Datasheet UHD Umbilical 39-5mm - A307667
Datasheet UHD Umbilical 39-5mm - A307667
Datasheet UHD Umbilical 39-5mm - A307667
942)
Umbilical Length = (First Layer of Conductor Length)x(0.943)
Umbilical Length = (Second Layer of Conductor Length)x(0.944)
751 Old Brandy Road Tele: 540 825-2111
Culpeper, Virginia 22701 Fax: 540 825-2238
Description
Inch mm
ELEMENT A; Single (5)
2
Cdr: #13 AWG (2.5 mm ) Cu 0.075 1.91
Ins: XLPE 0.156 3.96
ASSEMBLY
Core: Fill Rod 0.125 3.18
Layer 1: 5As with 2 drain
wires and fill rods in interstices.
Void filled and bound with
Cu/Poly tapes. 0.469 11.91
Layer 2: 9Bs and 1C with 4 drain
wires and fill rods in interstices.
Void filled bound with Cu/Poly
tapes 0.865 21.97
BELT
Rayolin 1.027 26.09
STRENGTH MEMBER
Layer #1: 41/0.0775" GFNEEIPS 1.182 30.02
Layer #2: 41/0.0885" GFNEEIPS 1.359 34.52
Layer #3: 42/0.098" GFNEEIPS 1.555 39.50
ROV Cable
The Rochester Code: RM0210873OO00
PHYSICAL
MECHANICAL
ELECTRICAL
dc Resistance
Element A 8.5 /km 2.6 /kft
Element B 2.5 /km 0.76 /kft
Insulation Resistance
Element A 9,000 Mkm 30,000 Mkft
Element B 3,000 Mkm 10,000 Mkft
Attenuation Rate
Element C
@ 1310 nm 0.45 dB/km --
@ 1550 nm 0.27 dB/km --
1
The relationship between sheave diameter and cable diameter is a critical factor used to establish a
products fatigue resistance or relative serviceability. Operation over smaller than recommended sheave
diameters may adversely effect service life.
ROV Cable
The Rochester Code: RM0210873OO00