Nothing Special   »   [go: up one dir, main page]

skip to main content
research-article

A comparative analysis of efficiency and reliability of capacitive micro-switches with initially curved electrodes

Published: 01 February 2020 Publication History

Abstract

Enhancement of both efficiency and reliability of MEMS structures has always been an interesting and even essential issue for research community. This paper provides a comparative investigation in this field focusing on the role of initially curved electrodes of capacitive micro-switches. Four models have been introduced by appliance of curved microbeams as either upper or lower electrodes of a capacitive MEMS switch, as well as the conventional base model with straight both electrodes. By introducing a mathematical model and appropriate numerical procedure, the contact area between two electrodes, which has direct effect on the reliability has been estimated using Hertz relation for all models. The electromechanical coupling factor which is related to the efficiency of the switch has been calculated considering the stored mechanical and electrical energy of the system. The results have shown that by appliance of an initial curvature to the both electrodes, the estimated contact area can increase up to 279% compared to the conventional switches. Also, a switch with straight moveable electrode and curved substrate exhibits an increase in coupling factor up to 24% compared to the base model, while increasing the pull-in voltage of the switch.

References

[1]
Attar A, Fathalilou M, and Rezazadeh G Mechanical behavior of a cylindrical capacitive micro-switch compared to a straight beam type J Mech Sci Technol 2019 33 2241-2248
[2]
Bao M and Wang W Future of microelectromechanical systems (MEMS) Sens Actuators A Phys 1996 56 135-141
[3]
Batra RC, Porfiri M, and Spinello D Review of modeling electrostatically actuated microelectromechanical systems Smart Mater Struct 2007 16 23-31
[4]
Becher D, Chan R, Hattendorf M, Feng M (2002) Reliability study of low-voltage RF MEMS switches. In: Proceedings of GaAs Mantech, pp 7–54
[5]
Beer FP and Johnston ER Mechanics of materials 2004 3 New York McGrawHill
[6]
Burns D, Zook J, Horning R, Herb W, and Guckel H Sealed-cavity resonant microbeam pressure sensor Sens Actuators A Phys 1995 48 179-186
[7]
Caronti A, Carotenuto R, and Pappalardo M Electromechanical coupling factor of capacitive micromachined ultrasonic transducers J Acoust Soc Am 2002 113 1 279-288
[8]
Costa J (2009) RF MEMS switch technology for radio front end applications. In: Proceedings of IEEE MTT-S international microwave symposium
[9]
Czaplewski DA, Nordquist CD, Dyck CW, Patrizi GA, Kraus GM, and William DC Lifetime limitations of ohmic, contacting RF MEMS switches with Au, Pt and Ir contact materials due to accumulation of ‘friction polymer’ on the contacts J Micromech Microeng 2012 22 105005
[10]
Fathalilou M, Rezazadeh G, Mohammadian A (2019) Stability analysis of a capacitive micro-resonator with embedded pre-strained SMA wires. Int J Mech Mater Des (online available)
[11]
Hunt FV Electroacoustics. The analysis of transduction, and its historical background 1982 Woodbury, NY AIP
[12]
Judy WJ Microelectromechanical systems (MEMS): fabrication, design and applications Smart Mater Struct 2001 10 1115-1134
[13]
Kim JM, Lee S, Baek CW, and Kwon Y Cold and hot-switching lifetime characterizations of ohmic-contact RF MEMS switches IEICE Electron Express 2008 5 11 418-423
[14]
Kinsler LE, Frey AR, Coppens AB, and Sanders JV Fundamentals of acoustics 1982 New York Wiley
[15]
Kumar J, Tetteh EA, and Braineard E A study of why electrostatic actuation is preferred and a simulation of an electrostatically actuated cantilever beam for MEMS applications IJESET 2014 6 5 441-446
[16]
Kwon H, Choi D-J, Park J-H, Lee H-C, Park Y-H, Kim Y-D, Nam H-J, Joo Y-C, Bu J-U (2007) Contact materials and reliability for high power RF-MEMS switches. In: Proceedings of the 20th IEEE international conference on micro electro mechanical systems, pp 231–234
[17]
Kwon H, Park J, Lee H, Choi D, Park Y, Nam H, and Joo Y Investigation of similar and dissimilar metal contacts for reliable radio frequency micorelectromechanical switches Jpn J Appl Phys 2008 47 8 6558-6562
[18]
Osterberg P (1995) Electrostatically actuated microelectromechanical test structures for material property measurements. Ph.D. dissertation, MIT, Cambridge, MA
[19]
Ouakad HM, Sedighi H, and Younis MI One-to-one and three-to-one internal resonances in MEMS shallow arches J Comput Nonlinear Dyn 2017 12 5 051025
[20]
Patel CD and Rebeiz GM A high-reliability high-linearity highpower RF MEMS metal-contact switch for DC–40-GHz applications IEEE Trans Microw Theory Tech 2012 60 10 3096-3112
[21]
Patton S and Zabinski JS Fundamental studies of Au contacts in MEMS RF switches Tribol Lett 2005 18 2 215-230
[22]
Puers R and Lapadatu D Electrostatic forces and their effects on capacitive mechanical sensors Sens Actuators A Phys 1996 56 3 203-210
[23]
Rebeiz GM and Muldavin JB RF MEMS switches and switch circuits IEEE Microw Mag 2001 2 4 59-71
[24]
Rezazadeh G, Fathalilou M, and Shabani R Static and dynamic stabilities of a microbeam actuated by a piezoelectric voltage Microsyst Technol 2009 15 1785-1791
[25]
Rezazadeh G, Fathalilou M, Shabani R, Tarverdilou S, and Talebian S Dynamic characteristics and forced response of an electrostatically-actuated microbeam subjected to fluid loading Microsyst Technol 2009 15 1355-1363
[26]
Rezazadeh G, Fathalilou M, and Sadeghi M Pull-in voltage of electrostatically-actuated microbeams in terms of lumped model pull-in voltage using novel design corrective coefficients Sens Imaging 2011 12 117-131
[27]
Vincent M, Rowe SW, Poulain C, Mariolle D, Chies L, Houzé F, and Delamare J Field emission and material transfer in microswitches electrical contacts AIP Lett 2010 97 26 263503
[28]
Yang Z, Lichtenwalner D, Morris A, Krim J, and Kingon AI Contact degradation in hot/cold operation of direct contact microswitches J Micromech Microeng 2010 20 10 105028
[29]
Yaralioglu G, Sanli Ergun A, Bayram B, Hæggstrom E, and Khuri-Yakub BT Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers IEEETrans Ultrason Ferroelectr Freq Control 2003 50 4 449-456
[30]
Liu Y, Bey Y, and Liu X Extension of the hot-switching reliability of RF-MEMS switches using a series contact protection technique IEEE Trans Microw Theory Tech 2016 64 10 3151-3162

Recommendations

Comments

Please enable JavaScript to view thecomments powered by Disqus.

Information & Contributors

Information

Published In

cover image Microsystem Technologies
Microsystem Technologies  Volume 26, Issue 2
Feb 2020
369 pages
ISSN:0946-7076
EISSN:1432-1858
Issue’s Table of Contents

Publisher

Springer-Verlag

Berlin, Heidelberg

Publication History

Published: 01 February 2020
Accepted: 06 July 2019
Received: 04 May 2019

Qualifiers

  • Research-article

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • 0
    Total Citations
  • 0
    Total Downloads
  • Downloads (Last 12 months)0
  • Downloads (Last 6 weeks)0
Reflects downloads up to 17 Dec 2024

Other Metrics

Citations

View Options

View options

Media

Figures

Other

Tables

Share

Share

Share this Publication link