Fire Pro Quotation
Fire Pro Quotation
Fire Pro Quotation
Sir,
We Are Pleased To Submit our Proposal And Price Quotation for Labor and Supervision of Automatic
Fire Protection Sprinkler System and Fire Detection Alarm system for Eight Storey UP Faculty Center
and Parking Bldg, Located at Roxas Avenue, cor. Roces St. Old Faculty Bulding, UP Diliman,
Commonwealth Avenue, Quezon City in the Amount of FIVE MILLION EIGHT HUNDRED
SEVENTY FOUR THOUSAND TWO HUNDRED EIGHTY PESOS ONLY. PHP. 5,874,280.00
(VAT INCLUSIVE)
SCOPE OF WORK :
1. Installation of Riser Bi. Pipe 150mm. Schedule 40 Standard welded with Complete fittings from
Lower ground to Roof deck floor. Php. 265,298.00
2. Installation of Fire hose cabinet with Complete accessories, from Lower ground to Eight floor.
Php. 137,500.00
3. Installation of Fire pump and Jockey pump with Controller, Alarm check valve, Prv.
Php. 80,000.00
4. Installation of Feedmain line with Complete Gate vale and Accessories from Lower ground to
Eight floor. Php. 639,145.00
5. Installation of Floor Supervisory Control vale, Drain valve, Gate valve, Sight glass, Pressure
gauge, Check valve, Inspector test connection from Lower ground to Eight floor.
6. Php. 130,147.00
7. Installation of Branch line and Pipe supports, Hangers, Brackets, Fabrication of Structural Steel
way Braces from Lower ground to Eight floor. Php.2,484,800.00
9. Hydrautesting of Riser, Feedmain, Branch line, Dry stand pipe from Lower ground to Roof deck
Php. 130,860.00
10. Installation of Dry Stand Pipe, Fire Hose valve with Cap and Chain, Fire truck inlet connection
from Lower ground to Roof deck. Php. 276,180.00
11. Installation of Smoke Detector, Imc Pipe, Conduit, Fittings, and Pull Boxes from Lower ground
to Eight floor. Php. 573,580.00
12. Installation of Manual Call Point with Strobe Sounder from Lower ground to Eight floor.
Php. 112,000.00
13. Installation of Fire Protection Control Panel and annunciator, Addressable module from Lower
ground to Eight floor. Php. 375,800.00
14. Installation of Wires, Cable into Conduit and Wiring Devices from Lower ground to Eight floor.
Php. 588,970.00
15. Testing and Commissioning from Lower ground to Eight floor. Php. 80,000.00
I. To provide engineering and documentations, supply of tools and equipment, labor and
supervision for the installation of Fire Protection Sprinkler System and Fire detection alarm
system (FDAS) for M.E. SICAT INC.,and other associated services necessary for the
completion and testing of the proposed project in accordance with Technical Specifications
and the following codes and standards:
III. COMPLETION
The Supply and Installation of Fire Protection Sprinkler System shall be completed within Three
Hundred (300) Calendar days, provided with a free and uninterrupted access to all working areas
involved for all VISKEN CONSTRUCTION & TRADING employees.