IPMEA Power Standard - Compress Air Guide

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 6

Cairo Technical Center

Power Standard
Implementation Guide
compress air control

IPMEA, June 2012


10 Golden Rules Implementation
10: Minimize Compressed Air

 Back to Content

IPMEA Power Standard Implementation Guide 2


10 Golden Rules Implementation
10: Minimize Compressed Air
Improvement opportunities
Replace elbows by sweeping bends

Remove unused pipe-work


Examine pipe-work layout – shortest distance
to point of use. Consider loop system
Check if pipe size is sufficient

Check bag filters for leaking


Eliminate inappropriate use diaphragm valves
by alternate methods
 Optimise system pressure – avoid
excessive pressure

Systematic leaks inspection, tagging & repair Monitor pressure at usage points

Ultra-sonic leak detection ?

Match air quality to use

Switch off compressors Automatic pressure control


when not in use (idling 25-
30%power)

Match compressor size to demand Check condensate traps

Monitor filter ΔP Variable speed compressor for control ? Change outlet filter elements regularly

Replace intake filters Control dryer using moisture sensor Condensate trap control – minimise leakage

Intake cool air best Waste heat recovery ?

IPMEA Power Standard Implementation Guide 3


10 Golden Rules Implementation
10: Minimize Compressed Air

Minimum Service & Maintenance

Oil Separator Change

Cooler Cleaning

Oil Filter Change

IPMEA Power Standard Implementation Guide 4


10 Golden Rules Implementation
10: Minimize Compressed Air
Specific Cases
 Homogenising compressors
 Check effectiveness of blending
 Consider conversion of high energy to low energy design

 Pneumatic conveying
 Check conveying velocity /pipe size / conveying air volume
 Number of bends
 Pipeline route

 Bag filters
 Optimisation of pulsing cycles
 Check for leaking purge valves

 Air blasters and air purges for cleaning


 Optimise cleaning cycles according to plant needs
IPMEA Power Standard Implementation Guide 5
10 Golden Rules Implementation
10: Minimize Compressed Air
Minimise Compressed Air (3) – Improvement Opportunities
 Operation & Maintenance
 Monitor system efficiency (kW/Nm3)
 Monitor demand curve
 Optimise system pressure – match supply to needs
 Eliminate inappropriate usage (ex: bearing cooling…)
 Conduct regular system inspection including leak detection & repair
 Remove unused pipe-work

 Control & Instrumentation


 Pressure control
 Pressure indication at usage points
 Compressor shutdown / variable speed compressor
 Moisture control for dryer

 Review System Design


 Pipe size
 Shortest distance to usage points
 Bend design
 Air intake
 Compressor sizes
 Match air quality to usage requirement
IPMEA Power
 Waste Standard
heat recoveryImplementation Guide 6