Dell EMC VNXe3200 Hybrid Storage Datasheet PDF
Dell EMC VNXe3200 Hybrid Storage Datasheet PDF
Dell EMC VNXe3200 Hybrid Storage Datasheet PDF
SYSTEM
TheVNXe3200 is the most affordable unified hybrid flash and unified all flash storage
system, bringing the power of EMC’s VNX® to the IT generalist.
The VNXe3200
Specifications
HYBRID/ALL FLASH, UNIFIED ARCHITECTURE
The VNXe3200 is a dense, 2U dual-controller unified storage system that provides FC
and IP connectivity for concurrent SAN or NAS operations. With it you can:
The VNXe3200’s performance and low $/GB sets a new bar for entry-level storage.
CPU/Memory per Controller 1 x 2.2 GHz Xeon (Sandy Bridge) Quad Core/ 24 GB
SPECIFICATION SHEET
SYSTEM LIMITS AND SUPPORT
Maximum FS Size 16 TB
VNXe3200 CONNECTIVITY
The VNXe3200 provides flexible DAS, NAS, or SAN connectivity options through Ethernet
and Fibre Channel ports and supports a wide range of protocols including CIFS (SMB 1,
SMB 2 and SMB 3), NFSv3, iSCSI, and Fibre Channel
IO Modules VNXe3200
1GbE 4 ports per module
10GbE Optical 4 ports per module
Drive Enclosures 3.5” SAS, NL-SAS, Flash (2U) 2.5” SAS, Flash (2U)
Drive Quantity 12 25
Interface 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS 6 Gb/s SAS
Formatted
91.69 GB 183.41 GB 733.56 GB 268.37 GB 536.77 GB 536.77 GB 820.58 GB 1,117.8 GB 1823.56 GB 3668.55 GB
Capacity*
Form Factor 2.5”, 3.5” 2.5”, 3.5” 2.5” 2.5” 3.5” 3.5” 2.5” 3.5” 2.5” 3.5” 2.5” 3.5” 3.5” 3.5”
Height 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0”
N/A SSD 16 MB 16 MB 16 MB 16 MB 16 MB
Data Buffer N/A SSD N/A SSD 128 MB 128 MB
(min.) (min.) (min.) (min.) (min.)
SP to/from 600 MB/s 600 MB/s 600 MB/s 600 MB/s 600 MB/s 600 MB/s 600 MB/s 600 MB/s 600 MB/s 600 MB/s
Buffer (max) (max) (max) (max) (max) (max) (max) (max) (max)
3.5 ms 3.4 ms 3.7 ms 3.7 ms 3.7 ms 8.2 ms 8.5 ms
Average Seek (Read) (Read) (Read) (Read) (Read) (Read) (Read)
N/A N/A N/A
4.0 ms 3.9 ms 4.2 ms 4.2 ms 4.2 ms 9.2 ms 9.5 ms
(Write) (Write) (Write) (Write) (Write) (Write) (Write)
Rotation
Latency N/A N/A N/A 2.0 ms 2.0 ms 3.0 ms 3.0 ms 3.0 ms 4.17 ms 4.16 ms
* 100/200GB Flash drives are available in both FAST Cache and FAST VP supported versions. The VNXe3200 AFA uses the 200GB SSD for both
the 2.2TB and 3.2TB 2.5” DPE capacity models
** 800GB Flash drives are supported only in FAST VP. The VNXe3200 AFA uses the 800GB SSD for the 8.0TB 2.5” DPE capacity model
PROTOCOLS SUPPORTED
CIFS (SMB 1, SMB 2 and SMB 3), NFSv3, iSCSI, Fibre Channel
Network Lock Manager (NLM) v3, v4
Routing Information Protocol (RIP) v1-v2
Simple Network Management Protocol (SNMP)
Network Data Management Protocol (NDMP) v1-v4
Address Resolution Protocol (ARP)
Internet Control Message Protocol (ICMP)
Simple Network Time Protocol (SNTP)
Lightweight Directory Access Protocol (LDAP)
VMWARE INTEGRATION
VMware vStorage APIs for Array Integration (VAAI) for File and Block improves
performance by leveraging more efficient, array-based operations
vStorage APIs for Storage Awareness (VASA) provides storage awareness for VMware
administrators
VNXe ELECTRICAL SPECIFICATIONS
Requirement VNXe3200 VNXe3200 VNXe3200 VNXe3200
Processor Processor Expansion Expansion
Enclosure Enclosure Enclosure Enclosure
(3.5” Drives) (2.5” Drives) (12 x 3.5” (25 x 2.5”
Drives) Drives)
AC Line Voltage 100 to 240 V 100 to 240 V 100 to 240 V 100 to 240 V
ac± 10%, ac± 10%, ac± 10%, ac± 10%,
single-phase, single-phase, single-phase, single-phase,
47 to 63 Hz 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz
AC Line Current 5.2A max at 4.93A max at 2.5 A max at 2.5 A max at
100 V ac, 100 V ac, 100 V ac, 100 V ac,
2.6 A max at 2.47A max at 1.3 A max at 1.3A max at
200 V ac 200 V ac 200 V ac 200 V ac
Power Consumption 520 V ac (470 493 V ac (443 250 V ac (240 250 V ac 230
W) max W) max W) max W) max
Power Factor 0.98 min at full 0.98 min at full 0.98 min at full 0.98 min at full
load, low load, low load, low load, low
voltage voltage voltage voltage
Heat Dissipation 1.69 x 106 J/hr, 1.59 x 106 J/hr, 8.64 x 105 J/hr, 8.28 x 105 J/hr,
(1604 Btu/hr) (1512 Btu/hr) (820 Btu/hr) (785 Btu/hr)
max max max max
Dimension (H/W/L) 3.40 in x 17.5 3.40 in x 17.5 3.40 in x 17.5 3.45 in x 17.5
in x 20.0 in/ in x 17.0 in/ in x 20.0 in/ in x 13 in/
8.64 cm x 8.64 cm x 8.64 cm x 8.76 cm x
44.45 cm x 44.45 cm x 44.45 cm x 44.45 cm x
50.8 cm 43.18 cm 50.8 cm 33.02 cm
The limits under which equipment 18C to 27C (64.4Fto 80.6F) at 5.5C
RECOMMENDED RANGE OPERATION
will operate the most reliably while (41.9F) dew point to 60% relative
still achieving reasonably energy- humidity and 15C (59F) dew point.
efficient data center operation.
Data center economization 10°C to 35°C (50°F to 95°F) to 20%
CONTINUOUS ALLOWABLE RANGE OF
techniques (e.g. free cooling) may to 80% relative humidity with 21C
OPERATION be employed to improve overall data (69.8°F) maximum dew point
center efficiency. These techniques (maximum wet bulb temperature).
may cause equipment inlet De-rate maximum allowable dry bulb
conditions to fall outside the temperature at 1°C per 300m above
recommended range but still within 950m (1F per 547 ft above 3117ft).
the continuously allowable range.
Equipment may be operated without
an hourly limitation in this range.
During certain times of the year, 5°C to 10°C and 35°C to 45°C (with
EXPANDED ALLOWABLE RANGE OF
equipment inlet conditions may fall no direct sunlight on equipment) at -
OPERATION outside of the continuously allowable 12°C dew point and 8% to 90%
range but still within the two relative humidity with 24°C dew point
expanded ranges. Equipment (maximum wet bulb temperature).
operation is limited to ≤ 10% or ≤ Outside the continuously allowable
1% of the annual operating hours in range (10°C to 35°C), the system can
these ranges. operate down to 5°C or up to 40°C for
a maximum of 10% of its annual
operating hours. Additionally, the
system can operate as high as 45°C
for a maximum of 1% of its annual
operating hours. For temperatures
between 40°C and 45°C (104°F to
113°F), derate maximum allowable
dry bulb temperature by 1C per 125m
above 950m (1.8°F/410 ft above
2953 ft.).
When operating in the expanded Due to certain rare operational
EXCEPTIONS TO EXPANDED
allowable temperature range, system modes, it is recommended that
ALLOWABLE RANGE OPERATION performance is guaranteed while the service be deferred on the 2.5” and
system is waiting or being serviced. 3.5” Disk Array enclosures when
temperatures exceed 40°C.
20°C/hr (36°F/hr)
TEMPERATURE GRADIENT
3050m (10,000ft)
ALTITUDE
Statement of Compliance
This Information Technology Equipment is compliant with the electromagnetic compatibility (EMC) and product safety
regulations/standards required by the countries in which the product is sold. EMC compliance is based on FCC part 15,
CISPR22/CISPR24 and EN55022/EN55024 standards, including applicable international variations. EMC compliant Class A
products are marketed for use in business, industrial, and commercial environments. Product Safety compliance is based
on IEC 60950-1 and EN60951-1 standards, including applicable national deviations.
The individual devices used in this product are approved under a unique regulatory model identifier that is affixed to
each individual device rating label, which may differ from any marketing or product family name in this data sheet.
For additional information see https://support.emc.com under the Safety & EMI Compliance Information tab.
store.emc.com/vne
EMC2, EMC, the EMC logo, FAST, MCx, Unisphere, VNXe, VNXe3200, VNX, and VSPEX are
CONTACT US registered trademarks or trademarks of EMC Corporation in the United States and other
countries. VMware, ESX, and the VMware logo are registered trademarks or trademarks of
VMware, Inc., in the United States and other jurisdictions. Intel, the Intel logo, Xeon, and Xeon
To learn more about how EMC
Inside are trademarks or registered trademarks of Intel Corporation in the U.S. and other
products, services, and countries. All other trademarks used herein are the property of their respective owners. ©
solutions can help solve your Copyright 2010, 2014, 2015 EMC Corporation. All rights reserved. Published in the USA. 09/15
Specification Sheet H13842.4
business and IT challenges,
contact your local EMC believes the information in this document is accurate as of its publication date. The
representative or authorized information is subject to change without notice.
SPECIFICATION SHEET