ASC CD Tab19 Roto-Glide MSDS 2946 0267 01 - tcm48-764788
ASC CD Tab19 Roto-Glide MSDS 2946 0267 01 - tcm48-764788
ASC CD Tab19 Roto-Glide MSDS 2946 0267 01 - tcm48-764788
INTENDED USES:
Lubricating grease.
2. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous ingredients present at or above regulatory disclosure levels:
None
3. HAZARD IDENTIFICATION
This product is not considered hazardous according to EU regulatory guidelines.
It is of low oral and dermal toxicity and under normal conditions of use should present no
significant health hazards. However, in common with most mineral oils, prolonged and
repeated skin contact may cause dermatitis.
Note: This product should not be used for any other purpose without expert advice.
SKIN CONTACT:
If irritation should occur, wash with soap and water.
Consult a physician immediately if the material is injected under the skin from the misuse of
high pressure greasing equipment.
EYE CONTACT:
Rinse immediately with plenty of water until irritation subsides. If irritation persists, obtain
medical advice.
INGESTION:
If swallowed, keep at rest and call a physician. Do not induce vomiting unless directed to do
so by a medical professional.
5. FIRE-FIGHTING MEASURES
EXTINGUISHING MEDIA: Foam, dry chemical powder, carbon dioxide.
Respiratory and eye protection required for fire fighting personnel exposed to fumes or
smoke.
LAND SPILL:
Recover residual material; add absorbent to the spill area and remove mechanically into
containers. If necessary, dispose of adsorbed residues as directed in Section 13.
Advise the relevant authorities if material has entered a water course or sewer, or has
contaminated soil / vegetation. Take measures to minimise the effects on ground water.
WATER SPILL:
Data not available.
Store the product in cool, well ventilated surroundings, well away from sources of ignition.
Provide suitable mechanical equipment for the safe handling of drums and heavy packages.
Electrical equipment and fittings must comply with local regulations regarding fire prevention
with this class of product.
SPECIAL PRECAUTIONS:
Keep containers closed when not in use.
Where only incidental contact is likely, wear safety glasses with side shields. No other special
precautions are necessary provided skin/eye contact is avoided.
When concentrations in air may exceed the occupational exposure limit, and where
engineering, work practices, or other means of exposure reduction are not adequate,
approved respirators may be required.
OTHER INFORMATION:
DMSO EXTRACT (METHOD IP 346) % BY WT: Less than 3.0
CONDITIONS TO AVOID:
Keep away from heat sources, open flames and other sources of ignition.
INCOMPATIBLE MATERIALS:
Avoid contact with strong oxidants such as liquid chlorine and concentrated oxygen.
Elevated temperatures or mechanical action may form vapours, mists, or fumes which may
be irritating to the eyes, nose, throat, and lungs.
SKIN CONTACT:
Low order of acute toxicity.
High pressure grease gun injection injury, where grease is injected through the skin on any
part of the body, can cause serious delayed soft tissue damage and should be treated
immediately as a surgical emergency.
EYE CONTACT:
Slightly irritating, but does not injure eye tissue.
INGESTION:
Low order of acute/systemic toxicity.
CHRONIC:
Base oil components of this product have shown no carcinogenic activity in experimental
animals (long-term repeated skin painting tests).
TOXICITY DATA:
ACUTE:
No test data are available for the complete formulated product. The potential health hazards
described were therefore derived from what is generally known of the toxicity of the base oils
and the additives, taking into account the concentrations at which they are present. The
general effects of mineral oils of this type are well known and are described in numerous
publications including CONCAWE Report 5/87 "Health Aspects of Lubricants".
CHRONIC:
The base oils for this product have been subjected to a lifetime skin painting bioassay using a
standard Exxon test protocol; there was no evidence of carcinogenicity.
ECOTOXICITY:
Available ecotoxicity data (LL50>1000 mg/L) indicates that adverse effects to aquatic
organisms are not expected from this product.
MOBILITY:
Not established.
BIOACCUMULATIVE POTENTIAL:
Not established.
(Note: these codes are assigned based upon the most common uses for this product and
may not reflect contaminents resulting from actual use. Purchasers may need to reassign
waste disposal codes based on actual use.)
Not regulated for transport by: land under ADR/RID regulations, inland waterways under
ADNR regulations, sea under IMO regulations and air under IATA regulations.
The recommendations presented in this Material Safety Data Sheet were compiled from
actual test data (when available), comparison with similar products, component information
from suppliers and from recognised codes of good practice.
The information and recommendations contained herein are, to the best of ExxonMobil's
knowledge and belief, accurate and reliable as of the date issued, but are offered without
guarantee or warranty. They relate to the specific material designated and may not be valid
for such material used in combination with any other materials or in any process. Conditions
of use of the material are under the control of the user; therefore, it is the user's responsibility
to satisfy himself as to the suitability and completeness of such information for his own
particular use.