PRODUCT NAME – Dr Bio Compostable Polymer

TECHNICAL
DATASHEET PRODUCT CODE – Dr Bio 7212 PLA Filler
Injection and Blow moulding
PRODUCT DESCRIPTION percent (over 1 millions tonnes) of the global
bioplastics production capacities.
Dr. Bio Polymers are the new eco-friendly resins that are made up of
Compostable polymers. The manufactured products using this resin FEATURES
are compostable in normal land fill environment and get disintegrated • Ready to use filler that can be mixed 15-50% in PLA
and decomposed within 4.5 - 6 months as tested by ISO 17088 • Can be processed in all general extruders; monolayer or
multilayer
The Dr Bio Filler 7212 is made of PLA along with Calcium Carbanote and • No special extrusion changes are required in process or
an be converted to bottles, performs, cups, lids, plates and can be
equipment except temperature
thermoformed, injection moulded or blow moulded.
• Fully biodegradable & compostable as per ISO
With a vision to improve the sustainability and anticipating market 17088, DIN EN 13432, ASTM D 6400
trends and future environmental regulations, Hi Tech Group a 38 year • Suitable for all type of conventional blown and
old manufacturer of masterbatches, resins and films has developed a injection moulding plants
new range of renewable and compostable biobased biopolymers: • Giving excellent flexibility and toughness
• Printable and weld able
Our bio polymers are produced from Corn Starch in the agriculture rich
• Suitable for food contact
region of Punjab, India and available in 45 countries globally. Hi Tech
• High melt strength and stable up to 155 degrees
Group’s commitment towards sustainability is oriented to reduce the
greenhouse gasses impact, minimize the dependence on fossil oil C.
derivatives, promote the use of renewable energies and to reduce the • Biodegradation is a chemical process in which materials
plastic waste in the environment. are metabolised to CO2, water, and biomass with the help
of microorganisms.
Problems associated with general polymers • The process of biodegradation depends on the conditions
(e.g. location, temperature, humidity, presence of
n Remains in environment for up to 1000 years
microorganisms, etc.) of the specific environment
n Bio-based, non-biodegradable plastics altogether,
including also the drop-in solutions bio-based PE (industrial composting plant, garden compost, soil, water,
(polyethylene) and bio-based PET (polyethylene etc.) and on the material or application itself.
terephthalate), as well as bio-based PA (polyamides), Consequently, the process and its outcome can vary
currently make up for over 44 percent (almost 1 considerably.
million tonnes) of the global bioplastics production
capacities.
n The production of bio-based PE is predicted to
continue to grow, as new capacities are planned to Applications
come online in Europe in the coming years. Bottles | Plates | Cutlery | Injection and Blow moulding
n Biodegradable plastics altogether, including PLA, PHA,
starch blends and others, account for over 55.5 USAGE
It is a ready to use and since every application is unique
USA - 14310 Gannet St , La Mirada, California
India – Airport Rd, Sahnewal, Ludhiana
18 Sec 6 Manesar, Gurgaon, India
Germany - Schlosserstrasse 13, Lindlar, Germany 51789
Italy - Via dell’Artigianato, 15, Provincia di Modena
info@drbiod.com www.drbiod.com
Page 1 of 3
PRODUCT NAME – Dr Bio Compostable Polymer
TECHNICAL
DATASHEET PRODUCT CODE – Dr Bio 7212 PLA Filler
Injection and Blow moulding
it is recommended for the users to determine the Technical Specifications
applicable usage rate based on their requirements. Dr
Bio 7212 can be processed on conventional extrusion Dr Bio compostable polymer and film has been tested by CIPET
equipment and can be used as neat resin or as part of a
India for ISO 17088 for composability. As the composability of
compound to further optimize overall material
properties. It is recommended to use a general purpose the end product is also dependent on the geometry of
screw with L/D ratios between 24 and 32. Pre-drying of product, it is the responsibility of the manufacturer of the end
the resin is recommended. product to ensure compliance with the regulations.

Property Test Method Value


Startup and shutdown
Colour Visual White
Purge the system with a polyolefin or a purging Specific Gravity of Granules g/cm3 1.4-1.5
compound at its recommended temperature settings.
Melt flow index (ISO 1133-A at 210°C/2.16kg) 8 g/10 min Melt flow index (ISO 1133-
Reset the temperature settings to the recommended A at 210°C/2.16kg)
Melt flow index (ISO 1133-A at 190°C/2.16kg) 3 g/10 min Melt flow index (ISO 1133-
Dr Bio 7277 temperature profile. A at 190°C/2.16kg)
Stereochemical purity 96 (% L-isomer) Stereochemical purity
Purge with the Dr Bio 7277resin until stable processing (Corbion method)
is obtained free of contaminants. Appearance (visual) crystalline white Appearance (visual)
pellets
Reset the temperature settings to the recommended Residual monomer ( max. 0.3 % Residual monomer
(Corbion method)
purging compound temperature profile. Water / moisture (Coulometric Karl-Fisher) max. 400 ppm Water / moisture
(Coulometric Karl-Fisher)
Purge with a polyolefin or a purging compound for 5 Melting temperature Tm (DSC) 155 °C Melting temperature Tm
times the average residence time. (DSC)
PLA Percentage 35%-40%
After completion of the run, Dr Bio 7277must be Calcium Carbonate Percentage 60-65%
removed from the whole system. Dr Bio 7277 can
degrade into lactic acid causing corrosion of the
equipment (e.g die plates). DISPOSAL
Recommendation: Do not allow product to reach sewage
Extruder Temperatures system. Disposal of product or waste must comply with official
local regulations. Packaging that cannot be recycled must be
Feed zone 20-40 °C disposed in the same manner as the product.
Melt zone 140-160 °C
SAFETY INFORMATION
Mixing & conveying 160-170 °C • Keep Out Of Reach Of Children
Die head temperature 170-180 °C • Keep Container Tightly Closed
Typical settings may require optimization • Not For Internal Consumption
• Consult Material Safety Data Sheet For More Information

DECLARATION
This Data sheet and information it contains is considered to be

USA - 14310 Gannet St , La Mirada, California


India – Airport Rd, Sahnewal, Ludhiana
18 Sec 6 Manesar, Gurgaon, India
Germany - Schlosserstrasse 13, Lindlar, Germany 51789
Italy - Via dell’Artigianato, 15, Provincia di Modena
info@drbiod.com www.drbiod.com
Page 2 of 3
PRODUCT NAME – Dr Bio Compostable Polymer
TECHNICAL
DATASHEET PRODUCT CODE – Dr Bio 7212 PLA Filler
Injection and Blow moulding
accurate at the date of printing. No representation or Czech Republic Democratic Republic of the Congo Denmark
warranty, expressed or implied is made as to the accuracy or Ecuador Estonia Finland France Gabon Germany Hungary India
completeness of the data and information contained in this Indonesia Ireland Italy Japan Kazakhstan Korea Latvia Lithuania
Luxembourg Malaysia Mexico Monaco Morocco Nepal
publication. It is the User’s obligation to evaluate and use
Netherlands Nigeria Norway Peru Philippines Poland Portugal
products safely and within the scope advised in the data sheet Republic of Congo Romania Russia Singapore Slovak Republic
and to comply with all applicable laws and regulations. Slovenia South Africa Spain Sri Lanka Sweden Switzerland
Taiwan Thailand Tunisia Turkey Ukraine United Arab Emirates
LIMITED WARRANTY and MENA (Middle East & North Africa) United Kingdom
All statements, technical information and recommendations United States Uruguay Vietnam
contained herein are based on validations and tests conducted
by HI TECH INTERNATIONAL or its partners and are believed to
be reliable, but the accuracy or completeness thereof is not
guaranteed. We warrant our products will be free from defects
when shipped to customer. Our obligation under this warranty
shall be limited to replacement of product that proves to be
defective. To obtain replacement product under this warranty,
the customer must notify Hi Tech International or its partners
or agent of the claimed defect within 1 month after shipment
of product to customer. Customer shall pay all freight charges
for replacement products. We shall have no liability for any
injury, loss or damage arising out of the use of or the inability
to use the products. And any financial claims shall be limited to
the value of the film sold.

Before using, user shall determine the suitability of the


product for its intended use, and user assumes all risk and
liability whatsoever in connection therewith. No
representation or recommendation not contained herein shall
have any force or effect unless in a written document signed
by an officer of the company. The foregoing warranty is DISTRIBUTED BY -
exclusive and in lieu of all other warranties, express, implied or
statutory, including without limitation any implied warranty of
merchantability or of fitness for a particular purpose. In no
case shall HI TECH INTERNATIONAL be liable for incidental or
consequential damages.

GLOBAL SUPPORT
Algeria Angola Argentina Australia Austria Bangladesh Belarus
Belgium Bhutan Bolivia Brazil Canada Chile China Colombia
USA - 14310 Gannet St , La Mirada, California
India – Airport Rd, Sahnewal, Ludhiana
18 Sec 6 Manesar, Gurgaon, India
Germany - Schlosserstrasse 13, Lindlar, Germany 51789
Italy - Via dell’Artigianato, 15, Provincia di Modena
info@drbiod.com www.drbiod.com
Page 3 of 3

You might also like