Nothing Special   »   [go: up one dir, main page]

PHG-2081Pro Industrial PH Meter & Sensor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Shanghai BOQU Instrument Co.

,Ltd Contact: Jori Liu


Website: www.boquinstruments.com Mobile: + 86 17507082182

PHG-2081Pro Industrial PH&ORP Meter


Built-in A/D conversion module, compatible with a variety of analog signal electrodes. Complete functions, stable

performance, easy operation, low power consumption, safety and reliability are the outstanding advantages of this

instrument. This instrument is equipped with RS485 transmission interface, which can be connected to the host

computer through ModbusRTU protocol to realize monitoring and recording. It can be widely used in industrial

occasions such as thermal power generation, chemical industry, metallurgy, environmental protection,

pharmaceutical, biochemical, food and tap water.


Technical Index

Functions pH ORP
Measuring range -2.00pH to +16.00 pH -2000mV to +2000mV
Resolution 0.01pH 1mV
Accuracy ±0.01pH ±1mV
Temp. compensation Pt 1000/NTC10K
Temp. range -10.0 to +130.0℃
Temp. compensation range -10.0 to +130.0℃
Temp. accuracy ±0.5℃
Display Back light, dot matrix
pH/ORP current output1 Isolated, 4 to 20mA output , max. load 500Ω
Temp. current output 2 Isolated, 4 to 20mA output , max. load 500Ω
Current output accuracy ±0.05 mA
RS485 Mod bus RTU protocol
Baud rate 9600/19200/38400
Maximum relay contacts capacity 5A/250VAC,5A/30VDC
Language selection English/ Chinese
Waterproof grade IP65
Power supply From 90 to 260 VAC, power consumption < 4 watts, 50/60Hz
Material ABS
Installation panel/wall/pipe installation
Size/Weight 144mm×144mm×104mm, 0.9Kg
Shanghai BOQU Instrument Co.,Ltd Contact: Jori Liu
Website: www.boquinstruments.com Mobile: + 86 17507082182

PH8012 Industrial Composite Sewage PH Sensor

Basic Principle of pH Electrode


In PH measurement, the used electrode is also known as the primary battery. The primary battery is a system,
whose role is to transfer chemical energy into electrical energy. The voltage of the battery is called the
electromotive force (EMF). This electromotive force (EMF) is composed of two half-batteries. One half-battery is
called the measuring electrode, and its potential is related to the specific ion activity; the other half-battery is the
reference battery, often called the reference electrode, which is generally interlinked with the measurement solution,
and connected to the measuring instrument.

Model No.: PH8012


Measuring range: 0-14pH
Temperature range:0-60℃
Compressive strength:0.6MPa
Slope: ≥96%
Zero point potential: E0=7PH±0.3
Internal impedance: 150-250 MΩ (25℃)
Profile: 3-in-1Electrode (Integrating the temperature compensation and the solution grounding)
Installation size: Upper and Lower 3/4NPT Pipe Thread
Connection: Low-noise cable goes out directly.
Application: Applicable to various industrial sewages, environmental protection and water treatment.

Features of PH Electrode
●It adopts the world-class solid dielectric and a large area of PTFE liquid for junction, non-block and easy
maintenance.
● Long-distance reference diffusion channel greatly extends the service life of electrodes in the harsh environment
● It adopts PPS/PC casing and the upper and lower 3/4NPT pipe thread, so it is easy for installation and there is
no need of the jacket, thus saving the installation cost.
● The electrode adopts the high-quality low-noise cable, which makes the signal output length more than 20
meters free of interference.
● There is no need for additional dielectric and there is a little amount of maintenance.
● High measurement accuracy, fast responsing and good repeatability.
● Reference electrode with silver ions Ag/AgCL

● Proper operation shall make service life longer.

● It can be installed in the reaction tank or pipe laterally or vertically.

● The electrode can be replaced by a similar electrode made by any other country.

Electrode Structure Chart Electrode Wiring Plug

BNC (Q9) Plug Pin Y Plate

You might also like