Distribution Network Neutral Arc Suppression Coil Parallel Adjustable Resistance and Control Strategy

Published: 30 May 2020 Publication History

Abstract

Distribution network arc suppression coil parallel resistance grounding has the advantages of both arc suppression coil grounding mode and resistance grounding mode. However, the grounding mode of arc suppression coil parallel resistance is not pieced together simply with the two grounding modes. There are some technology problems needed to study deeply. These are studied for arc suppression coil parallel resistance grounding mode in the paper, including resistance value, put into time and run time of the resistance and so on. Based on protection tripping and isolating fault quickly after single phase grounding fault, and considering to sensitivity of protection and personal safety (touch voltage and step voltage), these control strategies are put forward, which include resistance value of parallel resistance, using adjustable resistance technology proposal and its adjustable range, put into time and run time of the resistance, and the fault line selection characteristic quantity.

References

[1]
LIU Mingyan. Selection of neutral grounding modes in power distribution network[J]. Power System Technology, 2004, 28 (16): 86--89.
[2]
SU Jifeng. Research of neutral grounding modes in power distribution network[J]. Power System Protection and Control. 2013, 41(8): 141--148.
[3]
LI Zhenqiang, PENG Qinghua, LI Hui, FAN Mian. Small Current Grounding System Presentation and Fault Processing Technology of State Grid. DISTRIBUTION & UTILIZATION, 2017, 34 (5): 2--6.
[4]
LIU Jian, RUI Jun, ZHANG Zhihua, et al. Smart grounding power distribution systems. Power System Protection and Control. 2018, 46(8): 130--133.
[5]
WU Xu-tao, AI Shao-gui, FAN Yi-ping. Field test study on XHG arc extinction harmonic eliminating and line selection over voltage protection device. Ningxia Electric Power, 2007, 2: 14--18.
[6]
TANG Shun-zhi. Analysis of Neutral Grounding for High-voltage House Service System in Power Plant. Journal of Chongqing Electric Power College, 2006, 11(1): 15--18.
[7]
Q/GDW 10370-2016, Chinese standard SN for books[S], 2017.
[8]
Lv Jun, Chen Weijiang, Qibo, Wang Xiaogang. Research on Overvoltage and Grounding Fault Line Selection of 10 kV Distribution Network Neutral Point under High Resistance Grounding Mode. Papers of 2007 Annual Meeting of High Voltage Professional Committee of China Electrical Engineering Society [C], 2007.
[9]
CHEN Wei-jiang, CAI Guo-xiong, CAI Ya-ping, et al. NEUTRAL GROUNDING MODE IN 10kV DISTRIBUTION NETWORK VIA PETERSON COIL WITH PARALLEL RESISTANCE. Power System Technology, 2004, 28(24): 56--60.
[10]
Chen Weijiang, Liu Youwei, Li Guofu, et al. Field test of flexible grounding tracking compensation arc suppression device for distribution network neutral point. Papers of 2006 Annual Meeting of High Voltage Professional Committee of China Electrical Engineering Society [C], 2006.
[11]
MENG Yi, YAN Tao, ZHOU Zhiqiang, PENG Jun. Experimental Study on Single Phase Grounding Fault of a Neutral Grounding Device Consisted of an Arc Suppression Coil and a Parallel Controllable Switching Low Resistance. Hubei Electric Power, 2017, 41(11): 20--23.
[12]
ZHOU Zhi-chen, FU Hui, LING Jian, et al. Single Phase-to-earth Test and Analysis for the Fault Line Selection Under Arc-suppression Coil Parallel Connecting the Mid-resistance. High Voltage Engineering, 2009, 35(5): 1054--1058.
[13]
LIU Jian, WANG Yuqing, RUI Jun, et al. Key Parameter of Smart Grounding Distribution Systems, Automation of Electric Power System, 2018, 42 (16): 180--184.
[14]
HAN Jing, XU Lijie. Study of a Neutral Grounding Method with an Arc Suppression Coil and a Parallel Low Resistance. High Voltage Engineering, 2005, 31(1): 38--39.
[15]
Lei Shaolan, Wang Guanjie, Zhou Lin. STUDY ON GROUNDING OF SYSTEM NEUTRAL THROUGH RESISTANCL OF MODERATE VALUE. Proceedings of the EPSA. 2000, 12(4): 28--30.
[16]
HUANG Zhifang, WEI Lixin, LI Gang. Flexible Grounding via Arc-suppression Coil and Low Resistance in Paralle. Guangdong Electric Power, 2014, 27(6): 64--67.
[17]
ZHANG Shengjian, PING Shaoxun. Grounding Method of High Resistance Parallelled with Arc Suppression Coil. High Voltage Engineering, 2006, 32(2): 117--118.
[18]
Luo Renyi. Research on Neutral Point Compound Grounding Mode of 10kV Distribution Network [D]. Chongqing: Chongqing University, 2016.
[19]
WANG Jiqing, SHEN Qiying. Single phase grounded line detection for power network with arc suppression coil grounding [J]. Power System Technology, 2003, 27(9): 78--79.
[20]
XUE Yongduan, ZHANG Q iufeng, YAN Tingchun, XU Bingyin. Fault feeder identification based on combined transient and power-frequency components in resonant grounded systems Automation of Electric Power System, 2014, 38(24): 80--85.

Recommendations

Comments

Please enable JavaScript to view thecomments powered by Disqus.

Information & Contributors

Information

Published In

cover image ACM Other conferences
ICITEE '19: Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering
December 2019
870 pages
ISBN:9781450372930
DOI:10.1145/3386415
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

Publisher

Association for Computing Machinery

New York, NY, United States

Publication History

Published: 30 May 2020

Permissions

Request permissions for this article.

Check for updates

Author Tags

  1. Adjustable resistance
  2. Arc suppression coil
  3. Control strategy
  4. Distribution network
  5. Neutral grounding style

Qualifiers

  • Research-article
  • Research
  • Refereed limited

Conference

ICITEE-2019

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • 0
    Total Citations
  • 28
    Total Downloads
  • Downloads (Last 12 months)3
  • Downloads (Last 6 weeks)0
Reflects downloads up to 16 Nov 2024

Other Metrics

Citations

View Options

Login options

View options

PDF

View or Download as a PDF file.

PDF

eReader

View online with eReader.

eReader

Media

Figures

Other

Tables

Share

Share

Share this Publication link

Share on social media