0 - PRACTICE QUESTIONS
←1) Do the mechanical tests support qualification of this PQR?
← Yes
← No, one tensile test failed.
← Face Bends and root Bends should have been performed instead of side bends.
← The 3/32” defect in the heat effected zone on the side bend tests is over the acceptable limit.
Note:
.758 x ,752 = .570 sq. in.
37850/57 x 100 = 66403.5
70000 x .95 = 66500
66403.5 , 66500 so the tensile failed & the report is incorrect
← No, the sketch of the joint must also show weld layers & specify uphill or downhill.
← Yes
← No, root spacing is not addressed.
← No, spacing between backing strip & base metal must also be addressed.
Note:
If a sketch of the joint is not supplied and a note such as; “See drawings.” is entered in place of a
sketch it is not acceptable unless the sketch is supplied with the WPS. The WPS is used to provide
direction to the welder. It is not acceptable to allow the welder to choose the joint design or type he
desires.
←3) The full range qualified for the base metal thickness that may be welded with this WPS is:
← 1/16” to 1 1/2”
← 3/16” to 1 1/8”
← As shown on the WPS
← None of the above
←4) The actual maximum throat dimension allowed for the weld metal thickness “t” for fillet welds:
← 5) If a joint was made using this WPS and the welder put in a single pass with a deposited weld
metal thickness, “t”, of 9/16” :
← 6) The minimum preheat temperature that this WPS could specify without requalification is:
← 200O F
← 300O F
← 50O F
← 100O F
←7) To increase the full range qualified for “T” on the WPS to 3/16” to 2”:
← The original coupon used for the PQR would have to have been 1” thick.
← The WPS only needs editorial revision to allow the welding the thicker material.
← The preheat temperature needs to be increased to 300 O F.
← The method of back gouging must be restricted to grinding only.
← 8) The full range of A Number qualification which may be shown on the WPS is:
← Correct as shown
← 1/16” - 1”
← 3/16” - 1/2”
← 3/16” - 1/4”
← Correct as shown
← Should be 75% AR 25% CO2
← Should be shown as 20-30 CFH
← Both B & C above
← 3) The proper preheat temperature range that should be shown on the WPS is:
← Correct as shown
← 100°F minimum
← 250° maximum
← 150° minimum
a. unacceptable because it was run in the 1G position and the WPS states all
positions are acceptable.
b. unacceptable because it is not certified.
c. unacceptable because it was run with backing gas and the WPS does not require
backing gas.
d. none of the above
13) The best explanation for the problems observed on the PQR is:
2) B
3) D
4) A
5) D
6) C
7) C
8) D
9) B
10) C
11) B
12) A
13) D