FIRE ALARM CONTROL PANEL BS-420

AutroSafe Interactive Fire Detection System


Product Datasheet

Features
SelfVerify function for automatic testing of

detectors
Automatic addressing of detectors
AutroFieldBus
Accommodates up to a maximum of 12 modules,
of which maximum 6 can be Loop Driver
Modules
User-friendly display and operator controls
Backlit operational buttons. Text display suitable
for full darkness operation
Surface mounting on wall
Rack mounting in standard 19 cabinets
Conforms to CE standards
Designed to meet IEC 61508 SIL2 requirements,
CEN, EN 54-2, EN 54-4 and EN 54-13 regulations,
FM regulations (Factory Mutual) and the
maritime SOLAS requirements (Safety Of Life At
Sea)

Description / Application
BS-420 is a complete fire alarm control panel with
full operation capabilities. The panel serves as an
operating panel for one or several defined
operation zones. All alarm handling and system
features can be controlled and monitored from the
panel.
The panel can accommodate up to a maximum of
12 modules. The system offers Loop Driver Modules
for detection loops and several types of I/O
modules (see Optional Modules below).
There can be a maximum of 6 Loop Driver Modules
in each panel. All modules are easily plugged onto
each other on a standard mounting rail inside the
unit.
The panel provides connections for 2 Ethernet ports
and 2 USB host ports.
The panel is menu operated on a 16-line display,
with 40 characters per line. A built-in printer is
available as an option. The panel communicates
with other system units on the Ethernet-based local
area network, AutroNet.

116-P-BS420/CGB, Rev. E, 2016-05-19

Optional Modules
Loop Driver Module (BSD-310/311) for

connection of detection loops

Output Module (BSB-310) with 4 monitored

outputs

Output Module (BSJ-310) with 8 open collector

non-monitored outputs
Input Module (BSE-310) with 4 monitored inputs
Input Module (BSE-320) with 8 non-monitored
inputs (galvanically isolated)

Indicators
16 x 40-character alphanumeric display
Fire, More Events, Fire Brig. Signalled, Fault,

Function Disabled, Testing, System Fault, Power,


Function Delayed, Alarms Fault, Fire Brig. Fault,
Alarms Disabled, Fire Brig. Disabled, Detector
Inhibit, Extinguishing Activated, Extinguishing
Isolated, Local Mode, Dual Safety Stdby, MultiS
SmokeDis.
Internal buzzer

Protecting life, environment and property

Fire Alarm Control Panel BS-420

Operator Controls

More Events, Mute Panel, Silence Alarms, Reset System, Menu, Close Window
Keyboard with alphanumeric characters and scroll function
Separate buttons for menu operation
Backlit buttons and text

Capacity

64 system units (panels) on the local area network; AutroNet


15000 loop units per system
12 modules per fire alarm control panel, of which 6 can be Loop Driver Modules
512 detectors and manual call points can be connected to each Fire Alarm Control Panel (EN 54)
31 AutroFieldBus units connected to AutroFieldBus
127 loop units connected to one detection loop
40 socket/loop sounders connected to one detection loop
15 loop units connected to one Powerloop

Dimensions (mm)

148

161

Autronica Fire and Security AS

Tel.: +47 90 90 55 00

E-mail: info@autronicafire.no

www.autronicafire.com

Page 2

Fire Alarm Control Panel BS-420

Product Name

Part number

Description

BS-420

116-BS-420

Fire alarm control panel

Technical specifications
Dimensions (mm)

350 x 350 x 161

Cut-Out Dimensions (mm)

320 x 330 x 140

Weight (kg)

8,5 kg

Materials

Steel cabinet, ABS/PC moulded front

Mounting

Surface or flush mounting

Protection class

IEC-529 / IP32

Operating Temperature

-15 C to +70 C

Storage Temperature

-40 C to +70 C

Power supply

Nom. 27,2 VDC (18-32 VDC)

Current consumption

156 mA/27,2 VDC (idle)


Max. 340 mA/27,2 VDC (lamp test)

Capacity Loop Driver Modules and I/O Modules

Maximum 12 modules
(A combination of BSD-310, BSB-310, BSE-310/320 and BSJ-310)

Capacity Loop Driver Module

Maximum 6 BSD-310/BSD-311. The maximum number of detectors and manual


call points that can be connected to these 6 modules are 512 (refer to
EN 54). Maximum 127 detectors/manual call-points/electronic sounders/ I/O
units on each detection loop.

Detector connection

By use of BSD-310/ BSD-311

Inputs

By use of BSE-310 and BSE-320

Outputs

By use of BSB-310 and BSJ-310

Communication

AutroNet (Ethernet-based local area network)

Communication Ports

2 Ethernet ports
2 USB host ports (max. 100mA)
1 serial port for the std. detection loop communication protocol
1 RS-232, RS-422 or RS-485 serial port for communication with third party
equipment (AutroCom /ESPA4.4.4/MODBUS/VDR)
1 AutroFieldBus (AFB) interface
1 RS-485 serial port for communication with the front panel
FailSafe relay output

Ethernet Cable

CAT 5 or better. Shielded cable required in maritime installations. Max. 100m


between Ethernet nodes

Approvals

www.autronicafire.com

Autronica Fire and Security AS

Tel.: +47 90 90 55 00

E-mail: info@autronicafire.no

www.autronicafire.com

Page 3