APPLICATIONS
Safety in occupational environments
According to several safety regulations worker exposure cannot exceed
specified limits.
Emission from several industrial machines operating in the high frequen-
cy range could be potentially dangerous to the operator.
In the Near Field region near that kind of apparatus accurate measure-
ments of both Electric and Magnetic fields should be taken to demonstra-
te compliance to safety standards.
EHP-200, equipped with both electric and magnetic field sensors within a
small housing, is the ideal solution to perform accurate measurements
and spectrum analysis in the 9 kHz 30 MHz frequency range.
Its small size and optical output enables minimum field perturbation.
Broadcasting Surveillance
The EHP-200 is particularly useful in measuring the actual fields genera-
ted by long, medium and short wave broadcast transmitters, to ensure
safety around the sites of large antennas, to control power transmitted in
the radiation direction, to test transmitting antenna functions and identify
borders between near and far field regions.
Wave impedance
As a unique feature, the PC program calculates field wave impedance by
dividing the total value of the E-field by that of the H-field. This method is
particularly suitable for evaluating the non-linear, scattered near-field
region of large broadcast antenna systems.
Both electric and magnetic fields can be displayed on the Power density spectrum is calculated over real electric
same graph. and magnetic field measurement and therefore applicable
to both far and near field conditions.
The8053-Display
in Analog mode
TECHNICAL SPECIFICATIONS
EHP-200A E&H FIELD ANALYSER
RF Specifications Electric Field Magnetic Field Magnetic Field AUX Input
Mode A Mode B
Frequency Range 9 kHz 30 MHz 9 kHz 3 MHz 300 kHz 30 MHz 9 kHz30 MHz
Measurement Range @ 10 kHz RBW 0.1 1000 V/m 0.03 300 A/m 3 mA/m 30 A/m -80 0 dBm
@ preamp. ON 0.02 200 V/m 6 mA/m 60 A/m 0,6 mA/m 6 A/m -94 -14 dBm
Dynamic range > 80 dB
Sensitivity @ 10 kHz RBW 0,1 V/m 30 mA/m 3 mA/m -80 dBm
@ preamp. ON 0,02 V/m 6 mA/m 0,6 mA/m -94 dBm
Resolution 0.01 V/m 1 mA/m 0.1 mA/m 0.01 dB
Flatness 0.5 dB@20 V/m 0.8dB@166mA/m 0.8dB@53mA/m 0.4dB@-20 dBm
0.1 27 MHz 0.15 3 MHz 0.3 27 MHz
Anisotropy 0.8 dB @ 1 MHz
Linearity 0.5 dB @ 1 MHz from Full Scale to -60 dB FS
Frequency span width 0 to 30 MHz
Resolution bandwidth 1 kHz - 3 kHz - 10 kHz - 30 kHz - 100 kHz - 300 kHz
Rejection to E- Field --- > 20 dB > 20 dB ---
Rejection to H- Field > 20 dB --- --- ---
Calibration Internal EEPROM
Temperature error 0.02 dB/C
General Specifications
AUX input 50 ; type MMCX
Preamplifier 14 dB, selectable ON/OFF
Reading Units V/m, A/m, T, mW/cm2, W/m2
(additional units mG, Ohm and % of selected limit
are available with the provided control software)
Optical link Optical Fibre, max. length 80m (40m with USB - OC)
Internal battery 3.7 V 5.55 Ah Li-Ion, rechargeable
Battery operation > 12 hours (recharging time: approx. 8 hours)
External supply 10 15 VDC, 560 mA
Firmware update Via optical fibre
Operating temperature -10 C to 50 C
Storage temperature -20 C to 70 C
Dimensions and weight 92 x 92 x 109 mm - 580 g
Recommended calibration interval 24 months
Country of origin Italy
ORDERING INFORMATION
EHP-200A Part Number (P/N)
EHP-200A Electric and Magnetic field analyzer
Includes:
- EHP-200A Basic Unit
- 8053-SC Soft carrying case, holds basic unit and accessories including 8053-Display (650.000.035)
- AC/DC battery charger (650.000.036)
- International AC plug adapters (UK:650.000.037, USA:650.000.038, Australia: 650.000.039, Italy: 650.000.040)
- FO-8053/10 Cable, fiber optic 10m (650.000.053)
- FO-10USB Cable, fiber optic 10m (650.000.177)
- Optical-USB converter (650.000.176) 650.000.201
- Plastic rod support, 50cm (231.800.012)
- Mini tripod, bench top (650.000.151)
- PC software, CD-ROM
- Operating Manual EHP-200A
- Certificate of calibration
- Return for repair form
ACCESSORIES
8053-OC Optical to RS232 converter 650.000.062
8053-OC-PS optional power supply for 8053-OC 650.000.179
FO-8053/20 Cable, fiber optic 20m 650.000.055
FO-8053/40 Cable, fiber optic 40m 650.000.052
FO-8053/80 Cable, fiber optic 80m 650.000.128
FO-20USB Cable, fiber optic 20m 650.000.178
FO-40USB Cable, fiber optic 40m 650.000.182
TR-02A wooden tripod 1-2m with soft carrying bag 655.000.005
TT-01 telescopic mast (120-420 cm) with carrying bag 650.000.005
8053-Display display unit 620.000.057
8053-CA car adapter 650.000.058
8053-CC rigid case 650.000.059
Narda Safety Test Solutions GmbH Narda Safety Test Solutions Narda Safety Test Solutions Srl
Sandwiesenstrasse 7 435 Moreland Road Via Leonardo da Vinci, 21/23
72793 Pfullingen, Germany Hauppauge, NY 11788, USA 20090 Segrate (MI) ITALY
Phone: +49 (0) 7121-97 32-777 Phone: +1 631 231-1700 Phone: +39 02 26.998.71
Fax: +49 (0) 7121-97 32-790 Fax: +1 631 231-1711 Fax: +39 02 26.998.700
E-Mail: support@narda-sts.de E-Mail: NardaSTS@L-3COM.com E-Mail: support@narda-sts.it
www.narda-sts.de www.narda-sts.com www.narda-sts.it