Technical Data Sheet: ZT 160 STD 8.6 Bar (Atlas Copco) : Product Definition
Technical Data Sheet: ZT 160 STD 8.6 Bar (Atlas Copco) : Product Definition
Technical Data Sheet: ZT 160 STD 8.6 Bar (Atlas Copco) : Product Definition
Product definition
Model ZT 160 STD
Pressure variant 8.6 bar
Integrated dryer Pack
Frequency 60 Hz
Reference conditions
Absolute inlet pressure 1 bar(a)
Relative humidity 0%
Air inlet temperature 20 °C
Cooling air inlet temperature 20 °C
Effective working pressure 7 bar(g)
Performance data*1
Maximum working pressure 8.6 bar(g)
− Free air delivery 421.8 l/s
− Total electrical power input 179.7 kW
− Total specific energy requirements (SER) 426.1 J/l
Effective working pressure 7 bar(g)
− Free air delivery 421.9 l/s
− Total electrical power input 166.3 kW
− Total specific energy requirements (SER) 394.1 J/l
Minimum effective working pressure 4 bar(g)
− Free air delivery 422.1 l/s
− Total electrical power input 141 kW
− Total specific energy requirements (SER) 334 J/l
Unit data*3
Compressed air temperature at outlet 25.8 °C
Mean sound pressure level*2
Total electrical power input at unload 39 kW
Cooling air flow compressor 5.8 m³/s
Cooling air flow motor 0.53 m³/s
Oil capacity 48 l
Limitations
Maximum effective working pressure 8.6 bar(g)
Minimum effective working pressure 4 bar(g)
Maximum ambient temperature 40 °C
Minimum ambient temperature 0 °C
Maximum cooling air temperature 40 °C
Minimum cooling air temperature 0 °C
Maximum altitude (above sea level) 1000 m
Installation connections
Compressed air outlet 3"-150lbs
Condensate drain connections G 1/2"
Electrical cable entry size plate
Electrical data
Supply voltage 460 V
Supply frequency 60 Hz
Package current*4 276.9 A
Starter type Y-D (Star-Delta)
Starting current DOL
Starting current YD 729.9 A
Electrical network TT or TN network
Approvals
Electrical approval CSA-UL
Pressure vessel approval ASME (U Stamp)
Notes
*1 The FAD figures quoted correspond to 'Actual Volume Flow Rate' in accordance with ISO 1217
Ed. 4 (2009), guaranteed with a tolerance of +/-5 % for FAD < 250 l/s (530 cfm) or +/-4 % for FAD >
250 l/s (530 cfm).
FAD (Free Air Delivery) is measured at the above stated reference conditions.
The FAD figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply
voltages > 1kV
*1 The SER figures quoted are in accordance with ISO 1217 Ed. 4 (2009),
guaranteed with a tolerance of +/-6 % for FAD < 250 l/s (530 cfm) or +/-5 % for FAD > 250 l/s (530
cfm).
The SER figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply
voltages > 1kV
*5 The pre-described fuses OR circuit breaker are maximum main fuses or circuit breaker to protect
the installed compressor electrical panel.
Cable and fuse or circuit breaker selection will depend on customer’s installation.
Fuses or circuit breaker of the same type/class are mandatory. Not installing these fuses or circuit
breaker will void warranty in case of an electrical failure.
Installing smaller fuses might lead to smaller supply cables. If Main circuit breaker shown as NA (not
applicable), only fuses are allowed.