CO2-Removal Generon
CO2-Removal Generon
CO2-Removal Generon
CO2 Removal
GENERON® Membrane Technology
Typical Applications
CO2 capture from stack / flue gas Methanol cracking
CO2 removal from bio gas or digester gas H2-PSA purge gas
Syn gas from steam-reforming of natural or Amine plant feed gas purification
bio gas
Skid mounted process units are easy to connect Remote control operation
and commission Operation flexibility with automated part-load
Built to your specifications and convenience Engineering support from concept to
completion
WWW.GENERON.COM 2016
CO2 Removal
GENERON® Membrane Technology
In a typical GENERON® membrane system for CO2 removal the feed gas
is filtered to remove particles and liquid condensate. The feed gas is then
heated to an optimum operation temperature and ready to enter the
GENERON® membrane modules. CO2 gas permeates preferred through
the membrane walls. The non-permeated gas remains at pressure and is
the high heating value product. The “faster” permeating gases, e.g. CO2 ,
H2O, H2S, are collected in the permeate.
GENERON
16250 Tomball Parkway
Houston, Texas 77086
713-937-5200
Sales@Generon.com
Go Direct:GENERON Delivers
WWW.GENERON.COM 2016