BOQ HVAC WORKS

Eng .Hesham Saber


Electromechanical Consultunt
HVAC Hospital BUILDING PROJECT PRICE (EGP)
ITEM UNIT QTY. UNIT
REF.
ITEM DESCRIPTION TOTAL
RATE
DUCT INSULATION

Supply,Install thermal insulation for indoor supply, return


and treated fresh air ducts in concealed areas complete
a
with adhesive, tapes, wire banding and any other
accessories needed for proper installation and operation.

a-1 Duct surface area sq.m 15750

Supply,Install thermal insulation for indoor & outdoor


Supply, return and treated fresh air ducts exposed to view,
in unfinished areas, mechanical and electrical equipment
b
rooms, and attics containing air handling units complete
with adhesive, tapes, wire banding and any other
accessories needed for proper installation and operation.

b-1 Duct surface area sq.m 4000


PIPE INSULATION

Supply,Install thermal insulation for indoor & outdoor


supply and return heating water pipes exposed to view
c complete with adhesive, tapes, wire banding and any
other accessories needed for proper installation and
operation.

c-1 50 mm dia. m 20

c-2 65 mm dia. m 165

c-3 75 mm dia. m 160

c-4 110 mm dia. m 150


c-5 150 mm dia. m 300

c-6 200 mm dia. m 50


VALVES

Note: All valves related to equipment hook up are to


be included in the price of each relevant equipment.

Supply,Install, connect, test and commission gate valves


d including all required fittings and accessories for proper
operation and installation.

d-1 200 mm dia. nr 12

d-2 250 mm dia. nr 12

Supply,Install, connect, test and commission balancing


e valves including all required fittings and accessories for
proper operation and installation.

e-1 200 mm dia. nr 6


e-2 250 mm dia. nr 6

PAGE TOTAL (CARRIED TO COLLECTION SUMMARY SHEET)

1/7
BOQ HVAC WORKS
Eng .Hesham Saber
Electromechanical Consultunt
HVAC Hospital BUILDING PROJECT PRICE (EGP)
ITEM UNIT QTY. UNIT
REF.
ITEM DESCRIPTION TOTAL
RATE
HYDRONIC PIPING

supply,Install, connect, test and commission hydronic


piping for chilled pipes including all accessories, fittings,
gaskets, sealers, coupling, expansion joints, supports,
f
hangers, rods, anchors, saddles, cladding for the external
pipes 0.6 mm thick aluminium and proper connections
with equipment.

f-1 50 mm dia. m 20

f-2 65 mm dia. m 165

f-3 75 mm dia. m 170

f-4 110 mm dia. m 155

f-5 150 mm dia. m 300

f-6 200 mm dia. m 50

Install, connect, test and commission network drainage


pipes (GI pipe) for A/C systems testing including pipe
fittings, supports, hangers, sleeves, inserts and all
g required coupling and adapters as specified and shown on
drawings.
L.S 1
HYDRONIC PUMPS
Supply,Install, connect, test and commission hydronic
pumps including all required hook up valves and
accessories as per drawings, supports, vibration isolators,
h and fittings required for proper operation and installation
in schedule equipment.

Type CH.W.P-01
h-1 CH.W.Rate of flow :1080 GPM at H= 120 FT nr 3
Type CT.W.P-01 nr 3
h-2 Condenser.W.Rate of flow :1981 GPM at H=45 FT
WATER TREATMENT
Supply,Install complete water treatment system for
i HVAC network (chilled and Heating water). LS 1
Supply,Install complete water treatment system for
cooling tower water network.
j LS 1
EXPANSION TANK
Supply,Install expansion tanks complete with fittings,
accessories including jointing to pipes and fittings
required for proper operation and installation.
k nr 2

PAGE TOTAL (CARRIED TO COLLECTION SUMMARY SHEET)

2/7
BOQ HVAC WORKS
Eng .Hesham Saber
Electromechanical Consultunt
HVAC Hospital BUILDING PROJECT PRICE (EGP)
ITEM UNIT QTY. UNIT
REF.
ITEM DESCRIPTION TOTAL
RATE
AIR SEPARATOR
Supply,Install air separator including gate valves for inlet,
outlet and by-pass, automatic air vent with cock, drain
valve, and othe accessories required for proper operation
and installation.
l nr 2
COOLING TOWERS
Supply,Install, connect, test and commission cooling
towers including all required hook up valves, contols,
neoprene connectors, thermometers, flow meters, pressure
gauges, flow switches, drainage valve, vent cock, over
flow, make up and bleed valves, supports, vibration
m isolators, and fittings required for proper operation and
installation
Ambient Temp:46 ◦C
Entering Condenser.W.TEMP:32 ◦C
Leaving Condenser.W.TEMP:37.2 ◦C
Condenser.W.Rate of flow :1981.3 GPM

m-1 Type CT nr 2
Absorption CHILLERS

Supply,Installation and commmissioning of two


stages,parallel flow direct fired absorption chillers
including hook up valves, supports, flexible connection
and complete with controls and required accessories for
proper installation and operation. Unit shall be factory
assembled and shipped as one piece from factory after
completing all factory tests. The unit shall be heavy duty
type and shall be designed to work for minimum 8000 hr
n running throughout the year. Unit shall be complete with
chimmney, hot and cold side insulation, all piping
connections, balancing valves, indicators, flow switches,
control panels, interface to the BMS system, initial
refrigerant charge, solution and refrigerant pumps, burner
(dual type-natural gas and oil-2),and in general all
woak,parts, devices, accessories, fittings and attachments
required for safe and proper operation of the unit as
herein specified and according to specification.Each unit
shall be according but not limited to the following
specification: Refrigeration capacity : 450 TR, C.O.P not
less than 1.35 at full load.
Ambient Temp:46 ◦C
Entering CH.W.TEMP:12.0 ◦C
Leaving CH.W.TEMP:6.5 ◦C
CH.W.Rate of flow :1080 GPM
Entering Condenser.W.TEMP:32 ◦C
Leaving Condenser.W.TEMP:37.2 ◦C
Condenser.W.Rate of flow :1981 GPM
Fouling Factor For Chilled & Cooling Water:0.000086
m²k/w
Fuel Type : Natural Gas/Oil-2
Compelete with ful buffer tank system suitabla for
working 24 Hours at emergency case.
Approved Maanufacture :
HTACHI,TRANE,KAWASAKI (ORIGIN : USA OR
JAPAN)

n-1 Type CH nr 2

PAGE TOTAL (CARRIED TO COLLECTION SUMMARY SHEET)

3/7
BOQ HVAC WORKS
Eng .Hesham Saber
Electromechanical Consultunt
HVAC Hospital BUILDING PROJECT PRICE (EGP)
ITEM UNIT QTY. UNIT
REF.
ITEM DESCRIPTION TOTAL
RATE

METAL DUCTS
DUCT ACCESSORIES

Supply,Install, connect, test and commission metal duct


(TDS) works including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant, internal
o
turning vanes, felxible connectors, galvanized steel wire
mesh screen at any duct openings and all required
accessories for proper installation and operation.

o-1 Galvanized ductwork kg 162,000

supply, Install, connect, test and commission metal duct


linning at air handling units supply ducts (within three
p
meters length) including all required accessories for
proper installation and operation. sq.m 3,600

Supply,Install, connect, test and commission automatic


volume dampers at each supply grille , diffuser and at
q
each main supply duct including all required accessories
for proper installation and operation.
LS 1
Supply and installation Aluminum cladding 0.6 mm
thickness to exposed supply ,return ducts & chilled water
r
pipes return and supply including all required accessories
for proper installation and operation. LS 1
Supply,Install, connect, test and commission fire dampers
s including all required accessories for proper installation
and operation. LS 1
Supply, Install, connect, test and commission smoke and
fire including all required accessories for proper
t
installation and operation for each baranch in FAHU &
main line supply & rutern for AHU & EX.F.
LS 1
CENTRIFUGAL FANS
POWER VENTILATORS
Supply,Install, connect, test and commission fans
including steel bases, frames, rubber pads, sealers for
leakage, flexible connections with ducts, guard screens,
u vibration isolators, and all required accessories for proper
installation and operation as per schedule of equipment
and specifications and maintenance for old.

u-1 Wall Mounted


u-1-1 Type Ex.F 2200 CFM nr 2
u-1-2 Type Ex.F 3800 CFM nr 1
u-1-3 Type Ex.F 40 CFM nr 131
u-1-4 Type Ex.F 70 CFM nr 45
u-1-5 Type Ex.F 150 CFM nr 116
u-1-6 Type Ex.F 6750 CFM nr 1
u-1-7 Type Ex.F 5000 CFM nr 1
u-1-8 Type Ex.F 170 CFM nr 10
u-1-9 Type Ex.F 840 CFM nr 4

PAGE TOTAL (CARRIED TO COLLECTION SUMMARY SHEET)

4/7
BOQ HVAC WORKS
Eng .Hesham Saber
Electromechanical Consultunt
HVAC Hospital BUILDING PROJECT PRICE (EGP)
ITEM UNIT QTY. UNIT
REF.
ITEM DESCRIPTION TOTAL
RATE
u-2 AXIAL INLINE Mounted
Fresh Air Fans with pre filter
u-2-1 Type Ex.F 8184 CFM & ESP-0.5 in.wg nr 1

u-2-2 Type Ex.F 4521 CFM & ESP-1 in.wg nr 1

u-2-3 Type Ex.F 9050 CFM & ESP-1 in.wg nr 1

u-2-4 Type F.A.F 6550 CFM & ESP-1 in.wg nr 1

u-2-5 Type F.A.F 5000 CFM & ESP-1 in.wg nr 1

MOTOR CONTROL CENTERS (MCC)

(IP 55 exposed cabinets ),all safety and operating


controls, including switchboards,ammeters,
voltmeter,indication lamps,isolating switches, push
buttons, main circuit breakers, contactors, overloads,
v
fuses, startes, relays, manual & automatic switches,
alarms, interlocks, earthing...etc as herein specified.
and VARIABLE SPEED DRIVE FOR FAHU
L.S 1
SPILT UINT
SUPPLY ,Install, connect, test and commission SPILT
UINT including Ref. pipe and Ref.(R-22) steel bases,
frames, rubber pads,flexible connections with ducts,
w guard screens, and all required accessories for proper
installation and operation as per Drawing and
specifications.

w-1 Type SP-01 2 T.R ( 24000 BTU /HR ) nr 1

w-2 Type SP-01 2.5 T.R (30000 BTU/HR) nr 1


CENTRAL-STATION AIR-HANDLING UNITS

Supply,Install, connect, test and commission central


station air handling units, including hook up valves,
supports, vibration isolators, flexible connection and
x complete with controls and required accessories for
proper installation and operation and maintenance for old.

x-1 Type FAUH-01 50.2 T.R 9050 CFM Ex.S 2 inw nr 1


x-2 Type FAUH-02 25 T.R 4521 CFM Ex.S 2 inw nr 1
x-3 Type FAUH-03 40 T.R 7268 CFM Ex.S 2 inw nr 1
x-4 Type FAUH-04 36 T.R 6503 CFM Ex.S 2 inw nr 1
x-5 Type FAUH-05 30.6 T.R 5520 CFM Ex.S 2 inw nr 1
x-6 Type AUH-01 40.4 T.R 14149 CFM Ex.S 2 inw nr 1
x-7 Type AUH-02 51.5 T.R 18030 CFM Ex.S 2 inw nr 1
x-8 Type AUH-03 22.8 T.R 7100 CFM Ex.S 2 inw nr 1

x-9 Type AUH-04 22.3 T.R 7792 CFM Ex.S 2 inw nr 1


x-10 Type AUH-05 25.4 T.R 8897 CFM Ex.S 2 inw nr 1

PAGE TOTAL (CARRIED TO COLLECTION SUMMARY SHEET)

5/7
BOQ HVAC WORKS
Eng .Hesham Saber
Electromechanical Consultunt
HVAC Hospital BUILDING PROJECT PRICE (EGP)
ITEM UNIT QTY. UNIT
REF.
ITEM DESCRIPTION TOTAL
RATE

x-11 Type AUH-06 30 T.R 10553 CFM Ex.S 2 inw nr 1

x-12 Type AUH-07 30.5 T.R 10684 CFM Ex.S 2 inw nr 1


x-13 Type AUH-08 31.7 T.R 11108CFM Ex.S 2 inw nr 1
x-14 Type AUH-09 26.1 T.R 9142 CFM Ex.S 2 inw nr 1
x-15 Type AUH-10 26.5 T.R 7508 CFM Ex.S 2 inw nr 1
x-16 Type AUH-12 32.5 T.R 11389 CFM Ex.S 2 inw nr 1
x-17 Type AUH-13 29.5 T.R 10319 CFM Ex.S 2 inw nr 1
x-18 Type AUH-14 22.6 T.R 7917 CFM Ex.S 2 inw nr 1
x-19 Type AUH-16 10.8 T.R 3813 CFM Ex.S 2 inw nr 1
x-20 Type AUH-17 26.1 T.R 9142 CFM Ex.S 2 inw nr 1
x-21 Type AUH-18 31.7 T.R 11108 CFM Ex.S 2 inw nr 1
x-22 Type AUH-19 26.5 T.R 7508 CFM Ex.S 2 inw nr 1
x-23 Type AUH-20 32.5 T.R 11389 CFM Ex.S 2 inw nr 1
x-24 Type AUH-21 29.5 T.R 10319 CFM Ex.S 2 inw nr 1
x-25 Type AUH-22 12 T.R 4203 CFM Ex.S 2 inw nr 1
x-26 Type AUH-23 10.8 T.R 3813 CFM Ex.S 2 inw nr 1

x-27 Type AUH-24 12 T.R 4203 CFM Ex.S 2 inw nr 1


Fan Belts: Furnish one set for each central-station air-
x-28 handling unit fan nr 6
Gaskets: Furnish one sectional joint of each central-
x-29 station air-handling unit. L.S 1

DIFFUSERS, REGISTERS, AND GRILLES


Supply, install, connect, test, balance and commission of
air outlets and inlets complete with clamps, plenums,
y hangers, supports, painting as per Architect approval and
any other required accessories for proper installation and
operation.
y-1 Type SAD 24" x 24" nr 532
y-2 Type RAD 24" x 24" nr 530

y-3 Fresh air louver with Sand Trap nr 2


y-4 Exhuast air louver nr 4

y-5 Hoode Exhuast nr 1

Building Management System (BMS)

Supply,Install,Building Management System (BMS) is a


computer-based control system installed in buildings that
controls and monitors the building's mechanical and
electrical equipment such as ventilation,lighting, power
z systems, fire systems, and security systems. LS 1

PAGE TOTAL (CARRIED TO COLLECTION SUMMARY SHEET)

6/7
BOQ HVAC WORKS
Eng .Hesham Saber
Electromechanical Consultunt
HVAC Hospital BUILDING PROJECT PRICE (EGP)
ITEM UNIT QTY. UNIT
REF.
ITEM DESCRIPTION TOTAL
RATE

A Total of Page 1

B Total of Page 2

C Total of Page 3

D Total of Page 4

E Total of Page 5

F Total of Page 6

TOTAL OF HVAC WORKS

7/7