure

---

9.1

(Modification:)

The specimen so arranged that the flame can


be applied to a vertical or horizontal edge as
shown in the examples of figure 1
9.2

(Modification:)

N/A

The first paragraph does not apply


(Addition:)

If possible, the flame is applied at least 10 mm


from a corner
9.3

(Replacement:)

N/A

If the specimen does not withstand the test,


the test may be repeated on two further
specimens, both withstanding the test
11

Evaluation of test results


(Addition:)

--N/A

The duration of burning not exceeding 30 s


(Addition:)

However, for printed circuit boards, the


duration of burning not exceeding 15 s

ANNEX J (NORMATIVE)
COATED PRINTED CIRCUIT BOARDS (IEC/EN 60335-1/A2:2006)
Testing of protective coatings of printed circuit
boards carried out in accordance with IEC
60664-3 with the following modifications:

5.7

Conditioning of the test specimens

--N/A

---

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 127 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result

When production samples are used, three


samples of the printed circuit board are tested
5.7.1

Cold

Rapid change of temperature


Severity 1 is specified

5.9

Additional tests
This subclause is not applicable

N/A
---

The test is carried out at -25C


5.7.3

Verdict

ANNEX O (INFORMATIVE)
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30

N/A
--N/A
--N/A

---

(IEC/EN 60335-1/A2:2006)

Replace Figure 0.2 by the following

ANNEX Q (INFORMATIVE)
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC
CIRCUITS (IEC/EN 60335-1/A2:2006)

---

Replace 19.10 by 19.10 and 19.14 in two


places.

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 128 of 139


Appendix to TRF no. IECEN60335_2_40B

Report. No.: GZ12100571-1R3

Amendment 12:2006 to EN 60335-1:2002


Clause

Requirement Test

29.3

- an assessment of the thermal quality of the


material combined with an electric strength test,
in accordance with 29.3.3 and, (EN 603351/A12:2006)

N/A

for accessible reinforced insulation consisting of


a single layer, measurement in accordance with
29.3.Z1 (EN 60335-1/A12:2006)

N/A

If accessible reinforced insulation consists of a


single layer, the thickness of this layer shall
comply with Table Z1 (EN 60335-1/A12:2006)

N/A

29.3.Z1

Z1

Result Remark

Verdict

TABLE: Minimum thickness for single layer accessible reinforced insulation (EN
60335-1/A12:2006)

Rated voltage
V

N/A

Minimum thickness for single layers used for


accessible reinforced insulation
mm
Overvoltage
category I

Overvoltage
category II

Overvoltage
category III

Verdict

< 50

0,01

0,04

0,1

N/A

>50 and 150

0,1

0,3

0,6

N/A

>150 and 300

0,3

0,6

1,2

N/A

Appendix to TRF no. IECEN60335_2_40B


Amendment 13:2008 to EN 60335-1:2002
Clause

Requirement Test

24

COMPONENTS

24.1.7

(Replacement:)
If the remote operation of the appliance is via a
telecommunication network, the relevant
standards for the telecommunication interface
circuitry in the appliance are EN 41003 and EN
60950-1:2006, Subclause 6.3.

Result Remark

Verdict

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 129 of 139


Appendix to TRF no. IECEN60335_2_40B

Report. No.: GZ12100571-1R3

AMENDMENT 14:2010 TO EN 60335-1:2002

Clause

Requirement Test

19

ABNORMAL OPERATION

19.14

Modification:

Result Remark

Verdict

N/A

Add the content of the note to the requirement


as follows: If a relay or contactor with more
than one contact is used, all contacts are
short-circuited at the same time.
24

COMPONENTS

24.1

Replacement:

---

Components comply with safety requirements


in relevant standards

the requirements of Clause 29 of this standard


apply between live parts of components and
accessible parts of the appliance

the requirements of 30.2 of this standard apply


to parts of non-metallic material in components
including parts of non-metallic material
supporting current-carrying connections inside
components

List of components

(see appended table)

Components not tested and found to comply


with relevant standard for the number of cycles
specified are tested in accordance with 24.1.1
to 24.1.9

Components not tested and found to comply


with relevant standard, components not marked
or not used in accordance with its marking,
tested under the conditions occurring in the
appliance

Lampholders and starterholders that have not


been previously tested and found to comply with
the relevant standard are tested as a part of the
appliance and shall additionally comply with the
gauging and interchangeability requirements of
the relevant standard under the conditions
occurring in the appliance.

N/A

25

SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORES

25.7

Modification:

N/A

Rubber sheathed (code designation 60245


IEC 53)

These cords are not suitable for appliances


intended to be used outdoors or when they are
liable to be exposed to significant amounts of
TRF No.: IECEN60335_2_40B
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 130 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result Remark

Verdict

ultraviolet radiation.
26

TERMINALS FOR EXTERNAL CONDUCTORS

26.2

Modification:

N/A

Change NOTE into requirement:


Conductors connected by soldering are not
considered to be positioned or fixed so that
reliance is not placed upon the soldering alone
to maintain it in position unless they are held in
place near the terminals independently of the
solder.
26.11

Modification:

N/A

Change NOTE into requirement:


Conductors connected by soldering are not
considered to be positioned or fixed so that
reliance is not placed upon the soldering alone
to maintain it in position unless they are held in
place near the terminals independently of the
solder.
29

CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION

29.1

Replacement:

N/A

NOTE 6 Attention is drawn on the fact that for


appliances intended for use at altitudes
exceeding 2 000 m, the altitude correction
factors, relevant to the intended altitude, for
clearances specified in Table A.2 of EN
60664-1 may need to be taken into account.
29.2

Modification:

N/A

Change NOTE 6 into a requirement.


In a double insulation system, the working
voltage for both the basic insulation and
supplementary insulation is taken as the
working voltage across the complete double
insulation system. It is not divided according to
thickness and dielectric constant of the basic
insulation and supplementary insulation.
32

RADIATION, TOXICITY AND SIMILAR HAZARDS

Addition:

Compliance regarding electromagnetic fields is


checked according to EN 50366 or EN 62233.
ZE

Specific additional requirements for appliances


and machines intended for commercial use

N/A

7.1

- business name and full address of the


manufacturer and, where applicable, his
authorized representative;

N/A

- model or type reference, serial number, if

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 131 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result Remark

Verdict

any, and production year;


7.12

7.12.Z1

Instructions shall be provided with the


appliance so that the appliance can be used
safely.

N/A

The instructions shall contain at least the following information:

----

the business name and full address of the


manufacturer and, where applicable, his
authorized representative;

N/A

model or type reference of the appliance as


marked on the appliance itself, except for the
serial number;

N/A

the designation of the appliance together with


its explanation in case it is given by a
combination of letters and/or numbers.

N/A

the general description of the appliance, when


needed due to the complexity of the appliance;

N/A

specific precautions if required during


installation, operation, adjusting, user
maintenance, cleaning, repairing or moving;

N/A

when needed drawings, diagrams,


descriptions and explanations necessary for
the safe use and user maintenance of the
appliance;

N/A

the possible reasonably foreseeable misuse


and, whenever relevant, a warning against the
effects it may have on the safe use of the
appliance;

N/A

The words Original instructions shall appear


on the language version(s) verified by the
manufacturer or by the authorized
representative.

N/A

When a translation of the original instructions


has been provided by a person introducing the
appliance on the market; the meaning of the
sentence Translation of the original
instructions has to appear in the relevant
instructions delivered with the appliance.

N/A

The instructions for maintenance/service to be


done by specialized personnel, mandated by
the manufacturer or the authorized
representative may be supplied in only one
Community language which the specialized
personnel understand.

N/A

The instructions shall indicate the type and


frequency of inspections and maintenance
required for safe operation including the
preventive maintenance measures.

N/A

Wherever needed for specific appliances, information shall be given:

----

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 132 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result Remark

Verdict

on use, transportation, assembly, dismantling


when out of service, testing or foreseeable
breakdowns, if these operations have
consequences on stability of the appliance in
order to avoid overturning, falling or
uncontrolled movements of the appliance or of
its component parts;

N/A

on how to maintain adequate mechanical


stability when in use, during transportation,
assembly, dismantling, scrapping and any
other action involving the appliance;

N/A

on the protective measures to be taken by the


user, including, where appropriate, the
personal protective equipment to be provided;

N/A

on the operating method to be followed in the


event of accident or breakdown; if a blockage
is likely to occur the operating method to safely
unblock the appliance;

N/A

on the specifications on the spare parts to be


used, when these affect the health and safety
of the operator;

N/A

on airborne noise emissions, determined and


declared in accordance with the relevant Part
2.

N/A

19.11.4.8

The appliance shall continue to operate,


without causing any hazard to the user, from
the same point in its operating cycle at which
the voltage fluctuation occurred, or a manual
operation shall be required to restart it.

N/A

20.1

Appliances and their components and fittings


shall have adequate mechanical stability
during transportation, assembly, dismantling
and any other action involving the appliance.

N/A

20.2

Dangerous moving transmission parts shall be


safeguarded either by design or guards.
When guards are used, they shall be fixed
guards, interlocking movable guards or
protective devices.

N/A

Moving parts directly involved in the function of the appliance which cannot be
made completely inaccessible shall be fitted with:

----

fixed guards or interlocking movable


guards preventing access to those sections of
the parts that are not used in the work; and

N/A

adjustable guards restricting access to


those sections of the moving parts where
access is necessary.

N/A

Interlocking movable guards (e.g. the door of


a washing machine) shall be used where
frequent access is required.

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 133 of 139

Report. No.: GZ12100571-1R3

Clause

Requirement Test

21.1

Appliances and their components and fittings


shall have adequate mechanical strength and
be constructed to withstand such rough
handling that may be expected in normal use,
during transportation, assembly, dismantling,
scrapping and any other action involving the
appliance.

N/A

22.ZE.1

For appliances provided with a seat, the seat


has to give adequate stability. The distance
between the seat and the control devices shall
be capable of being adapted to the operator.

N/A

22.ZE.2

For appliances provided with separate devices


for the start and the stop functions, the stop
function shall be unambiguously identifiable
and shall always override the start function.

N/A

For appliances provided with one device


performing the start and the stop function, the
stop function shall be unambiguously
identifiable and shall always override the start
function.

N/A

22.ZE.3

Appliances shall be designed in such a way


that incorrect mounting is avoided, if this can
lead to an unsafe situation. If this is not
possible, information on the correct mounting
shall be given directly on the part and/or the
enclosure.

N/A

22.ZE.4

Where the weight, size or shape prevents


appliances from being moved manually, they
shall be fitted with attachments for lifting gear
or be designed so they can be fitted with such
attachments, or be shaped in such a way that
standard lifting gear can easily be used.

N/A

Appliances to be moved manually shall be


constructed or shall be equipped so that they
can be moved easily and safely.

N/A

The fixing systems of fixed guards which


prevent access to dangerous moving
transmission parts shall only be removable
with the use of tools.

N/A

If such guards have to be removed frequently


their fixing systems shall remain attached to
the fixed guards or to the machine after
removal. Where possible, guards shall be
incapable of remaining in place without their
fixings.

N/A

This does not apply if, after removal of the


screws, or if the component is incorrectly
repositioned, the appliance becomes
inoperative.

N/A

If movable guards are interlocked, the


interlocking devices shall prevent the start of

N/A

22.ZE.5

Result Remark

Verdict

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 134 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result Remark

Verdict

hazardous appliance functions until the


guards are fixed in their position, and give a
stop command whenever they are no longer
closed
Where it is possible for an operator to reach the danger zone before the risk
due to hazardous appliance functions has ceased, movable guards shall be
associated with a guard locking device in addition to an interlocking device
that:

----

prevents the start of hazardous appliance


functions until the guard is closed and locked,
and

N/A

keeps the guard closed and locked until the


risk of injury from the hazardous appliance
functions has ceased.

N/A

Interlocking movable guards shall remain


attached to the appliance when open and they
shall be designed and constructed in such a
way that they can be adjusted only by means
of an intentional action.

N/A

Interlocking movable guards shall be designed


in such a way that the absence or failure of
one of their components prevents starting or
stops the hazardous appliance functions.

N/A

Adjustable guards restricting access to those areas of the moving parts strictly
necessary for the work shall be:

----

adjustable manually or automatically,


depending on the type of work involved, and

N/A

readily adjustable without the use of tools.

N/A

22.ZE.6

In case of interruption, re-establishment after


an interruption or fluctuation in whatever
manner of the power supply, the appliance
shall not restart, however automatic restarting
of the operation is allowed if the appliance may
continue to operate, without causing any
hazard to the user, from the same point in its
operating cycle at which the voltage
interruption or fluctuation occurred.

N/A

Annex ZF

Criteria applied for the allocation of products covered by standards in the


EN 60335 series under LVD or MD

Annex ZZ

Coverage of Essential Requirements of EC Directives

P
N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 135 of 139


Appendix to TRF no. IECEN60335_2_40B

Report. No.: GZ12100571-1R3

AMENDMENT 15: 2011 TO EN 60335-1: 2002


Clause

Requirement Test

25

Supply connection and external flexible cords

25.7

Add the following text after the last dash and before
the paragraph regarding "Supply cords for class III
appliances":

N/A

Halogen-free thermoplastic compound sheathed.


Their properties shall be at least those of:

N/A

halogen-free thermoplastic compound sheathed


cords (code designation H03Z1Z1H2-F, H03Z1Z1F), for appliances having a mass not exceeding 3
kg;
halogen-free thermoplastic compound sheathed
cords (code designation H05Z1Z1H2-F or
H05Z1Z1-F), for other appliances;

N/A

Cross-linked halogen-free compound sheathed.

N/A

Their properties shall be at least those of crosslinked halogen-free compound sheathed cords
(code designation H07ZZ-F).
Add the following after EN 50366:

N/A

Annex ZC

Result Remark

Verdict
--

N/A

N/A

EN 50525-3-11
- Electric cables - Low voltage energy cables of
rated voltages up to and including 450/750 V (U0/U)
Part 3-11: Cables with special fire performance Flexible cables with halogen-free thermoplastic
insulation, and low emission of smoke
EN 50525-3-21
- Electric cables - Low voltage energy cables of
rated voltages up to and including 450/750 V
(U0/U) Part 3-21: Cables with special fire
performance - Flexible cables with halogen-free
crosslinked insulation, and low emission of
smoke
Replace footnote 3) by the following:
3) EN 50525 series, which is related to, but not
directly equivalent with the IEC 60227 series,
applies instead.
Replace footnote 4) by the following:
4) EN 50525 series, which is related to, but not
directly equivalent with the IEC 60245 series,
applies instead.

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 136 of 139


Appendix to TRF no. IECEN60335_2_40B

Report. No.: GZ12100571-1R3

AMENDMENT 2:2009 TO EN 60335-2-40:2003


Clause

Requirement Test

MARKING AND INSTRUCTIONS

7.1

(Addition:)

Result Remark

Verdict

N/A

- the maximum operating pressure for the heat


exchanger for hydronic fan coil/air handling
units. (EN 60335-2-40/A2:2009)

11

HEATING

11.2

(Addition:)
except for fan coils where the flow rates and
liquid temperatures shall be the maximum
specified in the manufacturers instructions;
(EN 60335-2-40/A2:2009)

11.8

(Replacement:)

N/A

External enclosure of appliances with or


without supplementary heaters, not exceeding
85C.
(EN 60335-2-40/A2:2009)

15

MOISTURE RESISTANCE

15.1

(Replacement:)
The motor-compressor is not operated and
detachable parts are removed during the tests
of 15.2 and 15.3. (EN 60335-2-40/A2:2009)

15.101

(Addition:)
Spillage test as specified, unless
(EN 60335-2-40/A2:2009)

N/A

The minimum linear dimension of a horizontal


or near horizontal top surface of the cabinet is
75 mm or less. (EN 60335-2-40/A2:2009)

N/A

A unit whose top, when installed, has a height


of greater than 2 m, need not be tested.
(EN 60335-2-40/A2:2009)

19

ABNORMAL OPERATION

19.10.101

(Addition:)

N/A

The test of 19.10 is repeated on class 0I


appliances and class I appliances incorporating
tubular sheathed or embedded heating
elements. (EN 60335-2-40/A2:2009)
However, controls are not short-circuited but
one end of the element is connected to the
sheath of the heating element.

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 137 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result Remark

Verdict

(EN 60335-2-40/A2:2009)

19.14

The test is repeated with the polarity of the


supply to the appliance reversed and with the
other end of the element connected to the
sheath.
(EN 60335-2-40/A2:2009)

N/A

The test is not carried out on appliances


intended to be permanently connected to fixed
wiring and on appliances where an all-pole
disconnection occurs during the test of 19.10.
(EN 60335-2-40/A2:2009)

N/A

(Amendment:)

During the tests of 19.2 to 19.10.101 and


19.11, 19.12 and 19.13 if appropriate, the
appliances shall not emit flames or molten
metal, or poisonous or ignitable gas in
hazardous amounts.
(EN 60335-2-40/A2:2009)
19.101

(Addition:)

N/A

All appliances provided with supplementary


heaters and with free air discharge are
subjected to the specified test in each mode of
operation.
(EN 60335-2-40/A2:2009)
During the test the temperature shall not
exceed 150 C but an overshoot of 25 C is
permitted during the first hour.
(EN 60335-2-40/A2:2009)

N/A

21

MECHANICAL STRENGTH

21.1

(Replacement:)

Safety requirements specified in ISO 5149


shall apply. (EN 60335-2-40/A2:2009)

22

CONSTRUCTION

22.102

(Replacement:)

Appliances provided with supplementary heaters (EN 60335-2-40/A2:2009)


22.102.1

Appliances provided with supplementary


heaters for air shall be provided with at least
two thermal cut-outs (the first one shall be a
self-resetting and the other shall be a non-selfresetting thermal cut-out).
(EN 60335-2-40/A2:2009)

N/A

22.102.2

Appliances provided with supplementary


heaters for water shall incorporate a non-selfresetting thermal cut-out, providing all-pole
disconnection that operates separately from

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 138 of 139


Clause

Requirement Test

Report. No.: GZ12100571-1R3


Result Remark

Verdict

water thermostats.
(EN 60335-2-40/A2:2009)

22.102.3

However, for appliances intended to be


connected to fixed wiring, the neutral
conductor need not be disconnected.
(EN 60335-2-40/A2:2009)

N/A

Thermal cut-outs of the capillary type shall be


so designed that the contacts open in the
event of leakage of the capillary tube
(EN 60335-2-40/A2:2009)

N/A

TRF No.: IECEN60335_2_40B


Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538

Page 139 of 139


Appendix to TRF no, IECEN60335_2_40B

Report. No.: GZ12100571-1R3

IEC 60335-2-65:2002 +A1:2008


EN 60335-2-65:2003 +A1:2008
Clause

Requirement Test

Result Remark

16

LEAKAGE CURRENT AND ELECTRIC STRENGTH

---

16,101

High-voltage transformers must have


adequate internal insulation, The duration of
the test is ,,, sec, (IEC 60335-2-65)

32

RADIATION, TOXICITY AND SIMILAR HAZARDS


The ozone concentration produced by
ionozation is not excessive and shall not
exceed 5 x 10/-8
(IEC/EN 60335-2-65)

Verdict

Certified Plasma Generator:


XS-PL-06

---9

Maximum: 1,22 x 10

---End of Report---

TRF No.: IECEN60335_2_40B