A O Smith Meter 2 Inch Steel Model C2
A O Smith Meter 2 Inch Steel Model C2
A O Smith Meter 2 Inch Steel Model C2
Features
Superior Accuracy – The Smith Meter® Rotary Vane
Meter principle, combined with the meter’s uniquely
designed (offset) inlet and outlet nozzles, minimizes
pressure drop across the measuring chamber, which
reduces flow through the meter clearances to maxi-
mize accuracy.
Low Pressure Drop – Streamlined flow path provides
low pressure drop.
Positive and Accurate Registration – High torque
drive calibrator with adjustment in 0.05% increments
ensures accurate registration.
Model C2-S1 with Large Numeral Counter and Ticket
Long Service Life – Low friction ball bearings, fixed Printer
cam-type timing, and rugged construction give sus-
tained accuracy and long service life.
Minimum Flow Rate – Typical Performance
Options Viscosity (Centipoise - mPa•s)
Linearity Units 0.5 1
2
5 20 100 400
High Viscosity Meter Clearances – To extend opera- USGPM 25 15 6 1.5 0.30 0.08
tion at maximum flow rate from 400 mPa•s to 2,000 ±0.15%
l/min 95 57 23 6.0 1.00 0.30
mPa•s.
USGPM 17 10 4 1.0 0.20 0.05
High Temperature Clearances – To extend operating ±0.25%
temperatures from 150°F to 200°F (65°C to 93°C). l/min 65 38 15 4.0 0.75 0.20
All Iron Trim – For operating temperatures above USGPM 13 8 3 0.8 0.16 0.04
±0.50%
200°F (93°C). l/min 50 30 11 3.0 0.60 0.15
LPG Trim – For low lubricity liquids such as LPG.
NACE Construction – Special components available Repeatability
to meet requirements of NACE Standard MR-01-75. ±0.02%
Viscosity
Operating Specifications
Standard: 400 mPa•s3 (2,000 SSU) maximum.
Maximum Flow Rate Optional: 2 Pa•s (10,000 SSU) maximum – specify “High
Viscosity Meter Clearances.”
USGPM L/min
Over 2 Pa•s: Specify “High Viscosity Meter Clearances”
Continuous Rating 125 475
and derate maximum flow rate in direct proportion to
Intermittent Rating1 150 570 viscosity over 2 Pa•s (e.g., at 4 Pa•s, derate Maximum
Continuous/Intermittent Rating - Flow Rate to 50% of normal continuous rating - 63
All Iron, and LPG Construction 100 375 USGPM).
1 Intermittent rating applies to service on clean, refined products where continuous operation is not required (e.g., truck loading, rail loading,
and other batching applications).
2 Linearity based on a maximum flow rate of 125 USGPM (475 L/min)
3 1,000 mPa·s = 1,000 cP = 1 Pa·s.
0 0
Meter Gearing 0 20 40 60 80 100 120 140 160
Flow - U.S. Gallons per Minute
Five U.S. gallons or 1 dekalitre per revolution of meter
calibrator output shaft (standard).
Installation
It is recommended that the meter be protected with a
suitable mesh strainer.
A 30°
9.4"
(239)
6"*
(152)
Note: Dimensions – inches to the nearest tenth (millimetres to the nearest whole mm), each independently dimensioned from respective
engineering drawings.
Counters
200 Series – Accumulative, nine-digit, non-reset type.
600 Series – Five large digit reset, eight small digit
non-reset.
7 Polytetrafluoroethylene (PTFE).
8 Specify: minimum/normal/maximum.
9 Standard seals supplied unless optional material specified.
10 For right-to-left flow on C2-S1 meters, add reversing gear kit.
11 Per revolution of LNC right hand wheel.
Headquarters: Operations: The specifications contained herein are subject to change without notice and any user of said
500 North Sam Houston Parkway West, Measurement Products and Equipment: specifications should verify from the manufacturer that the specifications are currently in effect.
Suite 100, Houston, TX 77067 USA Ellerbek, Germany +49 (4101) 3040 Otherwise, the manufacturer assumes no responsibility for the use of specifications which
Phone: +1 (281) 260 2190 Erie, PA USA +1 (814) 898 5000 may have been changed and are no longer in effect.
Fax: +1 (281) 260 2191
Contact information is subject to change. For the most current contact information, visit our
Integrated Measurement Systems:
website at www.fmctechnologies.com/measurementsolutions and click on the “Contact Us”
Corpus Christi, TX USA +1 (361) 289 3400 link in the left-hand column.
Kongsberg, Norway +47 (32) 286700
www.fmctechnologies.com/measurementsolutions