SAFETY DATA SHEET Version 6.

7
Revision Date 28.03.2021
according to Regulation (EC) No. 1907/2006 Print Date 29.01.2023
GENERIC EU MSDS - NO COUNTRY SPECIFIC DATA - NO OEL DATA

SECTION 1: Identification of the substance/mixture and of the company/undertaking


1.1 Product identifiers
Product name : Aluminum hydroxide
Product Number : 239186
Brand : SIGALD
REACH No. : 01-2119529246-39-XXXX
CAS-No. : 21645-51-2
1.2 Relevant identified uses of the substance or mixture and uses advised against
Identified uses : Laboratory chemicals, Manufacture of substances
1.3 Details of the supplier of the safety data sheet
Company : Sigma-Aldrich Chemie GmbH
Eschenstrasse 5
D-82024 TAUFKIRCHEN
Telephone : +49 (0)89 6513-1130
Fax : +49 (0)89 6513-1161
E-mail address : technischerservice@merckgroup.com
1.4 Emergency telephone
Emergency Phone # : 0800 181 7059 (CHEMTREC Deutschland)
+49 (0)696 43508409 (CHEMTREC
weltweit)

SECTION 2: Hazards identification


2.1 Classification of the substance or mixture
Not a hazardous substance or mixture according to Regulation (EC) No 1272/2008.
2.2 Label elements
Not a hazardous substance or mixture according to Regulation (EC) No 1272/2008.
2.3 Other hazards
This substance/mixture contains no components considered to be either persistent,
bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at
levels of 0.1% or higher.

SIGALD- 239186 Page 1 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada
SECTION 3: Composition/information on ingredients
3.1 Substances
Formula : H3AlO3
Molecular weight : 78,00 g/mol
CAS-No. : 21645-51-2
EC-No. : 244-492-7
No components need to be disclosed according to the applicable regulations.

SECTION 4: First aid measures


4.1 Description of first-aid measures
If inhaled
After inhalation: fresh air.
In case of skin contact
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with
water/ shower.
In case of eye contact
After eye contact: rinse out with plenty of water. Remove contact lenses.
If swallowed
After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling
unwell.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section
2.2) and/or in section 11
4.3 Indication of any immediate medical attention and special treatment needed
No data available

SECTION 5: Firefighting measures


5.1 Extinguishing media
Suitable extinguishing media
Use extinguishing measures that are appropriate to local circumstances and the
surrounding environment.
Unsuitable extinguishing media
For this substance/mixture no limitations of extinguishing agents are given.
5.2 Special hazards arising from the substance or mixture
Aluminum oxide
Not combustible.
Ambient fire may liberate hazardous vapours.
5.3 Advice for firefighters
In the event of fire, wear self-contained breathing apparatus.
5.4 Further information
none

SIGALD- 239186 Page 2 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Advice for non-emergency personnel: Avoid inhalation of dusts. Evacuate the danger
area, observe emergency procedures, consult an expert.
For personal protection see section 8.
6.2 Environmental precautions
No special precautionary measures necessary.
6.3 Methods and materials for containment and cleaning up
Observe possible material restrictions (see sections 7 and 10). Take up dry. Dispose of
properly. Clean up affected area. Avoid generation of dusts.
6.4 Reference to other sections
For disposal see section 13.

SECTION 7: Handling and storage


7.1 Precautions for safe handling
For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
Storage conditions
Tightly closed. Dry.
7.3 Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated

SECTION 8: Exposure controls/personal protection


8.1 Control parameters
Ingredients with workplace control parameters
8.2 Exposure controls

Personal protective equipment

Eye/face protection
Use equipment for eye protection tested and approved under appropriate
government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Skin protection
This recommendation applies only to the product stated in the safety data sheet,
supplied by us and for the designated use. When dissolving in or mixing with other
substances and under conditions deviating from those stated in EN374 please
contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell,
Internet: www.kcl.de).
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: 480 min
Material tested:KCL 741 Dermatril® L
This recommendation applies only to the product stated in the safety data sheet,
supplied by us and for the designated use. When dissolving in or mixing with other
SIGALD- 239186 Page 3 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada
substances and under conditions deviating from those stated in EN374 please
contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell,
Internet: www.kcl.de).
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: 480 min
Material tested:KCL 741 Dermatril® L

Respiratory protection
required when dusts are generated.
Our recommendations on filtering respiratory protection are based on the following
standards: DIN EN 143, DIN 14387 and other accompanying standards relating to
the used respiratory protection system.
Recommended Filter type: Filter type P1
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory
protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Control of environmental exposure
No special precautionary measures necessary.

SECTION 9: Physical and chemical properties


9.1 Information on basic physical and chemical properties
a) Appearance Form: solid
Color: white
b) Odor odorless
c) Odor Threshold Not applicable
d) pH ca.8 - 9 at 100 g/l at 20 °C
(slurry)
e) Melting Melting point: 300 °C - Elimination of water of crystallization
point/freezing point
f) Initial boiling point Not applicable
and boiling range
g) Flash point Not applicable
h) Evaporation rate No data available
i) Flammability (solid, The product is not flammable.
gas)
j) Upper/lower No data available
flammability or
explosive limits
k) Vapor pressure < 0,1 hPa at 20 °C
l) Vapor density No data available
m) Relative density No data available
n) Water solubility at 20 °C - OECD Test Guideline 105insoluble
o) Partition coefficient: Not applicable for inorganic substances
SIGALD- 239186 Page 4 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada
n-octanol/water
p) Autoignition No data available
temperature
q) Decomposition ca.150 - 300 °C -
temperature
r) Viscosity Viscosity, kinematic: No data available
Viscosity, dynamic: No data available
s) Explosive properties No data available
t) Oxidizing properties No data available
9.2 Other safety information
No data available

SECTION 10: Stability and reactivity


10.1 Reactivity
No data available
10.2 Chemical stability
The product is chemically stable under standard ambient conditions (room temperature) .
10.3 Possibility of hazardous reactions
Exothermic reaction with:
Strong acids

10.4 Conditions to avoid


no information available
10.5 Incompatible materials
No data available
10.6 Hazardous decomposition products
In the event of fire: see section 5

SECTION 11: Toxicological information


11.1 Information on toxicological effects
Acute toxicity
LD50 Oral - Rat - female - > 2.000 mg/kg
(OECD Test Guideline 423)

Skin corrosion/irritation
Skin - Rabbit
Result: No skin irritation - 4 h
(OECD Test Guideline 404)
Serious eye damage/eye irritation
Eyes - Rabbit
Result: No eye irritation

SIGALD- 239186 Page 5 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada
(OECD Test Guideline 405)
Respiratory or skin sensitization
Maximization Test - Guinea pig
Result: negative
(OECD Test Guideline 406)

Germ cell mutagenicity

Test Type: In vitro mammalian cell gene mutation test


Test system: Mouse lymphoma test
Metabolic activation: with and without metabolic activation
Method: OECD Test Guideline 476
Result: negative

Test Type: In vivo micronucleus test


Species: Rat
Cell type: Bone marrow
Application Route: Oral
Method: OECD Test Guideline 474
Result: negative

Carcinogenicity
No data available
Reproductive toxicity
No data available

Specific target organ toxicity - single exposure


No data available
Specific target organ toxicity - repeated exposure
No data available
Aspiration hazard
No data available

11.2 Additional Information


RTECS: BD0940000

SECTION 12: Ecological information


12.1 Toxicity
No data available
12.2 Persistence and degradability
The methods for determining the biological degradability are not applicable to inorganic
substances.
12.3 Bioaccumulative potential
No data available

SIGALD- 239186 Page 6 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment
This substance/mixture contains no components considered to be either persistent,
bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at
levels of 0.1% or higher.
12.6 Other adverse effects
No data available

SECTION 13: Disposal considerations


13.1 Waste treatment methods
Product
See www.retrologistik.com for processes regarding the return of chemicals and
containers, or contact us there if you have further questions.

SECTION 14: Transport information


14.1 UN number
ADR/RID: - IMDG: - IATA: -
14.2 UN proper shipping name
ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
14.3 Transport hazard class(es)
ADR/RID: - IMDG: - IATA: -
14.4 Packaging group
ADR/RID: - IMDG: - IATA: -
14.5 Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
14.6 Special precautions for user

Further information
Not classified as dangerous in the meaning of transport regulations.

SECTION 15: Regulatory information


15.1 Safety, health and environmental regulations/legislation specific for the
substance or mixture
This material safety data sheet complies with the requirements of Regulation (EC) No.
1907/2006.
National legislation
Seveso III: Directive 2012/18/EU of the : Not applicable
European Parliament and of the Council on the
control of major-accident hazards involving
dangerous substances.

SIGALD- 239186 Page 7 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada
15.2 Chemical Safety Assessment
For this product a chemical safety assessment was not carried out

SECTION 16: Other information


Further information
The above information is believed to be correct but does not purport to be all inclusive
and shall be used only as a guide. The information in this document is based on the
present state of our knowledge and is applicable to the product with regard to
appropriate safety precautions. It does not represent any guarantee of the properties of
the product. Sigma-Aldrich Corporation and its Affiliates shall not be held liable for any
damage resulting from handling or from contact with the above product. See
www.sigma-aldrich.com and/or the reverse side of invoice or packing slip for additional
terms and conditions of sale.

Copyright 2020 Sigma-Aldrich Co. LLC. License granted to make unlimited paper copies
for internal use only.
The branding on the header and/or footer of this document may temporarily not visually
match the product purchased as we transition our branding. However, all of the
information in the document regarding the product remains unchanged and matches the
product ordered. For further information please contact mlsbranding@sial.com.

SIGALD- 239186 Page 8 of 8

The life science business of Merck operates as MilliporeSigma in


the US and Canada