S Series Installation Guide en
S Series Installation Guide en
S Series Installation Guide en
YeastarInstallation_Guide
S-Series VoIP PBX
1.0
December 4, 2019
Contents
Installation Guide...................................................................................................................................................... 3
Hardware Overview..............................................................................................................................................3
S412 Overview..............................................................................................................................................3
S20 Overview................................................................................................................................................5
S50 Overview................................................................................................................................................8
S100 Overview............................................................................................................................................10
S300 Overview............................................................................................................................................12
Expansion Board.........................................................................................................................................15
Install PBX..........................................................................................................................................................16
Installation Warnings...................................................................................................................................16
Package Contents.......................................................................................................................................16
Hardware Overview
S412 Overview
Front Panel
Blinking In communication.
Off Off-line.
Blinking In communication.
Off Off-line.
Installation_Guide | 1 - Installation Guide | 4
Rear Panel
Installation_Guide | 1 - Installation Guide | 5
Port Description
RJ11 • FXO port (red light): For the connection of PSTN lines or FXS ports of
(Line port) traditional PBX.
• BRI port (orange light): For the connection of ISDN BRI lines.
RJ11 • FXS port (green light): For the connection of analog phones.
(FXS port)
Note: The sequence number of the ports corresponds to that of the
Indicator lights in the front panel. (I.e. the LED lights in the front indicate the
connection status of the corresponding ports at the back panel.)
WAN/LAN Yeastar S412 provides two 10/100Mbps adaptive RJ45 Ethernet ports, and supports
3 Ethernet modes. The default mode is “Single”.
• Single: LAN port will be used for uplink connection. WAN port is disabled.
• Bridge: LAN port will be used for uplink connection. WAN port will be used as
bridge for PC connection.
• Dual: Both LAN and WAN ports can be used for uplink connection.
Reset Button Press and hold for 10 seconds to restore the factory defaults.
S20 Overview
Front Panel
Installation_Guide | 1 - Installation Guide | 6
Off Off-line.
Off Off-line.
Rear Panel
Port Description
RJ11 • FXO port (red light): For the connection of PSTN lines or FXS ports of
traditional PBX.
• FXS port (green light): For the connection of analog phones.
• BRI port (orange light): For the connection of ISDN BRI lines.
WAN/LAN Yeastar S20 provides two 10/100Mbps adaptive RJ45 Ethernet ports, and supports
3 Ethernet modes. The default mode is “Single”.
• Single: LAN port will be used for uplink connection. WAN port is disabled.
• Bridge: LAN port will be used for uplink connection. WAN port will be used as
bridge for PC connection.
• Dual: Both LAN and WAN ports can be used for uplink connection.
Reset Button Press and hold for 10 seconds to restore the factory defaults.
S50 Overview
Front Panel
Port Description
WAN/LAN Yeastar S50 provides two 10/100/1000Mbps adaptive RJ45 Ethernet ports, and
supports 3 Ethernet modes. The default mode is “Single”.
• Single: LAN port will be used for uplink connection. WAN port is disabled.
• Bridge: LAN port will be used for uplink connection. WAN port will be used as
bridge for PC connection.
• Dual: Both LAN and WAN ports can be used for uplink connection.
1-8 Port • FXO port(red light): For the connection of PSTN lines or FXS ports of traditional
(RJ11 port) PBX.
• FXS port (green light): For the connection of analog phones.
• BRI port (orange light): For the connection of ISDN BRI lines.
Reset button Press and hold for 10 seconds to restore the factory defaults.
Rear Panel
Port Description
Port Description
Protective Connect to the ground to reduce the risk of electrocution to the user or protect the
Earth PBX from the bad effects of external noise in the case of a lightning strike.
S100 Overview
Front Panel (1*EX30 + 1*EX08)
Port Description
1-8 Port • FXO port (red light): For the connection of PSTN lines or FXS ports of
(RJ11 port) traditional PBX.
• FXS port (green light): For the connection of analog phones.
• BRI port (orange light): For the connection of ISDN BRI lines.
Port Description
Rear Panel
Port Description
WAN/LAN Yeastar S100 provides two 10/100/1000Mbps adaptive RJ45 Ethernet ports, and
supports 3 Ethernet modes. The default mode is “Single”.
• Single: LAN port will be used for uplink connection. WAN port is disabled.
• Bridge: LAN port will be used for uplink connection. WAN port will be used as
bridge for PC connection.
• Dual: Both LAN and WAN ports can be used for uplink connection.
Installation_Guide | 1 - Installation Guide | 12
Reset button Press and hold for 10 seconds to restore the factory defaults.
Protective Connect to the ground to reduce the risk of electrocution to the user or protect the
Earth PBX from the bad effects of external noise in the case of a lightning strike.
S300 Overview
Front Panel (1*EX30 + 2*EX08)
Port Description
Port Description
1-8 Port • FXO port (red light): For the connection of PSTN lines or FXS ports of traditional
(RJ11 port) PBX.
• FXS port (green light): For the connection of analog phones.
• BRI port (orange light): For the connection of ISDN BRI lines.
Rear Panel
Port Description
WAN/LAN Yeastar S300 provides two 10/100/1000Mbps adaptive RJ45 Ethernet ports, and
supports 3 Ethernet modes. The default mode is “Single”.
• Single: LAN port will be used for uplink connection. WAN port is disabled.
• Bridge: LAN port will be used for uplink connection. WAN port will be used as
bridge for PC connection.
• Dual: Both LAN and WAN ports can be used for uplink connection.
Reset button Press and hold for 10 seconds to restore the factory defaults.
Protective Connect to the ground to reduce the risk of electrocution to the user or protect the
Earth PBX from the bad effects of external noise in the case of a lightning strike.
Expansion Board
Yeastar S100 and S300 are expandable.
• S100 supports up to 2 EX08/EX30 Expansion Boards; supports 1 D30 Module.
• S300 supports up to 3 EX08/EX30 Expansion Boards; supports up to 2 D30 Modules.
EX08 Expansion Board
EX08 board supports up to 4 modules (8 RJ11 ports).
D30 Module
D30 is a DSP module, used to expand the capacity of PBX. With a D30 module added, the extensions increase
100 and concurrent calls increase 30 additionally.
Install PBX
Installation Warnings
To avoid unexpected accident, personal injury or device damage, read the safety disclaimers and installation
warnings.
Power Safety
• Use only the power cord or power adapter provided with the PBX.
• Keep the power off during the installation.
• Make sure that the supply voltage matches the specifications indicated on the back panel of the device.
• To avoid the electric accident, do not open or remove the cover of PBX when it is working as well as off the
power.
• Before cleaning the device, cut off the power supply.
Environment
Install the PBX in a location that is clean, free from vibration, electric shock, and temperature/humidity extremes.
The operating temperature should be kept below 104°F (40°C).
Package Contents
Before you begin to install the PBX, check the package contents. If there is any problem, contact your provider.
Installation_Guide | 1 - Installation Guide | 17
Note: Before installing the module, check if the module is clean and intact.
1. Loosen the screws at the bottom of the device and remove the upper cover.
5. Rotate the antenna into the Antenna Socket. Skip this step if no GSM/3G/4G module installed.
Installation_Guide | 1 - Installation Guide | 20
Desktop Installation
Caution:
• Set 5~10cm gaps around the device for air circulation.
• Avoid any heavy thing placed on the device.
Note: Before installing the module, check if the module is clean and intact.
Installation_Guide | 1 - Installation Guide | 21
1. Loosen the screws at the bottom of the device and remove the upper cover.
5. Rotate the antenna into the Antenna Socket. Skip this step if no GSM/3G/4G module installed.
Desktop Installation
Caution:
• Set 5~10cm gaps around the device for air circulation.
• Avoid any heavy thing placed on the device.
Rack Installation
Caution:
• Be careful not to drop any components. Dropping components may damage them or cause an injury.
• Only use the 19-inch rack mounting kits (attached bracket and fittings) included with the PBX.
1. Fix the brackets to the left and right sides of the PBX with 4 screws.
2. Place the PBX in the 19-inch rack and fix both brackets to the rack with the rack’s proprietary mounting
equipment.
Installation_Guide | 1 - Installation Guide | 24
Ground Connection
Caution:
• Proper grounding (connection to ground) is very important to reduce the risk of electrocution to the
user or protect the PBX from the bad effects of external noise in the case of a lightning strike.
• A permanent connection between ground and the ground terminal of the PBX must be made.
1. Tighten the provided screw stud into the Grounding port on PBX.
2. Insert an 18AWG grounding wire (user supplied).
3. Tighten the provided screw nut.
4. Attach the grounding wire to the grounding terminal.
Note: Before installing the module, check if the module is clean and intact.
1. Loosen the screws at the bottom of the device and remove the upper cover.
Installation_Guide | 1 - Installation Guide | 25
2. Push out the empty board from the inside of the device.
8. Rotate the antenna into the Antenna Socket. Skip this step if no GSM/3G/4G module installed.
Desktop Installation
Caution:
• Set 5~10cm gaps around the device for air circulation.
• Avoid any heavy thing placed on the device.
Rack Installation
Caution:
• Be careful not to drop any components. Dropping components may damage them or cause an injury.
• Only use the 19-inch rack mounting kits (attached bracket and fittings) included with the PBX.
1. Fix the brackets to the left and right sides of the PBX with 4 screws.
Installation_Guide | 1 - Installation Guide | 29
2. Place the PBX in the 19-inch rack and fix both brackets to the rack with the rack’s proprietary mounting
equipment.
Ground Connection
Caution:
• Proper grounding (connection to ground) is very important to reduce the risk of electrocution to the
user or protect the PBX from the bad effects of external noise in the case of a lightning strike.
• A permanent connection between ground and the ground terminal of the PBX must be made.
1. Tighten the provided screw stud into the Grounding port on PBX.
2. Insert an 18AWG grounding wire (user supplied).
3. Tighten the provided screw nut.
4. Attach the grounding wire to the grounding terminal.
Installation_Guide | 1 - Installation Guide | 30
Note: Before installing the module, check if the module is clean and intact.
1. Loosen the screws at the bottom of the device and remove the upper cover.
2. Push out the empty board from the inside of the device.
Installation_Guide | 1 - Installation Guide | 31
Desktop Installation
Caution:
• Set 5~10cm gaps around the device for air circulation.
• Avoid any heavy thing placed on the device.
Rack Installation
Caution:
• Be careful not to drop any components. Dropping components may damage them or cause an injury.
• Only use the 19-inch rack mounting kits (attached bracket and fittings) included with the PBX.
1. Fix the brackets to the left and right sides of the PBX with 4 screws.
Installation_Guide | 1 - Installation Guide | 35
2. Place the PBX in the 19-inch rack and fix both brackets to the rack with the rack’s proprietary mounting
equipment.
Ground Connection
Caution:
• Proper grounding (connection to ground) is very important to reduce the risk of electrocution to the
user or protect the PBX from the bad effects of external noise in the case of a lightning strike.
• A permanent connection between ground and the ground terminal of the PBX must be made.
1. Tighten the provided screw stud into the Grounding port on PBX.
2. Insert an 18AWG grounding wire (user supplied).
3. Tighten the provided screw nut.
4. Attach the grounding wire to the grounding terminal.
Installation_Guide | 1 - Installation Guide | 36
Note: Before installing the module, check if the module is clean and intact.
1. Loosen the screws at the bottom of the device and remove the upper cover.
Desktop Installation
Caution:
• Set 5~10cm gaps around the device for air circulation.
• Avoid any heavy thing placed on the device.
Note: Connect BRI/PSTN/analog phone/fax machine to the corresponding port based on the
color of port indicator.
FXO
Connect an RJ11 cable to the FXO port. Connect the other end to a PSTN line.
BRI
Connect one end of the cable provided by the ISDN BRI provider to the BRI port. Connect the other end to the equipment of
ISDN provider.
E1/T1/J1 Operation
Port
E1/T1/J1
For S100 and S300
• Connect one end of the E1 cable to the E1/T1 port. Connect the other end to the E1 Provider’s equipment.