Specifikace:

  • Model: 2730C/3050 Construction Heaters
  • Address: 342 N. Co. Rd. 400 East Valparaiso, IN 46383
  • Designed for: Temporary heating of buildings under
    construction, alteration, or repair
  • Compliance Standards: ANSI Z83.7a-1993, NFPA-58 1989, ANSI
    A119.2(NFPA 501C)-1987

Návod k použití produktu:

Důležité bezpečnostní informace:

For your safety, do not use this heater in spaces where
flammable liquids are stored. The primary purpose of the
construction heater is to provide temporary heating for
construction sites and emergency situations. Ensure proper
ventilation and comply with all safety regulations.

Zakázané použití:

The heater is not designed for home use or in recreational
vehicles. Do not store LP-gas containers inside recreational
vehicles or use unvented heaters in such vehicles.

Soulad se standardy:

Ensure that the use of the heater complies with NFPA standards
and local codes. Contact your local fire safety authority for any
questions regarding regulations.

Obecné varování před nebezpečím:

Failure to follow precautions may result in serious injury or
property damage. Only individuals who can understand and follow
instructions should operate or service the heater.

Upozornění:

Avoid placing combustible materials near the heater. Do not use
the heater in spaces with volatile or airborne combustibles. Keep
away from gasoline, solvents, paint thinner, and other
chemikálie.

FAQ:

Q: Can the construction heater be used in a residential
domov?

A: No, the heater is not designed for home use and should only
be used in temporary construction settings or for emergency heating
účely.

Q: What should I do if I have questions about local
předpisy?

A: Contact your local fire safety authority for guidance on
compliance with local regulations and standards.

“`

342 N. Co. Rd. 400 East Valparaiso, IN 46383
219-464-8818 · Fax 219-462-7985 www.heatwagon.com
Návod k instalaci a údržbě
Uschovejte si prosím tento návod pro budoucí použití.
2730C/3050
Stavební ohřívače

Revize 11-24

C

US

This QR Code can be found under the control box lid

For your safety: Do not use this heater in a space where gasoline or other liquids
having flammable vapors are stored.

DŮLEŽITÁ INFORMACE! PŘEČTĚTE SI NEJPRVE
The heater is designed for use as a construction heater under ANSI Z83.7a-1993. Heater is not intended for use in pest remediation. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration, or repair and to provide emergency heat. Properly used, the heater provides safe, economical heating. Products of combustion are vented into the area being heated.
Ohřívač NENÍ navržen jako pokojový ohřívač s neventilovaným plynem podle ANSI-Z21.11.2 a NEMĚL by se používat v domácnosti.
Norma ANSI A119.2(NFPA 501C)-1987 pro rekreační vozidla zakazuje instalaci nebo skladování nádob na zkapalněný plyn, a to i dočasně uvnitř jakéhokoli rekreačního vozidla. Norma také zakazuje použití neventilovaných ohřívačů v takových vozidlech.
NORMA NFPA-58 1989 PRO SKLADOVÁNÍ A MANIPULACE SE ZKAPALNĚNÝMI ROPNÝMI PLYNY
Použití ohřívače musí být v souladu s touto normou a v souladu se všemi platnými státními a místními předpisy. Skladování a manipulace s propanem a propanovými lahvemi musí být v souladu s NFPA 58 a všemi místními předpisy.
Nemůžeme předvídat každé použití našich ohřívačů. POKUD MÁTE DOTAZY TÝKAJÍCÍ SE MÍSTNÍCH PŘEDPISŮ, OVĚŘTE SE U SVÉHO MÍSTNÍHO ORGÁNU PRO POŽÁRNÍ BEZPEČNOST.
Jiné normy upravují použití palivových plynů a produktů produkujících teplo ve zvláštních aplikacích. O tom vám může poradit místní úřad.
PRO VAŠI BEZPEČNOST
NEPOUŽÍVEJTE TENTO OHŘÍVAČ V PROSTORU, KDE SE SKLADUJE NEBO POUŽÍVÁ BENZÍN NEBO JINÉ KAPALINY S HOŘLAVÝMI PÁRY.
NEVER USE THE HEATER IN SPACES WHICH ARE NOT SUFFICIENTLY SIZED OR VENTILATED FOR THE HEATER BEING UTILIZED.
VŠEOBECNÉ VAROVÁNÍ PRO STAVEBNÍ OHŘÍVAČ:
Nedodržení bezpečnostních opatření a pokynů dodaných s tímto ohřívačem může mít za následek smrt, vážné zranění a ztrátu nebo poškození majetku v důsledku nebezpečí požáru, výbuchu, popálení, udušení, otravy oxidem uhelnatým a/nebo úrazu elektrickým proudem.
Tento ohřívač smí používat nebo servisovat pouze osoby, které rozumí pokynům a dodržují je.
Pokud potřebujete pomoc nebo informace o topení, jako je návod k použití, štítky atd., obraťte se na místního prodejce Heat Wagon nebo na výrobce.
VAROVÁNÍ
Nebezpečí požáru, popálení, vdechnutí a výbuchu. Pevné hořlaviny, jako jsou stavební materiály, papír nebo lepenka, udržujte v bezpečné vzdálenosti od ohřívače, jak je doporučeno v pokynech. Nikdy nepoužívejte ohřívač v prostorách, které obsahují nebo mohou obsahovat těkavé nebo vzduchem přenášené hořlaviny nebo produkty jako benzín, rozpouštědla, ředidla barev, prachové částice nebo neznámé chemikálie.
Není určeno pro domácí použití nebo použití v rekreačních vozidlech!

Návod k instalaci a údržbě
Model 2730C/3050 Construction Heater
Obsah:
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P.a.g.4e Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Proper Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Hose Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Cord Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Sequence of Component Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Parts Breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-15 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-21
ZÁRUKA
All new Heat Wagon and Sure Flame heaters and fans are guaranteed against defective materials and workmanship for one (1) year from invoice date. Warranty repairs may be made only by an authorized, trained and certified Heat Wagon dealer. Warranty repairs by other entities will not be considered. Warranty claims must include model number and serial number.
OMEZENÍ
Warranty claims for service parts (wear parts) such as spark plugs, igniters, flame rods will not be allowed. Diagnostic parts such as voltage meters and pressure gauges are not warrantable. Evidence of improper fuel usage, fuel pressures outside of manufacturer’s specification, poor fuel quality, and improper electric power, misapplication or evidence of abuse may be cause for rejection of warranty claims. Travel time, mileage and shipping charges will not be allowed. Minor adjustments of heaters are dealers’ responsibility. Defective parts must be tagpo dobu 60 dnů od data opravy. Továrna poskytne povolení k vrácení zboží (RGA) pro vrácení vadných dílů. Na díly, které nebyly zakoupeny od Heat Wagon, nebude poskytnuta žádná záruka.
342 N. Co. Rd. 400 East · Valparaiso, IN 46383 219-464-8818 · 888-432-8924 · Fax 800-255-7985
www.heatwagon.com

VAROVÁNÍ – RIZIKO KVALITY VZDUCHU
· Do not use this heater for heating human living quarters. · Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO2 and NO2
considered to be hazardous to health and potentially life threatening. · Do not use in unventilated areas · Know the signs of CO and CO2 poisoning
– Headaches, stinging eyes – Dizziness, disorientation – Difficulty breathing, feels of being suffocated · Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustion and maintain acceptable air quality shall be provided in accordance with OSHA 29 CFR Part 1926.154, ANSI A10.10 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment used in the Construction Industry or the Natural Gas and Propane Installation Codes CSA B149.1 – Periodically monitor levels of CO, CO2 and NO2 existing at the construction site – at the minimum at the start of the
shift and after 4 hours. – Provide ventialtion air echange, either natural or mechanical, as required to maintain acceptable indoor air quality

USA 8hodinový časově vážený průměr (OSHA 29 CFR 1926.55 App A)

CO CO2 NO2

50 ppm 5000 ppm

Canada 8-hr time weighted average Worksafe BC OHS Guidelines Part 5.1 and Ontario Workplaces Reg 833
25 str./min 5000 str./min 3 str./min (reg. 833)

USA – Ceiling Limit (Short Term Exposure Limit = 15 minuntes)
CO CO2

NO2

5 ppm

Kanada STEL (15 minut reg. 833/1 hodina WSBC) WorkSafe BC OHS Guidelines Part 5.1 and Ontario Workplaces Reg 833
100 ppm 15000 ppm (WSBC) 30000 ppm (Reg 833) 1.0 ppm (WorkSafeBC) 5.0 ppm (reg 833)

· Ensure that the flow of combustion and ventilation air exchange cannot become obstructed. · As the building “tightens up” during the construction phases ventilation may need to be increased.

SPECIFIKACE

plyny:

Designed to ANZI Z83.7-1990 Standard Construction Heater

2730C Natural or Propane

3050 Natural or Propane

Kapacita:

2,000,000 Btu/h maximum

3,500,000 Btu/h maximum

Poznámka: Snížení vstupu pro nadmořskou výšku nad 2000 Ft. (609.6 M) o 4 % každých 1000 Ft. (304.8 m) nad mořem.

Velikost otvoru:

31 DMS (x125)

31 DMS (x125)

Ventilátor:

12,500 CFM; 3 HP; 2 In W.C.S.P.

16,000 CFM; 5 HP; 3 IN W.C.S.P.

Elektrické hodnocení:

240V 19 amps, Single Phase 240V 15 amps, Three Phase 480V 7 amps Three Phase

240V 30 amps, Single Phase 240V 20 amps, Three Phase 480V 10 amps, Three Phase

Minimum Temperature Rating:

Minus 40 Degrees F

Minus 40 Degrees F

Inlet Pressure Propane

250 Lbs. Max, 5 Lbs. Min.

Zásobování plynem

250 Lbs. Max, 5 Lbs. Min.

Manifold Pressure Propane

1″ WC

9.5″ WC

Inlet Pressure Natural Gas

250 Lbs. Max, 5 Lbs. Min.

10 Lbs. Max, 5 Lbs. Min.

Manifold Pressure Natural Gas

2.5″ WC

11″ WC

Liquid Propane Vapor Propane Natural Gas

Vstupní připojení

1/2″

1/2″

3/4″

3/4″

3/4″

1″

Max. Duct Length, Straight: 200′ at 27″ Diameter

300′ at 30″ Diameter

Hmotnost (přibližná)

440 liber

570 liber

4

INSTALACE
The Heat Wagon Model 2730/3050 is a direct fired gas heater intended to be used primarily for the temporary heating of building under construction, alteration, or repair. Since all the products of combustion are released into the area being heated, it is imperative that adequate ventilation is provided. The flow of supply air and combustion gases must not be obstructed in any way.
1. The heater is designed for indoor or outdoor installation in a horizontal position. Allow the following clearances from any combustible material or fuel containers. See page 6 for specifications
Also make sure that no flammable vapors are present in the space where the heaters is being used.
2. The heater should be inspected before each use, and at least annually by a qualified service person.
3. The hose assembly must be inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer. See parts list.
4. When connecting the heater to a natural gas or propane supply line ensure that the pressure at the heater inlet is within the specified range. Excessive pressure (over 250 psig) will damage the controls and void the warranty.
5. Connect the hose assembly to the heater gas inlet elbow. The elbow has a 3/4″ Female NPT thread. The hose assembly is supplied with a swivel connector to avoid kinking or twisting the hose. Use a minimum inside diameter of 1/2″ on LP, 3/4″ on vapor propane or 1″ on natural gas installations. Ensure that the hose assembly is protected from traffic, building materials, and contact with hot surfaces.
6. After installation, check hose assembly for gas leaks by applying a soap and water solution to each connection.
7. Connect the heater to an adequate electrical supply as specified on the rating plate. For protection against shock hazard the supply cord should be connected directly into a properly grounded fused disconnect.
8. Replacement parts are available from any Heat Wagon distributor or by calling 1-888-432-8924 for parts information.
5

MODEL 2730/3050
(NOTE: The 2730/3050 must be specifically set up for the type of available fuel PRIOR to installation) Model 3050 with built-in vaporizer. The heater will use 44 gallon of L.P. per hour. Use at least one 1000 gal. Liquid withdrawal tank. This will insure 20 hours of continuous operation.

When running unit on Liquid Propane, the heater

must be set up onside of the building, forcing the

heat through a building opening.

LARGE PROPANE STORAGE TANK VAPORIZATION RATE

·Hose size for Liquid Propane ­up to 25′ 3/8″ ID ­up to 50′ 1/2″ ID
Keep hose length as short as possible.

VELIKOST NÁDRŽE:
500 gallon 1000 gallon

MAXIMUM WITHDRAWAL RATE (BTUH):

40º

30º

20º

480,000 420,000 360,000 300,000

850,000 740,000 640,000 530,000

Model 3050, if setup for Vapor Propane withdraws 4,000,000 BTU’s per hour. Proper Tank sizing is essential. A propane tank can only make X amount of Vapor per hour. With drawing the vapor at a faster rate will frost the tank and eventually the burner will run out of fuel.

Hose sizing Vapor Propane ·Up to 100′, use 3/4″ or larger hose

For Natural Gas applications you must know the available line pressure and pipe inside diameter. Call the factory for the proper size of orifice, gas manifold and hose.

Vapor Propane and Natural Gas Units can be used inside the building or outside.

·Wire heater directly into fused disconnect

Power Supply line sizing:

3050 – 240V – under 75′

10ga.

75 stop až 100 stop

8 ga.

3050 – 480V – under 75′

14 ga.

75 stop až 150 stop

12 ga.

3 conductor 3 conductor 4 conductor 4 conductor

Position heater properly before use.

Install heater in a horizontal position. Clearances required for combustibles and containers.

Přední vývod

12 stop

Přívod

2 stop

Strany

2 stop

Nahoru

4 stop

For your safety do not use this heater in a space where gasoline or other liquids, having flammable vapors, are stored or used.

6

It is best to provide outside clean air to heater inlet and adequate ventilation to heated areas. The hose assembly shall be protected from traffic, damage, building materials and contact with hot surfaces.
Zkontrolujte těsnost všech spojů.
Turn off fuel supply and burn out leftover fuel in hose when heater is not in use.
Heater can be ducted up to 300 ft of straight 30″ for the 3050 and 200 ft of straight 27″ for the 2730C duct. For every 90° bend cut the total length in half.
If the heater is ducted it may be necessary to adjust the air flow switch (located inside control box) by turning adjusting screw CCW until the light on the control box turns on.
If the heater is equipped with a Hi/Lo Fire Thermostat, place the thermostat inside the area to be heated, then set desired temperature. Heater will cycle from high to low fire.

INSTALLATION USING A PROPANE SUPPLY TANK(S)
1) The propane supply system must be set up for vapor withdrawal from the operating tank(s). Liquid propane can cause the heater to overfire and will damage valve train components, unless unit is supplied with a built in vaporizer.

2) The heater must be at least 6 ft. from any LP-Gas container, and not directed toward any LP-Gas container with in 20 ft.

3) Minimum Tank Size 2 x 1000 Gal. 3 x 1000 Gal. 4 x 1000 Gal.

Outdoor Temperature Above +25°F +25°F to + 10° F Below +10°F

4) The installation must conform with local codes, or in the absence of local codes, with the Standard for Storage and Handling of Liquefied Petroleum Gasses ANSI/NFPA 58.

5) Turn off the propane supply valve at the tank(s) when the heater is not in use.

6) When the heater is to be stored indoors the propane tank(s) must be disconnected from the heater and the tank(s) stored in accordance with Chapter 5 of the above National Standard.

7

COMMON INSTALLATION AND OPERATIONAL PROBLEMS
1) LOW VOLTAGE AT THE HEATER This is one of the most common problems and is usually the result of the supply cord having too small a wire gauge for its length, or low voltage at the power source. Low voltage results in the motor overheating, burnt relay contacts, or a relay that will not make contact. Check voltmeter on heater before start-up.
2) SUPPLY LINE TOO SMALL Minimum Size: 1/2″ for LP, 3/4″ for Vapor Propane, 1″ for Natural Gas.
3) INSUFFICIENT VAPORIZATION AT SUPPLY Normally caused by undersized supply tank.
4) IMPROPER GAS SUPPLY PRESSURE Usually a result of propane supply pressure being too high because of improper or lack of regulation or too low of natural gas pressure at meter.
5) DIRTY GAS SUPPLY Dirty gas can cause strainers to plug or form a build-up in the burner orifice.
6) LACK OF PREVENTIVE MAINTENANCE Heaters must be cleaned as required, especially when used in a dirty environment.
7) IMPROPER SUPPLY OF FRESH AIR It is strongly recommended that the intake air of the heater be taken from outside the enclosed area. This provides a slight pressurization and prevents any problems associated with recirculation of products of combustion.
OPERATING INSTRUCTIONS Model 2730C / 3050
ON 1. Turn on fuel supply 2. Turn on the manual shut off valve 3. Turn on the fan switches 4. Turn on the burner switch.
OFF 1. Turn off fuel supply 2. Turn off the burner switch 3. Turn off the fan switch
8

MODEL 3050 SEQUENCE OF COMPONENT OPERATION
1) POWER SUPPLY 240/480 Volt wire directly into the fused disconnect.
2) FUSE DISCONNECT SWITCH Turned on, it sends power to motor relay and to control voltage transformátor.
3) CONTROL VOLTAGE TRANSFORMER Sends power to the 3 amp jistič.
4) 3 AMP CIRCUIT BREAKER Sends power to the fan switch.
5) FAN SWITCH Sends power to the motor relay holding coil.
6) MOTOR RELAY Closes, the fan motor starts, there is power at the burner switch.
7) BURNER SWITCH In the ON position it sends power to the air flow switch.
8) AIR FLOW SWITCH It was blown closed by the fan turning, sends power to the ignition control board.
9) IGNITION CONTROL BOARD Creates a spark at the igniter and sends power to the high limit switch.
10) HIGH LIMIT SWITCH Sends power to the gas solenoid valve.
11) GAS SOLENOID VALVE Opens, sending fuel to the burner (where there is spark).
12) BURNER It ignites.
13) IGNITER SENSOR
9

ODSTRAŇOVÁNÍ PROBLÉMŮ
NOTE: MUST CHECK COMPONENTS IN SEQUENCE LISTED
DIRECTIONS: Find the specific symptom. Refer to Sequence of component Operation Guide. Check the components listed with a voltmeter for proper operation as described. Replace any components not operating correctly.
Fan will not start when fan switch and thermostat are ON. · Check sequences 1 through 5 (Page 9) · Push reset button on Motor Overload Relay
Fan runs, no spark for ignition. · Check sequences 6 through 9 (Page 9) · Check continuity of igniter leads. Replace if shorted or broken. · Check igniter for carbon buildup, gap spacing (1/8″), secure mounting · Replace igniter if porcelain is cracked or if electrodes are rubbery
Have spark but no flame. · Check sequences 9 through 11 (Page 9) · Check for gas pressure on the manifold gauge, if gas is present, clean the burner port holes
Flame occurs but burner locks out after a few seconds. · Check burner ground wire (Bad connections) · Check sensor wire (Burned wire or bad connection) · Check igniter/sensor (Replace if probe is rubbery) · Clean port holes in burner around igniter/sensor · Replace ignition control board
Flame occurs but trips pressure reset button after 30 to 40 seconds. · Pressure regulator is set too high. · Limit switch shuts burner off. · Adjust pressure regulator to proper setting. (4″ W.C. LP Max, 4″ W.C. Nat. Max) · Indicator light will glow when proper setting is obtained.
Flame established, but too small. A: Check for proper pressure at manifold gauge — (if yes)
1. Clean port holes in burner
B: Not enough pressure at manifold gauge. 1. Check fuel supply 2. Check liquid strainer — Filter at the “Y” fitting. (Liquid Propane model only) for restriction from dirt, oil, etc. 3. Check high pressure regulator for similar restriction. 4. Check gas solenoid valve for similar restrictions.
10

MODEL 3050 PREVENTATIVE MAINTENANCE
1) Check – Fused disconnect A) Continuity through fuses.
2) Check – All wiring for tight and correct connections
3) Check – Motor Relay A) If it buzzes, clean contacts or replace. B) Check for voltage drop through L1 & T1 contacts. If it’s more than 2 volts replace.
4) Check – Air Flow Switch A) Clean inlet and negative pressure tubes (Blow out with air) B) Adjust the switch, turn adjusting screw CCW until the light on the control panel stays on.
5) Clean the burner A) Clean port holes (gas outlet) B) Clean air mixture holes (Main burner section)
6) Clean and inspect solenoid valves A) Remove tops of solenoid valves, clean dirt and propane oil out B) Inspect diaphragm (Not hard or cracked)
7) Check/Replace the igniter/sensor A) Move sensor probe with fingers. If “rubbery” replace it. B) If probe solidly rigid, clean igniter and check gap @ 1/8″
8) Check for gas leaks A) Heater operating, check for leaks at all pipe joints with leak detector or soapy water. Remake joints where bubbles occur.
9) Tighten all bolts A) Motor mounts B) Fan blade C) Burner mount D)Pipe train (manifold) mounts
ČIŠTĚNÍ
Heater housing may be cleaned with soap and water
· Place a plastic plug into the pipe inlet on valve train · Do not get the inside of control box wet · Allow heater to dry before connecting to power · Pay attention to decals so they remain legible
11

Model 2730C / 3050 Series

POLOŽKA 1 2 3 4
5
6
7
8
9 10 * * * * * *

PART# HWP HC1069B HWP HC1069A N/S HWP HP1049 HWP HP1049B HWP HG1050A HWP HG1050B HWP HM1056 HWP HM1066 HWP SM6162 HWP FM308 HWP HB1077 HWP HB1078 HWP HB2730 HWP HB3050 HWP HB1021B HWP HW1065 HWP HD1055 HWP HD1057 HWP HV1040 HWP HC1004B HWP HC1005 HWP HC1006

DESCRIPTION CONTROL BOX LID CONTROL BOX WITH LID COPPER TUBE/AIR SWITCH FAN BLADE 2730C FAN BLADE 3050 FAN GUARD 2730C FAN GUARD 3050 MOTOR 1 PHASE 2730C MOTOR 3 PHASE 2730C MOTOR 1 PHASE 3050 MOTOR 3 PHASE 3050 HEAT SHIELD 2730C HEAT SHIELD 3050 BODY 2730C BODY 3050 BURNER WHEEL, 12″ x 3″ x 5/8″ HUB FUSED DISCONNECT (SINGLE PHASE) FUSED DISCONNECT (THREE PHASE) VAPORIZER RING IGNITER (ASSEMBLY) IGNITION WIRE WITH FITTINGS FLAME DETECTION WIRE WITH FITTINGS

* Parts not shown on breakdown

12

Model 2730C / 3050 Series

POLOŽKA 1 2 3 4 5
6 7 8 9 10 11 12 13 14

PART# HWP HS1044 HWP HS1046B HWP HC1017 HWP HC1004B HWP HC1001C
HWP HC1010 SFP 2453 HWP HC1072 HWP HC1019B SFP 5989 HWP HC1011 HWP HC1011 SFP 2505 DES 099125-03

DESCRIPTION MOTOR RELAY OVERLOAD RELAY (3PH) CONTROL TRANSFORMER IGNITER (ASSEMBLY) D.S.I. CONTROL BOARD (for current wiring changes see page 16) AIR FLOW SWITCH HI-LO THERMOSTAT TIME DELAY BREAKER 3 AMP BREAKER VOLT METER (150 VOLTS) BURNER SWITCH FAN SWITCH LIGHT TERMINAL BLOCK

13

2730C / 3050 Liquid Pipe Train (with HI-LO Valve Installed)

POLOŽKA 1 2 3
4 5 6 7 8
9
11
13
14

PART# HWP HV1039 HWP HV1042B HWP HV1040 HWP HV1040B HWP HV1037 HWP HV1023 HWP HV1054 HW HV1029 HWP HV1029B HWP HV1129B SFP 2538 HWP HR1082 HWP HV20SV02B SFP 3455 HWP HV1076 HWP HV1076B HWP HV20SV02B HWP HR1082 HWP HV1169 SFP 4509

DESCRIPTION SAFETY RELIEF VALVE HOSE ASSEMBLY VAPORIZER RING 2730C VAPORIZER RING 3050 1/2″ SOLENOID VALVE L.P. 1/2″ VALVE MANUAL SHUT OFF 200 LB. LIQUID PRESSURE GAUGE 1/2″ STRAINER 3/4″ “Y” STRAINER 2730C 1″ “Y” STRAINER 3050 3/4″ BALL VALVE REGULATOR (1/8″ ORIFICE) 2730C REGULATOR 3050 3/4″ SOLENOID HI-LO SOLENOID (DRILLED AT 3/16″) 2730C HI-LO SOLENOID (DRILLED AT 1/4″) 3050 REGULATOR 2730C REGULATOR 3050 15″ W.C. GAUGE GAS PRESSURE LIMIT SWITCH

14

4
1

8
6 5 5

2730C / 3050 Natural Gas Pipe

POLOŽKA 1
2
3
5
6 7 8

PART# HWP HV1029B HWP HV1129B SFP 2538 HWP HV1035 HWP HR1082 SFP 3455 HV1032 HWP HV1076B HWP HV1032B HV20SV02B HWP HV1169 HWP 4509

DESCRIPTION 3/4″ “Y” STRAINER 2730C 1″ “Y” STRAINER 3050 3/4″ BALL VALVE 2730C 1″ BALL VALVE 3050 REGULATOR 2730C ONLY 3/4″ SOLENOID 2730C 1″ SOLENOID 3050 3/4″ SOLENOID HI-LO (DRILLED AT 1/4″) 1″ HI-LO SOLENOID (DRILLED AT 7/16″) REGULATOR 15″ W.C. GAUGE GAS PRESSURE LIMIT SWITCH

15

NEW HC1001C WIRING CHANGES The HC1001C Ignition Control (35-705505 Series board) also has a few changes from the old HC1001C. Since the HC1001C is used in so many applications, we will compare the old board to the new board (from left to right): (1) The “N/C” post on the HC1001C remains unused. (2) The “V1’s” on both boards stay the same. (3) The “L2’s” on both boards stay the same. (4) The “V2’s” on both boards stay the same. (5) The “L1’s” on both boards stay the same. (6) The “BGND” post on the new HC1001C holds the E2 wire (Flame Sensor) and the Burner Ground wire. (7) Reverse the Electrode wire and the Flame sensor wires on the Electrode Assembly. (8) Move old Burner Ground wire (1/4″ tab) to the open spot on the neutral terminal block.
480 voltů 3 PH
16

480 voltů 3 PH
17

240 voltů 3 PH
18

240 voltů 3 PH
19

240 voltů 1 PH
20

240 voltů 1 PH
21

22

23

342 N. Co. Rd. 400 East Valparaiso, IN 46383
219-464-8818 · Fax 219-462-7985 www.heatwagon.com

Dokumenty / zdroje

heat wagon 2730C,3050 Construction Heaters [pdf] Průvodce instalací
2730C, 3050, 2730C 3050 Construction Heaters, 2730C 3050, Construction Heaters, Heaters

Reference

Zanechte komentář

Vaše emailová adresa nebude zveřejněna. Povinná pole jsou označena *