MHM Series
For Hex-Style Models MHM2-MHM5
For assembly separate from the vessel:
1. Verify that the probe length is sufficient for your desired 12. Make the final adjustment of immersion length.
immersion. 13. Apply a backer wrench to the gland body flats to prevent
2. Thread the cap over the probes with the female thread rotation during torquing.
facing the process (see diagram). 14. While holding the backer wrench firmly in place, use a
3. Thread the follower over the probes with the keyway torque wrench to tighten the cap to the specified torque
towards the cap. (see chart).
4. Be sure you are using the correct sealant for your working 15. The assembly is now ready for use.
pressure and temperature. Thread the sealant over the
probes with the cone facing the process.
5. Thread the seat over the probes with the concave side
facing the sealant.
6. Thread the gland body over the probes.
7. Push on the follower until the sealant and seat are firmly
positioned in the gland body.
8. Align the follower and body to create a full keyway.
9. Place the pin in the keyway.
10. Thread the cap on finger tight.
11. Secure the gland body into a vice.
12. Make the final adjustment of immersion length.
13. Using a torque wrench, tighten the cap to the specified MHM Series
torque (see chart).
For Flange-Cap Model MHM6
14. The assembly is now ready for use. Apply a wrench to
the gland body flats – not the cap – for mounting to the For assembly separate from the vessel:
vessel. 1. Verify that the probe length is sufficient for your desired
immersion.
For assembly directly into a vessel: 2. Thread the flange/cap over the probes (see diagram).
1. Verify that the probe length is sufficient for your desired 3. Thread the follower over the probes with the counterbore
immersion. towards the cap.
2. Mount the gland body into the vessel wall. This may be 4. Be sure you are using the correct sealant for your
done by threading or welding, depending on the mounting working pressure and temperature. Thread the sealant
style. When using a weld mount, the gland must be over the probes with the cone facing the process.
disassembled prior to welding to protect the sealant. (Sealant may be in more than one layer.)
3. Thread the cap over the probes with the female thread 5. Thread the seat over the probes with the concave side
facing the process (see diagram). facing the sealant.
4. Thread the follower over the probes with the keyway 6. Thread the gland body over the probes.
towards the cap. 7. Push on the follower until the sealant and seat are firmly
5. Be sure you are using the correct sealant for your working positioned in the gland body.
pressure and temperature. Thread the sealant over the 8. Slide the flange/cap into place after the follower.
probes with the cone facing the process. 9. Thread the 6 cap screws in place and finger tighten.
6. Thread the seat over the probes with the concave side 10. Secure the gland body into a vice.
facing the sealant.
11. Make the final adjustment of immersion length.
7. Insert the probes through the body into the process.
12. Using a torque wrench, tighten the cap screws to 30-35
8. Push on the follower until the sealant and seat are firmly ft.- lbs. (40-47 N-m) per bolt. The cap screws should be
positioned in the gland body. progressively tightened in the order 1-4-2-5-3-6.
9. Align the follower and body to create a full keyway. 13. The assembly is now ready for use. Apply a wrench to the
10. Place the pin in the keyway. gland body flats for mounting to the vessel.
11. Thread the cap on finger tight.
2
For assembly directly into a vessel:
3
Lubricant Application Instructions 2. Apply a single line of lubricant to the full length of the
straight thread on the gland body. Refer to Figure 2.
3. Assemble the sealing gland per applicable sealing gland
Conax Technologies sealing glands have lubricant applied
instructions.
at the factory. Substitution of factory-supplied lubricant will
affect seal integrity. Lubrication prevents thread galling and
minimizes friction between mating metallic components
to maximize sealing gland performance when a catalog-
specified torque is applied. Lubrication should be used any
time a sealing gland assembly is opened for replacement or
adjustment of the probe(s), wires or sealant. By re-lubricating
the gland body threads and load bearing surface of the cap,
proper load transfer (sealant compression) can be achieved. Figure 2
Flange-Cap Style Sealing Glands
Lubricant kits are available from Conax Technologies in PG, MHM, EG and EGT Series
convenient, single application, disposable packages with the 1. Apply a small amount of lubricant, tear drop equivalent,
applicator included. Conax Technologies recommends use of in two to three places, equally spaced, to the underside of
this lubricant to ensure gland performance. the hex cap screw on each of the six (6) hex cap screws.
Do not allow the lubricant to directly contact the sealant
or the elements you are sealing. Refer to Figure 3.
Hex-Style Sealing Glands
2. Apply a single line of lubricant to the full thread length on
MK Series each of the six (6) hex head screws. Refer to Figure 3.
1. Apply a small amount of lubricant, a tear drop equivalent, 3. Assemble the sealing gland. Apply torque per applicable
in two to three places, equally spaced, to the ferrule top. gland chart.
Refer to Figure 1.
2. Apply a single line of lubricant to the full length of the
straight thread on the cap. Refer to Figure 1.
3. Assemble the sealing gland per MK sealing gland
instructions.
Figure 1 Figure 3
PG, MHM, MHC, TG, PL, EG, EGT, SPG, DSPG, CAUTION: Lubricant may cause mild eye irritation. Do not use for
lubrication of aluminum or magnesium parts.
PGS and BSWS Series
This product is not an OSHA hazardous material, as defined in
1. Apply a small amount of lubricant, tear drop equivalent,
29 CFR1910.120. This product contains CAS #9002839, Ethene,
in two to three places, equally spaced, to the top of the
chlorotrifluoro-homopolymer. 24-Hour Emergency Phone 1-800-733-
follower. Do not allow the lubricant to directly contact the
3665. HMIS Rating System: Health 0, Flammability 0, Reactivity 1.
sealant or the elements you are sealing. Refer to Figure 2.
For industrial use only.