MicroFAST 3.00 FAST Unit

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

6" [8] MIN vent pipe

see note 2 NOTES


1. Airline piping to FAST® may not exceed 100 FT [30m] total
Inspection/ Joints
Pump out must be length and have a maximum of 4 elbows in the piping system.
Ports 6"[15] Inspection watertight For distances greater than 100 FT [30m] consult factory. Blower
see note 3-5 Port /Vent must be located above flood levels on a concrete base 42" X
see notes 2-5 28" X 2" [105 X 70 X 5cm] min.
4" [10] FAST®
effluent pipe 2. Vent to desired location and cover opening with a vent grate
See note 7 with at least 20 sq in. [125 sq. cm] open surface area. Secure
with stainless steel screws. Vent piping must not allow
2"[5] MIN condensate build up or create back pressure. Vent must be
Blower Piping above finished grade or higher (see sheet 4 of 4).
See note 1
6"
15 1/8"±1/8" 3. All appurtenances to FAST® (e.g. tanks, access ports,
4" electrical, etc.) must conform to all applicable country, state,
15.2 38.4±0.3 province, and local plumbing and electrical codes. Pump out
10.2 access shall be adequate to thoroughly clean out both zones.

4. All inspection, viewing and pump out ports must be secured to


prevent accidental or unauthorized access.
39 1/4" MIN 5. Tank, piping, conduit, etc. are provided by others. Blower
100 MIN control system by Bio-Microbics, Inc. See Installation Manual.
Influent 68 1/8" MIN 6. If less than the specified minimums are considered necessary,
waste 173 MIN consult factory for guidance.
See Note 8
7. All piping and ancillary equipment installed after FAST must
not impede nor restrict free flow of effluent.
27" MIN
8. The tank(s) shall be designed to prevent air passage between
69 MIN the settling zone/tank and the treatment zone and preventing
connection an air lock. Examples include a baffle wall sealed to the lid,
between zones and treatment zone inlet line with a pipe cap. Consult factory
for guidance.
Settling Zone 9 3/8"
1500 Gallon MIN [5700L MIN] Treatment Zone 23.8 9. Installations using a FAST® system lid are capable of
2250 Gallon MIN [8500L MIN] withstanding AASHTO H-10 equivalent loads. Any installation in
seen note 6 which a FAST lid is buried deeper than 3 feet, or where
additional loading conditions may occur, a professional
Inspection/ engineer should be consulted. FAST® with feet option should
Pump out port be considered. Refer to Installation Manual for more details.
see notes 3-5
49" 10. Specialized treatment levels may require specific features to
124.5 be incorporated into the design. Consult factory for guidance.
55 3/4" MIN
141.6 MIN
CL
75 3/4" DO NOT SCALE
192.4
UNLESS NOTED
DIMENSIONS
2 1/2" ARE IN INCHES
6.4 [CENTIMETERS]
Opening for FAST® TOLERANCES
module to sit on tank 105 3/4" MIN border for sealing
and securing the lid ± 0.02 IN/IN
268.6 MIN [± 0.05 CM/CM] MicroFAST 3.00 FAST Unit
and the liner to the tank
WEIGHT lb SIZE DRAWING NUMBER

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A MicroFAST® 3.00 with lid SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 12/18/2006 1 OF 4
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-03-Y
6"[8] MIN NOTES
Inspection/ All plumbing and venting 1. Airline piping to FAST® may not exceed 100 FT [30m] total length
Pump out ports vent pipe must use water tight and have a maximum of 4 elbows in the piping system. For
see notes 3-5 see note 2 gaskets must be secured distances greater than 100 FT [30m] consult factory. Blower must
see notes 2-5 be located above flood levels on a concrete base 42" X 28" X 2"
[105 X 70 X 5cm] min.
4" [10] Pipe
Pipe clamp FAST®treated 2. Vent to desired location and cover opening with a vent grate
see note 9 effluent with at least 20 sq in.[125 sq. cm] open surface area. Secure
2"[5] MIN see note 7 with stainless steel screws. Vent piping must not allow
Blower Piping condensate build up or create back pressure. Vent must be
see note 1 above finished grade or higher (see sheet 4 of 4).
6" 3. All appurtenances to FAST® (e.g. tanks, access ports, electrical,
4" 17" MIN see note 11 etc.) must conform to all applicable country, state, province,
15.2 43.1 MIN and local plumbing and electrical codes. Pump out access shall
10.2 be adequate to thoroughly clean out both zones.

4. All inspection, viewing and pump out ports must be secured to


prevent accidental or unauthorized access.

5. Tank, piping, conduit, etc. are provided by others. Blower control


39 1/4" MIN system by Bio-Microbics, Inc. See Installation Manual.
Influent 99.7 MIN
waste 58 3/4"±1/8" 6. If less than the specified minimums are considered necessary,
See 149.2±0.3 consult factory for guidance.
Note 5
7. All piping and ancillary equipment installed after FAST must not
68 1/8" MIN impede nor restrict free flow of effluent.
173.1 MIN 8. The tank(s) shall be designed to prevent air passage between
27" MIN
68.6 MIN the settling zone/tank and the treatment zone and preventing
an air lock. Examples include a baffle wall sealed to the lid or
treatment zone inlet line with a pipe cap. Consult factory for
guidance.
connection between zones 9 3/8" see note 6 & 12 9. The air supply line into the FAST® unit must be secured to prevent
23.9 vibration induced damage. The air supply line should be secured
Settling Zone Treatment Zone with a non-corrosive clamp every 2' min [60 cm]. See alternate
1500 Gallon MIN [5700L MIN] 2250 Gallon MIN [8500L MIN] air supply option on sheet 4 of 4.
Inspection/
Pump out port
see notes 3-5 10. Specialized treatment levels may require specific features to be
incorporated into the design. Consult factory for guidance.

11. Min. height may be reduced, consult factor and reference "Low
27 5/8"±1/2" 41 3/4"±1/2" Profile Module Procedure.pdf"
70.2±1.3 106±1.3
12. Refer to sheet 4 of 4 for leg extensions requirements.
CL
55 3/4" MIN
141.6 MIN
DO NOT SCALE
Opening for FAST® 55 1/4"
module to sit in tank 140.3 UNLESS NOTED
83 1/2" DIMENSIONS
212.1 ARE IN INCHES
[CENTIMETERS]
TOLERANCES
16" MIN ± 0.02 IN/IN
105 3/4" MIN 40.6 MIN MicroFAST 3.00 FAST Unit
[± 0.05 CM/CM]
268.6 MIN
WEIGHT lb SIZE DRAWING NUMBER

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A MicroFAST® 3.00 with feet SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 12/18/2006 2 OF 4
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-03-Y
Specifications for MicroFAST 3.00 Wastewater Treatment System
1. GENERAL
The contractor shall furnish and install (1) MicroFAST® 3.00 treatment system as manufactured by Bio-Microbics, Inc. The treatment system shall be complete with all needed equipment as shown
on the drawings and specified herein.
The principal items of equipment shall include FAST® system insert, leg extensions, or lid, blower assembly, blower controls and alarms. All other items will be provided by others.
The MicroFAST 3.00 unit shall be situated within a 2250 gallon [8500 L] minimum compartment as shown on the drawings. Suggested maximum settling zone is (1X) the daily flow. Tank must provide
adequate pump out access and conform to local, state, and all other applicable codes. The contractor shall provide coordination between the FAST system and tank supplier with regard to
fabrication of the tank, installation of the FAST unit and delivery to the job site.
2. OPERATING CONDITIONS
The MicroFAST 3.00 treatment system shall be capable of treating the wastewater produced by typical family activities (bath, laundry, kitchen, etc.) ranging from (10) ten to
(42) forty-two people and not to exceed 3000 US Gallons per day (11400 LPD) provided the waste contains nothing that will interfere with biological treatment. The FAST system is a biological
treatment system not meant for non-biodegradable or industrial wastewater.
3. MEDIA
The FAST media shall be manufactured of rigid PVC, polyethylene, or polypropylene and it shall be supported by the polyethylene insert. The media shall be fixed in position and contain no
moving or wearing parts and shall not corrode. The media shall be designed and installed to ensure that sloughed solids descend through the media to the bottom of the septic tank.
4. BLOWER
The MicroFAST 3.00 unit shall come equipped with a regenerative type blower capable of delivering 44-85 CFM [68-90 m3/hr] The blower assembly shall include an inlet filter with metal filter
element. Blower piping to the tank shall use non-corrosive material (PVC, Galvanized, or Stainless Steel). Do not run galvanized pipe inside the treatment tank. Refer to Installation Manual for
further details.
5. REMOTE MOUNTED BLOWER
The blower must not set in standing water and its elevation must be higher than the normal flood level. A two-piece, rectangular housing shall be provided. The discharge air line from the blower
to the MicroFAST System, shall be provided and installed by the contractor.
6. ELECTRICAL
The electrical source should be within 150 feet [45 meters] of the blower, consult local codes for longer wiring distances. All wiring must conform to all applicable codes(IEC, NEC, etc.). Wiring
distances must prevent significant voltage loss. Input power on 60Hz electrical systems 220VAC, 1Ø, 10.6 FLA, 220/460VAC, 3Ø, 4.9/2.5 FLA on 50 Hz electrical systems 220VAC, 1Ø, 12 FLA,
230/380VAC, 3Ø, 6.1/3.5 FLA. Other voltages and phase are also available. Actual power consumption varies with site conditions. All conduit and wiring shall be supplied by contractor.
7. CONTROLS
The control panel provides power to the blower with an alarm system consisting of a visual and audible alarm capable of signaling blower circuit failure and high water conditions. The control
panel is equipped with SFR® (Sequencing Fixed Reactor) timed control feature. A manual silence button is included.
8. INSTALLATION AND OPERATING INSTRUCTIONS
All work must be done in accordance with local codes and regulations. Installation of the MicroFAST 3.00 shall be done in accordance with the written instructions provided by the manufacturer.
Manuals shall be furnished, which will include a description of system installation, operation, and maintenance procedures.
9. FLOW AND DOSING
FAST systems have been successfully designed, tested and certified receiving gravity, demand-based influent flow. When influent flow is controlled by pump or other means to help with highly
variable flow conditions, then multiple dosing events should be used to maximize performance. The flow rate shall not exceed 15 gpm (57 Lpm) with a maximum hourly flow not to exceed 10% of
the design daily flow (450 gph (1700LPH)).
10.WARRANTY
Bio-Microbics, Inc. warrants all new MicroFAST® models (MicroFAST® 3.0, 4.5, and 9.0) against defects in materials and workmanship for a period of one year after installation or eighteen (18 months) from the date of
shipment which ever occurs first, subject to the following terms and conditions:. All are subject to the following terms and conditions below:

During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has
been installed and is being operated and maintained in accordance with the written instructions provided by Bio-Microbics, Inc., Bio-Microbics,
Inc. will repair or replace at its discretion such defective parts free of charge. Defective parts must be returned by owner to Bio-Microbics, Inc.’s
factory postage paid, if so requested. The cost of labor and all other expenses resulting from replacement of the defective parts and from
installation of parts furnished under this warranty and regular maintenance items such as filters or bulbs shall be borne by the owner. This warranty
does not cover general system misuse, aerator components which have been damaged by flooding or any components that have been
disassembled by unauthorized persons, improperly installed or damaged due to altered or improper wiring or overload protection. This warranty
applies only to the treatment plant and does not include any of the structure wiring, plumbing, drainage, septic tank or disposal system. DO NOT SCALE
Bio-Microbics, Inc. reserves the right to revise, change or modify the construction and/or design of the FAST system, or any component part
or parts thereof, without incurring any obligation to make such changes or modifications in present equipment. Bio-Microbics, Inc. is not UNLESS NOTED
responsible for consequential or incidental damages of any nature resulting from such things as, but not limited to, defect in design, material, DIMENSIONS
or workmanship, or delays in delivery, replacements or repairs. ARE IN INCHES
[CENTIMETERS]
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED. BIO-MICROBICS SPECIFICALLY DISCLAIMS ANY IMPLIED TOLERANCES
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ± 0.02 IN/IN
[± 0.05 CM/CM] MicroFAST 3.00 FAST Unit
NO REPRESENTATIVE OR PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR TO ASSUME FOR BIO-MICROBICS, INC., ANY
OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. Contact your local distributor for parts and service. WEIGHT lb SIZE DRAWING NUMBER

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A MicroFAST® 3.00 Specifications SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 12/18/2006 3 OF 4
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-03-Y
Minimum leg extension assembly 2 screws per Alternate Air Supply
see note 4 side included 2" Air Supply
Option Line
FAST® Lid Vent Option
Non-corrosive clamp
every 2 feet [0.5m]
NDS 6" Grate MIN 9.5 SQ in [61 Sq cm]
of open surface area
Riser

FAST® Air Lift

16" MIN
40.6 MIN

9 1/8" MIN
23.1 MIN

Non-corrosive clamp Riser


every 2 feet [0.6m]

Fasten with non-


corrosive screws
2" Air
Supply
Line
FAST® Air Lift
DETAIL 2" PVC
SCALE 1 : 4 Coupler
DETAIL
SCALE 1 : 5

Notes
1. Secure leg extension to the FAST® unit by placing two screws on each side of the leg
extension (4 screws per foot are included).
2. Cut 4" schd. 40 PVC pipe (not included) to obtain the desired height. Minimum pipe length of
9 3/8" [24cm]. For heights greater than 18" [45.7cm] use schd. 80 PVC pipe (not included). DO NOT SCALE
Consult factory for extending leg beyond 36"[90cm]. UNLESS NOTED
3. Anchor the leg extensions to the tank with non-corrosive hardware (not included) at the DIMENSIONS
provided mounting points. ARE IN INCHES
4. If less than the specified minimums are considered necessary, consult factory for guidance. [CENTIMETERS]
5. The air supply line into the FAST® unit must be secured to prevent vibration induced damage. TOLERANCES
The air supply line should be secured with a non-corrosive clamp every 2ft [0.6m] minimum. ± 0.02 IN/IN
6. Tank, anchors, piping conduit, blower, housing pad and vents are provided by others. [± 0.05 CM/CM] MicroFAST 3.00 FAST Unit
WEIGHT lb SIZE DRAWING NUMBER

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A MicroFAST® 3.00 Details SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 12/18/2006 4 OF 4
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-03-Y