Milegate Cables: User Manual
Milegate Cables: User Manual
Milegate Cables: User Manual
MileGate Cables
MileGate R3
MileGate
MileGate Cables User Manual
Copyright and Confidentiality Copyright in this document vests in KEYMILE. This document contains confi-
dential information which is the property of KEYMILE. It must be held in con-
fidence by the recipient and may not be used for any purposes except those
specifically authorised by contract or otherwise in writing by KEYMILE. This
document may not be copied in whole or in part, or any of its contents dis-
closed by the recipient to any third party, without the prior written agreement
of KEYMILE.
Disclaimer KEYMILE has taken reasonable care in compiling this document, however
KEYMILE accepts no liability whatsoever for any error or omission in the
information contained herein and gives no other warranty or undertaking as
to its accuracy.
KEYMILE reserves the right to amend this document at any time without
prior notice.
Published by KEYMILE
http://www.keymile.com
The product meets the rules of the conformity declaration at operational con-
ditions that can be considered as normal use.
© 2012 KEYMILE
User Manual
MileGate Cables
1 Preface 5
1.1 Precautions and safety 5
1.1.1 Imminent danger to optical fibre 5
1.1.2 Safety Advice as equipment is connected to hazardous voltages 5
1.1.3 Imminent danger to equipment connected to cables 6
2 Introduction 8
2.1 Earthing principles 8
2.2 Ethernet cables 9
3 Cable finder 10
3.1 Cable types sorted by unit 10
3.2 Cables sorted by order number 13
3.3 Cable types sorted by Cable PEC 16
4 Reference of cables 18
4.1 MileGate 25xx Power cable 0.4m, crimp type socket to cage clamp
(675.0426.00) 18
4.2 Cable 16 pairs, DIN 41612 to open end (675.0494.00) 19
4.3 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 22
4.4 Combo Solution 32 pairs Y-cable, DIN 41612 to open end (675.0432.00) 25
4.5 Combo Solution 48 pairs Y-cable, 2 x DIN 41612 to open end
(675.0434.00) 28
4.6 Combo Solution 64 pairs Y-cable, 2 * DIN 41612 double plug to
open end (675.0488.00) 31
4.7 Combo Solution 48 pairs Y-cable, 3 * DIN 41612 plug to LEA 48 port
splitter (675.0466.00) 35
4.8 Cable 48 pairs, DIN 41612 to open end (675.0435.00) 38
4.9 Cable 64 pairs, DIN 41612 double plug to open end (675.0487.00) 41
4.10 Cable for shelf splitter, CHAMP to open end (675.0440.00) 45
4.11 Cable 48 pairs open end to splitter (675.0441.00) 48
4.12 Cable 32 pairs to shelf splitter, DIN 41612 to CHAMP (675.0450.00) 51
4.13 COGE1 T3 SYNC cable, D-SUB 9 pins to open end (675.0460.00) 55
4.14 Ethernet GbE cat5e, RJ45 plug to RJ45 plug (675.0461.00) 56
4.15 Ethernet GbE cat5e, RJ45 plug to RJ45 plug thin (675.0467.00) 57
4.16 Cable 48 pairs unit to splitter (675.0465.00) 58
4.17 Adapter for 2 x SUIx to shelf splitter, 2 x DIN 41612 to 64-pin CHAMP
(675.0470.00) 61
4.18 MileGate 25xx Power Supply cable, crimp type socket to open end
(675.0471.03) 65
4.19 Adapter 2x16 pairs DIN 41612 to 1x32 pairs DIN male (675.0472.01) 66
4.20 8 x 2 Mbit/s cable 120 ohms, DIN 41612 to open end (A21A6088) 67
4.21 8 pair xDSL cable, DIN 41612 to open end (A21A8448) 70
4.22 8 x 2 Mbit/s cable 75 ohms, DIN 41612 to open end (A21A9151) 72
4.23 Cable G.703 / 75 ohms, DIN 41612 to open end (A31A1167) 74
4.24 Cable G.703 / 75 ohms, DIN 41612 to BNC (A31A1166) 75
4.25 Generic USB cable, USB mini-B to USB A 76
4.26 Optical Cable SM 9/125 duplex, LC to E2000 8° straight 77
4.27 Optical Cable MM 50/125 duplex, LC to SC straight 78
4.28 Optical Cable SM 9/125 duplex, LC to SC straight 79
4.29 Optical Cable SU to ODF SM 9/125 simplex, LC APC with
45° boot to SC APC 80
4.30 Optical Cable optical amplifier to SU SM 9/125 simplex, LC APC
with 45° boot to LC APC with 45° boot 81
4.31 Optical Cable SU to ODF SM 9/125 simplex, LC PC 0°
with 45° boot to SC 82
4.32 Optical Cable SFP with LC-PC duplex to LC-PC duplex 83
4.33 Cable RS485 to open end (A30A1263) 84
4.34 V.35 to Winchester connector (A30A1260) 85
4.35 V.24/V.28 to D-Sub25 connector (A30A1259) 88
4.36 X.24/V.11 to open end (A30A1262) 90
4.37 X.24/V.11 to D-Sub15 connector (A30A1261) 91
4.38 DATAx universal (all pins connected) to open end (A30A2446) 93
4.39 E&M voice interface cable, 8 channels, 8x8 wires, open end
(675.0457.00) 95
1 Preface
Before you handle any cables you must comply with the following safety
advice:
Hazardous voltages
Cables may be connected to mains.
-> Connect the subrack only to a switchable power supply and switch off
the power supply before installation or deinstallaition of the unit.
Hazardous voltages
In operation a MileGate subracks is supplied with potentially hazardous volt-
ages of more than 220 Volts AC.
-> Connect the housing to earth.
-> Connect the protective earth contact of the housing with the protective
earth of the mains cable.
-> Connect the subracks only to a switchable power supply and switch off
the power supply before manipulating.
Danger of electrostatic discharge
To protect your equipment you must discharge any static charge from
your person before touching the unit or any components.
-> Wear a grounded, anti-ESD wristband when working with the hardware.
You find MileGate technical information and the description of the commis-
sioning procedures and operation as follows:
2 Introduction
This document describes electrical cables for MileGate equipment. Electrical
cables for MileGate are specially tailored to offer the best fit for an apllication
Optical cables are not mentioned in this manual as they are architecture and
functions of units of the type KEYMILE relies on fibres which are available in
the open market.
Unless otherwise specified cables are suitable for subracks of the following
types:
• MileGate 2500
• MileGate 2510
• MileGate 2300
• MileGate 2310.
Electrical cables for MileGate Ethernet interfaces must be earthed like any
other cable for MileGate equipment.
KEYMILE provides category 5e Ethernet cables (see "Ethernet GbE cat5e,
RJ45 plug to RJ45 plug (675.0461.00)" (page 56)). The EMC shield is
already exposed to fit the earthing facilities of MileGate 2500 or MileGate
2510 subracks. The purpose of these cables is the provisioning of proper
Ethernet cable shield grounding for the MileGate Ethernet interface and the
application of these cables is normally limited to the connection of MileGate
equipment to the local Ethernet patch panel or to other local equipment such
as switches etc.
For GbE speeds on electrical category 5e cables the maximum distance
between a MileGate subrack and the terminating Ethernet interface (e.g. in
another MileGate subrack) must not exceed to 100 m.
For longer distances KEYMILE recommends the usage of optical Ethernet
interfaces and optical fibres.
3 Cable finder
Find a cable in one of the following lists:
• "Cable types sorted by unit" (page 10),
• "Cables sorted by order number" (page 13).
• "Cable types sorted by Cable PEC" (page 16).
All cables are referenced in "Reference of cables" (page 18).
Cables are sorted by order number in ascending order. The column Refer-
ence links to the cable description in "Reference of cables" (page 18).
Table 2: Cables sorted by order number (section 1 of 3)
Order No Cable Type (Cable PEC) Length Reference
37543008 E&M voice interface cable, 8 channels, 8x8 wires, open end (675.0457.00) 5m page 95
37543016 E&M voice interface cable, 8 channels, 8x8 wires, open end (675.0457.00) 10 m page 95
37543024 E&M voice interface cable, 8 channels, 8x8 wires, open end (675.0457.00) 20 m page 95
37543091 E&M voice interface cable, 8 channels, 8x8 wires, open end (675.0457.00) 3m page 95
37543105 E&M voice interface cable, 8 channels, 8x8 wires, open end (675.0457.00) 15 m page 95
37960157 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 85 m page 22
37971140 Cable for shelf splitter, CHAMP to open end (675.0440.00) 5m page 45
37971158 Cable for shelf splitter, CHAMP to open end (675.0440.00) 3m page 45
37971166 Cable for shelf splitter, CHAMP to open end (675.0440.00) 10 m page 45
37971174 Cable for shelf splitter, CHAMP to open end (675.0440.00) 15 m page 45
37971182 Cable for shelf splitter, CHAMP to open end (675.0440.00) 20 m page 45
37971190 Cable for shelf splitter, CHAMP to open end (675.0440.00) 30 m page 45
37980009 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 5m page 22
37980017 Cable 32 pairs to shelf splitter, DIN 41612 to CHAMP (675.0450.00) 5m page 51
37980025 Generic USB cable, USB mini-B to USB A 5m page 76
37980033 Ethernet GbE cat5e, RJ45 plug to RJ45 plug (675.0461.00) 5m page 56
37980041 Optical Cable MM 50/125 duplex, LC to SC straight 5m page 78
37980068 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 3m page 22
37980050 Optical Cable SM 9/125 duplex, LC to SC straight 5m page 79
37980076 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 10 m page 22
37980084 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 15 m page 22
37980092 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 20 m page 22
37980106 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 30 m page 22
37980114 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 40 m page 22
37980122 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 50 m page 22
37980130 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 60 m page 22
37980149 Cable 32 pairs, DIN 41612 to open end (675.0430.00) 70 m page 22
37980165 Cable 32 pairs to shelf splitter, DIN 41612 to CHAMP (675.0450.00) 3m page 51
37980173 Cable 32 pairs to shelf splitter, DIN 41612 to CHAMP (675.0450.00) 10 m page 51
37980181 COGE1 T3 SYNC cable, D-SUB 9 pins to open end (675.0460.00) 5m page 55
37980190 Optical Cable SM 9/125 duplex, LC to E2000 8° straight 5m page 77
37980211 Combo Solution 32 pairs Y-cable, DIN 41612 to open end (675.0432.00) 5m page 25
37980220 Adapter for 2 x SUIx to shelf splitter, 2 x DIN 41612 to 64-pin CHAMP 5m page 61
(675.0470.00)
37980238 Adapter for 2 x SUIx to shelf splitter, 2 x DIN 41612 to 64-pin CHAMP 2m page 61
(675.0470.00)
37980254 MileGate 25xx Power Supply cable, crimp type socket to open end (675.0471.03) 3m page 65
37980262 Adapter 2x16 pairs DIN 41612 to 1x32 pairs DIN male (675.0472.01) 1m page 66
37980289 Cable 32 pairs to shelf splitter, DIN 41612 to CHAMP (675.0450.00) 2m page 51
37980319 Combo Solution 48 pairs Y-cable, 2 x DIN 41612 to open end (675.0434.00) 5m page 28
The Cable PEC is an internal identifier that is also used in other manuals to
identify the cable type.
Optical cables do not have a PEC.
The column Reference relates to the cable description in "Reference of
cables" (page 18).
Table 3: Cable types sorted by Cable PEC (section 1 of 2)
Id Cable Type Reference
675.0426.00 MileGate 25xx Power cable 0.4m, crimp type socket to cage clamp (675.0426.00) page 18
675.0430.00 Cable 32 pairs, DIN 41612 to open end (675.0430.00) page 22
675.0432.00 Combo Solution 32 pairs Y-cable, DIN 41612 to open end (675.0432.00) page 25
675.0434.00 Combo Solution 48 pairs Y-cable, 2 x DIN 41612 to open end (675.0434.00) page 28
675.0435.00 Combo Solution 48 pairs Y-cable, 3 * DIN 41612 plug to LEA 48 port splitter page 35
(675.0466.00)
675.0440.00 Cable for shelf splitter, CHAMP to open end (675.0440.00) page 45
675.0450.00 Cable 32 pairs to shelf splitter, DIN 41612 to CHAMP (675.0450.00) page 51
675.0457.00 E&M voice interface cable, 8 channels, 8x8 wires, open end (675.0457.00) page 95
675.0460.00 COGE1 T3 SYNC cable, D-SUB 9 pins to open end (675.0460.00) page 55
675.0461.00 Ethernet GbE cat5e, RJ45 plug to RJ45 plug (675.0461.00) page 56
675.0466.00 Combo Solution 48 pairs Y-cable, 3 * DIN 41612 plug to LEA 48 port splitter page 35
(675.0466.00)
675.0467.00 Ethernet GbE cat5e, RJ45 plug to RJ45 plug thin (675.0467.00) page 57
675.0470.00 Adapter for 2 x SUIx to shelf splitter, 2 x DIN 41612 to 64-pin CHAMP (675.0470.00) page 61
675.0471.03 MileGate 25xx Power Supply cable, crimp type socket to open end (675.0471.03) page 65
675.0472.01 Adapter 2x16 pairs DIN 41612 to 1x32 pairs DIN male (675.0472.01) page 66
675.0487.00 Cable 64 pairs, DIN 41612 double plug to open end (675.0487.00) page 41
675.0488.00 Combo Solution 64 pairs Y-cable, 2 * DIN 41612 double plug to open end (675.0488.00) page 31
A31A1166 Cable G.703 / 75 ohms, DIN 41612 to BNC (A31A1166) page 75
A31A1167 Cable G.703 / 75 ohms, DIN 41612 to open end (A31A1167) page 74
A21A6088 8 x 2 Mbit/s cable 120 ohms, DIN 41612 to open end (A21A6088) page 67
A21A8448 8 pair xDSL cable, DIN 41612 to open end (A21A8448) page 70
A21A9151 8 x 2 Mbit/s cable 75 ohms, DIN 41612 to open end (A21A9151) page 72
A30A1249 Cable RS485 to open end (A30A1263) page 84
A30A1259 V.24/V.28 to D-Sub25 connector (A30A1259) page 90
A30A1260 V.35 to Winchester connector (A30A1260) page 85
A30A1261 X.24/V.11 to D-Sub15 connector (A30A1261) page 93
A30A1262 X.24/V.11 to open end (A30A1262) page 91
A30A1263 Cable RS485 to open end (A30A1263) page 85
A30A2446 DATAx universal (all pins connected) to open end (A30A2446) page 95
generic Generic USB cable, USB mini-B to USB A page 76
- Optical Cable SM 9/125 duplex, LC to E2000 8° straight page 77
- Optical Cable MM 50/125 duplex, LC to SC straight page 78
- Optical Cable SM 9/125 duplex, LC to SC straight page 79
- Optical Cable SU to ODF SM 9/125 simplex, LC APC with 45° boot to SC APC page 80
- Optical Cable optical amplifier to SU SM 9/125 simplex, LC APC with 45° boot to LC APC page 81
with 45° boot
4 Reference of cables
All cables are sorted by the Cable PEC which is shown in brackets in the
cable name.
4.1 MileGate 25xx Power cable 0.4m, crimp type socket to cage
clamp (675.0426.00)
Figure 1: MileGate 25xx Power cable 0.4m, crimp type socket to cage
clamp (675.0426.00)
blue red
blue red
This cable ist suitable for any service unit with up to 32 ports used in Mile-
Gate 2500 or MileGate 2510 subrack.
Pin assignment is defined by the service unit.
Maximum length depends on the interface offered by service unit.
Table 11: Cable termination
End Type
Unit DIN plug 41612 female
Far open end.
blue
group 1A
blue
group 1B
orange
group 2A
orange
group 2B
This cable joins the signals of two units of the type SUPC3 with 32 ports and
an ADSL unit to be transported to an MDF.
Table 15: Cable termination
End Type
Unit 2 x DIN plug 41612 female
Far open end.
blue
group 1A
blue
group 1B
orange
group 2A
orange
group 2B
This cable joins the signals of two units of the type SUPC4 with 48 ports and
an ADSL unit to be transported to an MDF.
Pin assignment of the unit end plugs is determined by the service unit.
Table 19: Cable Termination
End Type
Unit 2 * DIN 41612 female
Far open end
blue
group 1A
green
group 3A
blue
group 1B
orange
group 2A
green
group 3B
orange
group 2B
This cable joins the signals of two units of the type SUPC3 with 64 ports and
an ADSL unit to be transported to an MDF.
Table 23: Cable termination
End Type
Unit 2 x DIN double plug 41612 female
Far open end.
Figure 11: Combo Solution 64 pairs Y-cable, 2 * DIN 41612 double plug
to open end (675.0488.00)
Figure 12: Wiring and pins for 64 pair DIN 41642 double plug
This cable joins the signals of two units of the type SUPC3 with 64 ports and
an ADSL unit to be transported to an MDF.
Table 27: Cable termination
End Type
Unit 3 x DIN plug 41612 female
Far 1 x LEA port plug
Figure 13: Combo Solution 48 pairs Y-cable, 3 * DIN 41612 plug to LEA
48 port splitter (675.0466.00)
This cable is suitable for any 48-port and/or 32-port service unit used in a
MileGate.
Please refer to your unit’s pin assignment.
Table 30: Cable Termination
End Type
Unit DIN 41612 female
Far open end
blue
group 1A
green
group 3A
blue
group 1B
orange
group 2A
green
group 3B
orange
group 2B
This cable ist suitable for any service unit with 64 ports used in MileGate
2500 or MileGate 2510 subrack.
Pin assignment is defined by the service unit.
Maximum length depends on the interface offered by service unit.
Table 34: Cable termination
End Type
Unit DIN 41612 double plug female
Far open end.
Figure 18: Cable 64 pairs, DIN 41612 double plug to open end
(675.0487.00)
Figure 20: Cable for shelf splitter, CHAMP to open end (675.0440.00)
blue
group 1a
blue
group 1b
orange
group 2a
orange
group 2b
This cable connects a 48-port splitter line output to an MDF. One end fea-
tures a specific connector for the splitter. This cable is not to be used for
units plugged into a MileGate subrack.
Table 42: Cable Termination
End Type
Unit open end
Far (splitter) DIN 41612 female
blue
group 1A
green
group 3A
blue
group 1B
orange
group 2A
green
group 3B
orange
group 2B
This cable directly connects any 32-port service unit with a shelf splitter. So
both ends feature specific connectors. This cable is to be used for units
plugged into a MileGate 2500 or MileGate 2510.
Table 46: Cable Termination
End Type
Unit DIN 41612 female
Far (splitter) 64-pin CHAMP
blue
group 1A
blue
group 1B
orange
group 2A
orange
group 2B
blue
group 1A
blue
group 1B
orange
group 2A
orange
group 2B
Cable for Gigabit Ethernet connections for units with high port density or
thight space in the subrack.
Table 57: Cable Termination
End Type
Unit RJ45
Far RJ45
Figure 31: Ethernet GbE cat5e, RJ45 plug to RJ45 plug thin
(675.0467.00)
This cable has 48 wire pairs. It transports the signals from a 48 port unit
directly (without MDF) to a shelf splitter.
Table 60: Cable Termination
End Type
Unit DIN 41612 female
Far DIN 41612 female
blue
group 1A
green
group 3A
blue
group 1B
orange
group 2A
green
group 3B
orange
group 2B
This cable has 32 wire pairs. It transports the signals of two units of the type
SUIx with 16 ports directly (without MDF) to a shelf splitter.
Table 64: Cable Termination
End Type
Unit 2 * DIN 41612 female
Far 64-pin CHAMP
Figure 35: Adapter for 2 x SUIx to shelf splitter, 2 x DIN 41612 to 64-pin
CHAMP (675.0470.00)
cable 1
ports 1 .. 16
cable 2
ports 17.. 32
4.18 MileGate 25xx Power Supply cable, crimp type socket to open
end (675.0471.03)
Figure 38: MileGate 25xx Power Supply cable, crimp type socket to
open end (675.0471.03)
blue red
blue red
4.19 Adapter 2x16 pairs DIN 41612 to 1x32 pairs DIN male
(675.0472.01)
Figure 40: Adapter 2x16 pairs DIN 41612 to 1x32 pairs DIN male
(675.0472.01)
Figure 41: Pins for Adapter 2x16 pairs DIN 41612 to 1x32 pairs DIN
male (675.0472.01)
Figure 42: 8 x 2 Mbit/s cable 120 ohms, DIN 41612 to open end
(A21A6088)
Figure 43: Pins for 8 x 2 Mbit/s cable 120 ohms, DIN 41612 to open end
(A21A6088)
Table 78: 8 x 2 Mbit/s cable 120 ohms, DIN 41612 to open end
(A21A6088) (section 1 of 2)
Row Direction Colour pin C Line
1 Input White a
2 Input Blue b
3 Output Black a
4 Output Blue b
5 Input White a
6 Input Orange b
7 Output Black a
8 Output Orange b
9 Input White a
10 Input Green b
11 Output Black a
12 Output Green b
13 Input White a
14 Input Brown b
15 Output Black a
16 Output Brown b
17 Input Red a
18 Input Blue b
19 Output Yellow a
Table 78: 8 x 2 Mbit/s cable 120 ohms, DIN 41612 to open end
(A21A6088) (section 2 of 2)
Row Direction Colour pin C Line
20 Output Blue b
21 Input Red a
22 Input Orange b
23 Output Yellow a
24 Output Orange b
25 Input Red a
26 Input Green b
27 Output Yellow a
28 Output Green b
29 Input Red a
30 Input Brown b
31 Output Yellow a
32 Output Brown b
Figure 44: 8 pair xDSL cable, DIN 41612 to open end (A21A8448)
Figure 45: Pins for 8 pair xDSL cable, DIN 41612 to open end
(A21A8448)
Table 82: Pins for 8 pair xDSL cable, DIN 41612 to open end
(A21A8448)
Row Colour pin C Line pin Colour pin A Line pin Line
2 Blue b White a 1
6 Orange b White a 2
10 Green b White a 3
14 Brown b White a 4
18 Blue b Red a 5
22 Orange b Red a 6
26 Green b Red a 7
30 Brown b Red a 8
Figure 47: Pins for 8 x 2 Mbit/s cable 75 ohms, DIN 41612 to open end
(A21A9151)
Table 86: Pins for 8 x 2 Mbit/s cable 75 ohms, DIN 41612 to open end
(A21A9151)
Row Colour Pin C Line pin Colour pin a Line pin Line
1 White S Blue a Rx1
3 Black S Blue a Tx1
5 White S Orange a Rx2
7 Black S Orange a Tx2
9 White S Green a Rx3
11 Black S Green a Tx3
13 White S Brown a Rx4
15 Black S Brown a Tx4
17 Red S Blue a Rx5
19 Yellow S Blue a Tx5
21 Red S Orange a Rx6
23 Yellow S Orange a Tx6
25 Red S Green a Rx7
27 Yellow S Green a Tx7
29 Red S Brown a Rx8
31 Yellow S Brown a Tx8
This cable provides input and outputs to/ from the SYN4M unit with SFP
modules for STM-1 G.703 / 75 Ohm circuits. The other end of this cable is
not terminated. Two cables are required to fully connect the SYN4M electri-
cal interface (one for Rx, one for Tx).
Longer cables than the maximum length may lead to malfunctions of interop-
erability with third party equipment.
Table 87: Cable Termination
End Type
Unit DIN 1.0/2.3 LEMO connector push-pull
self latching/coupling
Far open end
Figure 48: Cable G.703 / 75 ohms, DIN 41612 to open end (A31A1167)
This cable provides input and outputs to/ from the SYN4M unit with SFP
modules for STM-1 G.703 / 75 Ohm circuits. The other end of this cable is
terminated with a BNC connector Two cables are required to fully connect
the SYN4M electrical interface (one for Rx, one for Tx).
Longer cables than the maximum length may lead to malfunctions of interop-
erability with third party equipment.
Table 90: Cable Termination
End Type
Unit DIN 1.0/2.3 LEMO connector push-pull
self latching/coupling
Far 1 BNC connector (male)
Connects the CATV connector of SUEN3 with the optical CATV amplifier.
The plug is bent by 45° to save installation space.
Connectors usually are of the colour green.
Figure 58: Example for Optical Cable SFP with LC-PC duplex to LC-PC
duplex
4.39 E&M voice interface cable, 8 channels, 8x8 wires, open end
(675.0457.00)
Figure 74: E&M voice interface cable, 8 channels, 8x8 wires, open end
(675.0457.00)