The following are corrections to errors identified in the specification. Note that this
information is updated regularly as needed therefore the user is encouraged to check this file on
a regular basis for additional corrections. Any errors or questions concerning the specification
should be directed to spec_questions@fordemc.com.
Corrections are shown in red.
Ø Page 34, Table 11-1: Error in Equation for magnetic field limits from 340 – 10,000 Hz.
The corrected equation is:
Ø Page 46, Figure 14-4: Transient voltage level UP (60 volts) is incorrect. The correct value
for UP is 73.5 volts.
Ø Page 87, Figure G-3: The frequency of the function generator stated in the reference key
should be 0.2 Hz, not (0.1 – 20Hz). The timing diagram, however, is correct.
Key:
1 Vehicle Battery Connection
3a Function Generator (0.2 Hz square wave)
3b Resistor: 51 ohms .25 watt
3c 12 volt AC Relay: Potter & Brumfield KUP-14A15-12 (1)
3e NPN Transistor: TIP 41
3e Zener Diode: 39V, 5W (1N5366A)
3f Test Switch: SPST Switch
1 Critical Component: No substitutions permitted without
written authorization from the FMC EMC department. See
Annex H. Relay should be replace after 100 hours of usage
Ø Page 87, Figure G-4: The relay circuit illustrated in Figure G-4 will not function properly
for products with high capacitance circuits. This issue may be corrected by using the
circuit shown below. The same Potter & Brumfield is used.
12 V
A
3
3c NC NC
B
Ø Page 82, Test Pulse B2: Typo in paragraph description of Test Pulse B2. Corrected
paragraph:
Test Pulse B2
Test pulse B1 simulates the voltage transient produced due to low-side switch-off of a
low current (< 0.4 ampere) inductive load. Only control circuits are exposed to this test
pulse. Pulse B2, has similar characteristics as Pulse A2 except with opposite polarity.
Ø Page 25, paragraph 9.3: Test procedure steps are mistyped. Steps e) and f) should be
labeled as steps g) and h).