Tesis Molino Analisis de Datos
Tesis Molino Analisis de Datos
Tesis Molino Analisis de Datos
ESCUELA DE POSGRADO
Arequipa – Perú
2019
i
AGRADECIMIENTOS
ii
DEDICATORIA
Dedico esta investigación a mis amados Sara, Emiliano y a mi padre que está
en el cielo.
iii
RESUMEN
iv
ABSTRACT
In the beginning of the 20th century, vertical mills have been introduced
massively in the cement industry, being high throughput machines and low
installation and operation costs than other grinding systems, for that reason
vertical mills are valuable to maximize the earnings of a cement plant.
In these days, the organizations have the duty to improve their processes
constantly; it can achieve good results focusing the efforts in the machinery
improvement, raw materials and supplies, energy and human resource
management.
To achieve the mentioned objective, it can focus the solution efforts by using a
variety of tools; one of these is Six Sigma, this method fundamentally is
supported by statistics and by a methodology called DMAIC (Define, measure,
analyze, improve and control).
Through the Six Sigma method which is going to be proposed, it will be able to
find which the factors that cause the low productivity are and then analyze them
to detail in order to find improvement solutions, being the main consequence
the increase of the cement plant profits.
v
ÍNDICE
AGRADECIMIENTOS ii
DEDICATORIA iii
RESUMEN iv
ABSTRACT v
ÍNDICE vi
1.1 Tema 2
1.2 Antecedentes 2
1.3 Problema por investigar 13
1.4 Justificación 16
1.5 Objetivos 16
1.5.1 Objetivo general 16
1.5.2 Objetivos específicos 16
1.6 Hipótesis 16
1.7 Variables 17
1.8 Definición conceptual y operacional de las variables 17
1.9 Tipo y diseño de la investigación 20
1.10 Metodología 20
1.11 Resumen de los capítulos 20
vi
2.2.3 Matriz QFD (Despliegue de la función calidad) 32
2.2.4 Histograma 33
2.2.5 Diagrama de Pareto 35
2.2.6 Diagrama de dispersión 36
2.2.7 Diagrama de Ishikawa 37
2.2.8 Ciclo PDCA 38
2.2.9 Mapa de procesos 39
2.2.10 Diagrama SIPOC 40
2.2.11 AMFE (Análisis de modos y efectos de falla) 40
2.2.12 Pruebas de hipótesis 45
2.2.13 Análisis de regresión y correlación 46
2.2.14 Análisis de varianza (ANOVA) 48
2.2.15 Estudio GAGE R & R 51
2.2.16 Prueba de normalidad Anderson – Darling 56
2.2.17 Prueba de igualdad de varianzas 58
2.2.18 Análisis de residuales 62
2.2.19 Gráfico de intervalos 62
2.2.20 Gráficos de control 63
2.2.21 Diseño de experimentos (DOE) 67
2.2.22 Gráfico de probabilidad normal de los efectos 74
2.2.23 Diagrama de efectos principales 75
2.2.24 Diagrama de cubo 76
2.3 Molinos verticales en la industria del cemento 77
2.3.1 Cemento portland 77
2.3.2 Adiciones 77
2.3.3 Puzolana 78
2.3.4 Cemento portland puzolánico 78
2.3.5 Proceso productivo del cemento 78
2.3.5.1 Extracción de materias primas 79
2.3.5.2 Triturado 79
2.3.5.3 Pre-homogenización de materias primas 80
2.3.5.4 Molienda de crudos y homogenización 81
vii
2.3.5.5 Producción de clinker 81
2.3.5.6 Molienda de cemento 83
2.3.5.7 Envase y despacho del cemento 83
2.3.6 Calidad en el proceso productivo del cemento 84
2.3.7 Molinos verticales de rodillos 88
2.3.8 Principio de funcionamiento de los molinos verticales de rodillos 89
2.3.9 Clasificación de los molinos verticales 96
2.3.9.1 Molino de anillos de bolas: Molino PETERS 96
2.3.9.2 Molino con rodillos abombados: Molinos MPS o PFEIFFER 97
2.3.9.3 Molino POLYSIUS 99
2.3.9.4 Molino ATOX – FLS 101
2.3.9.5 Molino LOESCHE 103
2.3.10 Equipos auxiliares de un molino vertical 106
2.3.10.1 Fajas transportadoras 107
2.3.10.2 Elevadores de cangilones 108
2.3.10.3 Canaletas aerodeslizantes 110
2.3.10.4 Balanzas dosificadoras 111
2.3.10.5 Válvula rotativa de sello 111
2.3.10.6 Filtros de mangas pulse jet 112
viii
3.2.10 Sistema de inyección de agua 126
3.2.11 Sistema hidráulico de los rodillos máster 127
3.2.12 Sistema de lubricación de los rodillos máster 129
3.2.13 Sistema de engrase del rocker arm de los rodillos máster 132
3.2.14 Sistema hidráulico de los rodillos esclavos 133
3.2.15 Sistema de lubricación del reductor RENK 134
3.2.16 Sistema de alta presión del reductor RENK 136
3.2.17 Circuito de filtración fina de aceite 138
3.2.18 Sistema de enfriamiento por agua 139
3.2.19 Clasificador dinámico 140
3.3 Producción de cemento en el molino vertical LM 56 2 + 2 CS 142
3.3.1 Producción de cemento en el mes 1 142
3.3.2 Producción de cemento en el mes 2 143
3.3.3 Producción de cemento en el mes 3 144
3.3.4 Producción de cemento en el mes 4 145
3.4 Indicadores de producción del cemento portland puzolánico 1P 147
3.5 Indicadores de producción del cemento portland puzolánico HE 152
3.6 Pérdida económica 168
ix
5.4 Desarrollo de la metodología DMAIC 188
5.4.1 Etapa definir 188
5.4.2 Etapa medir 193
5.4.3 Etapa analizar 199
5.4.3.1 Calidad del clinker 202
5.4.3.2 Temperatura del clinker 210
5.4.3.3 Flujo de gas 218
5.4.3.4 Flujo de agua 225
5.4.3.5 Velocidad del clasificador dinámico 232
5.4.3.6 Presión hidráulica de los rodillos 240
5.4.4 Etapa mejorar 249
5.4.4.1 Optimización de la temperatura del clinker 249
5.4.4.2 Optimización de los parámetros del proceso 257
5.4.5 Etapa controlar 266
5.5 Utilidad obtenida 279
CONCLUSIONES 287
RECOMENDACIONES 288
BIBLIOGRAFIA 289
ANEXOS 302
x
LISTA DE FIGURAS
xi
Figura 25: Gráfico de intervalos 63
Figura 30: ANOVA para un diseño factorial "2k" con "n" replicas 74
xii
Figura 50: Componentes estructurales de un elevador de cangilones 109
Figura 55: Diagrama de flujo del proceso del molino Loesche 56 2+2 CS 118
Figura 60: Mesa de molienda, armor ring, dam ring y nozzle ring 126
Figura 62: Componentes del sistema hidráulico de los rodillos máster 128
Figura 65: Puntos de engrase del rocker arm de los rodillos máster 132
Figura 69: Sistema de alta presión del reductor RENK parte 1 137
Figura 70: Sistema de alta presión del reductor RENK parte 2 138
xiii
Figura 75: Producción de cemento en el mes 2 144
xiv
Figura 100: Productividad con 131,53°C 211
Figura 112: Análisis de varianza del flujo de gas del molino 223
Figura 120: Análisis de varianza del flujo de agua del molino 230
xv
Figura 125: Productividad con 97 rpm 234
xvi
LISTA DE TABLAS
xvii
Tabla 25: Parámetros operacionales para el cemento portland HE día 5 164
xviii
Tabla 50: Plan de mantenimiento predictivo para el sistema hidráulico 276
xix
LISTA DE FÓRMULAS
Fórmula 5: Índice Z 29
xx
Fórmula 25: Porcentaje de reproducibilidad 55
xxi
Fórmula 50: Suma de cuadrados total 71
Fórmula 51: Suma de cuadrados del error "4(n-1) " grados de libertad 71
xxii
LISTA DE ANEXOS
Anexo 11: Dosificación de materias primas para los cementos portland 310
Anexo 12: Lista de costos y precios aproximados del cemento portland 310
Anexo 14: Encuesta sobre la baja productividad del molino vertical 311
Anexo 15: Parámetros de calidad del clinker y productividad del molino 312
xxiii
Anexo 25: Productividad a una velocidad promedio de 103 rpm 322
Anexo 37: Experimento considerando 1100 litros/h, 100 rpm y 97 BAR 334
Anexo 38: Experimento considerando 1500 litros/h, 100 rpm y 97 BAR 335
Anexo 39: Experimento considerando 1100 litros/h, 103 rpm y 97 BAR 336
Anexo 40: Experimento considerando 1500 litros/h, 103 rpm y 97 BAR 337
Anexo 41: Experimento considerando 1100 litros/h, 100 rpm y 102 BAR 338
Anexo 42: Experimento considerando 1500 litros/h, 100 rpm y 102 BAR 339
Anexo 43: Experimento considerando 1100 litros/h, 103 rpm y 102 BAR 340
Anexo 44: Experimento considerando 1500 litros/h, 103 rpm y 102 BAR 341
Anexo 45: Averías de los equipos del transporte de materias primas 342
xxiv
LISTA DE ABERVIATURAS
CS – Clinker y escoria.
EP – Estadístico de prueba.
FL – Fase líquida.
xxv
KW – Kilovatio.
LM – Molino Loesche.
MF – Módulo de alúmina.
MS – Módulo de sílice.
SA – Sociedad anónima.
TM – Toneladas métricas.
xxvi
CAPÍTULO I
PLANTEAMIENTO METODOLÓGICO
1
PLANTEAMIENTO METODOLÓGICO
1.1 Tema
1.2 Antecedentes
Desde antes del siglo XVIII, se lograron avances en la tecnología de fabricación del
cemento hasta llegar a los diferentes tipos de cemento portland que se conocen hoy
en día. La historia del cemento portland, según IECA (2015) se muestra en la tabla 1.
2
mejoraba las resistencias
frente a la acción del agua
del mar.
Año 1817 Louis Vicat (Francia) Propuso el primer sistema
de fabricación del cemento
por vía húmeda.
Año 1824 Joseph Aspdin Patentó el nombre de
(Inglaterra) cemento portland debido a
que usaba un material
polvoriento que amasado
con agua y con arena se
endurecía formando un
conglomerado parecido a
las calizas de la isla de
Portland.
Año 1838 Isambard Brunel Emplea por primera vez un
(Inglaterra) cemento procedente de la
fábrica de Aspdin. Este
cemento se aplicó en la
construcción de un túnel
bajo el río Támesis en
Londres.
Año 1845 Isaac Johnson Produjo el prototipo del
(Inglaterra) cemento moderno a escala
industrial, el cual logra
conseguir temperaturas
suficientemente altas para
clinkerizar a la mezcla de
arcilla y caliza empleada
como materia prima.
Año 1853 Louis Vicat (Francia) Estudio de la acción
destructiva del agua de mar
3
sobre el mortero y
hormigón.
Fuente: Elaboración propia en base a los aportes de IECA, 2015
"Es a partir de 1900 cuando los cementos portland se imponen en las obras de
ingeniería y cuando empieza un descenso veloz del consumo de cementos naturales".
(IECA 2015).
En los inicios del siglo XX, se empieza con la producción de cemento portland en el
Perú y en la tabla 2 se muestra cómo es que se llevó a cabo.
Desde que se instalaron las primeras plantas de cemento en el Perú, se han ido
incorporando nuevas tecnologías de fabricación de cemento, Gonzáles (1997)
menciona los siguientes avances en nuestro país:
4
Década de 1960: Se adoptó la tecnología de silos de homogenización continua,
llevando a otras plantas al denominado proceso seco. Se incorporó el sistema
de calentamiento del crudo previo a su ingreso al horno aprovechando sus
gases residuales.
Década de 1970: Se agregó la calcinación del crudo, que con las mejoras
introducidas anteriormente colocaron a la industria en buena posición frente a
la crisis de petróleo de 1974. Se introducen equipos de gran capacidad como el
horno de 1 000 000 de TM/año y molinos de 200 TM/año.
Década de 1980: Se inicia la sustitución del petróleo por el carbón mineral
como combustible.
De 1990 en adelante: Se han incrementado las capacidades de los equipos,
como hornos de 2 000 000 de TM/año, nuevos sistemas de molienda como
molinos verticales de rodillos y los clasificadores de partículas de alta
eficiencia.
La industria del cemento ha seguido desde sus inicios las normas de la Sociedad
Americana de Ensayos y Materiales (ASTM) y las Normas Técnicas Peruanas (NTP).
(Gonzáles 1997).
5
El sector de la construcción en el Perú hasta el 2013, ha sido favorable para la
industria cementera, según FICEM (2013), se debe a los siguientes factores:
6
Los países que más han producido cemento en 2012 son Brasil, Colombia y
Argentina. Perú pasó de un crecimiento de 2,42% en 2011 a uno de 15,86% en 2012.
Según FICEM (2013), "en 2012 los países con un crecimiento en el consumo de
cemento superior al 10% fueron Panamá, Perú y Chile. En 2011, el grupo de países
que superaron ese 10% fue mayor (Haití, Nicaragua, Uruguay, Colombia, Chile,
Panamá y Argentina)".
En el caso de Perú, este pasó del 4,03% (2011) al 15,14% en 2012. En la figura 3 se
observa el consumo de cemento en América latina y el Caribe.
7
Figura 3: Consumo de cemento (En miles de toneladas)
Alcántara (2008), indica que "la molienda es una operación unitaria, que reduce el
volumen promedio de las partículas de una muestra sólida. La reducción se lleva a
cabo dividiendo o fraccionando la muestra por medios mecánicos hasta el tamaño
deseado".
8
"Los métodos de reducción más empleados en las máquinas de molienda son
compresión, impacto, cizallamiento y cortado". (Alcántara 2008).
Duda (1977), menciona que "la molienda de clinker para cemento es uno de los
procesos principales y, al mismo tiempo, el final de las operaciones tecnológicas en la
fabricación de cemento".
Las máquinas de molienda más usadas en la industria cementera son las trituradoras,
los molinos de bolas y los molinos verticales de rodillos.
Según Raeber et al. (s.f.), los molinos verticales de rodillos son ampliamente
aceptados como el medio más eficiente de molienda de crudo y clinker. Ellos son
capaces de moler una amplia gama de materiales con la fineza requerida, usando un
proceso eficiente en cuanto a producción y energía.
9
Figura 4: Incremento de capacidad y potencia de los molinos verticales
Jung (2000), menciona que el alto grado de utilización de estos molinos es debido,
principalmente, a la realización combinada de varias etapas del proceso dentro de la
misma máquina, al reducido consumo de energía eléctrica y al aprovechamiento de
grandes cantidades de gases del proceso.
Según Simmons et al. (2005), los molinos verticales de rodillos ofrecen bastantes
beneficios comparados con los molinos de bolas en cuanto a costos operativos y
flexibilidad.
10
EDGE; el primero de origen hispano y el segundo de origen chino, ambos
arrastrados por asnos.
A principios del siglo XIX las piedras fueron sustituidas por acero y se llamaron
molinos CHILEAN. De aquellos surgieron infinidad de modelos utilizados en el
siglo XIX. El HUNGTINGTONG (1883), MAXECON (1989), RAIMOND y
FULLER. Consistían fundamentalmente en una mesa circular fija y uno o varios
rodillos móviles. Todos ellos fueron la inspiración de las actuales compañías
suministradoras de equipos para fabricar los actuales molinos verticales.
En 1895 aparece el primer molino vertical desarrollado por Loesche usado para
la molienda de carbón en plantas de energía en Berlín.
En 1925 Loesche hizo la innovación más importante al dejar los rodillos fijos y
la mesa móvil; muy apropiada para la industria cementera por la facilidad de
secar las materias primas y su bajo coste energético.
En 1935 se pone en funcionamiento el primer molino Loesche LM 11 para la
molienda de Clinker en Brasil, en 1985 se instalaron molinos en Asia para la
molienda de Clinker y escoria de alto horno.
En 1994 se aplica por primera vez la tecnología 2 + 2 en un LM 46 2 + 2 para la
molienda de Clinker en Taiwán.
En 2005 se pone en funcionamiento el primer molino con tecnología 3 + 3 en
un LM 56 3 + 3 para la molienda de Clinker en India.
11
Figura 5: Molino vertical Loesche de 1929
Los molinos verticales son diseñados para producir distintos tipos de cementos
portland, entre ellos, los cementos portland adicionados, los cuales han adquirido
mucha importancia en los últimos años en la industria peruana por el ahorro que
ofrecen al utilizar menor cantidad de clinker.
Salamanca (2000), indica que "los cementos adicionados, son mezclas de clinker de
cemento portland, sulfato de calcio (yesos) y adiciones minerales; estos cementos
pueden ser producidos por molienda conjunta de estos componentes o por la mezcla
de los componentes finamente molidos".
12
Según Salamanca (2000), la producción de cementos adicionados se ha venido
incrementando en todo el mundo por múltiples razones:
Las adiciones minerales en los cementos pueden ser puzolanas con diferentes
características fisicoquímicas, minerales ricos en calcio, escorias de alto horno, entre
otros.
Labahn (1966), indica que las puzolanas son materiales que reaccionan con el
hidróxido de calcio a temperaturas ordinarias, dando como resultado productos
capaces de desarrollar resistencias (endurecimiento hidráulico).
La productividad de los molinos verticales de cemento varía entre 100 a 300 TM/h,
esto depende del diseño del fabricante y de la necesidad de la planta de cemento.
13
En general, la productividad depende de qué tipo de cemento se va a producir, qué
materias primas se van a utilizar, las características físicas y químicas de estas
materias primas y en qué cantidad se van a dosificar al molino.
Teniendo en cuenta los factores de diseño, los molinos llegan a producir su capacidad
máxima sin dificultades, en el caso de la empresa se tiene el molino vertical LM 56 2 +
2 CS de 180 TM/h diseñado para producir cemento portland puzolánico tipo 1P.
Para optimizar los procesos de una organización existen diversos enfoques, uno de
ellos es el Seis Sigma.
Sánchez (2005), indica que el Seis Sigma "es un sistema completo y flexible para
conseguir, mantener y maximizar el éxito en los negocios".
14
atención constante a la gestión, mejora y reinvención de los procesos empresariales".
(Sánchez 2005).
Santivañez (2014), menciona que el Seis Sigma es "una estrategia para la mejora de
la calidad e incremento de la productividad. Sus esfuerzos se dirigen a mejorar la
satisfacción del cliente, reducir el tiempo de ciclo y reducir los defectos".
Siendo una de las premisas del Seis Sigma la mejora de los procesos, entonces con
este método se podrían identificar las causas de la baja productividad del molino,
luego las variables que están relacionadas con esta; y finalmente poder plantear las
mejoras pertinentes que permitan producir nuevamente 180 TM/h.
15
1.4 Justificación
1.5 Objetivos
1.6 Hipótesis
16
1.7 Variables
17
Tabla 4: Definición operativa de la variable independiente
18
Tabla 5: Definición operativa de variable dependiente
19
1.9 Tipo y diseño de la investigación
1.10 Metodología
20
Capítulo III: Diagnóstico situacional del molino LM 56 2 + 2 CS.
Capítulo IV: Propuesta del método.
Capítulo V: Validación del método.
Capítulo VI: Evaluación del método.
21
CAPÍTULO II
MARCO TEÓRICO
22
MARCO TEÓRICO
En este capítulo se va a mencionar la teoría del Seis Sigma, luego se van a detallar
las herramientas cualitativas y cuantitativas que este método utiliza y finalmente se va a
desarrollar la teoría de los molinos verticales en la industria del cemento.
El Seis Sigma "es una estrategia para mejorar la calidad de procesos mediante la
identificación y eliminación de defectos y la minimización de la variación de los
resultados del proceso". (MIT 2012).
Prieto (2008), indica que el Seis Sigma "es una estrategia de negocio y de mejora
continua que busca encontrar y eliminar causas de errores o defectos en los
procesos, enfocándose a las variables de importancia crítica para los consumidores".
Según Carro y Gonzales (2008), Seis Sigma "es una estrategia para el aumento de la
competitividad a través de la mejora continua de la calidad, con énfasis en la
aplicación de herramientas estadísticas para la eliminación de defectos".
23
estadísticas para la solución de problemas.
No se tiene soporte en la aplicación de las Se provee toda una estructura de apoyo y
herramientas de mejora. Su uso es capacitación al personal, para el empleo de
localizado y aislado. herramientas de mejora.
La toma de decisiones se efectúa sobre la La toma de decisiones se basa en datos
base de presentimientos y datos vagos. precisos y objetivos.
Se aplican remedios provisionales o Se va a la causa raíz para implementar
parches. Solo se corrige en vez de soluciones sólidas y efectivas y así prevenir
prevenir. la ocurrencia de los problemas.
No se establecen planes estructurados de Se establecen planes de entrenamiento
formación y capacitación para la aplicación estructurados para la aplicación de las
de las técnicas estadísticas requeridas. técnicas estadísticas requeridas.
Se enfoca solamente en la inspección para Se enfoca hacia el control de las variables
la detección de los defectos (variables claves de entrada al proceso, las cuales
clave de salida del proceso). generan la salida o producto deseado del
proceso.
Fuente: Gómez, (como se citó en Sánchez, 2005)
Según Harry et al. (Como se citó en Gutiérrez y de la Vara, 2013) el Seis Sigma "es
una estrategia de mejora continua del negocio, que tiene diferentes significados para
diferentes grupos dentro de una organización":
A nivel empresa, es una iniciativa estratégica que busca alcanzar una mejora
significativa en el crecimiento del negocio, su capacidad y en la satisfacción de
los clientes.
A nivel operacional, tiene una naturaleza táctica que se enfoca a mejorar
métricas de eficiencia operacional, como tiempos de entrega, costos de no
calidad y defectos por unidad.
A nivel proceso, es utilizada para reducir la variabilidad, y con ello es posible
encontrar y eliminar las causas de los errores, defectos y retrasos en los
procesos de negocio, así como disminuir los costos directos.
24
De acuerdo con las definiciones presentadas se puede decir que Seis Sigma es una
estrategia para mejorar los procesos empresariales mediante el uso de herramientas
de análisis y estadísticas que apuntan hacia la mejora continua.
25
2.1.2 Métricas Seis Sigma
"Sigma (σ), es la letra griega que se usa para denotar la desviación estándar
poblacional (proceso), la cual proporciona una forma de cuantificar la variación".
(Gutiérrez y de la Vara 2013).
El nivel sigma que tiene un proceso es una forma de describir que tan bien la
variación del proceso cumple las especificaciones del cliente. La meta ideal es
que el proceso tenga un nivel de calidad Seis Sigma. (Gutiérrez y de la Vara
2013).
Ávila (2006), indica que por lo general muchos procesos tienden a distribuirse
normalmente lo cual origina gráficamente una curva simétrica con forma de
campana conocida como campana de Gauss.
26
Según los estudios realizados por Motorola, la mayoría de los procesos a través
del tiempo, varían en 1.5 "σ" de la media debido a causas aleatorias, tales como
el material utilizado, recursos humanos, etc.; sin embargo, debe mantenerse
dentro de los límites de especificación para no defraudar a los clientes. (Ávila
2006).
(1)
Dónde:
27
σ: Desviación estándar del proceso.
(2)
Dónde:
28
Índice de capacidad de largo plazo (Pp): Indicador del desempeño
potencial del proceso, se calcula con la desviación estándar de largo
plazo. (Gutiérrez y de la Vara 2013).
(3)
(4)
29
En la tabla 8 se observa un resumen de la calidad a corto y a largo plazo
en términos de capacidad del proceso.
El Seis Sigma utiliza una metodología de cinco etapas, las cuales son: definir,
medir, analizar, mejorar y controlar.
30
realizar la validación de la mejora a través de una medición actual de la
capacidad". (Barahona y Navarro 2013).
Controlar: "Consiste en controlar y dar seguimiento al proceso. Una vez
que el proceso es capaz, se deberán buscar mejores condiciones de
operación, materiales, procedimientos, etc., que conduzcan a un mejor
desempeño del proceso". (Barahona y Navarro 2013).
Vázquez (2005), indica que la voz del cliente es una estrategia para aprender
sobre los clientes a través de la recolección de datos de diferentes fuentes, que
incluye:
31
2.2.3 Matriz QFD (Despliegue de la función calidad)
Gutiérrez y de la Vara (2013) indican que la matriz QDF "es una herramienta
de planeación que introduce la voz del cliente en el desarrollo de un producto o
proyecto".
32
Figura 10: Matriz QFD
2.2.4 Histograma
Sánchez, 2005
33
Según Sáez (2012) para realizar un histograma se siguen los siguientes pasos:
R = xM – xm
(6)
L = R/N
(7)
(8)
Para cada intervalo se cuenta el número de datos que hay en él, es decir
la frecuencia del intervalo.
34
En el eje "X" se colocan los intervalos y sobre ellos se construyen barras
cuya altura sea la frecuencia o la frecuencia relativa del intervalo.
La ley de Pareto (80-20), indica que pocos elementos (20%) generan la mayor
parte del efecto (80%), y el resto de los elementos proporcionan muy poco del
efecto total. El nombre del principio se determinó en honor al economista Italiano
Wilfredo Pareto (1843-1923). (Gutiérrez y de la Vara 2013).
Domenech (s.f.), menciona que los pasos para realizar un diagrama de Pareto
son:
35
Investigar los factores o causas que provocan ese problema y como
recoger los datos referentes a ellos.
Anotar la magnitud de cada factor.
Ordenar los factores de mayor a menor en función de la magnitud de cada
uno de ellos.
Calcular la magnitud total del conjunto de factores.
Calcular el porcentaje total que representa cada factor, así como el
porcentaje acumulado.
Dibujar dos ejes verticales y un eje horizontal.
Situar en el eje vertical izquierdo la magnitud de cada factor. La escala del
eje está comprendida entre 0 y la magnitud total de los factores.
En el eje derecho se presenta el porcentaje acumulado de los factores,
por tanto, la escala es de 0 a 100.
En el eje horizontal se muestran los factores empezando por el de mayor
importancia.
"Un alineamiento de los puntos de manera clara y con una dirección bien
definida significa que la relación es fuerte entre las dos variables. El grado de
relación empieza a debilitarse a medida que dicha nube de puntos se hace más
dispersa". (Barahona y Navarro 2013).
36
Figura 13: Tipos de relación entre variables
Se debe tener en cuenta las "6M", que influyen en la variación del gráfico, y son
las máquinas, los métodos, materiales, mediciones, el medio ambiente y la mano
de obra. (Gutiérrez y de la Vara 2013).
37
Figura 15: Diagrama de Ishikawa
38
2.2.9 Mapa de procesos
Para realizar un mapa de procesos primero se deben tener en cuenta los tipos
de procesos, los cuales son detallados a continuación por Ñopo y Salas (2014):
39
A veces para especificar procesos, resulta útil el concepto de descomposición
funcional mediante el cual se puede subdividir en varios niveles de detalle para
mayor especificación. (Ñopo y Salas 2014).
40
"Estas fallas se jerarquizan, y para aquellas que vulneran más la confiabilidad
del producto o el proceso, será necesario generar acciones para eliminarlas o
reducir el riesgo asociado con las mismas". (Gutiérrez y de la Vara 2013).
Para evaluar el impacto de los modos y efectos de falla se usan los siguientes
criterios: (Gutiérrez y de la Vara 2013).
NPR = S*O*D
(9)
41
Tabla 9: Criterios para la evaluación de severidad
Efecto Severidad (efecto sobre el cliente) Puntuación Efecto Severidad (efecto sobre la manufactura)
Incumplimiento de Impacto en la operación segura del producto o involucra 10 Incumplimiento de los Puede poner en peligro el operador (maquina o ensamble) sin previo
los requerimientos incumplimiento de regulaciones gubernamentales sin previo requerimientos de aviso.
de seguridad aviso. seguridad o
Impacto en la operación segura del producto o involucra 9 reglamentarios. Puede poner en peligro el operador (maquina o ensamble) con previo
incumplimiento de regulaciones gubernamentales con previo aviso.
aviso.
Perdida de la Perdida de la función primaria (producto inoperable, no afecta 8 Trastorno o afectación El 100% del producto puede que tenga que desecharse. Paro de la
función primaria la operación segura del producto). mayor. línea de producción o del embarque.
Degradación de la función primaria (producto operable, pero 7 Trastorno o afectación Una parte de la producción puede que tenga que desecharse. El efecto
hay reducción en el nivel de desempeño). significativa. sobre el proceso principal incluye la disminución de la velocidad de la
línea o el que se tenga que agregar más operadores.
Perdida de la Perdida de función secundaria (producto operable, pero las 6 Trastorno o afectación El 100% de la producción puede que tenga que ser reprocesada fuera
función secundaria funciones de confort o comodidad son inoperables). moderada. de la línea de producción para luego ser aceptada.
Degradación de función secundaria (producto operable, pero 5 Una parte de la producción puede que tenga que ser reprocesada fuera
hay reducción del nivel de desempeño de las funciones de de la línea de producción para luego ser aceptada.
confort o comodidad).
Molestia Apariencia o ruido audible, producto operable, parte no 4 El 100% de la producción puede que tenga que ser reprocesada en la
conforme y es percibido por la mayoría de los clientes (más estación de trabajo antes de que esta sea reprocesada.
de 75%).
Apariencia o ruido audible, producto operable, parte no 3 Una parte de la producción puede que tenga que ser reprocesada en la
conforme y es percibido por muchos clientes (50%). estación de trabajo antes de que sea reprocesada.
Apariencia o ruido audible, producto operable, parte no 2 Trastorno o afectación Ligeros inconvenientes para el proceso, operación u operador.
conforme y es percibido por clientes más perspicaces (25%). menor.
Ningún efecto Ningún efecto perceptible para el cliente. 1 Ningún efecto Ningún efecto perceptible.
42
Tabla 10: Criterios para la evaluación de ocurrencia
43
Tabla 11: Criterios para la evaluación de detección
Oportunidad de detección Posibilidad de detección por los controles del proceso Puntuación Posibilidad de
detección
Ninguna oportunidad de detección Actualmente no hay controles del proceso, no se puede detectar o no es analizado. 10 Casi imposible
No es probable detectar en cualquier El modo de falla y/o la causa (error) no son fácilmente detectados 9 Muy remota
etapa
Detección del problema después del El modo de falla se detecta en la estación de trabajo por el operador a través de los sentidos vista, 8 Remota
procesamiento olfato u oído.
Detección del problema en la fuente El modo de falla se detecta en la estación de trabajo por el operador a través de los sentidos vista, 7 Muy baja
olfato u oído, o bien después de la producción a través del uso de instrumentos que miden
atributos (pasa/no pasa, verificación manual del torque, llaves graduadas, etc.)
Detección del problema después del El modo de falla se detecta por el operador después del proceso a través de equipos de 6 Baja
procesamiento mediciones continuas, o en la estación de trabajo a través del uso de instrumentos que miden
atributos (pasa/no pasa, verificación manual del torque, llaves graduadas, etc.)
Detección del problema en la fuente El modo de falla o la causa del error se detectan en la estación de trabajo por el operador 5 Moderada
mediante equipos de mediciones continuas, o mediante controles automáticos en la estación de
trabajo que identifican las partes discrepantes y notifican al operador (luz, sonidos, etc.). Se
realizan mediciones al arranque y la primera pieza se verifica (solo para causas relacionadas con
el arranque).
Detección del problema después del El modo de falla se detecta después del proceso mediante controles automáticos que identifican 4 Moderadamente
procesamiento las partes discrepantes y bloquean la parte para prevenir el que no se procese posteriormente. alta
Detección del problema en la fuente El modo de falla se detecta en la estación de trabajo mediante controles automáticos que 3 Alta
identifican las partes discrepantes y bloquean la parte para prevenir el que no se procese
posteriormente
Detección del error y/o prevención Se detecta la causa (error) de la falla en la estación de trabajo por controles automáticos que 2 Muy alta
del problema detectarían errores y previenen que se hagan partes discrepantes.
No se aplica detección, se previene Se previene la causa (error) de la falla como resultado del diseño del accesorio, la maquina o 1 Casi segura
el error parte. No se pueden hacer partes discrepantes porque se tiene un diseño de producto/proceso a
prueba de errores.
44
2.2.12 Pruebas de hipótesis
Un valor "p" oscila entre 0 y 1. El valor "p" es una probabilidad que mide la
evidencia en contra de la hipótesis nula. (MINITAB 2016).
Se compara el valor "p" con el nivel de significancia (α) para decidir si debe
rechazar la hipótesis nula (H0): (MINITAB 2016).
45
Si el valor "p" es mayor que el nivel de significancia (α), no se rechaza
"H0".
Para el nivel de significancia (α) suele utilizarse un valor de 0,05.
(10)
(11)
46
(12)
Dónde:
X e Y: Variables numéricas.
Xi e Yi: Valores para las variables X e Y.
: Promedios de Xi y de Yi respectivamente.
n: Número de pares de observaciones de Xi e Yi respectivamente.
(13)
Dónde:
Ŷ = Variable dependiente.
a= Ordenada "y".
Xk = Valores de las variables independientes.
Bk = Pendientes asociadas con "Xk".
(14)
47
Cuando hay más de dos variables es recomendable usar un software para
realizar los cálculos y obtener la ecuación de la regresión. (Levin y Rubin 2010).
(15)
Cuanto más cercano el valor está a +/- 1, mejor es el ajuste lineal. + 1 indica que
un perfecto ajuste con una pendiente positiva, mientras que – 1 indica un ajuste
perfecto con una pendiente negativa. (Díaz y Ruiz s.f.).
48
"El contraste de la igualdad de las medias poblacionales se basa en una
comparación de dos tipos de variabilidad de los miembros de la muestra".
(Newbold et al. 2008).
Dónde:
Para obtener estas estimaciones, deben dividirse las sumas de los cuadrados
por el número correspondiente de grados de libertad, y se obtienen las medias
de los cuadrados "MCG" y "MCD" para cada fuente de variación. (Newbold et al.
2008).
49
Figura 20: Media de los cuadrados
(16)
50
Adicionalmente se puede calcular el análisis de la varianza con MINITAB
interpretando el valor de "p".
51
Botero et al. (Como se citó en Ruiz y Montañez, 2011) indican que "el método
del análisis de varianza es el más exacto para calcular la variabilidad de un
sistema de medición porque posee la ventaja de cuantificar la variación debida a
la interacción entre los operadores y las partes".
Dónde:
a: Número de operadores.
b: Número de partes.
n: Número de medidas para cada parte por cada operador.
N: Número total de datos.
Según Botero et al. (Como se citó en Ruiz y Montañez, 2011) los pasos a seguir
para realizar la tabla ANOVA de dos factores son:
(17)
52
Dónde "Xijk" son cada uno de los datos de los experimentos.
(18)
(19)
(20)
53
(21)
(22)
(23)
54
(24)
(25)
(26)
(27)
55
Dónde "T" es la tolerancia de la característica medida.
(28)
(29)
Según Botero et al. (Como se citó en Ruiz y Montañez, 2011) para interpretar los
resultados obtenidos se aplican los siguientes criterios:
56
"Evaluar la normalidad de los datos es importante porque las herramientas
estadísticas para el estudio de los procesos se basan en una distribución
normal". (Argüelles 2014).
Para calcular si los datos siguen una distribución normal, Salgado (s.f.), presenta
la hipótesis y el estadístico de prueba que están descritos a continuación:
(30)
Dónde:
n: Número de observaciones.
F (y): Distribución de probabilidades acumulada normal con media y varianza
especificadas a partir de la muestra.
Yi: Datos obtenidos de la muestra de menor a mayor.
57
Cuando no se cumple con la normalidad de los datos, estos pueden
transformarse a datos normales usando el método de Box – Cox. Esto se hace
mediante la transformación de potencia definida como: (Gutiérrez y de la Vara
2013).
(31)
(32)
58
Para calcular el estadístico de Bartlett se tiene la siguiente fórmula: (Flores
2015).
(33)
Dónde:
(34)
59
Dónde:
k = Número de muestras.
ni = Tamaño de la i-ésima muestra.
N = Tamaño total (sumatoria de las muestras).
Zij = (Xij – i), donde i es la media del i-ésimo subgrupo.
= Media global de Zij.
i = Media del i-ésimo subgrupo de los Zij.
Grados de libertad = k-1.
La prueba de Levene rechaza la hipótesis (H0) referida a que las varianzas son
iguales con un nivel de significancia "α" si "W > Fα, k-1, n-k". (Correa et al. 2006).
Dónde:
"Fα, k-1, n-k" es el valor crítico de la distribución F con "k-1" grados de libertad en
el numerador y "n-k" grados de libertad en el denominador a un nivel de
significancia "α". (Correa et al. 2006). La distribución F se encuentra en el anexo
1.
60
"El agregado de Welch consiste en una ecuación para calcular los grados de
libertad de manera que disminuye el error por la no homogeneidad de varianzas.
(Eche 2016)".
(35)
Dónde:
(36)
61
2.2.18 Análisis de residuales
62
"La gráfica de intervalos predeterminada muestra un símbolo de la media con
una barra de intervalos de confianza de 95%. Las gráficas de intervalos son
útiles especialmente para comparar grupos". (MINITAB 2016).
"Es una herramienta estadística que consiste en una línea central que indica
el promedio de los datos analizados, dos líneas laterales que señalan los
límites de control y una serie de puntos que representan los valores de los
datos". (Argüelles 2014).
Existen dos clases de gráficos, los gráficos de control por variables que
permiten estudiar variables numéricas de un proceso, es decir características
cuantitativas y los gráficos de control por atributos que estudian variables
cualitativas de un proceso. (Argüelles 2014).
63
Figura 26: Clasificación de gráficos de control por variables
64
Hernández (2005), presenta los cálculos para construir la gráfica -R:
(37)
(38)
(39)
Donde "D4", "D3", "A2" son constantes que varían según el tamaño de muestra.
(40)
65
(41)
(42)
Dónde:
k = número de subgrupos.
N = número de muestras en cada subgrupo.
X = promedio para un subgrupo.
X = promedio de todos los promedios de los subgrupos.
S = Desviación estándar de un subgrupo.
S = Desviación estándar promedio de todos los subgrupos.
(43)
66
Dónde:
"Es un método estructurado que permite atacar los factores que contribuyen
a mayores porcentajes de variación de un proceso, analizándolos en conjunto o
por separado". (Argüelles 2014).
67
Factor: Es aquella variable de interés cuyo posible efecto sobre la
respuesta se quiere estudiar.
Niveles de un factor: Son los tipos o grados específicos del factor que se
tiene en cuenta en la realización del experimento.
Tratamientos: Es una combinación de niveles de todos los factores.
Error: Indica como es determinada situación cuando no se obtienen
resultados idénticos cuando dos unidades son tratadas igualmente.
El primer diseño de la serie "2k" es el que tiene dos factores, cada uno se corre
a dos niveles. A este diseño se le llama diseño factorial 2 2. Los niveles de los
factores pueden denominarse arbitrariamente bajo y alto. (Montgomery 2004).
El efecto de un factor se denota con una letra mayúscula latina. Por lo tanto "A"
se refiere al efecto del factor A, "B" al efecto del factor B y "AB" a la interacción
AB. (Montgomery 2004).
68
En el diseño 22, los niveles alto y bajo de "A" y "B" se denotan por "–" y "+"
respectivamente, en los ejes "A" y "B". Las cuatro combinaciones de
tratamientos suelen representarse con letras minúsculas. (Montgomery 2004).
(44)
69
El efecto principal de "B" se obtiene mediante la siguiente ecuación:
(Montgomery 2004).
(45)
(46)
Dónde:
(1), a, b y ab: Total de las "n" réplicas.
n: Número de réplicas.
Se han usado contrastes para estimar "A", "B" y "AB"; la suma de cuadrados
del contraste puede calcularse mediante las siguientes ecuaciones:
(Montgomery 2004).
(47)
(48)
70
(49)
(50)
En general "SST" tiene "4n – 1" grados de libertad. La suma de cuadrados del
error con "4(n-1)" grados de libertad, suele calcularse mediante la siguiente
ecuación: (Montgomery 2004).
(51)
Luego de ello se puede construir la tabla ANOVA y obtener los estimadores "p".
(Montgomery 2004).
71
Figura 28: Coeficientes de los contrastes para estimar los efectos
Para un diseño factorial "2k", el modelo completo contiene "2k – 1" efectos.
(Montgomery 2004). El enfoque general para el análisis estadístico del diseño
"2k" se resume en la tabla 13:
72
Tabla 13: Procedimiento de análisis para un diseño "2k"
1. Estimar los efectos de los factores Información preliminar respecto a los
factores e interacciones que pueden
ser importantes y en que direcciones
debería ajustarse estos factores para
mejorar la respuesta.
2. Formar el modelo inicial Se elige el modelo completo, es decir
todos los factores e interacciones.
3. Realizar las pruebas estadísticas ANOVA para probar la significación
de los efectos principales y las
interacciones.
4. Refinar el modelo Eliminación de las variables no
significativas del modelo completo.
5. Analizar los residuales Verificar la adecuación del modelo y
los supuestos.
6. Interpretar los resultados Analizar gráficas de los efectos
principales o interacciones, gráfico de
probabilidad normal de los efectos y
gráfico de cubo.
Fuente: Elaboración propia en base a los aportes de Montgomery, 2004
(52)
73
Figura 30: ANOVA para un diseño factorial "2k" con "n" replicas
Una vez que se han calculado los contrastes de los efectos, pueden estimarse
los efectos y calcular la suma de cuadrados mediante las siguientes
ecuaciones: (Montgomery 2004).
(53)
(54)
74
Figura 31: Gráfica normal de efectos estandarizados
"Un efecto principal es una medida del cambio medio en la salida cuando un
factor cambia de su nivel bajo a su nivel alto". (Calderón 2009).
75
Figura 32: Diagrama de efectos principales
Las gráficas de cubo se utilizan para mostrar las relaciones entre dos a ocho
factores para los diseños factoriales de dos niveles. (MINITAB 2016).
76
el MINITAB 17 para facilitar los cálculos y dar mayor énfasis a la interpretación de los
resultados.
2.3.2 Adiciones
77
2.3.3 Puzolana
78
En el proceso por vía semi seca, "la materia se peletiza en pequeños nódulos
con una adición de agua del 10 al 15%". (UPME y Colciencias s.f.).
El proceso de producción por vía seca típicamente presenta siete etapas, las
cuales se describen a continuación.
2.3.5.2 Triturado
79
Trituradoras de rodillos.
Trituradoras de mandíbulas.
Trituradoras de cono.
Trituradores giratorios.
Trituradores de martillos.
Trituradores por choque.
Trituradores por choque combinados.
80
2.3.5.4 Molienda de crudos y homogenización
81
La harina pasa a través de los ciclones, donde se calienta por acción de
los gases generados en el quemador del horno rotatorio por combustión
de carbón, petróleo, gas, o algún combustible alternativo, iniciándose de
esta manera el proceso de descarbonatación y transformación termo –
químico del crudo.
82
2.3.5.6 Molienda de cemento
83
Los pitones de una tolva rotativa, que gira continuamente, llenan las
bolsas con el peso de 42.5 kilogramos descargándolas sobre una faja
transportadora.
84
Estos componentes raramente se encuentran en las proporciones deseadas, en
una sola sustancia". (Duda 1977).
En la tabla 14, se observan las características químicas que deben tener las
materias primas para poder ingresar al proceso de molienda de crudo.
85
Tabla 15: Parámetros de calidad del proceso productivo
Proceso Parámetro Significado Definición Rango
Molienda de crudo LSF Factor de saturación Capacidad de los compuestos del crudo 100 +/- 1%
de la cal para formar los minerales del clinker sin
tener presencia de cal libre
MS Módulo de sílice Factor que influye en la quemabilidad 2.2 – 2.8%
del clinker
MF Módulo de alúmina Factor que influye en la viscosidad de la 1.2 – 2.5%
fase líquida
Fineza Residuo que resulta de tamizar en una malla N° 170 10 – 14%
Producción de clinker C3S Silicato tricálsico Aporta resistencias al cemento 63%
C2S Silicato bicálsico Aporta resistencias a largo plazo al 15%
cemento
C3A Aluminato tricálsico Aporta resistencias iniciales al cemento 8%
C4AF Ferro aluminato Da la coloración del cemento 10%
tetracálsico
Cal libre Óxido de calcio Óxido de calcio que no reacciona en el 1%
horno
FL Fase líquida Medio por el cual se forman los silicatos 20 – 30%
del clinker
Molienda de carbón Fineza Residuo que resulta de tamizar en una malla N° 170 10 – 16%
86
Molienda de cemento Blaine Superficie específica Superficie de un gramo de gránulos 4000 – 5000
cuya superficie se hubiera extendido cm2/g
teóricamente
Fineza Residuo que resulta de tamizar en una malla N° 325 1%
3 días Resistencia mínima a la compresión del 13 Mpa
Resistencia 7 días cemento 1P 20 Mpa
28 días 25 Mpa
Fuente: Elaboración propia, Herrera, 2012, NTP 334.090, 2013 y Duda, 1977
87
2.3.7 Molinos verticales de rodillos
"Máquina con pista de molienda circular. Sobre ella se mueven los cuerpos
moledores (rodillos o bolas). Los cuerpos moledores presionan por su propio
peso, por fuerza centrífuga, por resortes o por sistemas hidráulicos o neumáticos
a la pista de molienda. Se pueden accionar tanto las pistas como los cuerpos
moledores".
"Los molinos de rodillos suelen ser molinos de barrido por aire y normalmente
tienen en su interior separadores de aire, por tanto, son utilizados para moler
muy fino en circuito cerrado secando simultáneamente el material (molinos
secaderos)". (Blanco s.f.).
Entre los materiales que se pueden moler con este tipo de molinos pueden
citarse los siguientes: (Blanco s.f.).
Caliza.
Cal calcinada.
Talco.
Bauxita.
Magnesita.
Fosfatos.
Baritas.
Carbón.
Grafito.
88
2.3.8 Principio de funcionamiento de los molinos verticales de rodillos
"El principio de trabajo de este tipo de molinos se basa en unos rodillos (o bien
otros cuerpos moledores comparables) que se mueven en una trayectoria
circular y girando alrededor de su eje, sobre un lecho de material de
alimentación situado sobre una placa, pista o bandeja de molienda horizontal
giratoria". (Blanco s.f.).
89
Figura 36: Molino vertical de rodillos
90
Figura 38: Sistema hidroneumático
"El material que llega al molino desde la dosificación cae a través de una
resbaladera sobre la pista, que se asienta sobre el plato y este, a su vez, sobre
el reductor girando con él". (Blanco s.f.).
"La alimentación del material a moler cae centralmente sobre el plato. Debido al
rozamiento, el material gira más o menos juntamente con el plato, con lo que se
ve sometido a la acción de la fuerza centrífuga, lo que hace que se mueva hacia
afuera en dirección a la pista de molienda". (Blanco s.f.).
"Al pasar el material entre los rodillos y la pista se produce la molienda por un
doble efecto de presión y rozamiento". (Blanco s.f.).
Los trozos mayores de material, sobresaliendo sobre los demás, son los
primeros en ser desmenuzados, por una combinación de esfuerzos de
compresión y corte. Se concentra encima de ellos la presión ejercida por el
rodillo, que excede por mucho su resistencia a la rotura. (Blanco s.f.).
91
"Luego los cuerpos moledores van actuando sobre las partículas que siguen en
tamaño y así sucesivamente. Este proceso continúa hasta que el material
alcanza la parte más estrecha de la separación entre el elemento moledor y la
pista de molienda". (Blanco s.f.).
"El material pulverizado, luego de pasar por debajo de los rodillos, por efecto de
la fuerza centrífuga es lanzado hacia la periferia de la pista de molienda por
donde se derrama". (Blanco s.f.).
92
Las partículas gruesas, que no son capaces de ser arrastradas por la corriente
de gas, caen a través del anillo de toberas a un anillo de descarga, que gira con
el plato de molienda y llega por una resbaladera de evacuación lateral a un
medio de transporte, que lo devuelve al molino con o sin separación intermedia.
(Blanco s.f.).
"La velocidad del gas en el anillo de toberas se ajusta de manera que no todo el
material que cae del plato sea arrastrado por la corriente de gas al separador.
Este es el efecto de clasificación preliminar, que se distingue de la separación
final que se cumple en el clasificador situado en lo alto de la caja del molino".
(Blanco s.f.).
93
rechazan las partículas gruesas, eso dependerá de la velocidad del flujo de
gases y de la masa de las partículas. (Blanco s.f.).
Seguidamente las partículas finas ingresan a los álabes del rotor donde se
produce la última clasificación, allí las partículas medianas son más lentas que
las partículas pequeñas y toman más tiempo para pasar los álabes del rotor que
está girando a una velocidad determinada, por lo tanto, las partículas medianas
serán expulsadas por el golpe directo con los álabes. (Blanco s.f.).
94
Figura 42: Proceso típico de un molino vertical
95
2.3.9 Clasificación de los molinos verticales
"En esencia, este molino consta del recinto de molienda, separador por
aire y reductor del accionamiento. En el recinto de molienda gira el anillo
de molienda inferior, mientras que el superior es estacionario". (Blanco
s.f.).
96
"El material de alimentación húmedo puede secarse intensivamente
dentro del molino por medio de aire o gases inertes a alta temperatura.
Según los datos de los fabricantes del molino es posible utilizar gases
con temperaturas, a la entrada del molino, de 600 °C". (Blanco s.f.).
97
"La presión de los rodillos se hace mediante un bastidor de presión,
indirectamente por medio de unidades de presión que se encuentran
móviles debajo del bastidor. De este modo se evitan los puntos críticos
de desgaste". (Blanco s.f.).
98
Figura 44: Molino vertical PFEIFFER
99
molienda. En el arranque el molino trabaja con menos carga al reducir la
presión de trabajo en el sistema hidráulico. (Blanco s.f.).
"El rodillo interior, o sea, el que se encuentra más cerca del centro del
molino, se mueve mucho más lento que el rodillo exterior. Por tanto, el
rodillo interior se desgasta menos que el exterior. La velocidad relativa
de ambos rodillos en comparación a la pista es muy poca". (Blanco s.f.).
"El material que éste ha separado cae por el centro sobre el disco
rotatorio de molienda, mientras que los finos quedan depositados en un
filtro electrostático dispuesto a continuación". (Blanco s.f.).
100
Figura 45: Molino vertical POLYSIUS
101
"La unidad de tres rodillos está fijada en el cubículo de la molienda. Los
rodillos giran sobre su propio eje, pero no alrededor del centro del plato".
(Blanco s.f.).
102
Figura 46: Molino vertical ATOX
"Al rozar los rodillos de molienda con el lecho sobre el plato, balancines
y vástagos del sistema se elevan por acción de los cilindros hidráulicos.
El aceite de los depósitos hidráulicos de la parte superior es eliminado
en el acumulador hidráulico lleno de gas". (Blanco s.f.).
103
"El material molido se transporta mediante las fuerzas centrífugas a la
parte superior de la corona de álabes, que rodea el plato, donde es
recogido por la corriente de gas caliente para ser transportado hasta el
separador". (Blanco s.f.).
104
que es posible por el control de rodillos individual en balancines".
(Blanco s.f.).
LM XX Y + Z
Dónde:
105
Figura 47: Molino vertical LOESCHE
106
Figura 48: Equipos auxiliares de un molino vertical
"La cinta transportadora va montada en forma de correa sin fin sobre dos
tambores de cambio de dirección situados en los extremos; uno de ellos
es motor y produce el accionamiento y el otro sirve únicamente como
tensor". (Labahn 1966).
107
"El ramal superior de la cinta puede ser guiado en forma plana o en
forma cóncava; el inferior o de retorno es conducido en forma plana".
(Labahn 1966).
"El vertido del material puede hacerse por encima del rodillo terminal o
en el punto que se desee por medio de deflectores u otro sistema".
(Labahn 1966).
108
"Los cangilones van fijos en las cadenas sin fin, conducidas por dos
tambores, uno superior motor y otro inferior tensor". (Labahn 1966).
"El tambor inferior rueda en una tolva, de la cual los cangilones recogen
el material a elevar. Estos últimos elevan el material y lo vuelcan al
invertir su posición cuando pasan por encima del tambor superior,
vertiéndolo en una tolva o canal". (Labahn 1966).
109
2.3.10.3 Canaletas aerodeslizantes
110
2.3.10.4 Balanzas dosificadoras
111
para luego ser descargado por el chute de salida. (Nagulmeera y
Anilkumar 2013).
112
Continuando su ascenso, el aire se topa y rodea a las bolsas tubulares
apoyadas internamente mediante jaulas de alambre, pasa a través de
las bolsas y se eleva en el interior de estas hasta un compartimento de
aire limpio común del que es descargado. (Bhatty et al. 2004).
Este filtro es por lo general de una sola cámara, salvo en los sistemas de
producción continua en donde se contempla divisiones completas dentro
de los filtros; esto para tener la posibilidad de realizar mantenimiento a
los mismos. (Bhatty et al. 2004).
La limpieza de las mangas se realizan fila por fila. Para ello existe un
tubo (flauta) que posee pequeños agujeros, de número igual al de
mangas filtrantes ubicados en fila y ubicados en el medio de estas.
(Bhatty et al. 2004).
113
Para mangas filtrantes normales, se recomienda que la presión
diferencial llegue de 3” a 6” de agua; en el caso de mangas tipo
membrana (de papel) la presión deberá ser de 2” a 4” de agua. (Bhatty
et al. 2004).
114
CAPÍTULO III
115
DIAGNÓSTICO SITUACIONAL DEL MOLINO LM 56 2 + 2 CS
En este capítulo primeramente se van a describir los sistemas propios del molino caso
de estudio y luego se van a desarrollar los indicadores de producción mencionados en el
capítulo I para poder saber cuánto falta por mejorar.
El material antes de ingresar al molino pasa por una válvula rotativa que dosifica la
caída del material y evita el desgaste excesivo de los componentes de la cámara
interior del molino.
El aditivo de molienda es inyectado por una bomba mientras el material pasa por la
válvula rotativa.
El material ingresa a la mesa de molienda accionada por el motor – reductor, y por las
fuerzas centrífugas de ésta, el material es esparcido hacia el dam ring, el cual forma
la cama de material, mientras tanto los rodillos esclavos comprimen el material y los
rodillos máster muelen el material comprimido.
Simultáneamente, una bomba centrífuga inyecta agua debajo de las llantas de los
rodillos máster para facilitar la molienda y evitar vibraciones del molino.
El flujo de gases generado por el ventilador principal ingresa por el nozzle ring y
transporta el material molido por los rodillos máster hacia el clasificador dinámico.
116
El flujo de gases a la salida del molino debe tener una temperatura de 80+/- 5 ° C
para secar el material, la temperatura se obtiene por medio de dos ductos que
provienen del enfriador del horno de la planta de cemento, los cuales llegan en
valores de 90 a 130 ° C.
Ocasionalmente, cuando el horno está parado, se usan gases calientes que provienen
de un generador de gases.
En el clasificador dinámico, el material golpea contra los álabes fijos y luego contra los
álabes móviles del rotor, una vez pasados los álabes móviles, el material ya
clasificado es transportado por el flujo de gas hacia el filtro de mangas principal.
El cemento se adhiere a las mangas del filtro, mientras que válvulas solenoides
disparan aire comprimido y las sacuden fuertemente, provocando que el cemento
caiga hacia un conjunto de aerodeslizadores y elevadores de cangilones para ser
transportado hacia los silos de almacenamiento de producto terminado.
117
Figura 55: Diagrama de flujo del proceso del molino Loesche 56 2+2 CS
Los equipos de un molino vertical se clasifican en principales, los cuales son los
equipos que pertenecen al molino, y en auxiliares, los cuales son los equipos de
transporte y despolvorización de material usados en la industria minera y cementera
en general.
Los equipos principales son el motor, reductor, la cámara de rechazo, los rodillos, la
mesa de molienda, los sistemas de lubricación e hidráulicos y el clasificador dinámico.
3.2.1 Motor
118
a tres anillos metálicos por uno de sus extremos, en tanto que, por el otro lado
se conectan en estrella. (MENZEL 2005).
Marca: MENZEL.
Tipo: MEBSSL710K-06-067.
Diseño: IEC 34-1 / EN 60034-1.
Potencia nominal: 4000 KW.
Servicio: S1.
Voltaje del estator: 6000 +/- 5%.
Corriente del estator: 443.
Conexión: Y.
Voltaje del rotor: 1655 +/- 5%.
Corriente del rotor: 1475 +/- 5%.
Frecuencia: 60 +/- 2%.
Velocidad (rpm): 1192.
Polos: 6.
Dirección de rotación: Antihorario.
Eficiencia: 96.5%.
Factor de potencia: 0.9.
Torque nominal (Nm): 32060.
3.2.2 Reductor
"El piñón de ataque flotante del primer planetario está conectado al eje del
engranaje cónico por medio de un acople doble coronado. El torque es
transmitido en el engranaje central interior del segundo planetario". (RENK
2000).
119
"El acoplamiento del eje está conectado rígidamente en su parte baja con la
porta planetario. La porta planetarios está fijado verticalmente. El toque es
introducido en el piñón del segundo planetario en seis engranajes planetarios".
(RENK 2000).
"Para absorber la presión axial del molino, así como el peso del material a moler
y la mesa un rodamiento axial especial está dispuesto en la parte superior del
lado de salida de la cubierta". (RENK 2000).
120
Identificación RENK: 80103995.
Año de fabricación: 2000.
Potencia nominal: 4000 KW.
Velocidad de entrada: 1190 rpm.
Velocidad de salida: 22 rpm.
Ratio: 53.9.
Carga en rodamiento axial: 6550 KN.
Aceite: 4100 litros de aceite ISO VG 320.
Motor auxiliar: SEW K77DT90L4-TF con variador de frecuencia, potencia
1.5 KW.
Los gases que ingresan hacia la cámara de molienda sirven para transportar el
material molido hacia el filtro principal y luego retornar hacia el molino en un ciclo
cerrado.
Cuando los rascadores giran, empujan el material grueso hacia una tolva
temporal, luego por medio de una faja transportadora y un elevador de
cangilones este ingresa nuevamente al proceso.
121
Figura 57: Cámara de rechazo
Los rodillos máster son los equipos que muelen el material fresco que está
sobre la mesa, sus componentes estructurales se muestran en la figura 58.
Se inyecta aire de sello a través del rocker arm dentro del rodillo para prevenir la
penetración del polvo.
122
Las llantas del rodillo están hechas de una alta aleación de cromo, resistentes al
desgaste, pero frágiles. (Mischorr 2010).
Para evitar el daño de los rodillos, éstos no deben rebotar muy fuerte durante la
operación y se debe evitar el contacto con partículas metálicas y/o ferrosas que
ingresen con el material de alimentación. (Mischorr 2010).
Para evitar que los rodillos golpeen la mesa de molienda, hay un tope mecánico
que los mantiene a 20 mm de esta.
Los rodillos esclavos compactan el material y lo prepara para ser molido por
los rodillos máster.
Se aplica presión hidráulica para bajar los rodillos hacia la mesa y para mantener
la posición de trabajo que es de 70 a 100 mm sobre ésta. (Mischorr 2010).
123
3.2.6 Mesa de molienda
El material de sobra pasará por encima del dam ring hacia los segmentos nozzle
ring, el material fino se irá hacia arriba del molino transportado por el flujo de
gases y el material grueso caerá por los segmentos hacia la cámara de rechazo.
(Mischorr 2010).
124
3.2.8 Nozzle ring (Louvre ring)
Actúa como una boquilla para generar un puente aéreo, es importante que el
flujo de gases que circula por ese sector sea el adecuado para evitar el excesivo
rechazo de material, si es mucho ocasionara más desgaste en la cámara interior.
(Mischorr 2010).
Debajo de cada rodillo máster hay placas fijas del nozzle ring para evitar el
desgaste excesivo de sus ejes. (Mischorr 2010).
Las placas del nozzle ring están inclinadas 45° para guiar el flujo de gases hacia
la parte superior del molino. (Mischorr 2010).
Actúa como protección del cuerpo del molino, está inclinado hacia adentro
en 30° para evitar que el material y el gas vayan hacia las paredes, mucha
inclinación hace que haya gran desgaste en el centro del molino. (Mischorr
2010).
El área hueca entre el armor ring y la pared del molino, sirve para que se llene
de material durante la operación y actúa como una protección natural para el
desgaste. (Mischorr 2010).
125
Figura 60: Mesa de molienda, armor ring, dam ring y nozzle ring
Las bombas de agua de planta proveen a este sistema, luego existen dos
bombas centrifugas dispuestas en paralelo como forma de protección de la
operación.
La bomba suministra agua desde un tanque hacia dos toberas, las cuales están
ubicadas debajo de cada rodillo máster, estas toberas distribuyen el agua en el
lecho de molienda.
126
Figura 61: Plano del sistema de inyección de agua
127
Figura 62: Componentes del sistema hidráulico de los rodillos máster
Las funciones de este sistema son bajar los rodillos durante el arranque, elevar
los rodillos al cortar alimentación, proveer la presión hidráulica en la operación
de molienda y absorber el choque de los rodillos. (Mischorr 2010).
Las bombas hidráulicas bombean aceite del tanque a través de las líneas hacia
los cilindros, las válvulas dirigen el aceite hacia el lugar adecuado y la presión es
ajustada. (Mischorr 2010).
128
La presión de operación jala el rocker arm hacia abajo presionando el rodillo
hacia el material, mientras que la contrapresión absorbe el choque adicional para
una operación suave del molino. (Mischorr 2010).
Cuando el molino está en trabajo, los rodillos saltan hacia arriba y hacia abajo, lo
cual resulta en un continuo intercambio de aceite entre los cilindros y los
acumuladores en ambos lados (absorbe el choque). (Mischorr 2010).
Los componentes del sistema de lubricación por rodillo máster son los
siguientes: (Mischorr 2010).
129
1 bomba de presión para transmitir el aceite precalentado dentro del
rodillo pasando por:
1 filtro de aceite con una válvula baipás.
1 enfriador de aceite con una válvula de control de agua.
Medidores de presión local indicando la presión en la línea antes y
después del enfriador de aceite.
1 válvula de seguridad reguladora de presión antes del enfriador atrás del
tanque.
1 bomba de succión que retorna el aceite del rodillo hacia el tanque
pasando por:
1filtro de aceite.
1 medidor local de presión indicando la succión antes del filtro.
130
Datos técnicos: (Mischorr 2010).
Si el aceite es muy frío la bomba de presión bombea más aceite que lo que
succiona la bomba de succión y el rodillo se llena mucho, si el aceite es muy
caliente los sellos internos se pueden dañar. (Mischorr 2010).
Las bombas de succión arrancan varios minutos antes que las bombas de
presión.
131
3.2.13 Sistema de engrase del rocker arm de los rodillos máster
Las conexiones del rocker arm hacia los cilindros hidráulicos son engrasadas
manualmente, existen 4 puntos de grasa por rodillo. (Mischorr 2010).
Las conexiones entre los cilindros hidráulicos y la base del molino son
engrasadas manualmente, son 2 puntos de grasa por rodillo. (Mischorr 2010).
Figura 65: Puntos de engrase del rocker arm de los rodillos máster
132
3.2.14 Sistema hidráulico de los rodillos esclavos
Los componentes del sistema hidráulico son los siguientes: (Mischorr 2010).
133
Figura 66: Componentes del sistema hidráulico de rodillos esclavos
134
Figura 67: Sistemas de lubricación del reductor RENK
135
Figura 68: Sistema de baja presión del reductor RENK
La bomba succiona el aceite del reductor, el cual pasa por el filtro dual de 40
micrones cada uno, la ventaja de contar con esos dos filtros en paralelo es que
si uno se satura se puede direccionar la línea hacia el otro.
Cuando se filtra el aceite, éste pasa por un enfriador de tubos el cual cuenta con
una válvula mecánica de tres vías que retorna a la línea el aceite aún caliente.
Parte del aceite de este sistema es bombeado hacia la parte superior del
reductor donde se encuentran los PADS, este aceite tiene la finalidad de enfriar
esa zona para evitar que los PADS calienten ya que son muy sensibles ante la
temperatura y podrían dañarse.
136
16 bombas de alta presión de pistones de 7.61 litros/min de capacidad, de
46 BAR y 50 º C.
4 motores Siemens 18 KW de potencia y 1200 rpm.
16 presostatos de 5 BAR de presión máxima.
16 válvulas de seguridad de 170 BAR de presión máxima.
3 sensores de presión uno de 0.96 BAR de presión máxima y los otros 2
de 0.7 Bar.
1 termocupla, a 70 º C es la máxima temperatura de operación.
16 líneas de alta presión.
16 PADS cada uno con una válvula antirretorno.
Líneas de evacuación de aceite de la parte superior hacia la parte inferior
del reductor.
Respiradero.
Visores de nivel de aceite.
Válvula manual en la parte inferior del reductor para operación de drenaje.
4 termocuplas en la zona de los PADS con un rango máximo de
temperatura de operación de 75 º C.
137
Figura 70: Sistema de alta presión del reductor RENK parte 2
Este sistema cuenta con 4 motores que accionan 16 bombas, una para cada
PAD, y así se inyecta el aceite hacia la parte superior mediante líneas
independientes.
138
1 bomba de engranajes de 81 litros / min de capacidad, de 4 BAR y 61 º
C.
1 motor Siemens de 2.55 KW de potencia y 1200 rpm.
Válvula de seguridad con 7 BAR de presión máxima.
Válvula antirretorno.
2 válvulas de bola manuales.
1 filtro de aceite de 16 micras con 6 BAR de presión máxima.
Este circuito filtra finamente el aceite y luego lo retorna a los sistemas de baja y
alta presión, su función secundaria es usar la bomba para introducir o drenar
aceite del reductor en un cambio de aceite por mantenimiento.
139
El agua del tanque diario es bombeada hacia el sistema de lubricación del
reductor como se observa en la figura 72.
Componentes estructurales:
140
30 álabes fijos.
Cono de gruesos.
Ducto de salida.
1 bomba de pistones de grasa KPF 2 G.
141
Después de dejar el espacio entre los álabes fijos y el rotor, las partículas
gruesas vuelven a la mesa de molienda para ser molidas nuevamente y el
material ya clasificado sale del clasificador con el flujo de gases hacia el filtro del
sistema. (Mischorr 2010).
El molino vertical produce varios tipos de cemento portland, entre ellos el cemento
tipo 1P y el cemento tipo HE.
142
Tabla 16: Producción de cemento en el mes 1
020%
1P
HE
080%
143
Tabla 17: Producción de cemento en el mes 2
013%
1P
HE
087%
144
Tabla 18: Producción de cemento en el mes 3
030%
1P
070% HE
145
Tabla 19: Producción de cemento en el mes 4
021%
1P
079% HE
146
Con estas observaciones se demuestra que si existe un decremento de la
productividad cuando se producen cementos portland tipo HE.
Una vez demostrado que hay un decremento en la productividad del molino cuando
se producen cementos portland tipo HE, se van a incluir los indicadores relevantes
definidos en el capítulo I, los cuales son las toneladas por hora producidas (TM/h), el
consumo de energía (KW-h/TM) y el consumo de aditivo de molienda (gr/TM).
En la tabla 21 se presenta una muestra de un día 1 del mes 5, la cual contiene los
parámetros del proceso de molienda de cemento portland puzolánico tipo 1P.
La leyenda utilizada para leer las tablas 21, 22, 23,24 y 25 es la que se presenta en la
tabla 20:
147
Tabla 21: Parámetros operacionales para el cemento portland 1P día 1
Se tomaron cuatro días de muestra de producción de cementos portland tipo HE durante el mes 5, como en el caso
anterior, se va a establecer los indicadores para poder determinar las diferencias con la producción de cemento portland
puzolánico tipo 1P.
152
Tabla 22: Parámetros operacionales para el cemento portland HE día 2
156
Toneladas producidas: 159,36 TM/h. (Ver tabla 22).
Consumo de energía: 34,74 KW-h/TM. (Ver anexo 10).
Consumo de aditivo: 370,13 gr/TM. (Ver anexo 10).
157
03:10 3763,06 440,92 102,4 82,01 154,34 34,93 101,48 686,67 500202,6 102,57 1699,91 2,68 -4,5
03:20 3795,11 434,64 102,34 81,93 150,06 34,57 101,47 684,88 500993,3 102,55 1700,23 2,74 -4,2
03:30 3759,93 432,74 102,28 81,98 150,08 34,57 101,48 684,28 499413,3 102,58 1698,81 2,69 -4,04
03:40 3662 437,19 102,29 81,79 150,64 34,94 101,49 686,17 499176,2 102,58 1701,43 2,64 -5
03:50 3680,03 446,26 102,37 82,12 153,01 35,69 101,48 690,3 499441 102,56 1698,25 2,64 -4,68
04:00 3628,34 446,06 102,42 82 152,99 35,41 101,45 689,03 499599,9 102,6 1700,66 2,6 -5,53
04:10 3670,79 447,77 102,48 82 154,46 35,6 101,44 690,47 500077,3 102,56 1700,55 2,61 -5,23
04:20 3651,9 449,48 102,5 82,12 163,88 35,55 101,42 690,28 499626,3 102,57 1699,88 2,6 -5,43
04:30 3652,33 450,22 102,52 82,02 169,99 35,66 101,38 691,33 499619,3 102,58 1699,91 2,6 -5,47
04:40 3662,13 449,99 102,46 81,92 170,04 35,64 101,43 691,45 500783,8 102,61 1699,88 2,59 -4,92
04:50 3612,75 450,06 102,46 82,07 169,97 35,51 101,42 689,9 499003,2 102,6 1699,75 2,59 -5,77
05:00 3625,84 453,57 102,4 81,93 169,95 35,81 101,33 692,53 500532,4 102,62 1699,51 2,58 -5,36
05:10 3676,42 454,48 102,55 82,05 169,99 35,82 101,25 691,9 499795,8 102,58 1699,46 2,63 -4,64
05:20 3673,49 448,27 102,66 81,98 169,81 35,21 101,48 688,8 501154,5 102,57 1700,76 2,67 -5,01
05:30 3711,16 447,71 102,63 82 166,72 35,09 101,45 687,97 500456,3 102,58 1699,27 2,69 -4,33
05:40 3668,8 453,1 102,37 82,03 162,92 35,7 101,42 690,62 498368,4 102,57 1699,8 2,64 -5,14
05:50 3609,68 449,98 102,38 81,96 162,95 35,57 101,44 690,38 500317,7 102,54 1701,48 2,63 -5,58
06:00 3661,6 453,68 102,46 82,1 162,95 35,9 101,38 692,65 500228,5 102,59 1699,27 2,63 -4,74
06:10 3624,14 450,55 102,4 82,01 163,02 35,52 101,4 690,28 499791,2 102,58 1700,82 2,63 -5,6
06:20 3646,68 453,49 102,39 81,96 162,98 35,88 101,37 692,12 499727,4 102,55 1699,91 2,62 -5,16
06:30 3612,05 451,22 102,32 81,84 163,01 35,71 101,41 691,35 500876,6 102,58 1699,48 2,6 -5,19
06:40 3625,15 451,82 102,33 82,17 163 35,73 101,38 690,97 499784,4 102,59 1699,27 2,6 -4,94
06:50 3603,59 450,2 102,37 81,92 163,5 35,5 101,45 690,1 499959,3 102,57 1701,91 2,61 -5,49
07:00 3627,69 449,83 102,35 81,94 163,97 35,58 101,41 691,08 500278,3 102,57 1699,32 2,65 -5,1
07:10 3660,56 451,92 102,41 82,14 163,99 35,67 101,39 690,58 499330,3 102,56 1699,56 2,65 -4,66
07:20 3696,29 450,42 102,58 82,07 163,99 35,16 101,44 689,05 500626 102,57 1700,15 2,69 -4,8
07:30 3800,83 454,23 102,67 82,05 164,07 35,27 101,33 689,9 499386,7 102,55 1699,96 2,75 -2,8
07:40 3854,8 456,28 102,64 81,94 162,49 35,65 101,02 692,3 499266,4 102,57 1700,39 2,71 -2,65
07:50 3830,73 457,23 102,5 81,99 162 36,32 100,54 695,75 499085,3 102,55 1699,88 2,64 -4,25
08:00 3830,92 457,29 102,51 82,02 161,97 36,79 100,13 699 499668,4 102,58 1699,46 2,62 -3,77
08:10 3809,19 457,27 102,6 82,01 161,92 36,77 100,25 698,7 500103,1 102,56 1700,02 2,63 -4,12
08:20 3776,18 457,32 102,67 82 162 36,48 100,36 697,42 500688,3 102,58 1699,67 2,62 -4,35
08:30 3715,35 457,23 102,66 81,97 163,09 36,19 100,79 694,85 500098,8 102,59 1700,95 2,62 -5,36
08:40 3693,74 457,19 102,68 81,97 165,98 36,07 100,79 694,7 500498,8 102,6 1698,52 2,62 -5,63
158
08:50 3589,19 449,29 102,9 81,97 165,95 35,4 101,32 690,58 501653,1 102,56 1700,15 2,58 -6,2
09:00 3551,91 438,93 103,32 82,04 165,95 34,6 101,49 685,4 500719 102,58 1700,6 2,58 -6,42
09:10 3574,86 434,97 103,62 81,98 157,34 34,44 101,5 684,7 500057,5 102,54 1699,38 2,62 -6,13
09:20 3744,74 445,98 103,65 82,3 147,07 34,87 101,46 687,5 498341,8 102,58 1700,52 2,67 -4,56
09:30 3816,24 447,37 101,95 81,97 150,69 35,05 101,46 690,85 502843,2 102,59 1617,56 2,68 -4,61
09:40 3785,75 453,71 99,22 81,13 162,11 35,77 101,13 695,58 505767,2 102,57 1418,4 2,9 -3,33
Promedio 3698,68 446,90 102,42 81,99 161,03 35,40 101,33 689,91 500127,97 102,57 1693,81 2,64 -5,01
Fuente: La empresa
159
01:30 3681,29 415,26 103,06 80,71 167,72 33,8 99,52 672,08 491783,7 100 1399,82 2,68 -3,17
01:40 3675,31 407,3 103,25 80,96 170,49 33,08 99,52 667,3 490769,1 100 1400,38 2,69 -3,48
01:50 3677,39 401,75 103,14 80,95 169,21 32,76 99,53 665,05 490395,2 99,98 1398,78 2,71 -3,38
02:00 3666,07 399,32 103 80,97 168,2 32,5 99,5 663,8 490333,6 99,98 1401,15 2,71 -3,38
02:10 3656,06 401,7 103,27 81 168,98 32,58 99,52 664,33 489859,6 100,01 1398,56 2,7 -3,45
02:20 3630,25 401,88 103,06 81,02 170,17 32,63 99,53 664,42 489777,3 100,01 1400,01 2,69 -3,51
02:30 3693,77 409,81 103,21 81,03 174,26 33,02 99,52 667,2 489050,9 100,01 1401,31 2,72 -3,17
02:40 3707,66 414,93 103,28 81,04 174,2 33,48 99,52 670 489645,3 99,99 1399,04 2,68 -3,03
02:50 3715,4 414,88 103,33 81,03 169,6 33,44 99,52 670,03 490023,1 100 1400,7 2,71 -2,72
03:00 3714,07 411,49 103,41 81,04 164,51 33,3 99,5 669 490184,1 100 1399,36 2,73 -2
03:10 3735,42 412,96 103,26 80,89 167,81 33,44 99,53 669,47 489573,9 100 1401,29 2,72 -2,25
03:20 3690,02 412,69 103,26 80,99 170,85 33,41 99,5 669,55 490023,3 100,01 1399,69 2,7 -2,97
03:30 3693,65 416,13 103,26 81,03 173,23 33,52 99,53 670,5 489755,6 100,01 1400,09 2,7 -2,89
03:40 3689,73 416,77 103,26 81,04 173,21 33,64 99,5 671,22 489812,5 100,02 1399,2 2,74 -2,75
03:50 3711,84 414,87 103,41 81,05 168,61 33,49 99,54 670,42 490409,9 100,02 1399,85 2,72 -2,42
04:00 3590,52 413,92 103,3 80,68 162,64 33,79 99,5 671,1 489010,1 100 1400,99 2,73 3,16
04:10 3706,01 413,29 103,38 81,22 164,27 33,79 99,52 672,35 490522,8 99,98 1399,23 2,7 -1,35
04:20 3693,57 414,31 103,26 81,03 173,9 33,85 99,52 672,25 489605,7 100 1400,91 2,7 -2,66
04:30 3694,15 415,29 103,33 81,01 174,02 33,92 99,52 673,28 490133,6 100,02 1399,2 2,69 -2,68
04:40 3666,69 413,65 103,43 81,02 170,64 33,72 99,5 671,88 490339,5 100,02 1400,65 2,71 -2,51
04:50 3673,74 413,95 103,38 80,96 171,07 33,8 99,53 672,35 489864,2 99,98 1399,71 2,76 -1,96
05:00 3677,07 414,9 103,43 81,11 171,74 33,7 99,51 671,8 490283,4 99,99 1399,18 2,72 -2,03
05:10 3727,88 408,18 103,62 81,02 159,41 33,39 99,52 670,17 490225,4 100,01 1401,58 2,74 -0,45
05:20 3702,12 409,2 103,63 81,1 163,26 33,46 99,54 670,4 489725,2 99,99 1400,14 2,73 -0,38
05:30 3752,13 408,16 103,63 81,06 161,04 33,49 99,53 671,5 489891,3 99,99 1399,55 2,74 -0,5
05:40 3707,44 416,49 103,49 81,03 164,12 33,86 99,51 673,7 489372,2 100,01 1399,07 2,68 -0,85
05:50 3712,44 419,55 103,5 81,16 167,2 34,2 99,51 675,88 489324 100,01 1400,73 2,68 -1,9
06:00 3714,65 428,55 103,4 80,94 173,08 34,59 99,52 678,65 489396,7 100 1399,77 2,69 -2,84
06:10 3716,27 432,99 103,42 81,05 175,98 34,82 99,52 680,3 489560,7 99,99 1399,66 2,64 -3,2
06:20 3722,52 433,35 103,44 81,01 173,79 34,87 99,5 680,75 489855,2 100,03 1400,17 2,65 -3,22
06:30 3720,41 434,89 103,41 80,96 171,21 34,98 99,49 681,2 490266,6 100,02 1400,43 2,66 -2,27
06:40 3698,57 426,53 103,53 81,01 166,33 34,48 99,53 677,97 491024,1 99,99 1398,7 2,68 -1,83
06:50 3711,27 419,01 103,61 80,99 161,77 34,1 99,54 675,65 490188,8 100 1399,93 2,72 -1,63
07:00 3726,07 419,87 103,51 81,05 164,87 34,21 99,53 676,58 489352,5 100,02 1399,71 2,68 -1,97
160
07:10 3740,76 429,83 103,47 81,01 172,17 34,74 99,52 680,03 489184,3 100,01 1400,03 2,66 -2,19
07:20 3735,2 433,15 103,46 81,05 172,94 34,88 99,51 681,95 489914,5 99,99 1398,91 2,65 -2,45
07:30 3739,15 428,76 103,53 80,97 170,14 34,74 99,54 680,83 490627,9 99,99 1399,85 2,68 -1,99
07:40 3730,99 422,33 103,65 80,98 162,44 34,36 99,51 678,78 490381,5 99,99 1400,14 2,69 -1,19
07:50 3764,33 419,66 103,81 81,01 161,21 33,98 99,52 676,55 490391,6 100 1400,67 2,68 -1,5
08:00 3775,68 418,02 103,87 81,02 163,88 33,95 99,53 676,5 489761,4 100,03 1398,99 2,7 -1,7
08:10 3808,33 421,67 103,89 81,03 168,19 34,15 99,52 677,33 489859,1 100,01 1400,57 2,67 -2,12
08:20 3821,23 418,83 104,1 81,01 161,98 33,98 99,51 675,85 490587,8 99,96 1399,28 2,66 -0,47
08:30 3838,81 416,58 104,21 81,02 160,08 33,73 99,49 673,55 490217,9 99,99 1400,94 2,68 -1,17
08:40 3875,63 422,49 104,16 80,96 168,16 33,83 99,52 674,85 489951,6 99,98 1399,44 2,65 -2,64
08:50 3907,69 427,64 104,29 81,06 174,84 34,1 99,51 675,75 489625,8 100,04 1398,78 2,61 -3,81
09:00 3855,26 422,02 103,93 80,95 169,96 33,94 99,53 676,97 494313,4 99,98 1400,11 2,6 -4,26
09:10 3809,62 419,47 103,73 81,03 173,13 33,94 99,52 677,28 494872,7 100,04 1400,19 2,59 -4,12
09:20 3804,57 417,67 103,67 80,93 169,73 34 99,52 677,15 495325,8 99,98 1399,31 2,59 -3,56
09:30 3771,89 416,21 103,51 81,01 170,71 33,79 99,5 676,4 494667,3 100 1400,3 2,61 -3,9
09:40 3793,18 417,89 103,69 80,97 169,26 33,88 99,5 677,22 495256,4 100 1399,47 2,61 -3,3
09:50 3795,24 411,6 103,84 81,05 170,32 33,69 99,51 675,78 494767,1 100,02 1399,79 2,59 -3,52
10:00 3811,1 416,47 103,53 81,05 170,8 33,86 99,53 676,95 494822,3 99,98 1400,33 2,6 -3,49
10:10 3793,77 413,75 103,79 80,96 167,89 33,78 99,54 676,6 495370,8 100 1399,87 2,63 -3,44
10:20 3824,17 411,43 103,68 81,07 161,39 33,54 99,52 676,15 494932,1 100,01 1400,67 2,65 -2,86
10:30 3850,86 407,66 103,66 81 155,74 33,3 99,53 674,3 495717,8 100,01 1400,54 2,68 -2,87
10:40 3866,36 409,06 103,53 80,89 158,63 33,26 99,52 674,67 494742 99,99 1399,2 2,66 -2,53
10:50 3754,31 407,16 103,55 81,11 164,24 33,49 99,5 674,97 494343,3 99,98 1401,15 2,59 -3
11:00 3705,93 415,21 103,51 80,95 171,13 34,01 99,52 678,95 494242,2 100,02 1399,5 2,58 -3,17
11:10 3699,14 418,64 103,67 80,97 173,35 34,48 99,52 681,5 494418,3 100 1399,76 2,55 -3,58
11:20 3663,1 415,88 103,81 80,98 170,42 34,5 99,53 681,22 495447,3 100,01 1399,9 2,55 -3,09
11:30 3676,48 414,03 103,44 81,03 169,14 34,15 99,52 679,4 495990,9 99,98 1399,12 2,56 -3,48
11:40 3750,65 409,88 103,25 81,07 160,39 33,84 99,53 678,53 494429,8 99,99 1401,53 2,57 -1,29
11:50 3775,18 407,97 103,51 80,92 156,8 33,64 99,54 677,42 495589,5 100,02 1399,74 2,58 -0,8
12:00 3728,33 409,77 103,31 80,86 164,96 33,79 99,51 676,5 495233,8 100,02 1400,41 2,59 -2,43
12:10 3662,56 415,55 103,03 80,83 169,03 34,01 99,49 677,5 494311,3 100 1401,07 2,59 -2,56
12:20 3626,99 415,52 103,08 81,2 165,79 34,09 99,53 677,97 495330,7 100,01 1400,06 2,57 -2,84
12:30 3690,04 416,13 103,25 81,14 164,12 33,9 99,53 678,03 494753,9 99,99 1399,98 2,58 -2,39
12:40 3755 413,77 103,48 81,03 153,47 33,66 99,52 677,35 495726,4 99,99 1399,82 2,59 0,02
161
12:50 3765,33 411,05 102,96 80,92 151,49 33,39 99,5 676,4 495139,2 100 1400,49 2,67 0,36
13:00 3764,62 408,33 102,93 81,05 159,08 33,58 99,51 676,5 494829,7 99,99 1399,82 2,62 -0,93
13:10 3771,67 412,71 102,89 81,01 161,1 33,79 99,52 678,53 494375,8 100,02 1399,39 2,62 -1,04
13:20 3825,06 416,82 103 81,07 162,17 34,11 99,53 681,17 494188,3 100 1399,55 2,59 -1,57
13:30 3825,12 417,08 102,99 81,03 162,09 34,34 99,5 682,62 494697,4 99,99 1398,88 2,56 -1,7
13:40 3860,13 422,79 103,04 81,05 167,11 34,56 99,52 684,8 494494,8 99,98 1400,97 2,58 -1,91
13:50 3898,89 425,54 103,04 80,96 166,79 34,76 99,51 686 494946,9 99,97 1398,7 2,57 -2,61
14:00 3898,48 431,22 103,03 80,98 165,68 34,97 99,55 687,72 496911,1 100,07 1425,18 2,54 -3,7
14:10 3801,47 421,73 103 80,95 163,67 34,59 99,54 685,72 501238,3 100 1499,57 2,5 -4,16
14:20 3762,99 417,23 102,89 80,89 161,47 34,24 99,51 682,42 498527,6 100,02 1500,69 2,55 -2,97
14:30 3775,5 417,78 102,88 81,05 157,28 34,13 99,51 681,33 496921,8 100,01 1499,25 2,59 -1,97
14:40 3783,59 418,27 102,86 81 158,56 34,39 99,52 681,92 496960,8 100,01 1500,48 2,6 -2,19
14:50 3777,6 418,49 102,74 81,02 162,26 34,42 99,51 682,38 497095,4 100,01 1500,13 2,56 -2,8
15:00 3792,5 423,24 102,68 80,92 162,67 34,52 99,51 683,7 496420,6 100,03 1501,2 2,59 -3,86
15:10 3805,69 421,37 102,67 81,05 166,14 34,66 99,52 683,72 497258,8 100 1499,97 2,57 -4,01
15:20 3786,21 422,69 102,66 80,97 161,72 34,68 99,5 683,95 496811,6 100 1498,08 2,59 -2,95
15:30 3763,99 417,16 102,66 80,99 159,26 34,34 99,49 682,2 497263,4 100,03 1501,47 2,58 -3,25
15:40 3771,33 421,13 102,65 80,98 162,09 34,57 99,51 683 496789,7 99,98 1498,75 2,59 -3,13
15:50 3748,93 416,15 102,57 80,91 159,78 34,44 99,5 681,47 497299,4 99,99 1499,2 2,58 -2,91
16:00 3699,1 418,14 102,37 80,96 161,9 34,5 99,52 681,42 496935,3 99,99 1501,44 2,58 -2,76
16:10 3692,18 416,6 102,33 81,06 161,64 34,56 99,5 681,83 497324,7 100,02 1499,23 2,61 -3,19
16:20 3666,68 414,87 102,31 81 160,05 34,77 99,51 683,9 499979,7 100 1499,87 2,61 -3,44
16:30 3656,12 413,46 102,17 80,95 160,12 34,63 99,53 682,6 500171,8 100 1500,43 2,6 -3,32
16:40 3653,12 414,37 102,25 80,98 161,94 34,66 99,53 683,12 499726,6 100 1499,79 2,59 -3,6
16:50 3622,57 415,31 102,37 80,94 163,06 34,89 99,52 683,67 500254,8 100 1499,95 2,6 -3,23
17:00 3622,34 418,1 102,27 81,05 162,38 34,94 99,5 683,92 499502,3 100 1500,35 2,59 -3,16
17:10 3606,81 416,48 102,22 80,96 159,85 34,69 99,51 682,47 500846,4 100,02 1499,71 2,61 -3,53
17:20 3626,55 416,62 102,22 81,03 161,32 34,46 99,51 680,88 499858,4 100 1498,69 2,64 -3,61
17:30 3664,38 412,04 102,07 80,89 156,75 34,26 99,51 680,67 500485,3 100,01 1500,69 2,7 -3,02
17:40 3662,49 410,77 102,52 81,02 161,07 34,26 99,53 679,53 500407,7 99,99 1499,65 2,64 -4
17:50 3622,74 415,83 102,31 80,89 165,14 34,46 99,52 680,92 498836 100 1500,35 2,61 -4,42
18:00 3631,08 420,2 102,16 81,05 166,33 35,03 99,51 684,25 500134,8 100 1499,76 2,61 -4,1
18:10 3603,31 420,51 102,27 81,04 166,21 34,89 99,51 683,22 500015,4 100,01 1500,77 2,62 -4,19
18:20 3582,56 417,25 102,23 80,92 166,66 34,84 99,52 682,42 500578,8 99,99 1500,05 2,6 -4,36
162
18:30 3627,9 423,88 102,12 81,06 168,01 35,12 99,52 683,92 499312,7 100,02 1498,37 2,63 -4,07
18:40 3624,9 423,26 102,19 81,1 165,22 34,9 99,52 683,12 499992,7 99,99 1501,68 2,64 -3,94
18:50 3668,55 418,86 102,16 80,93 157,5 34,78 99,51 682,15 500631,5 100 1498,85 2,67 -3,37
19:00 3661,95 416,48 102,1 81,01 161,42 34,72 99,51 681,5 499923,9 100,02 1499,65 2,69 -3,39
19:10 3622,9 422,26 102,07 80,95 167,13 35,08 99,51 682,83 499526,3 100 1499,81 2,64 -3,9
19:20 3617,66 420,86 102,06 81,03 167 35,03 99,51 682,7 500165,9 100,01 1499,47 2,62 -3,85
19:30 3610,14 421,77 102,06 80,97 167,93 35 99,51 682,4 499769,1 99,99 1500,77 2,63 -4,31
19:40 3647,23 421,4 102,17 80,98 163,86 35,08 99,52 683,83 500550,2 100,01 1499,65 2,66 -3,62
19:50 3630,85 419,6 102,21 80,99 163,54 34,83 99,51 681,95 499481,3 100 1500,43 2,66 -3,72
20:00 3650,27 419,36 102,38 81,02 159,04 34,69 99,53 681,45 501192,1 100 1500,48 2,69 -3,31
20:10 3655,2 418,16 102,42 81,04 160,38 34,33 99,51 679,28 499857,9 100 1499,79 2,69 -3,44
20:20 3594,81 421,45 102,17 80,91 163,7 34,59 99,51 680,62 499830,9 100 1501,23 2,69 -3,79
20:30 3635,69 424,46 102,11 81,09 166,24 34,82 99,51 681,45 498891,4 100,02 1499,04 2,69 -4,1
20:40 3627,61 420,83 102,42 80,99 163,75 34,84 99,51 682,1 500509,8 100,01 1500,93 2,65 -3,58
20:50 3622,95 424,48 102,37 81,09 164,34 34,91 99,53 682,95 498830,7 100,02 1501,2 2,65 -3,41
21:00 3609,79 427,35 102,2 80,91 162,55 35 99,52 683,85 501119,5 100 1500,24 2,68 -3,79
21:10 3646,73 428,15 102,19 81,15 164,58 35,01 99,54 683,8 499045,2 99,98 1499,36 2,68 -3,34
21:20 3669,96 421,31 102,14 80,99 164,28 35,21 99,5 685,3 500244,2 100,01 1500,45 2,68 -2,8
21:30 3667,79 423,48 102,19 81,06 169,12 35,21 99,5 685,1 499730,7 99,99 1499,63 2,68 -2,99
21:40 3647,02 425,32 102,19 80,92 169,52 35,36 99,49 685,72 500222,9 99,99 1499,55 2,68 -2,91
21:50 3633,13 423,72 102,23 81 169,93 35,33 99,52 685,55 500083,1 99,99 1500,03 2,65 -3,3
22:00 3634,98 422,55 102,26 81,03 167,38 35,29 99,52 685,72 500092,3 100 1499,12 2,65 -2,8
22:10 3632,12 420,66 102,23 80,99 162,5 35,15 99,5 684,58 500352,1 100 1501,79 2,68 -2,15
22:20 3629,62 418,84 102,19 81 164,17 34,99 99,51 683,58 499803,6 100 1499,31 2,67 -3,04
22:30 3633,91 420,94 102,12 80,98 169,59 35,31 99,52 685,42 499255,9 99,97 1499,31 2,64 -2,87
22:40 3656,57 425,24 102,17 81,06 168,38 35,54 99,54 687,47 499907,5 99,99 1501,28 2,66 -2,23
22:50 3664,26 418,85 102,25 81 158,03 35,15 99,53 685,38 500671,7 99,98 1500,05 2,73 -0,77
23:00 3676,27 416,67 102,23 80,97 157,64 34,99 99,49 684,25 500070,9 100,02 1499,25 2,71 -0,75
23:10 3665,79 417,57 102,15 80,97 164,84 35,13 99,52 684,25 499564,9 100,01 1501,04 2,68 -2,11
23:20 3672,87 420,33 102,05 80,98 164,89 35,26 99,51 685,5 499985,7 100,04 1501,15 2,7 -1,88
Promedio 3706,73 417,72 102,94 81,00 165,65 34,26 99,52 678,59 495096,20 100,36 1438,65 2,65 -2,76
Fuente: La empresa
163
Toneladas producidas: 165,65 TM/h. (Ver tabla 24).
Consumo de energía: 33,59 KW-h/TM. (Ver anexo 10).
Consumo de aditivo: 355,03 gr/TM. (Ver anexo 10).
164
03:30 3775,98 405,49 102,72 81 158,88 33,85 99,53 676,53 500290,6 99,98 1499,63 2,75 -2,63
03:40 3743,48 408,65 102,48 80,77 165,63 34 99,51 677,22 499307,4 100 1499,49 2,72 -3,1
03:50 3659,7 409,51 102,35 81,02 172,31 34,2 99,5 677,97 500036,7 100,01 1501,68 2,69 -3,38
04:00 3643,71 408,85 102,35 80,98 172,59 34,17 99,5 678 500067,7 100,04 1499,36 2,69 -3,51
04:10 3660,73 410,96 102,4 81,05 171,67 34,17 99,52 678,05 499829,5 100,01 1500,45 2,68 -3,35
04:20 3655,14 409,03 102,36 80,91 172,48 34,05 99,53 677,35 500442,1 99,99 1500,67 2,68 -3,72
04:30 3681,79 408,31 102,4 81,04 172,46 33,95 99,51 676,67 500219,8 100,02 1500,05 2,72 -3,63
04:40 3700,91 405,4 102,34 81,02 165,29 33,85 99,5 676,33 499965,8 99,99 1498,91 2,75 -3,28
04:50 3515,99 379,54 101,61 78,56 168,92 33,91 99,51 676,62 508385,4 99,99 1499,36 2,75 -4,06
05:00 3586,54 396,55 102,17 80,21 170,92 33,83 99,52 674,62 499161,8 100 1500,45 2,72 -4,07
05:10 3594,98 403,9 102,21 81,19 173,3 34,12 99,53 677,42 499627,4 99,99 1499,12 2,72 -4,21
05:20 3645,95 403,64 102,25 81,07 170,56 34,07 99,51 677,62 500234,6 100,02 1499,71 2,73 -4,14
05:30 3633,32 401,9 102,24 81,01 168,05 33,91 99,53 676,17 500222,9 99,98 1499,55 2,72 -4,06
05:40 3584,33 404,78 102,54 80,94 173,29 34,01 99,49 676,83 499726,8 99,99 1501,15 2,73 -4,33
05:50 3619,48 407,8 102,59 81,06 170,64 34,16 99,51 677,95 500133,1 100,05 1499,15 2,75 -4,33
06:00 3659,17 404,01 102,73 81,09 167,33 33,95 99,52 676,62 500110,3 100,02 1500,48 2,73 -4,1
06:10 3625,33 401,52 102,54 80,93 167,41 33,85 99,52 676,4 500020,1 99,96 1500 2,74 -4,06
06:20 3621,9 407,67 102,52 81,02 169,23 34,11 99,51 677,58 499827,4 99,98 1499,71 2,74 -4,27
06:30 3604,45 407,67 102,45 81,03 168,17 34,05 99,51 676,75 500153,8 100,03 1499,57 2,76 -4,17
06:40 3637,05 406,18 102,46 81,07 163,79 33,86 99,49 676,17 500192,6 99,98 1499,87 2,75 -3,81
06:50 3612,33 409,65 102,27 80,94 168,7 33,97 99,51 676,58 499544,4 99,99 1499,31 2,75 -4,13
07:00 3596,49 412,3 102,12 80,91 173,56 34,16 99,51 678 499758,3 100,01 1499,2 2,74 -4,4
07:10 3652,2 407,23 102,48 81,21 167,08 34,08 99,52 677,55 500401,2 100,05 1500,27 2,81 -4
07:20 3686,37 404,13 102,64 81,04 157,27 33,75 99,52 676,35 500117,3 100 1499,95 2,79 -3,58
07:30 3689,08 407,29 102,6 80,96 163,76 33,91 99,51 676,65 499654,1 99,97 1500,29 2,76 -3,79
07:40 3640,36 408,18 102,61 80,97 166,84 34,11 99,52 677,78 500022,3 100,02 1500,56 2,75 -4,02
07:50 3662,65 408,71 102,69 81,06 171,31 34,35 99,52 679,38 499316,8 99,98 1500,32 2,73 -4,15
08:00 3622,11 401,77 102,94 80,98 168,03 34,11 99,5 678,5 500154,8 100,02 1499,73 2,73 -4,38
08:10 3653,17 407,81 103,11 81,07 169,17 34,39 99,51 679,12 500111,3 100 1500,03 2,72 -4,47
08:20 3661,41 406,52 103,45 80,97 168,38 34,25 99,52 678 500043,8 100 1499,44 2,73 -4,42
08:30 3678,15 404,15 103,83 81,04 166,49 34,2 99,51 678 499963,4 100,01 1499,6 2,71 -4,34
08:40 3668,44 404,5 103,11 80,92 167,56 34,17 99,53 678,12 499769,3 100 1500,11 2,69 -4,49
08:50 3637,85 406,96 103,22 81,02 168,77 34,26 99,52 679 499941,7 99,98 1500,99 2,67 -4,53
09:00 3611,05 411,6 103,25 81,04 171,83 34,37 99,53 679,72 499781,6 100 1500,29 2,71 -4,63
09:10 3639,73 411,91 103,5 81,05 172,65 34,41 99,49 679,92 499921,3 99,99 1498,83 2,7 -4,63
09:20 3687,39 408,41 103,63 81,05 167,43 34,22 99,52 678,97 500594,2 99,98 1500,75 2,68 -4,49
09:30 3727,49 404,46 103,76 81 161,45 33,96 99,5 678 500075,6 100 1499,79 2,73 -4,34
165
09:40 3678,49 406,75 103,83 80,94 165,81 34,02 99,51 678,1 499844,2 99,99 1500,59 2,68 -4,62
09:50 3636,17 411,14 103,7 81 171,6 34,23 99,53 679,62 499547,6 99,99 1499,89 2,69 -4,97
10:00 3659,89 412,56 103,52 81,06 170,75 34,39 99,52 680,53 500061,8 100,02 1499,89 2,66 -5,04
10:10 3627,4 407,29 103,52 80,92 171,28 34,26 99,49 679,65 499976,2 100,02 1499,39 2,68 -5,27
10:20 3640,31 408,12 103,66 81,04 173,37 34,36 99,5 680,97 499911,2 99,97 1499,79 2,65 -5,29
10:30 3656,74 408,05 103,87 81,06 172,69 34,24 99,51 680,42 500054,3 99,98 1501,47 2,66 -5,38
10:40 3615,55 411,52 103,59 80,95 172,58 34,33 99,51 680,53 499940,8 100 1500,45 2,65 -5,48
10:50 3677,28 411,05 103,86 81,07 169,21 34,21 99,5 680,55 500101,3 100,02 1499,31 2,68 -5,38
11:00 3669,54 408,04 103,59 80,99 165,83 34,12 99,52 679,47 500016,1 99,99 1500,27 2,68 -5,24
11:10 3663,75 409,17 103,74 81,01 165,41 34,01 99,51 679,5 500024,9 99,98 1499,79 2,65 -5,35
11:20 3652,33 411,28 103,68 80,96 167,5 34,11 99,52 680,35 499704,8 100,02 1499,92 2,65 -5,41
11:30 3646,24 412,61 103,73 81,04 168,47 34,24 99,51 681 500177,7 100 1500,69 2,67 -5,39
11:40 3686,57 409,61 103,8 80,97 162,32 34,02 99,52 679,95 500135,4 100 1499,84 2,71 -5,15
11:50 3657,1 410,5 103,78 80,92 166,02 34,13 99,52 680,08 499812,4 99,97 1500,19 2,69 -5,21
12:00 3607,78 412,45 103,66 80,98 173,5 34,28 99,52 681,45 499578,6 100,01 1499,33 2,67 -5,49
12:10 3605,82 418,4 103,58 80,99 176,97 34,64 99,51 683,12 500065,6 100,02 1500,21 2,65 -5,53
12:20 3679,79 412,53 103,94 81,15 168,18 34,23 99,51 681,38 500483,8 99,98 1499,63 2,67 -5,16
12:30 3692,44 410,7 103,56 80,94 161,19 34,12 99,52 680,72 500201,3 100 1500,03 2,72 -4,84
12:40 3666,01 410,85 103,56 81,02 162,95 34,06 99,53 679,65 499919,3 100 1498,72 2,69 -4,75
12:50 3735,43 412,92 103,66 81,04 159,48 34,35 99,53 681,55 499472,7 99,99 1501,23 2,74 -3,83
13:00 3714,33 416,71 103,49 80,85 165,63 34,63 99,52 683,4 500003,1 99,97 1499,39 2,7 -3,53
13:10 3654,54 416,05 103,3 80,99 172,65 34,53 99,51 682,03 500387,6 100 1500,24 2,69 -4,05
13:20 3635,91 415,46 103,29 80,93 174,43 34,4 99,52 681,17 499857,2 99,99 1499,41 2,7 -4,27
13:30 3625,6 417,41 103,15 80,97 177,33 34,5 99,51 682,35 500054,3 99,98 1499,49 2,7 -4,43
13:40 3626,46 418,08 103,15 81,05 175,42 34,26 99,51 680,6 500647,2 100 1500,93 2,69 -4,96
13:50 3577,97 416,08 103,17 81,05 175,84 34,3 99,52 680,4 499339,2 100 1498,02 2,67 -5,16
14:00 3620,26 427,14 103,13 81,04 176,44 34,8 99,52 683,97 499241,7 99,97 1501,15 2,67 -4,9
14:10 3594,89 430,02 103,07 81,11 177,27 35,25 99,53 686,03 499438,9 100,02 1498,45 2,63 -5,38
14:20 3639,6 429,89 103,22 80,96 170,75 35,4 99,49 687,8 502388,3 99,98 1501,58 2,65 -4,96
Promedio 3657,57 411,37 102,92 80,97 168,38 34,34 99,51 679,82 500112,78 100,00 1499,95 2,71 -3,91
Fuente: La empresa
166
Toneladas producidas: 168,38 TM/h. (Ver tabla 25).
Consumo de energía: 32,73 KW-h/TM. (Ver anexo 10).
Consumo de aditivo: 364,2 gr/TM. (Ver anexo 10).
Descripción Unidad M1P M1HE M2HE M3HE M4HE Promedio MHE Diferencia
Toneladas
producidas TM/h 181,32 159,36 161,03 165,65 168,38 163,605 9,77%
Consumo KW-
de energía h/TM 32,3 34,74 34,59 33,59 32,73 33,9125 4,99%
Consumo
de aditivo gr/TM 344,72 370,13 388,48 355,03 364,2 369,46 7,18%
Fuente: Elaboración propia
El promedio de los indicadores de las cuatro muestras de cemento portland puzolánico tipo HE se indica en la penúltima
columna, la cual está siendo comparada con los indicadores de producción del cemento portland puzolánico 1P.
La productividad es mejor en el caso del cemento portland puzolánico tipo 1P en los tres indicadores descritos; mayor
cantidad de toneladas producidas, menor consumo de energía y menor consumo de aditivo de molienda. Con esto se
demuestra la necesidad de una mejora.
167
3.6 Pérdida económica
En la tabla 27 se observa la pérdida económica que implica la producción de cementos portland puzolánicos tipo HE en
el molino vertical LM 56 2 + 2 CS.
168
O Ingresos S/ 1.852.235 S/ 1.942.024 -S/ 89.788 Anexo 12
P Utilidad S/ 1.349.913 S/ 1.512.141 -S/ 162.228 O-N
Q Costo anual S/ 24.111.464 S/ 20.634.348 S/ 3.477.116 N*4*12
R Ingreso anual S/ 88.907.294 S/ 93.217.129 -S/ 4.309.835 O*4*12
S Utilidad anual S/ 64.795.830 S/ 72.582.782 -S/ 7.786.951 R-Q
Fuente: Elaboración propia en base a información aproximada de la empresa
Se observa que la planta está dejando de percibir S/.7.786.951 al año por producir cemento portland tipo HE con una
productividad de 164 TM/h.
169
De la tabla 27 se mencionan los siguientes aspectos:
170
CAPÍTULO IV
171
PROPUESTA DEL MÉTODO
172
En la figura 78, se detalla el esquema general que tiene el método propuesto; se van
a desarrollar las 5 etapas en base a los principios del Seis Sigma y aplicados a la
producción de cemento tipo HE en el molino vertical LM 56 2 + 2 CS, con la finalidad
de incrementar su productividad.
En los siguientes apartados se describe cada una de las 5 etapas del método
propuesto.
173
Para poder determinar la importancia del problema, se pueden listar todos los
problemas que afectan la producción de cementos portland de alta resistencia
inicial y observar cuál de ellos es el que más se repite, este análisis se puede
realizar utilizando un diagrama de Pareto.
Es conveniente que las causas sean lo más amplias posibles y de toda índole,
es decir, causas de la operación del molino, causas ajenas a la operación,
defectos en el análisis del producto, defectos en la capacitación del personal,
defectos en las materias primas, defectos en las mediciones, etc. Estas se
pueden representar en un diagrama de Ishikawa.
174
Figura 79: Herramientas y metas de la metodología DMAIC
Luego de tener claro el marco del estudio, se van a definir los requerimientos del
cliente mediante la voz del cliente, esta herramienta recoge toda la información
que los clientes necesitan para estar satisfechos.
175
Una vez que se tienen dichos procesos, se va a realizar el diagrama SIPOC de
cada uno para conocerlos más a detalle.
176
Las calibraciones las hace una persona capacitada y con experiencia, muchas
veces son realizadas por profesionales de las empresas que suministran los
equipos o instrumentos.
Estos resultados se comparan con los estándares, y de esta forma, se tiene una
idea de donde está posicionado el proceso de molienda de cemento de alta
resistencia inicial y cuanto falta por mejorar.
Para poder realizar la capacidad del proceso y el nivel sigma, los datos deben de
ser normales y estar bajo control estadístico, por lo que se utilizará la prueba de
normalidad y los gráficos de control respectivamente.
177
En la etapa analizar, se van a evaluar las causas posibles del problema principal
mediante el análisis FMEA. Esta herramienta va a servir de filtro para reducir el
número de causas posibles.
178
También se va a utilizar el diseño de experimentos (DOE) en el caso de que
existan parámetros de operación del molino que tengan que ser configurados de
una manera óptima.
179
Figura 84: Etapa controlar
180
CAPÍTULO V
181
VALIDACIÓN DEL MÉTODO
Los procesos estratégicos están ligados con las partes interesadas y con los procesos
operativos, de tal forma que haya una adecuada gestión.
182
Figura 85: Mapa de procesos de la planta de cemento
184
Figura 86: Problemas en la producción de cemento tipo HE
100.000%
100 90.000%
80.000%
80 70.000%
60.000%
60
50.000%
Frecuencia
40.000%
40 % acumulado
30.000%
20.000%
20
10.000%
0 .000%
Baja Vibraciones Tiempo de Baja calidad Fallas Fallas Fallas
productividad elevadas del producción de del cemento eléctricas y operativas mecánicas
molino calidad electrónicas
185
Como se observa en la figura 86, la baja productividad es mucho mayor que los
demás ítems mostrados, por lo que es importante solucionarla, de esta forma se
podrán reducir los problemas en la producción de cemento tipo HE del molino vertical
en al menos 50%.
Para definir todas las causas posibles, a parte del criterio del autor, se realizó una
encuesta a 3 operadores del molino (anexo 14), de tal manera que la lista tenga
mayor valor.
186
Falta de mantenimiento.
187
En la figura 87 se observan las causas posibles agrupadas en un diagrama de
Ishikawa para tener un mejor panorama.
188
Potenciales No se cuenta con el conocimiento exacto acerca de la dinámica
partes de fluidos y termodinámica que ocurre dentro del molino al
producir cemento.
Se desconoce si la capacidad de los equipos tanto principales
como auxiliares es apta para el objetivo de incrementar la
productividad para este tipo de cemento en particular.
Interesados Gerencia general.
Control de calidad.
Comercialización.
Ensacado y despacho.
Mantenimiento.
Materias primas.
Fuente: Elaboración propia
189
A partir de la tabla anterior se van a consolidar los requerimientos para poder
generar la matriz QFD:
190
Tabla 31: Matriz QFD
Ensacado y despacho
Molienda de cemento
Molienda de carbón
Molienda de crudo
Comercialización
Homogenización
Requerimientos del cliente
Clinkerización
Ponderación
Trituración
Extracción
Reducir inspecciones de los equipos 3 5 3 1 1 3 5 5 0 0
del molino por inestabilidad
Reducir inspecciones de materias 3 5 3 1 0 3 5 5 0 0
primas
Obtener muestras representativas 3 0 1 1 1 1 1 5 3 3
de cemento HE
Incrementar la productividad del 5 1 1 1 1 3 3 5 1 1
cemento HE en el molino vertical
Operación estable del molino vertical 4 3 1 0 0 3 3 5 0 0
Calidad óptima del cemento HE 5 5 5 3 3 5 5 5 5 5
Stock suficiente de cemento HE 4 3 3 1 1 1 3 1 5 5
Importancia 79 74 40 37 104 124 454 120 90
Importancia relativa 2 2 1 1 2 3 10 2 2
Fuente: Elaboración propia
191
Tabla 32: Diagrama SIPOC del proceso de clinkerización
Sistema de Suministro de
compresores y agua y aire a los
bombas de agua equipos del
de planta. horno.
192
Tabla 33: Diagrama SIPOC del proceso de molienda de cemento
Centrales Suministro de
generadoras de energía eléctrica.
energía eléctrica.
Sistema de Suministro de
compresores y agua y aire a los
bombas de agua equipos del
de planta. molino.
Ensacado y Stock de
despacho cemento tipo HE.
Fuente: Elaboración propia
Como ya se indicó en la parte teórica, las balanzas son los equipos que
dosifican los minerales y entregan un flujo controlado al sistema de molienda. Se
va a validar el sistema de medición mediante un método de calibración de dichos
equipos.
193
La correcta calibración de las balanzas dosificadoras garantiza que el flujo de
alimentación tenga un error mínimo en la medición y por lo tanto los valores sean
confiables.
194
En la tabla 34 se muestran las calibraciones de las 4 balanzas del molino
realizadas en el mes 1 del año 2015.
195
evidencia significativa para afirmar que los datos no siguen una distribución
normal, por lo tanto, se acepta "H0".
196
Figura 89: Gráfico de control I-MR – situación actual
Productividad - situación actual
170
UCL=169,23
Individual Value
165
_
X=162,92
160
LCL=156,61
155
1 4 7 10 13 16 19 22 25 28
Observation
8 UCL=7,752
6
Moving Range
4
__
MR=2,373
2
0 LCL=0
1 4 7 10 13 16 19 22 25 28
Observation
Luego de tener los datos normales y bajo control estadístico se procede a hallar
los valores de capacidad y nivel sigma del proceso.
197
Figura 90: Capacidad del proceso – situación actual
Según la figura 91, el nivel sigma es -3,36, el cual indica, así como los índices
"Cp" y "Cpk" anteriores, que es un proceso totalmente incapaz y requiere de
urgente mejora.
198
Figura 91: Nivel sigma del proceso – situación actual
199
Tabla 35: Análisis FMEA
200
SCADA
Equipos de Equipos de Datos de calidad Baja productividad Falta de mantenimiento de 3 3 4 36
laboratorio laboratorio no erróneos equipos de laboratorio
calibrados
Muestreo Procedimiento Datos de calidad Baja productividad Técnicas inadecuadas de 3 3 3 27
de muestreo erróneos muestreo
inadecuado
Máquinas Capacidad de Falta de Proceso Baja productividad No realizar mejoras en los 3 2 6 36
los equipos capacidad de productivo no equipos del molino
los equipos controlado
Mantenimiento Falta de Paros del molino Baja productividad Inadecuados programas de 7 2 2 28
mantenimiento mantenimiento
Métodos Flujo de gas Flujo de gas Vibración alta del Baja productividad Baja calidad del cemento, equipos 4 10 2 80
del molino inadecuado molino y/o baja calidad del principales con desgaste y/o
producto variación en las características
físicas de las materias primas
Flujo de agua Flujo de agua Vibración alta del Baja productividad Baja calidad del cemento, equipos 4 10 2 80
del molino inadecuado molino y/o baja calidad del principales con desgaste y/o
producto variación en las características
físicas de las materias primas
Velocidad del Velocidad Vibración alta del Baja productividad Baja calidad del cemento, equipos 4 10 2 80
clasificador inadecuada molino y/o baja calidad del principales con desgaste y/o
dinámico del clasificador producto variación en las características
dinámico físicas de las materias primas
Presión Presión Vibración alta del Baja productividad Baja calidad del cemento, equipos 4 8 2 64
hidráulica de hidráulica de molino y/o baja calidad del principales con desgaste y/o
rodillos rodillos producto variación en las características
inadecuada. físicas de las materias primas
Equipos de Desgaste de Vibración alta del Baja productividad Falta de mantenimiento 6 2 3 36
molienda los equipos de molino y/o baja calidad del
molienda producto
Medio Guías técnicas Falta de guías Variabilidad en el Baja productividad Falta de estandarización 3 2 2 12
ambiente de operación técnicas de proceso y/o baja calidad del
(entorno) operación productivo producto
Fuente: Elaboración propia
201
Luego de haber realizado el análisis FMEA, las variables críticas que más
podrían influir en la baja productividad cuando el molino vertical produce
cemento portland tipo HE, son las siguientes:
202
Figura 92: Análisis de correlación para el C3S
Los datos del caso anterior también serán usados para realizar el
análisis de varianza. Primero se debe verificar que los datos siguen una
distribución normal, para ello se realiza la prueba de Anderson – Darling.
203
En la figura 93, los datos presentan una media de 162,4, desviación
estándar de 6,201 y un valor de "p" de 0,960; este valor al ser mayor que
0,05, indica que no existe evidencia significativa para afirmar que los
datos no siguen una distribución normal, por lo tanto, se acepta "H 0".
204
Figura 94: Productividad con 70,57% de C3S
205
Figura 95: Productividad con 71,76% de C3S
206
Figura 96: Prueba de igualdad de varianzas para el C3S
Multiple Comparisons
P-Value 0,750
69,46 Levene’s Test
P-Value 0,485
70,57
71,76
3 4 5 6 7 8 9 10 11
En la figura 96, el valor de "p" es 0,485, este valor al ser mayor que 0,05,
indica que no existe evidencia significativa para afirmar que no todas las
varianzas son iguales, por lo tanto, se acepta "H 0", es decir todas las
varianzas son iguales.
207
Figura 97: Análisis de varianza del C3S del clinker
En la figura 97, el valor de "p" es de 0,455, este valor al ser mayor que
0,05, indica que no existe evidencia significativa para afirmar que las
medias de los tratamientos son diferentes, por lo tanto, se acepta "H0",
es decir las medias de los tratamientos son iguales.
Al ser mayor el valor del error (1029,87) que el valor del factor (51,91),
quiere decir que la variabilidad entre tratamientos es menor que la
variabilidad dentro de cada tratamiento, y por lo tanto las medias de los
tratamientos tienden a alinearse.
208
La hipótesis nula indica que no hay diferencias significativas entre las
medias de los tratamientos, por lo tanto, se determina que el C3S del
clinker no influye en la productividad del molino en la producción de
cementos portland tipo HE.
209
Figura 99: Gráfico de intervalos para el C3S del clinker
165,0
162,5
Data
160,0
157,5
155,0
69,46 70,57 71,76
210
H1: Los datos no siguen una distribución normal.
211
Figura 101: Productividad con 99,93°C
212
0,05, indica que no existe evidencia significativa para afirmar que los
datos no siguen una distribución normal, por lo tanto, se acepta "H 0".
Multiple Comparisons
P-Value 0,033
T 131,53 Levene’s Test
P-Value 0,115
T 99,93
T 42,05
En la figura 103, el valor de "p" es 0,115, este valor al ser mayor que
0,05, indica que no existe evidencia significativa para afirmar que no
todas las varianzas son iguales, por lo tanto, se acepta "H 0", es decir
todas las varianzas son iguales.
213
Adicionalmente a la prueba de normalidad y de igualdad de varianzas,
se determina que los datos si provienen de poblaciones independientes,
ya que son distintos valores de temperatura y los datos también son
aleatorios.
214
Figura 104: Análisis de varianza de la temperatura del clinker
En la figura 104, el valor de "p" es de 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que las medias de
los tratamientos son diferentes, por lo tanto, se rechaza "H 0", es decir las
medias de los tratamientos son diferentes.
Al ser menor el valor del error (138,6) que el valor del factor (2484,4),
quiere decir que la variabilidad entre tratamientos es mayor que la
215
variabilidad dentro de cada tratamiento y por lo tanto las medias de cada
tratamiento tienden a alejarse una de la otra.
216
Figura 105: Gráfico de residuos para la temperatura del clinker
170
168
166
Data
164
162
160
158
T 131,53 T 99,93 T 42,05
217
5.4.3.3 Flujo de gas
218
Figura 107: Productividad con 499954 m3/h
219
Figura 109: Productividad con 472876 m3/h
220
Figura 110: Prueba de Levene para el flujo de gas
Multiple Comparisons
P-Value 0,000
499954 Levene’s Test
P-Value 0,000
472876
484060
0 1 2 3 4 5
En la figura 110, el valor de "p" es 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que no todas las
varianzas son iguales, por lo tanto, se rechaza "H0", es decir no todas las
varianzas son iguales.
221
Figura 111: Prueba de Barlett para el flujo de gas
472876
484060
0 1 2 3 4 5
95% Bonferroni Confidence Intervals for StDevs
222
Figura 112: Análisis de varianza del flujo de gas del molino
En la figura 112, el valor de "p" es de 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que las medias de
los tratamientos son diferentes, por lo tanto, se rechaza "H 0", es decir las
medias de los tratamientos son diferentes.
223
Por lo tanto, se determina que el flujo de gas influye en la productividad
del molino en la producción de cementos portland tipo HE.
224
Figura 114: Gráfico de intervalos para el flujo de gas
165,5
165,0
164,5
Data
164,0
163,5
163,0
162,5
499954 472876 484060
Las muestras por utilizar serán la productividad para 1812 litros/h, 1100
litros/h y 1500 litros/h.
225
Para un nivel de significancia de 95%, se tiene que "α" es 1-0,95 = 0,05.
226
Figura 116: Productividad con 1500 litros/h
227
que 0,05, indica que no existe evidencia significativa para afirmar que los
datos no siguen una distribución normal, por lo tanto, se acepta "H 0".
Multiple Comparisons
P-Value 0,001
1812 Levene’s Test
P-Value 0,002
1100
1500
En la figura 118, el valor de "p" es 0,002, este valor al ser menor que
0,05, indica que existe evidencia significativa para afirmar que no todas
las varianzas son iguales, por lo tanto, se rechaza "H0", es decir no todas
las varianzas son iguales.
228
Se verificó la afirmación anterior con la prueba de Barlett, la cual también
indica que no todas las varianzas son iguales.
1100
1500
229
Figura 120: Análisis de varianza del flujo de agua del molino
En la figura 120, el valor de "p" es de 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que las medias de
los tratamientos son diferentes, por lo tanto, se rechaza "H 0", es decir las
medias de los tratamientos son diferentes.
230
Por lo tanto, se determina que el flujo de agua influye en la productividad
del molino en la producción de cementos portland tipo HE.
231
Figura 122: Gráfico de intervalos para el flujo de agua
166
164
Data
162
160
Las muestras por utilizar serán la productividad para 103 rpm, 97 rpm y
100 rpm.
232
H1: Los datos no siguen una distribución normal.
233
Figura 124: Productividad con 100 rpm
234
que 0,05, indica que no existe evidencia significativa para afirmar que los
datos no siguen una distribución normal, por lo tanto, se acepta "H0".
Multiple Comparisons
P-Value 0,000
103 Levene’s Test
P-Value 0,000
97
100
0 1 2 3 4 5 6
En la figura 126, el valor de "p" es 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que no todas las
varianzas son iguales, por lo tanto, se rechaza "H0", es decir no todas las
varianzas son iguales.
235
Se verificó la afirmación anterior con la prueba de Barlett, la cual también
indica que no todas las varianzas son iguales.
97
100
0 1 2 3 4 5 6
95% Bonferroni Confidence Intervals for StDevs
236
Figura 128: Análisis de varianza velocidad del clasificador dinámico
En la figura 128, el valor de "p" es de 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que las medias de
los tratamientos son diferentes, por lo tanto, se rechaza "H 0", es decir las
medias de los tratamientos son diferentes.
237
Por lo tanto, se determina que la velocidad del clasificador dinámico
influye en la productividad del molino en la producción de cementos
portland tipo HE.
238
Figura 129: Gráfico de residuos velocidad del clasificador dinámico
170
168
166
Data
164
162
160
103 97 100
239
5.4.3.6 Presión hidráulica de los rodillos
Las muestras por utilizar serán la productividad para 102 BAR, 95 BAR y
97 BAR.
240
Figura 131: Productividad con 102 BAR
241
0,05, indica que no existe evidencia significativa para afirmar que los
datos no siguen una distribución normal, por lo tanto, se acepta "H 0".
242
Figura 134: Prueba de Levene para la presión hidráulica
Multiple Comparisons
P-Value 0,000
102 Levene’s Test
P-Value 0,000
95
97
0 1 2 3 4 5 6 7 8
En la figura 134, el valor de "p" es 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que no todas las
varianzas son iguales, por lo tanto, se rechaza "H0", es decir no todas las
varianzas son iguales.
243
Figura 135: Prueba de Barlett para la presión hidráulica
95
97
0 1 2 3 4 5 6 7
95% Bonferroni Confidence Intervals for StDevs
244
Figura 136: Análisis de varianza de la presión hidráulica
En la figura 136, el valor de "p" es de 0, este valor al ser menor que 0,05,
indica que existe evidencia significativa para afirmar que las medias de
los tratamientos son diferentes, por lo tanto, se rechaza "H 0", es decir las
medias de los tratamientos son diferentes.
245
Por lo tanto, se determina que la presión hidráulica influye en la
productividad del molino en la producción de cementos portland tipo HE.
246
Figura 137: Gráfico de residuos para la presión hidráulica
170
169
168
Data
167
166
165
164
163
102 95 97
247
Tabla 37: Resumen del análisis de las variables críticas
Variable Valor de Hipótesis R2 ¿Influye en la ¿Pasa a
p aceptada productividad? etapa de
mejora?
C3S del 0,455 H0 0 NO NO
clinker
Temperatura 0 H1 94,59 SI SI
del clinker
Flujo de gas 0 H1 7,55 SI NO
Flujo de 0 H1 92,28 SI SI
agua
Velocidad 0 H1 75,68 SI SI
del
clasificador
dinámico
Presión 0 H1 43,92 SI SI
hidráulica de
los rodillos
Fuente: Elaboración propia
El C3S del clinker no pasará a la etapa mejorar ya que se demostró que no influye en
la productividad del molino, mientras que el flujo de gas tampoco será elegido ya que
tiene un valor de R2 muy bajo.
248
5.4.4 Etapa mejorar
Planear
249
La faja 2 es una faja reversible con un vibrador que alimenta clinker
hacia el molino vertical y también hacia los molinos de bolas de la planta,
este vibrador tiene una capacidad de 100 TM/h.
250
Cuando se produce cementos portland tipo HE, se ha demostrado que
utilizar clinker con alta temperatura reduce la productividad, en el caso
de la planta, es porque se alimenta clinker desde los puntos 1 y 2.
251
Las figuras 139 y 140 han sido realizadas en base a los anexos 31 y 32.
Hacer
Producto: Clinker.
Capacidad: 300 TM/h.
Densidad del material: 1,3 TM/m3.
Tamaño de grano: 0 – 50 mm.
Humedad: 0,3%.
Temperatura: < 140°C.
Características del producto: Fluido, polvoso, abrasivo.
Diseño de la estructura:
252
Accionamiento:
Fuente: La empresa
253
La instalación del equipo la realizará una empresa contratista, los costos
para realizar el montaje se muestran a continuación en la tabla 38:
Verificar
254
La productividad del molino de 170 TM/h utilizando clinker con 42°C, se
alcanzó suministrando el material de los vibradores 1 y 2, con la
diferencia de que, en esas fechas, durante 10 días, el horno dejo de
producir debido al mantenimiento anual, y, por lo tanto, la zona de
almacenamiento se enfrió de forma natural.
255
Actuar
256
Asumiendo una productividad optimizada del molino de 175 TM/h, se
puede trabajar 17,14 horas para llegar al requerimiento de cemento de
3000 TM semanales.
257
En la tabla 42, se muestra el diseño propuesto con la herramienta
MINITAB, mediante la cual se indican los experimentos a realizar.
258
Tabla 43: Resultados de los experimentos
Flujo de agua Velocidad del Presión Productividad
(l/h) clasificador dinámico hidráulica de (TM/h)
(rpm) los rodillos M
(BAR)
1100 100 97 164
1500 100 97 165
1100 103 97 175
1500 103 97 176
1100 100 102 177
1500 100 102 177
1100 103 102 168
1500 103 102 166
Fuente: Elaboración propia
259
Figura 142: Gráfica de efectos
260
La gráfica de cubo muestra cuales son los valores óptimos para la
velocidad del clasificador dinámico y presión hidráulica de los rodillos
máster, los cuales son 100 rpm y 102 BAR para obtener una
productividad de 177 TM/h.
261
En la figura 144, los datos presentan una media de 177,3, desviación estándar
de 2,263 y un valor de "p" de 0,068; este valor al ser mayor que 0,05, indica que
no existe evidencia significativa para afirmar que los datos no siguen una
distribución normal, por lo tanto, se acepta "H0".
En la figura 145 se observa que los datos se encuentran bajo control estadístico.
262
Figura 145: Grafico de control I-MR
180
Individual Value
_
177 X=177,25
174
LCL=172,33
171
1 4 7 10 13 16 19 22 25 28
Observation
6,0 UCL=6,044
4,5
Moving Range
3,0
__
MR=1,85
1,5
0,0 LCL=0
1 4 7 10 13 16 19 22 25 28
Observation
El índice "Cpk" (centralidad) de 0,56, el cual indica que es un proceso que a largo
plazo debe mejorar. Asimismo, se ve que en total hay 46859,61 partes por millón
fuera de las especificaciones.
263
Figura 146: Capacidad del proceso – situación propuesta
Según la figura 147, el nivel sigma es 1,68, el cual indica que sigue siendo un
proceso no capaz, pero ha mejorado considerablemente con respecto a la
situación actual.
264
Figura 147: Nivel sigma del proceso – situación propuesta
265
5.4.5 Etapa controlar
266
Motor Monitoreo de M Diario
temperaturas de
rodamientos
Monitoreo vibracional de M Diario
rodamientos
Verificación de estado de M Diario
pernos de anclaje y base
Verificación de la M Diario
presencia de ruidos
extraños e identificación
de la fuente
Verificación del M Diario
funcionamiento del
ventilador de
refrigeración
Prueba de aislamiento P Semestral
del motor
Reductor Monitoreo de M Diario
temperaturas del reductor
Monitoreo vibracional del M Diario
reductor
Verificación de estado de M Diario
pernos de anclajes y
bases
Verificación de nivel y M Diario
color de aceite
Verificación de la M Diario
presencia de ruidos
extraños e identificación
de la fuente
Inspección de P Anual
componentes internos
267
Verificación de limpieza M Semanal
del respiradero de aceite
Muestreo de aceite P Anual
Verificación de fugas de M Diario
aceite
Fuente: Elaboración propia
268
Tabla 47: Plan de mantenimiento predictivo para el clasificador dinámico
Componente Actividad Estado (Parado o en Frecuencia
marcha)
Motor Monitoreo de temperaturas de M Diario
rodamientos
Monitoreo vibracional de M Diario
rodamientos
Verificación de estado de M Diario
pernos de anclaje y base
Verificación de la presencia de M Diario
ruidos extraños e identificación
de la fuente
Verificación del funcionamiento M Diario
del ventilador de refrigeración
Prueba de aislamiento del P Semestral
motor
Inspección del motor con M Semanal
cámara Termográfica
Verificación del estado del M Semanal
sensor de marcha
Reductor Monitoreo de temperaturas del M Diario
reductor
Monitoreo vibracional del M Diario
reductor
Verificación de estado de M Diario
pernos de anclajes y bases
Verificación de nivel y color de M Diario
aceite
Verificación de la presencia de M Diario
ruidos extraños e identificación
de la fuente
Inspección de componentes P Semestral
269
internos
Verificación de limpieza del M Semanal
respiradero de aceite
Muestreo de aceite P Semestral
Verificación de fugas de aceite M Diario
Verificación del estado del M Diario
acoplamiento
Verificación del estado de M Semanal
sensores de temperatura y
presión de aceite
Álabes Verificación de estado y P Semanal
móviles registro de desgaste de los
álabes
Verificación de estado de topes P Semanal
Álabes fijos Verificación de estado de los P Semanal
álabes
Verificación del estado de P Semanal
cubos soporte
Cuerpo del Verificación del estado del sello P Semanal
clasificador de alta eficiencia
Verificación del estado de P Semanal
juntas de expansión
Verificación del estado del P Semanal
recubrimiento con cerámico del
cuerpo
Verificación del estado de M Semanal
termocupla
Fuente: Elaboración propia
En el caso del clasificador dinámico, si han existido averías durante el año 2015
(anexo 46), esto se debe que el equipo trabaja a velocidades altas del motor
270
para poder obtener la fineza del producto final, teniendo como consecuencia
desgaste prematuro tanto en los componentes internos como externos.
En la figura 148 se observan la cantidad de averías del equipo por cada modo de
falla ocurrido.
271
Figura 148: Averías en el clasificador dinámico en el año 2015
272
Según la figura 148, los trabajos más críticos son las siguientes:
273
Cambio de reductor P Según condición
Cambio de aceite P Anual
Cambio del P Según condición
acoplamiento
Cambio de sensores P Anual
de temperatura
Cambio de sensor P Anual
de presión de aceite
Álabes Cambio de álabes P Trimestral
móviles móviles
Cambio de topes P Semestral
Álabes fijos Cambio de álabes P Trimestral
fijos
Cambio de cubos P Trimestral
soporte
Cuerpo del Cambio del sello de P Semestral
clasificador alta eficiencia
Cambio de junta de P Semestral
expansión
Ordenamiento del P Semestral
cableado para
instrumentos
Relleno con P Semestral
recubrimiento
cerámico del cuerpo
del clasificador
Cambio de sensores P Según condición
de temperatura del
eje del clasificador
Cambio de M Según condición
termocupla
Fuente: Elaboración propia
274
Teniendo las frecuencias de mantenimiento preventivo, se puede fijar el costo
anual de este, el cual se muestra en la tabla 49.
275
cromo - carbón
Cambio de Cubos de álabes 30 unidades S/.205,2 S/.6 156
cubos soporte fijos
Cambio del Sello de alta 1 unidad S/.15 965,16 S/.15 965,16
sello de alta eficiencia
eficiencia
Cambio de Junta de 1 unidad S/.6 700 S/.6 700
junta de expansión
expansión
Ordenamiento - - - -
del cableado
para
instrumentos
Relleno con Recubrimiento 8 KITS S/.1 790 S/.14 320
recubrimiento PNEU WEAR
cerámico del LOCTITE HIGH
cuerpo del TEMPERATURE
clasificador LOC 983.8
Total S/.178 325,23
Fuente: La empresa
276
de la fuente
Verificación del funcionamiento M Diario
del ventilador de refrigeración
Prueba de aislamiento del motor P Semestral
Bomba Monitoreo de temperatura de la M Diario
bomba
Verificación de estado de pernos M Diario
de anclaje y base
Verificación de la presencia de M Diario
ruidos extraños e identificación
de la fuente
Verificación de fugas de aceite M Diario
Verificación del filtro de aceite M Diario
Verificación del nivel y color del M Diario
aceite en mirilla
Registro de la presión de marcha M Diario
Registro de la contrapresión
Registro de la presión de las M Diario
bombas
Verificación de la limpieza del M Diario
respiradero del tanque
Verificación de la limpieza de las P Semestral
válvulas
Verificación del funcionamiento P Semestral
de las bobinas de las válvulas
Tuberías Verificación de fugas de aceite M Diario
Acumuladores Verificación de fugas de aceite M Diario
de nitrógeno Registro de la presión de P Semanal
nitrógeno de los acumuladores
Fuente: Elaboración propia
277
Conforme con las tareas de mantenimiento predictivo, se verificó en el listado de
averías del año 2015 (anexo 47), que no se han presentado fallas en el sistema
hidráulico de los rodillos máster.
278
uno de los sistemas clave para el funcionamiento del molino vertical, por lo que
se va a considerar el costo que representa su mantenimiento.
Los datos usados para describir la situación actual se encuentran en la tabla 26 y los
datos usados para describir la situación propuesta se encuentran en el anexo 41.
E= (B*A*C) /D*1000
(56)
279
Tabla 53: Cálculo del consumo de aditivo de molienda de la propuesta
A Flujo de aditivo 101,2 litros/h
B Densidad del aditivo 1,23 kg/litro
C Dilución 50%
D Productividad 177 TM/h
E Consumo de aditivo 351,63 gr/TM
Fuente: La empresa
280
Tabla 55: Utilidad obtenida al incrementar la productividad
Ítem Descripción Actual Propuesta Diferencia Fuente
A Productividad 164 TM/h 177 TM/h 13 TM/h Tabla 54
B Horas 24 24
C Producción diaria 3936 TM 4248 TM 312 TM A*B
D Yeso 196,8 TM 212,4 TM 15,6 TM Anexo 11
E Puzolana 787,2 TM 849,6 TM 62,4 TM Anexo 11
F Clinker 2952 TM 3186 TM 234 TM Anexo 11
G Energía 34 KW-h/TM 30 KW-h/TM -4 KW-h/TM Tabla 54
H Aditivo 369 gr/TM 352 gr/TM -17 gr/ TM Tabla 54
I Costo de clinker S/.442.800 S/.477.900 S/.35.100 Anexo 12
J Costo de puzolana S/.7.872 S/.8.496 S/.624 Anexo 12
K Costo del yeso S/.7.872 S/.8.496 S/.624 Anexo 12
L Costo de aditivo S/.3.631 S/.3.738 S/.107 Anexo 12
M Costo de energía S/.40.147 S/.38.232 -S/.1.915 Anexo 12
N Costo total S/.502.322 S/.536.862 S/.34.540 I+J+K+L+M
O Ingresos S/.1.852.235 S/.1.999.059 S/.146.824 Anexo 12
P Utilidad S/.1.349.913 S/.1.462.197 S/.112.283 O-N
Q Costo anual S/.24.111.464 S/.25.769.388 S/.1.657.924 N*4*12
R Ingreso anual S/.88.907.294 S/.95.954.824 S/.7.047.529 O*4*12
S Utilidad anual S/.64.795.830 S/.70.185.436 S/.5.389.606 R-Q
Fuente: Elaboración propia en base a información aproximada de la empresa
281
CAPÍTULO VI
282
EVALUACIÓN DEL MÉTODO
283
Sistema de producción: Según lo investigado es más común utilizar el Seis
Sigma en sistemas de producción por lote que en sistemas de producción
continuos.
Requisitos: Para ejecutar algunas herramientas como el análisis de la varianza
los datos deben de cumplir primero ciertos requisitos estadísticos.
Máxima producción: No se logró llegar a la producción nominal del molino de
180 TM/h, se llegó a 177 TM/h.
Según Barra (2008), el CAPM es una teoría que busca estimar los precios de los
activos sujetos a riesgo y, para ello, establece una relación entre la tasa de
rendimiento esperada de un activo y el riesgo que tiene el mismo.
Según el CAPM, la fórmula del costo del capital propio es: (Barra 2008).
Ke = rf + β(rm – rf)
(57)
Dónde:
284
Tabla 56: Costo de oportunidad de capital
Indicador Símbolo Valor Fuente
Tasa libre de riesgo rf 5,8% MEF
Beta de la acción o activo β 1,31% Damodaran
Uso en la práctica (Rendimiento
Prima de riesgo del mercado (rm-rf) 6% histórico del IGBVL - Tasa libre de
riesgo)
Costo de capital propio Ke 13,69%
Fuente: Elaboración propia
Los datos que serán usados para el cálculo del VAN se presentan en la tabla 57.
285
El cálculo del VAN de la situación actual de operación del molino vertical en la producción de cemento tipo HE y de la
propuesta de mejora se muestra en la tabla 58:
Se puede observar que el VAN es mayor con la propuesta de mejora que se ha planteado utilizando el método Seis
Sigma, por lo tanto, su puesta en marcha es recomendable y factible.
Este método es un aporte científico importante ya que no hay muchos estudios similares en empresas cementeras ni
en sistemas de producción continuos. Asimismo, las mejoras planteadas en esta tesis son factibles en el entorno práctico
de la planta de cemento.
286
CONCLUSIONES
287
RECOMENDACIONES
288
BIBLIOGRAFÍA
JUNG, Otto.
2000 "Protección contra el desgaste en los molinos de cubeta y rodillos". En:
ZKG INTERNATIONAL. Año 2000, volumen 53, N°5, pp. 252-260.
REICHARDT, York.
2010 "The new PFEIFFER roller mill MVR: reliable grinding technology for high
throughput rates". En: ZKG INTERNATIONAL. Año 2010, N°11, pp. 40-45.
289
SALAMANCA, Rodrigo. (2000). Los cementos adicionados. Ciencia e
ingeniería Neogranadina. Año 2000, volumen 9, N°1, pp. 77-83.
Fecha de consulta: 14-05-2015.
Recuperado de: https://dialnet.unirioja.es/servlet/articulo?codigo=5313963
Instituto español del cemento y sus aplicaciones. 2015. Historia del cemento.
Recuperado de https://www.ieca.es/reportaje.asp?id_rep=5.
Fecha de consulta: 31-05-2015.
290
Massachusetts Institute of technology (MIT). 2012. Six sigma basics V7.6.
Recuperado de: https://ocw.mit.edu/resources/res-16-001-lean-enterprise-en-espanol-
january-iap-2012/material-de-lectura/MITRES_16_001IAP12_3-6Sgma.pdf
Fecha de consulta: 02-02-2017.
291
RENK AG. 2000. Operating instructions.
BUSTOS, Braulio.
2016 "Análisis de la varianza". En: Control estadístico de la calidad usando
MINITAB. Arequipa. Diciembre.
CABALLERO, Ángel.
2009 "Sesión sobre innovación y desarrollo tecnológico en procesos". En: VII
Coloquios de directores y técnicos de fábricas de cemento. Málaga. Diciembre.
292
GONZÁLES, Manuel.
1997 "La calidad y los métodos instrumentales en la industria del cemento".
En: Química y tecnología del cemento. Lima. Octubre.
HERRERA, Luis.
2012 "FSLmidth. Entrenamiento de Operadores de Sala de Control". En:
Curso de capacitación. Arequipa. Abril.
MISCHORR, Frank.
2010 "Process training LM 56 2 + 2". En: Process / Mill operation training.
Arequipa. Abril.
SÁEZ, Antonio.
2012 "Apuntes de estadística para ingenieros". En: Universidad de Jaén,
departamento de estadística e investigación operativa. Jaén. Junio.
293
SANTIVAÑEZ, Miguel.
2014 "Optimización y rediseño de procesos II". En: Diplomado en gestión de
procesos y calidad. Arequipa. Julio.
Libros
DUDA, Walter.
1977 "Manual tecnológico del cemento". En: Sarabia, Antonio (traductor).
Primera edición. Barcelona: Editores técnicos asociados S.A.
LABAHN, Otto.
1966 "Prontuario del cemento". En: Margarit, Adrián (traductor). Tercera
edición. Barcelona: Editores técnicos asociados S.A.
294
MONTGOMERY, Douglas.
2004 "Diseño y análisis de experimentos". Segunda edición. México, D.F:
Editorial LIMUSA S.A. Grupo Noriega Editores.
BLANCO, Francisco.
S.f. "Lección 14: Cementos, Molienda de Crudo y Molinos de Rodillos". En:
Universidad de Oviedo. Fecha de consulta: 03-12-2010.
Recuperado de:
http://www6.uniovi.es/usr/fblanco/Leccion14.CEMENTOS.MoliendaCrudo.INTRODUCCION.pdf
DAMODARAN, Aswath.
2017 "Beta, Unlevered beta and other risk measures". Fecha de consulta: 01-
11-2017.
Recuperado de: http://www.damodaran.com
295
DÍAZ, José.
2005 "Estadística con programación". En: math.uprag.edu. Fecha de consulta:
16-01-2017.
Recuperado de: http://math.uprag.edu/residuales1.pdf
DOMENECH, José.
S.f "Diagrama de Pareto". En: http://www.jomaneliga.es/. Fecha de consulta:
25-01-2017.
Recuperado de:
http://www.jomaneliga.es/PDF/Administrativo/Calidad/Diagrama_de_Pareto.pdf
ECHE, David.
2016 "Pruebas Paramétricas y No Paramétricas para la comprobación de
hipótesis". En: www.wordpress.com
Fecha de consulta: 28-07-2017.
Recuperado de: https://enviromigration.files.wordpress.com/2016/04/pruebas-
paramc3a9tricas-y-no-parametricas.pdf
FLORES, Raúl.
2015 "Prueba de homogeneidad de varianza". En: http://www.slideshare.net/.
Fecha de consulta: 24-01-2017.
Recuperado de: http://www.slideshare.net/rfmflores/prueba-de-homogeneidad-de-
varianza
HERNÁNDEZ, H.
2005 "Cartas de control". En: http://www.icicm.com/. Fecha de consulta: 15-
02-2016.
Recuperado de: www.icicm.com/files/Cartas_de_Control.doc
296
RAEBER, Roger; Ulf WELLER y Rocco AMATO.
S.f. "A new gearbox generation for vertical roller mills". En: Artec Machine
Systems. Fecha de consulta: 14-05-2015.
Recuperado de:https://www.artec-machine.com/wp-content/docs/3-stage-
gearbox_vertical-roller-mills.pdf.
SALGADO, Dagoberto.
S.f. "Curso taller de aplicación de MINITAB básico. En:
http://www.estadisticacondago.com/. Fecha de consulta: 10-01-2017.
Recuperado de:
http://www.estadisticacondago.com/images/estadistica_inferencial/Curso%20Taller%20Minit
ab%20Basico.pdf
SALGADO, Dagoberto.
S.f. "Pruebas de normalidad". En: http://www.estadisticacondago.com/. Fecha de
consulta: 10-01-2017.
Recuperado de:
http://www.estadisticacondago.com/images/estadistica_inferencial/pruebas%20de%20norma
lidad.pdf
ALCÁNTARA, Juan.
2008 "Diseño práctico de un molino de bolas". Tesis de grado. Instituto
politécnico nacional. México, D.F.
297
ÁVILA, Desireé.
2006 "Modelo para la implementación y aplicación de seis sigma, en base a
una industria de acero". Tesis de grado. Universidad de San Carlos de
Guatemala. Guatemala.
CALDERÓN, Emilsen.
2009 "Mejora de procesos en una imprenta que realiza trabajos de impresión
OFFSET basados en la empleando six sigma". Tesis de grado. Pontificia
Universidad Católica del Perú. Lima.
CARDONA, John.
2013 "Modelo para la implementación de técnicas lean manufacturing en
empresas editoriales". Tesis de maestría. Universidad Nacional de Colombia.
Manizales.
PRIETO, Percy.
2008 "Uso de la metodología six sigma como referencia para la optimización
de una área de mantenimiento de planta". Tesis de grado. Universidad
Nacional Mayor de San Marcos. Lima.
SALVADOR, Gerardo.
2009 "Medición del ruido en la línea de transmisión eléctrica generado por
electrodomésticos, para aplicaciones de PLC". Tesis de grado. Universidad de
las Américas Puebla. Puebla.
298
SÁNCHEZ, Eduardo.
2005 "Seis sigma, filosofía de gestión de la calidad: Estudio teórico y su
posible aplicación en el Perú". Tesis de grado. Universidad de Piura. Piura.
VÁZQUEZ, Jaime.
2005 "Filosofía 6 sigma: Una metodología para mejorar la calidad de
productos y servicios en el sector productivo". Tesis de grado. Instituto
politécnico nacional. México, D.F.
299
GLOSARIO DE TÉRMINOS
300
Reductor de velocidad: Mecanismos destinados para disminuir la
velocidad angular en los accionamientos desde el motor a la máquina de
trabajo.
Varianza: Media de las desviaciones estándar al cuadrado.
301
ANEXOS
302
Anexo 3: Distribución Chi cuadrado
303
Anexo 4: Valores críticos de la distribución "t" student
304
Anexo 5: Constantes para gráficos de control
305
Anexo 6: Producción de cemento del mes 1
TM TM TM h TM TM TM h
1554,300 140,900 1132,500 15,72 352,900 26,500 72,300 2,67
721,400 63,800 490,700 7,18
762,800 67,200 505,800 7,85 1108,300 84,500 260,720 8,93
885,000 86,700 645,000 9,08 1006,300 77,400 227,900 8,12
263,700 13,800 0,000 1,82 650,100 46,100 139,800 5,00
281,300 19,600 61,600 2,20
1004,400 96,900 726,100 10,18 660,000 45,000 144,400 5,13
2198,400 193,900 1565,000 21,82
2401,700 215,900 1774,360 24,00
1435,700 127,100 881,900 13,75 1269,700 91,900 283,000 9,82
2142,300 201,800 1585,000 21,75 297,700 22,400 66,000 2,25
2373,500 228,500 1770,000 24,00
502,700 40,500 231,900 4,25 954,000 58,600 201,300 7,70
236,700 22,600 172,600 2,50 329,600 20,400 77,200 2,50
1342,300 128,600 963,000 13,90
1501,183 145,700 1076,400 15,17 1206,019 94,535 280,450 8,83
1376,500 131,900 1011,600 14,90 1008,000 80,300 253,100 8,60
2320,000 214,200 1663,200 24,00
1414,200 125,500 955,300 14,27
1175,600 113,000 862,300 12,00 1222,400 97,500 306,300 10,83
2009,300 195,400 1485,300 20,58
1478,200 143,500 1081,700 15,08 1066,700 83,500 272,100 8,92
2115,200 200,700 1544,800 21,50 299,600 24,200 79,400 2,50
1574,700 149,600 1153,400 16,00
1409,200 133,400 965,100 14,73 1087,300 85,700 256,600 9,27
2177,000 207,900 1591,600 23,40
1625,800 146,800 1039,900 16,65
1508,900 138,200 1097,700 16,03 853,500 58,700 186,800 6,95
2294,40 205,10 1651,40 24,00
2319,50 210,30 1676,00 24,00
Fuente: La empresa
306
Anexo 7: Producción de cemento en el mes 2
TM TM TM h TM TM TM h
2345,000 212,100 1720,000 23,73
2391,500 226,100 1707,000 24,00
1833,000 172,200 1305,000 18,40 708,400 53,900 149,500 5,60
633,500 47,800 142,800 5,00
692,600 66,000 507,400 7,03 2022,500 152,800 459,300 15,60
2335,000 227,200 1734,800 23,87
2356,400 228,300 1738,100 24,00
1408,100 125,700 856,300 13,48
1039,900 96,300 794,100 10,89 986,200 63,600 202,800 7,39
2350,000 194,700 1700,000 23,46
2357,800 215,600 1737,600 24,00
1764,900 159,300 1260,900 17,75
1614,200 146,200 1162,700 16,40
2234,600 200,200 1537,700 22,17 227,500 17,700 50,200 1,83
75,200 8,300 54,800 0,75 509,500 40,000 117,700 4,25
1447,800 137,100 787,400 14,55
Fuente: La empresa
307
Anexo 8: Producción de cemento en el mes 3
TM TM TM h TM TM TM h
674,000 64,300 427,390 6,55 1387,200 103,800 252,140 11,33
776,500 71,200 514,730 7,55
1992,200 170,200 1159,640 18,82
866,300 55,800 185,400 7,00
643,600 58,000 399,270 6,25 1711,400 116,700 351,970 13,83
2475,100 214,100 1556,260 24,00
1894,400 168,300 1204,000 18,62 612,300 44,400 123,680 5,00
1204,300 122,100 812,270 12,38 1453,800 114,500 295,060 11,43
2258,100 220,000 1521,200 22,48
1593,800 148,200 899,410 15,35 825,400 66,100 146,830 6,63
182,700 21,800 129,310 1,92 2723,000 224,980 512,980 21,95
2401,700 245,500 1633,760 24,00
2086,000 208,500 1248,640 20,48 93,400 7,400 19,010 0,75
1443,200 151,800 977,600 14,42 1216,500 100,300 227,200 9,58
2060,400 250,900 1468,300 21,35
605,800 72,500 433,700 6,30
108,500 8,300 22,200 0,90 2410,500 208,900 484,800 19,10
1920,100 184,100 1305,500 19,00 629,900 53,900 122,900 5,00
1079,000 95,100 724,200 10,60 1738,100 130,100 360,700 13,40
2254,300 196,600 1535,100 22,15 239,900 16,400 49,200 1,85
361,800 30,700 178,900 3,30 2512,800 196,600 597,200 20,30
2076,900 193,700 1419,800 20,70 350,000 28,000 83,000 2,90
2252,200 195,600 1462,600 22,00 255,900 18,800 52,300 2,00
754,900 67,400 519,400 7,58 1509,600 113,800 281,800 11,50
2357,300 219,500 1598,000 23,67
1158,600 103,700 719,400 11,42
2427,700 196,600 1666,600 24,00
2518,700 199,300 1603,500 24,00
2246,600 202,700 1365,100 21,35 339,700 21,500 63,700 2,58
534,600 44,600 314,600 5,07 1601,800 108,600 312,600 12,12
939,200 64,800 409,300 8,05 2045,300 144,700 309,200 15,55
Fuente: La empresa
308
Anexo 9: Producción de cemento en el mes 4
TM TM TM h TM TM TM h
260,800 23,900 172,400 2,65 812,900 62,200 161,700 6,18
2421,100 234,600 1596,900 23,82
1783,700 171,100 1146,600 17,50 815,600 64,300 158,500 6,33
200,400 19,100 133,700 1,95 2171,100 174,000 461,000 16,93
2439,500 228,000 1578,500 24,00
530,500 43,800 224,800 5,10 252,500 16,400 46,300 2,10
1700,400 160,800 1079,800 16,47 763,300 51,600 143,600 5,92
2538,000 221,600 1562,300 24,00
2539,300 217,100 1519,200 23,85
1764,600 146,800 1125,700 16,70
1053,100 87,300 561,000 9,60 782,600 58,000 125,300 5,90
239,800 23,600 141,900 2,35 2078,600 148,700 276,600 15,80
555,700 50,700 299,800 5,10
1650,500 154,900 1039,000 16,00
1735,500 172,600 1177,800 17,22
160,100 11,700 25,400 1,427 1483,100 98,200 282,400 12,20
1337,300 129,100 938,000 13,25
1747,400 168,600 1255,000 17,53
2391,200 224,600 1703,200 23,87
1793,100 168,000 1269,700 17,80
894,300 80,300 602,600 8,83 1092,700 73,300 237,000 8,82
1324,000 97,000 279,000 10,70
1905,400 178,300 1273,500 18,62
2349,900 220,900 1575,900 22,88
2477,800 219,300 1659,400 24,00
154,400 12,300 62,800 1,37 2748,700 216,800 609,200 22,17
1739,300 174,600 1253,600 17,50 803,600 64,800 177,900 6,50
2280,400 228,500 1650,400 23,17
2364,000 233,800 1684,300 24,00
2364,300 237,800 1721,800 24,00
Fuente: La empresa
309
Anexo 10: Energía y aditivo consumidos
Descripción Valor
Clinker 150 S/. TM
Puzolana 10 S/. TM
Yeso 40 S/. TM
Energía 0,3 S/. KW-h
Aditivo 2,5 S/. Kg
Precio cemento HE 471 S/. TM
Precio cemento 1P 447 S/. TM
Fuente: La empresa
310
Anexo 13: Problemas en la producción del cemento tipo HE
311
Anexo 15: Parámetros de calidad del clinker y productividad del molino
312
Anexo 16: Productividad a una temperatura promedio de 42,05°C
313
Anexo 17: Productividad a una temperatura promedio de 131,53°C
314
Anexo 18: Productividad a una temperatura promedio de 99,93°C
315
Anexo 19: Productividad a un flujo de gas promedio de 499954 m3/h
316
Anexo 20: Productividad a un flujo de gas promedio de 472876 m3/h
317
Anexo 21: Productividad a un flujo de gas promedio de 484060 m3/h
318
Anexo 22: Productividad a un flujo de agua promedio de 1500 litros/h
319
Anexo 23: Productividad a un flujo de agua promedio de 1100 litros/h
320
Anexo 24: Productividad a un flujo de agua promedio de 1812 litros/h
321
Anexo 25: Productividad a una velocidad promedio de 103 rpm
322
Anexo 26: Productividad a una velocidad promedio de 97 rpm
323
Anexo 27: Productividad a una velocidad promedio de 100 rpm
324
Anexo 28: Productividad a una presión promedio de 102 BAR
325
Anexo 29: Productividad a una presión promedio de 95 BAR
326
Anexo 30: Productividad a una presión promedio de 97 BAR
327
Anexo 31: Plano del sistema de suministro de clinker
Fuente: La empresa
328
Anexo 32: Diagrama de flujo del sistema de extracción de clinker
Fuente: La empresa
329
Anexo 33: Plano del alimentador vibratorio de clinker
Fuente: La empresa
330
Anexo 34: Productividad a una temperatura promedio de 94°C
331
Anexo 35: Productividad a una temperatura promedio de 111°C
332
Anexo 36: Productividad a una temperatura promedio de 113°C
333
Anexo 37: Experimento considerando 1100 litros/h, 100 rpm y 97 BAR
334
Anexo 38: Experimento realizado considerando 1500 litros/h, 100 rpm y 97 BAR
335
Anexo 39: Experimento considerando 1100 litros/h, 103 rpm y 97 BAR
336
Anexo 40: Experimento considerando 1500 litros/h, 103 rpm y 97 BAR
337
Anexo 41: Experimento considerando 1100 litros/h, 100 rpm y 102 BAR
338
Anexo 42: Experimento considerando 1500 litros/h, 100 rpm y 102 BAR
339
Anexo 43: Experimento considerando 1100 litros/h, 103 rpm y 102 BAR
340
Anexo 44: Experimento considerando 1500 litros/h, 103 rpm y 102 BAR
341
Anexo 45: Averías de los equipos del transporte de materias primas
342
14/05/2015 10750603 SEPARADOR MAGNÉTICO P1-REPONER BANDA
22/05/2015 10754454 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE TARJETA DE SECUENCIADOR ELECTR / POLUCIO
22/05/2015 10754455 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE TARJETA DE SECUENCIADOR ELECTR / POLUCIO
22/05/2015 10754372 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE TARJETA DE SECUENCIADOR ELECTR / POLUCIO
22/05/2015 10754371 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE TARJETA DE SECUENCIADOR ELECTR / POLUCIO
04/06/2015 10761029 ELEVADOR DE CANGILONES P1-MTTO GUIAS LATERALES DEL CONTRAPESO
04/06/2015 10761030 ELEVADOR DE CANGILONES P1-PARCHAR AGUJEROS DE CANGILONES
13/06/2015 10765839 VÁLVULA ROTATORIA FILTRO DE DESPOLVORIZA M-1 CAMBIO DE RUEDA CELULAR
13/06/2015 10765838 SEPARADOR MAGNÉTICO M-1 CAMBIO DE SELECTOR LOCAL
15/06/2015 10766918 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE SISTEMA MECÁNICO DE LIMPIEZA / ROTURA DE
15/06/2015 10766919 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE SISTEMA MECÁNICO DE LIMPIEZA / ROTURA DE
15/06/2015 10766920 ELEVADOR DE CANGILONES ESTRUCTURA / FUGA DE MATERIAL / DESGASTE
15/06/2015 10766921 VÁLVULA ROTATORIA FILTRO DE DESPOLVORIZA CARCAZA / FUGA DE MATERIAL / DESGASTE DE
15/06/2015 10766922 VÁLVULA ROTATORIA FILTRO DE DESPOLVORIZA CARCAZA / FUGA DE MATERIAL / DESGASTE DE
18/06/2015 10768657 FILTRO DE DESPOLVORIZACIÓN P-1 PARCHADO DE AGUJERO
19/06/2015 10769489 ELEVADOR DE CANGILONES P1-MTTO GUIAS LATERALES DEL CONTRAPESO
21/06/2015 10770120 SEPARADOR MAGNÉTICO P1-CAMBIO DE RODAMIENTO EN CHUMACERA
23/06/2015 10771143 FAJA TRANSPORTADORA CLINKER P1-TEMPLADO DE CADENA
26/06/2015 10772784 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-MODIFICAR CHUTE DE DESCARGA
27/06/2015 10773294 CENTRO DE CONTROL DE MOTORES MOLINO PEINADO DE CABLES
02/07/2015 10775769 ELEVADOR DE CANGILONES P1-CUADRANTE CON DESGASTE
08/07/2015 10778666 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-MODIFICAR GUARDA DE ACCIONAMIENTO
08/07/2015 10778665 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1--INSTALAR LIMPIADOR SECUNDARIO
08/07/2015 10778669 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-LIMPIEZA DE BASTIDOR Y PASADIZOS
08/07/2015 10778672 FAJA TRANSPORTADORA ASCENDENTE N° 1 p1-CAMBIO TEMPLADORES TAMBOR DE COLA
08/07/2015 10778687 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO DE POLINES DE IMPACTO
08/07/2015 10778671 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1- fabricación de techo protector
08/07/2015 10778709 FAJA TRANSPORTADORA ASCENDENTE N° 1 p1-modificar chute descarga
08/07/2015 10778690 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO DE TAMBORES EN BANDA.
10/07/2015 10779887 VENTILADOR FILTRO DE DESPOLVORIZACIÓN p1-rectificar poleas de accionamiento.
10/07/2015 10779888 VÁLVULA ROTATORIA FILTRO DE DESPOLVORIZA p1-cambio de rueda celular
17/07/2015 10783867 SEPARADOR MAGNÉTICO P1-DESPRENDIMIENTO DE EMPALME
21/07/2015 10785808 ELEVADOR DE CANGILONES P1-PARCHAR HUECOS EN ELEVADOR
23/07/2015 10787006 ELEVADOR DE CANGILONES P1-AGUJEROS EN CARCASA
23/07/2015 10787007 ELEVADOR DE CANGILONES P1-REPONER GUARDA DEL ACOPLE
23/07/2015 10787005 FILTRO DE DESPOLVORIZACIÓN P1-MTTO A SISTEMA DE LIMPIEZA
24/07/2015 10787300 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-LIMPIEZA BASE TAMBOR CONDUCIDO
24/07/2015 10787304 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-FABRICACION Y COLOCACION TECHO
24/07/2015 10787299 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO LUBRICADORES AUTOMATICOS
24/07/2015 10787654 FAJA TRANSPORTADORA ASCENDENTE N° 1 P-1 ORDEN EN CABLES DE ALIMENTACION
24/07/2015 10787656 FAJA TRANSPORTADORA ASCENDENTE N° 1 P-1 PEINADO DE CABLES/LIMPIEZA DE CANALE
343
24/07/2015 10787615 FILTRO DE DESPOLVORIZACIÓN P-1 MANTENIMIENTO A SELECTOR LOCAL
24/07/2015 10787613 FILTRO DE DESPOLVORIZACIÓN P-1 REPONER GUARDA EN RUEDA CELULAR
24/07/2015 10787302 SEPARADOR MAGNÉTICO P1-REFUERZO DE EMPALME BANDA
25/07/2015 10788065 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE P-1 CAMBIO DE GUIAS E DUCTO DE SUCCION
25/07/2015 10788069 FAJA TRANSPORTADORA PUZOLANA P-1 IMPLEMENTACION DE GUARDA
25/07/2015 10788072 FAJA TRANSPORTADORA PUZOLANA P-1 MODIFICACION EN GUARDA
25/07/2015 10788086 FAJA TRANSPORTADORA PUZOLANA P-1 FIJACON DE TUBERIA
25/07/2015 10788085 FAJA TRANSPORTADORA PUZOLANA P-1 MTTO A ILUMINACION EN TUNEL
25/07/2015 10788084 FAJA TRANSPORTADORA PUZOLANA P-1 IMPLEMENTACIONDE GUIA POSTERIOR
25/07/2015 10788105 ELEVADOR DE CANGILONES sistema de seguridad (alarma) inoperativo
25/07/2015 10788104 ELEVADOR DE CANGILONES P-1 MONTAJE DE GUARDA EN ACOPLAMIENTO
31/07/2015 10791102 FAJA TRANSPORTADORA ASCENDENTE N° 1 P-1 ALINEAR RUEDA CELULAR
03/08/2015 10792491 ELEVADOR DE CANGILONES P1-PLACHA DE DESCARGA GASTADA
04/08/2015 10793134 DESCARGADOR PUZOLANA 1 Tolva con huecos
06/08/2015 10794537 FILTRO DE DESPOLVORIZACIÓN P1-DUCTO OBSTRUIDO
18/08/2015 10803945 FAJA TRANSPORTADORA PUZOLANA P1-LUBRICACION DE CADENAS TRANSMISION
18/08/2015 10803946 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-LUBRICACION DE CADENAS TRANSMISION
18/08/2015 10803944 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO TAMBORES DESVIO A CONTRAPESO
18/08/2015 10803951 FILTRO DE DESPOLVORIZACIÓN P1-MTTO FILTRO DE MANGAS
18/08/2015 10803948 SEPARADOR MAGNÉTICO P1-APERTURAR VENTANA INSPECCION
24/08/2015 10809585 FAJA TRANSPORTADORA CLINKER P1-CAMBIO POLIN DE CARGA LATERAL
31/08/2015 10814814 DESCARGADOR PUZOLANA 1 P1-AGUJEROS EN CHUTE DE CARGA
02/09/2015 10817605 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-GUIA DE CONTRAPESO DAÑADA
02/09/2015 10817609 ELEVADOR DE CANGILONES P1-AGUJEROS EN CARCAZA
02/09/2015 10817608 VÁLVULA DE TRES VÍAS P1-AGUJEROS EN DUCTO
02/09/2015 10817433 DESCARGADOR GRAVIMETRICO #1 EN FAJA 2007 P1-COLOCAR FALDON
03/09/2015 10818255 ELEVADOR DE CANGILONES P1-MANTENIMIENTO GUIAS DEL CONTRAPESO
03/09/2015 10818256 ELEVADOR DE CANGILONES P1-CAMBIO DE CANGILONES DE ELEVADOR
13/09/2015 10825678 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO DE POLINES AUTOALINEANTES
13/09/2015 10825679 COMPUERTA DE 02 VIAS P1-HERMETIZAR COMPUERTA
15/09/2015 10827005 ELEVADOR DE CANGILONES P1-RECORTAR UN TRAMO DE CADENA.
18/09/2015 10829157 FAJA TRANSPORTADORA PUZOLANA P1-REPARAR AGUJEROS EN BANDA
18/09/2015 10829158 SEPARADOR MAGNÉTICO P1-CAMBIO RODAJES TAMBOR TENSADOR.
04/10/2015 10841237 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1- REPONER LIMPIADOR EN V
05/10/2015 10841540 FAJA TRANSPORTADORA ASCENDENTE N° 1 CAMBIO DE LIMPIADOR EN "V"
15/10/2015 10849516 FAJA TRANSPORTADORA PUZOLANA P1-REFORZAR COVER DE BANDA
15/10/2015 10849518 FAJA TRANSPORTADORA PUZOLANA P1-COLOCAR LUBRICADORES AUTOMATICOS
15/10/2015 10849537 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-REFORZAR EMPALME DE BANDA
15/10/2015 10849534 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO DE POLINES
15/10/2015 10849521 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-LIMPIEZA BASE TAMBOR CONDUCIDO
15/10/2015 10849540 ELEVADOR DE CANGILONES P1-PARCHAR AGUJEROS EN CARCASA
344
17/10/2015 10850475 FAJA TRANSPORTADORA PUZOLANA P1-Reforzar deflector de descarga
23/10/2015 10855349 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-Colocar guarda de proteccion
28/10/2015 10859022 FAJA TRANSPORTADORA PUZOLANA P1-DESPRENDIMIENTO DE EMPALME
28/10/2015 10859104 FAJA TRANSPORTADORA PUZOLANA P1-CORTES LONGITUDINALES
28/10/2015 10859023 FAJA TRANSPORTADORA PUZOLANA P1-PLANCHAS DETERIORADAS
28/10/2015 10859105 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIAR POLINES "AGUJEROS"
28/10/2015 10859106 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-HABILITAR LUBRICADORES AUTOMATICOS
28/10/2015 10859107 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-HABILITAR ELEMENTOS LIMPIADORES
05/11/2015 10865195 ELEVADOR DE CANGILONES P1-PROGRAMAR CAMBIO PILLOW BLOCKS
05/11/2015 10865194 ELEVADOR DE CANGILONES P1-PROGRAMAR CAMBIO DE CANGILONES
06/11/2015 10865618 ELEVADOR DE CANGILONES P1-PARCHADO DE AGUJEROS EN CARCASA
12/11/2015 10870633 FAJA TRANSPORTADORA PUZOLANA P1-REFORZAR BANDA TRANSPORTADORA
12/11/2015 10870685 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO DE LUBRICADORES AUTOMATICOS
12/11/2015 10870684 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-REFORZAR PARCHE DE EMPALME DE BANDA
16/11/2015 10872696 FAJA TRANSPORTADORA PUZOLANA P1-CAMBIO DE GUIAS LATERALES
19/11/2015 10875799 FAJA TRANSPORTADORA PUZOLANA P-1 MODIFICACION EN GUARDA
19/11/2015 10875798 FAJA TRANSPORTADORA PUZOLANA P-1 IMPLEMENTACION DE GUARDA
19/11/2015 10875772 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE P1-CAMBIO JUNTA EXPANSION
19/11/2015 10875804 ELEVADOR DE CANGILONES P-1 MONTAJE DE GUARDA EN ACOPLAMIENTO
24/11/2015 10879465 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-Cambiar limpiador primario
24/11/2015 10879466 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-Colocar limpiador secundario
29/11/2015 10883678 FAJA TRANSPORTADORA ASCENDENTE N° 1 p1-reforzar empalme
02/12/2015 10886219 FAJA TRANSPORTADORA PUZOLANA P1-REFORZAR PARCHE SEPARADOR MAGNETICO
02/12/2015 10886218 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO DE ESTACIÓN DE POLINES D CARGA
02/12/2015 10886216 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-CAMBIO DE ESTACIONES AUTOALINEANTES
02/12/2015 10886215 ELEVADOR DE CANGILONES P1-PARCHAR AGUJEROS CARCASA DE ELEVADOR
02/12/2015 10886183 VENTILADOR FILTRO DE DESPOLVORIZACIÓN P1-CAMBIO DE CORREAS DE TRANSMISIÓN
04/12/2015 10888437 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE P1-REVISAR FILTRO COMPACTO
04/12/2015 10888190 FAJA TRANSPORTADORA ASCENDENTE N° 1 p1-retenes dañados en chumaceras
04/12/2015 10887615 FAJA TRANSPORTADORA 300 T/H P1-Desprendimiento de empalme
09/12/2015 10891422 FAJA TRANSPORTADORA ASCENDENTE N° 1 FAJA DE TRANSPORTE / ROTURA EN EMPALME /
10/12/2015 10892285 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE CUERPO DEL FILTRO / FUGA DE MATERIAL POR
10/12/2015 10892286 ELEVADOR DE CANGILONES ESTRUCTURA / FISURA DE CARCAZA / DESGAST
13/12/2015 10894505 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-SOPORTE EN ESTACION DE POLINES ROTO
19/12/2015 10900325 ELEVADOR DE CANGILONES P1-NIVEL DE BOTA AVERIADO
21/12/2015 10901077 DESCARGADOR PUZOLANA 1 P1- CAMBIO DE COMPUERTA POR DESGASTE
21/12/2015 10901407 ELEVADOR DE CANGILONES P1-AGUJERO EN CUERPO DEL ELEVADOR
23/12/2015 10902767 FAJA TRANSPORTADORA PUZOLANA P1-CORTES LONGITUDINALES
23/12/2015 10902768 FAJA TRANSPORTADORA PUZOLANA P1-PLANCHAS DETERIORADAS TOLVA ALIMENTAC
23/12/2015 10902769 FAJA TRANSPORTADORA PUZOLANA P1-CAMBIO DE LIMPIADOR PRIMARIO
23/12/2015 10902771 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-DESPRENDIMIENTO DE EMPALME
345
23/12/2015 10902772 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-DETERIORO EN BARRAS DE IMPACTO
23/12/2015 10902824 FAJA TRANSPORTADORA ASCENDENTE N° 1 P1-POLINES DETERIORADOS
23/12/2015 10902856 VÁLVULA DE TRES VÍAS P1-AGUJEROS EN CHUTE
26/12/2015 10904967 FILTRO COMPACTO DESPOLVORIZACIÓN TRANSFE P1-REVISAR SECUENCIA DE LIMPIEZA
Fuente: La empresa
346
15/09/2015 10827105 CLASIFICADOR DINÁMICO DEL MOLINO P1-CAMBIO EJE PORTA ALABE FIJO
02/10/2015 10840080 CLASIFICADOR DINÁMICO DEL MOLINO P1-CAMBIO DE PINES Y CUBOS
13/10/2015 10847409 CLASIFICADOR DINÁMICO DEL MOLINO P1- CAMBIO DE ACEITE REDUCTOR
17/10/2015 10850624 CLASIFICADOR DINÁMICO DEL MOLINO P1-ALABE FIJO CON SOLTURA
02/11/2015 10862687 MOTOR CLASIFICADOR P1-ESTRUCTURA TECHO MOTOR DAÑADO
05/11/2015 10865137 CLASIFICADOR DINÁMICO DEL MOLINO P1-CAMBIO DE CUBO
Fuente: La empresa
347