Ss 01007
Ss 01007
Ss 01007
Features
• Superior Accuracy – The Smith Meter® Rotary
Vane Meter principle, combined with the meter’s
uniquely designed (offset) inlet and outlet nozzles,
minimizes pressure drop across the measuring
chamber, which reduces flow through meter
clearances to maximize accuracy.
• Low Pressure Drop – Streamlined flow path Operating Specifications
provides low pressure drop.
• Positive and Accurate Registration – High Maximum Flow Rate
torque drive calibrator with adjustment in 0.05% USGPM L/min
increments ensures accurate registration.
Continuous Rating – Standard Trim 320 1,200
• Long Service Life – Low friction ball bearings,
Intermittent Rating1 – Standard Trim 400 1,500
fixed cam-type timing, and rugged construction
give sustained accuracy and long service life. Continuous / Intermittent Rating – All Iron
240 900
Trim
Options
Minimum Flow Rate –
• High Viscosity Meter Clearances – To extend Typical Performance
operation at maximum flow rate from 400 mPa•s Viscosity (Centipoise – mPa•s)
to 2,000 mPa•s. Linearity2 Units 0.5 1 5 20 100 400
• High Temperature Clearances – To extend USGPM 50 3
30 12 3.0 0.60 0.15
±0.15%
operating temperatures from 150°F to 200°F L/min 1903 113 45 11.3 2.30 0.57
(65°C to 93°C). USGPM 40 22 9 2.2 0.45 0.11
±0.25%
• All Iron Trim – For operating temperatures above L/min 150 83 34 8.3 1.70 0.42
200°F (93°C). USGPM 25 15 6 1.5 0.30 0.08
±0.50%
L/min 95 57 23 5.7 1.10 0.30
1 Intermittent rating applies to service on clean, refined products where continuous operation is not required (e.g., truck loading, rail loading, and other
loading or batching applications).
2 Based on a maximum flow rate of 320 USGPM (1,200 L/min).
3 Based on a maximum of 250 USGPM (950 L/min).
Repeatability Pressure Drop (∆P)
±0.02%
Flow - Litres per Minute
Viscosity 200 400 600 800 1,000 1,200 1,400
4
Standard: 400 mPa•s4 (2,000 SSU) maximum.
A - Meter 25.0
B
Optional: 2 Pa•s (10,000 SSU) maximum – specify “High B - Preset Valve
3 20.0
Viscosity Meter Clearances.” Data based on 0.82 sp. gr.,
2 mPa•s viscosity.
Over 2 Pa•s – Specify “High Viscosity Meter Clearances” and ∆P 15.0 ∆ P
2
psi kPa
derate maximum flow rate in direct proportion to viscosity over 10.0
2 Pa•s (e.g., at 4 Pa•s, derate maximum flow rate to 50% of A
1
5.0
normal continuous rating – 160 USGPM).
0
0 100 200 300 400
Temperature Flow - U.S. Gallons per Minute
Installation
Maximum Working Pressure
Standard: 150 psig (1,034 kPa) up to 200°F (93°C). It is recommended that the meter be protected with a 40
mesh strainer.
Meter Gearing
5 U.S. Gallons or 1 Dekalitre per revolution of meter Ordering Information
calibrator output shaft. Application Batching, Loading, Blending, Inventory,
Process Control, etc.
Operating Liquid – Name and sp. gr., Flow
Conditions Range6, Temp. Range6, Viscosity
Range6, Maximum Working Pressure
Seals Packing Gland: Buna7 Viton or PTFE8.
Valve: Buna7, Viton, EPR, or PTFE8.
Units of Gallons, Liters, Pounds, Kilograms.
Registration
Direction of Left-to-right flow (as viewed above) is
Flow standard and will be supplied unless
right-to-left flow is specified.
4 1,000 mPa•s = 1,000 cP = 1 Pa•s.
5 For other than petroleum applications, consult factory. Options and As required.
6 Specify: minimum/normal/maximum.
7 Standard seals supplied unless optional material specified.
Accessories
8 Polytetrafluoroethylene (PTFE).
Model AR3-1030-1, 3" Steel, Class 150 ANSI R.F. flanges. Type E – SPDT Mercury Wetted Switch.
LNC Pulse Transmitter (adapts to 600 Series Counters).
Mechanical Set-Stop Valves
Low-Resolution – 1 or 10 pulses9.
3" offset-type, ductile iron, Class 150 ANSI R.F. flanges.
High-Resolution (HR) – 50 or 100 pulses9.
Automatic Temperature Compensation PST – Dual-channel, high-resolution, security pulse genera-
Model ATC – Factory-set for a given product. tor.
Model ATG – Field-adjustable for different products, UPT – Universal Pulse Transmitter – High resolution dual
pulse quadrature output in a weather-tight explosion-proof
Counters
enclosure (up to 1,000 pulses/rev.).
200 Series – Accumulative, nine-digit, non-reset type.
600 Series – Field-adjustable for different products. Flow Rate Indicator
Meter Flanges
3" Class 150 14.5" 10.5"
ANSI B16.5 Raised Face (368) (267)
7.5"
5.8"
(191)
(147)
Steel Straight-Through
Preset Valve
4.1" 10.0"
(104) (254)
4-3/4" Bolt Holes equally spaced
on a 6.0" (152) dia. bolt circle.
11.2"
(284)
9.4"
(239)
5.4"
(137)
Top View
* Includes cover.
+Deduct 3.7" (94) if Preset Counter is not required.
Lb Kg
Meter 183 83
Meter/LNC+ 198 90
Preset Package+* 259 117
+ Add 10 lb (4.5 kg) if ticket printer is required.
+ Includes Meter, LNC, Preset counter and Valve.
The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in
effect. O
therwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.
Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the “Contact Us” link
in the left-hand column.
USA Operation
1602 Wagner Avenue
Erie, Pennsylvania 16510 USA
TechnipFMC P:+1 814.898.5000
FMC Technologies
Measurement Solutions, Inc. Germany Operation
500 North Sam Houston Parkway West, Smith Meter GmbH
TechnipFMC.com Suite 100 Regentstrasse 1
Houston, Texas 77067 USA 25474 Ellerbek, Germany
© TechnipFMC 2017 SS01007 Issue/Rev. 1.0 (9/17) P:+1 281.260.2190 P:+49 4101 304.0