Catalogo de Productos Web Notifier
Catalogo de Productos Web Notifier
Catalogo de Productos Web Notifier
El NFS2-640 es ideal para aplicaciones medianas, y es fácilmente expandible vía la red inteligente de
alarma contra incendios de NOTIFIER, NOTI-FIRE-NETTM, para permitir la expansión futura del
establecimiento.
Se Adapta a Su Entorno
El NFS2-640 auto-optimiza cada uno de sus umbrales de alarma de sensor individualmente para acelerar
tiempos de respuesta y minimizar o eliminar alarmas molestas.
with blank plate, in remote mounting box. Equipped with 12 Relays for VLS.
VRT-A10 VESDA Analog Output Module. The VESDA Analog Output Module (AOM) is an interface
accessory/termination card that provides an output proportional to a digitally recorded smoke reading. The
AOM is supplied in a remote mounting box. The AOM converts the digital input from the VESDAnet detectors
into an analog output. This allows VESDA detectors to interface with existing Building Management Systems
(BMS) and Fire Alarm Panels that require an Analog signal to read a smoke level status.
VRT-J00 Display, Compact Version. With 7 Relays
VRT-K00 Display, Compact Version. Without Relays
VRT-S07 VESDA System Relay Module. Universal Network Module with 7 Programmable Relays, (Isolate, Minor Fault,
Urgent Fault, Alert, Action, Fire 1, Fire 2) The System Relay Module is a remote termination card with new
software supplied in a remote mounting box (VRT). The System Relay Module allows reporting of ANY alarm
or fault condition that appears on a VESDAnet loop regardless of the initiating zone. It allows a more cost -
effective solution for raising a warning signal when several VESDA detectors are installed on a single
VESDAnet loop and addressability is not required.
VRT-V00 Display, LaserPLUS and LaserFOCUS with a remote termination card. With 7 Relays (for VESDA LaserFOCUS)
VSR-0 Blank Plate
VSR-0000 VSR - 0000 SubRack
VSR-2200 PRE-CONFIGURED SUB RACK
VSR-2220 PRE-CONFIGURED SUB RACK
VSR-2222 PRE-CONFIGURED SUB RACK
VSR-1 Programmer with remote termination card - no relays
VSR-2 Standard display with 7 relay remote termination card
VSR-3 VESDAnet Socket
VSR-4 Scanner display with 7 relay remote termination card
VSR-5 (DRP) 7 relay remote termination card and relay processor
VSR-6 Standard display with remote termination card - no relays
VSR-7 Scanner display with remote termination card - no relays
VSR-8 Scanner display with 12 relay remote termination card
VSR-9 (DRP) 12 relay remote termination card and relay processor
VSR-J VLC VN display with 7 relays
VSR-K VLC VN display with no relays
VSR-V VLF with 7 relays
VHH-100 Hand Held Programmer, includes Leads.
VHX-0200 PC - Link HLI, Sliding Windows, RS232 Interface. The VHX - 200 does not have modem capabilities.
VHX-0300 PC - Link HLI, Open Protocol, RS232 Interface. VHX - 0300 has Peer to Peer Operations. To be used with
the VSC or VSM Software, to program VESDANET devices to the VHX -0200.
VHX-0900 PC - HLI, Modem Cable to connect PC - HLI directly to a modem. Note: This would be used in lieu of the
RS232 serial cable.
VHX-1200 Wall - Mounted HLI. Links VESDAnet with VESDA System Manager 4 (VSM4) and VESDA System Configurator
(VSC). Includes a built - in VESDAnet port and VESDAnet socket card.
VHX-1410 VESDA HIGH LEVEL INTERFACE
VHX-1420-HFS NOTIFIER VESDA HLI
VFT-15 24 VDC, Display/Programmer, TCP/IP, 15 inlets, Class A/B/C, 0.0003 to 6.1% obs/ft (0.001 to 20% obs/m)
01-E606-01 4 Channel Relay Module
01-E624 8 Channel 4-20mA Re-Transmission Module
01-E922-00 Blind plate for sub rack
01-E922-01 Mini RDU RS485 - 19” rack mount
01-E922-99 19 inch sub rack for 12 Mini RDU
01-V921-15 Remote Display for VFT-15
02-2002-01P Straight Union for Micro Bore 6mm Tube (Pack of 10)
02-3000-06 Stainless steel sampling point 6mm
02-FL01-01 Scintered EOL Filter for Micro Bore 6mm Tube
VT-TUBE-1000 1000’ Roll of 1/4” UL listed micro-bore tubing for use with the VFT-15
VT-TUBE-500 500’ Roll of 1/4” UL listed micro-bore tubing for use with the VFT-15
02-FL56 Filter Element Replacement FT Series (Fine) Black
02-FL53 Filter Element pack of 10 (Course) 20 ppi black
VRE-001 Single Blanking Plate
VRE-002 Double Blanking Plate
VRE-100 Enclosure
VSW-100 VESDA System Configurator (VSC) is the field management software program to support the VESDA smoke
detector range of products (including all VESDSAnet devices and VESDA LaserFOCUS). It provides an
improved and flexible approach to managing detectors in the field. Replaces V - Config Pro Software.
VSW-202 ASPIRE2 is a pipe network design verification tool that supports both new and existing smoke detection
products. It provides a new benchmark in usability and verification flexibility for VESDA smoke detector
products.
VSW-206 Central Site License – Primary PC
VSW-216 Central Site License – Secondary PC
VSW-226 VSM3 Upgrade – Primary PC
VSW-346 VESDAnet Network Connection – 1 required per monitored VESDAnet
VSW-356 VESDAnet Detector Connection – 1 required per monitored detector.
VSW-356-ECO VESDA ECO DETECTOR NETWORK CONNECTION– 1 required per monitored detector.
VSW-366 VESDATalk/VESDALink Detector Connections – VESDAtalk for use with direct connect VLS 250 & 500
detectors. VESDALink for use with direct connect VLC - 500 detectors.
VSW-502 Text to Speech – English
VSW-508 Text to Speech – Spanish
VSW-600 VESDA REMOTE NOTIFICATION EMAIL/SMS
ECO-D-B-11 HYDROGEN (H2) 0-100% LEL
ECO-D-B-12 Methane (CH4) 0-100% LEL
ECO-D-B-13 Propane (C3H8) 0-100% LEL
ECO-D-B-14 HYDROGEN (H2) 0-2000 PPM
ECO-D-B-15 Petrol/Gasoline Vapor 0-100% LEL
ECO-D-B-16 Pentane (C5H12) 0-100% LEL
ECO-D-B-19 Ammonia (NH3) 0-100% LEL
ECO-D-B-20 ALCOHOL VAPOR 0-100% LEL
ECO-D-B-31 Oxygen (O2) 0-25% VOL
ECO-D-B-32 Oxygen (O2) 0-25% VOL - deficiency and enrichement alarm
ECO-D-B-41 Carbon Monoxide (CO) 0-500 PPM
ECO-D-B-42 Ammonia (NH3) 0-100 PPM
ECO-D-B-43 Hydrogen Sulfide (H2S) 0-100 PPM
ECO-D-B-44 Sulfur Dioxide (SO2) 0-10 PPM
ECO-D-B-45 Nitrogen Dioxide (NO2) 0-10 PPM
ECO-D-B-47 Cholrine (Cl2) 0-20 PPM
ECO-D-B-49 Carbon Dioxide (CO2) 0-5% VOL
ECO-D-B-11-31 Hydrogen (H2) 0-100% LEL + Oxygen (O2) 0-25% VOL
ECO-D-B-12-31 Methane (CH4) 0-100% LEL + Oxygen (O2) 0-25% VOL
ECO-D-B-12-41 Methane (CH4) 0-100% LEL + Carbon Monoxide (CO) 0-500 PPM
ECO-D-B-13-31 Propane (C3H8) 0-100% LEL + Oxygen (O2) 0-25% VOL
ECO-D-B-31-41 Oxygen (O2) 0-25% VOL + Carbon Monoxide (CO) 0-500 PPM
ECO-D-B-41-43 Carbon Monoxide (CO) 0-500 PPM + Hydrogen Sulfide (H2S) 0-100 PPM
ECO-D-B-41-45 Carbon Monoxide (CO) 0-500 PPM + Nitrogen Dioxide (NO2) 0-10 PPM
ECO-SC-11 HYDROGEN (H2) 0-100% LEL
ECO-SC-12 Methane (CH4) 0-100% LEL
ECO-SC-13 Propane (C3H8) 0-100% LEL
ECO-SC-14 Hydrogen (H2) 0-2000 ppm
ECO-SC-15 Petrol/Gasoline Vapor 0-100% LEL
ECO-SC-16 Pentane (C5H12) 0-100% LEL
ECO-SC-19 AMMONIA (NH3) 0-100% LEL
ECO-SC-20 ALCOHOL VAPOR 0-100% LEL
ECO-SC-31 OXYGEN (O2) 0-25% VOL - DEFICIENCY ONLY
ECO-SC-31-41 OXYGEN (O2) 0-25% VOL + (CO) 0-500 PPM
ECO-SC-32 OXYGEN (O2) 0-25% VOL - DEF AND ENR ALAR
ECO-SC-41 CARBON MONOXIDE (CO) 0-500 PPM
ECO-SC-41-43 CARBON MONOXIDE (CO) 0-500 PPM + (H2S) 0
ECO-SC-41-45 CARBON MONOXIDE (CO) 0-500 PPM + (NO2) 0
ECO-SC-42 AMMONIA (NH3) 0-100 PPM
ECO-SC-43 HYDROGEN SULFIDE (H2S) 0-100 PPM
ECO-SC-44 SULFUR DIOXIDE (SO2) 0-10 PPM
ECO-SC-45 NITROGEN DIOXIDE (NO2) 0-10 PPM
ECO-SC-47 CHOLRINE (CL2) 0-20 PPM
ECO-SC-49 CARBON DIOXIDE (CO2) 0-5% VOL
ECO-SC-11-31 Hydrogen (H2) 0-100% LEL + Oxygen (O2) 0-25% VOL
ECO-SC-12-31 Methane (CH4) 0-100% LEL + Oxygen (O2) 0-25% VOL
ECO-SC-12-41 Methane (CH4) 0-100% LEL + Carbon Monoxide (CO) 0-500 PPM
ECO-SC-13-31 Propane (C3H8) 0-100% LEL + Oxygen (O2) 0-25% VOL
ECO-FT15 ECO Adapters for VFT-15 and FT-15, includes pipe clips
VKT-002-US VESDA LaserPLUS VKT - 002 Sales Demo Kit includes VLP - 012.
VKT-004-US VESDA LaserCOMPACT VKT - 004 Sales Demo Kit includes VLC - 505.
VKT-050 VESDA LaserFOCUS Demo unit only, Demo unit with power connector plug installed and short length of
pipe, elbow, end cap and two pipe labels. LaserFOCUS 500
VKT-050-US VESDA LaserFOCUS Sales Demo - LaserFOCUS 500
VKT-601 ECO Demo Kit
VTT-10000-USA VESDA Test Transformer (Wire Burner): Previously known as the Hot Wire Test, this power supply unit is
used to test VESDA equipment. The unit provides 6VAC output from 220 - 240VAC or 110 - 120VAC supply.
A timer is incorporated to provide a selectable burn period of up to 3 minutes.
251-001 ASPIRATING SMOKETEST WIRE (100 METER)
VKT-301 OSID Demo kit consisting of 2 X OSE-SPW (fitted with alkaline batteries), 1 X OSI-90, 1 X OSID-INST, fitted in
a carry case with mounting plates
VKT-HIGH High Airflow Demo Kit: A spot detector is mounted under the hood below a perforated grill that contains a
AIRFLOW VESDA sampling point. Flexible tubing
connects a VESDA VLF Demo detector (not included) and the Demo Unit.
A fan directs 252 CFM onto the spot detector and the VESDA sampling
point simulating high airflow. A built in resistor burner on the base provides a puff of smoke. To
demonstrate, while the fan is operating, a button is pushed to heat the resistor. Smoke from the resister is
forced up to the spot detector and the VESDA sampling point. The VESDA Detector will go into full alarm,
the spot detector will not. VESDA VSC can be used to show smoke trend graphs.