Catalogue NEXTYS 2014 V1-0
Catalogue NEXTYS 2014 V1-0
Catalogue NEXTYS 2014 V1-0
CATALOGUE
NEXTYS
www.nextys.com
SWITZERLAND
.
.
.
s
t
c
u
d
o
r
p
n
e
e
Gr
...
!
y
r
t
n
u
o
c
n
e
e
r
g
a
from
INDEX
Introduction
About Us
How to reach NEXTYS
Quality Approvals and Standards Compliance
2
3
4
Switching Power Supply - NPSM 20/40/80 (1 PHASE, CLASS II, LOW POWER FOR GENERAL PURPOSE)
NPSM20
NPSM40
NPSM80
12
13
14
Switching Power Supply - NPSM 85/120/240/480/501 (1 PHASE, MEDIUM POWER FOR GENERAL PURPOSE)
NPSM85
NPSM120
NPSM240
NPSM480
NPSM501
16
17
18
19
20
Switching Power Supply - NPSM 121/241/481 (1 PHASE, MEDIUM POWER PREMIUM, ULTRACOMPACT)
NPSM121
NPSM241
NPSM481
22
23
24
26
27
28
29
32
34
35
36
38
39
DC/DC CONVERTERS
NDD120
NDD240
42
43
44
45
46
47
MONITORING SYSTEMS
BATTMASTER
POWER MASTER Software
50
51
CUSTOM SOLUTIONS
MBC2K
WEPS160
WM100-24
USW1-5
NPSR10-5
54
55
56
57
58
NOTES:
1) In order to continuously improve our products we reserve the right to change the specifications without notice
2) All shown parameters are typical
About Us
NEXTYS is a high tech Swiss company, founded in 1998.
A
Directions:
- From A2/E35 highway (any direction)
- Use Exit 47 - Bellinzona Sud towards Locarno
- Continue for about 6.5Km, exit to Luserte Sud
Driving time:
- One hour and half from Milan airports
- Half hour from Lugano
Power supplies are the heart of every electrical system application. Unsuitable devices
can cause system breakdown and important subsequent costs. Modern power supplies
must offer maximum efficiency, compact sizes and supply constant power under critical
conditions.
By deploying the latest technology, including digital solutions, our products reached top
performance by:
COMPACTNESS
50% volume savings vs. market average, small size without compromising in quality or
reliability
EFFICIENCY
Decreased power consumption and reduced energy cost, achieving significant saving
FLEXIBILITY
Most of our products offer wide input voltage and optimized output voltage range, to meet
several applications in one unit. We cover all voltages from 5 to 180Vdc (within several
models) in order to meet the different requirements.
RELIABILITY
By implementing simple topologies and digital solutions we can guarantee the maximum
safety for the system. Thanks to power boost by 50%, remote control, monitoring software,
diagnosis tools and various protection circuitry most of the critical operating conditions are
well covered.
This family covers the lower power applications in the range 20 to 80W.
The units are hosted in a rugged plastic housing that is compliant with the
DIN size standard for circuit breakers, easing their installation in standard
cabinets. 2 wires connection saves costs also. Output voltages range from
5 to 24Vdc (model dependent).
They cover 120 to 240W with wide range input and output. They match
many applications where the power conversion needs a compact solution.
MONITORING SYSTEMS
BATTMASTER is an innovative high tech, compact battery monitoring
system, based on wireless communication. Easy to install and operate,
its the first wireless BMS (Battery Monitoring System) on the market.
POWERMASTER is a software tool used to configure and monitor the
operation for various advanced products from our product line.
CUSTOM SOLUTIONS
These products are of specific design and they cover applications as e.g.
railway, residential, elevators, medical, motor control.
10
NPSM 20/40/80: 1 PHASE, CLASS II, LOW POWER FOR GENERAL PURPOSE
Applications:
80W
40W
20W
Input
Out (Vdc)
90......264Vac
5...15
2x12...15
100......370Vdc
12...15
24
11
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Continuous current
Overload limit
Load regulation
Ripple
Hold up time
(Vin = 230Vac)
NPSM20-12
NPSM20-24
Fixed 12Vdc
1.65A
Fixed 24Vdc
0.85A
Overload (200% In) / short circuit
< 1%
< 100 mVpp
> 20ms
Overload/short circuit: hiccup
Over temperature
Possible with external Oring diode
DC OK green LED
Protections
Parallel connection
Status Signals
INPUT DATA
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
12
400mA
300mA
< 5A
> 0.6
Fuse 1AT / 250V (internal - not user replaceable)
MCB 2A C curve
> 80%
> 83%
< 4W
- 20C+ 70C
- 0.5W/C over 50C
II
2 (IEC664-1)
4.2kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-4, EN61000-6-2
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Flame retardant UL 94 V-0 plastics
0.1kg
35 x 90 x 61.5mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Load regulation
Ripple
Hold up time
(Vin = 120Vac)
(Vin = 230Vac)
NPSM40-515
NPSM40-12D
NPSM40-12
NPSM40-24
515Vdc
515Vdc
4A @ 5Vdc
2A @ 15Vdc
5.5A @ 5Vdc
2.9A @ 15Vdc
2 x 1216Vdc
2 x 1216Vdc
12Vdc
1215Vdc
3.5A @ 12Vdc
3A @15Vdc
7A @ 12Vdc
6A @ 15Vdc
24Vdc
Fixed 24Vdc
2 x 1A
2 x 2.7...3.1A
> 50ms
> 60ms
> 30ms
> 100ms
Overload/short circuit: hiccup
Over temperature
Possible with external Oring diode
DC OK green LED
Parallel connection
Status Signals
INPUT DATA
> 20ms
> 60ms
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
3.5A
< 5%
< 50mVpp
Protections
GENERAL DATA
2A
0.70A
0.40A
0.90A
0.50A
< 30A
> 0.6
Fuse 2AT / 250V (internal - not user replaceable)
MCB 4A C curve
> 80%
> 83%
> 87%
> 85%
< 6W
< 8W
- 20C+ 70C (over temperature protection)
- 0.25W/C over 50C
- 0.35W/C over 50C
II
2 (IEC664-1)
4.2kVdc
UL508 (certified), EN60950, CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Flame retardant UL 94 V-0 plastics
0.25kg
72 x 90 x 61.5mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
13
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 120Vac)
(Vin = 230Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
14
NPSM80-24
24Vdc
23.527.5Vdc
3.3A
4A
20A
< 1%
< 50mVpp
> 10ms
> 30ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
33Vdc Max.
Possible with external Oring diode
DC OK green LED
AC: 120240Vac / 47...63Hz (range 90264Vac)
DC: 110...345Vdc (UL508 Certified for 300Vdc)
1.4A
0.85A
< 30A
> 0.6
Fuse 2AT / 250V (internal - not user replaceable)
MCB 4A C curve
> 88%
< 9.5W
- 20C+ 70C (over temperature protection)
- 0.9W/C over 55C
II
2 (IEC664-1)
4.2kVdc
UL508 (certified), EN60950, CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Flame retardant UL 94 V-0 plastics
0.25kg
72 x 90 x 61.5mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
Applications:
Industrial automation
Process control
Heavy duty applications
Building automation and general purpose
40mm
40mm
63mm
85W
120W
240W
15
IND.CONT.EQ
4WX9
D
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 120Vac)
(Vin = 230Vac)
NPSM85-5
5Vdc
4.755.25Vdc
8.5A
11A
20A / 40ms
Status Signals
INPUT DATA
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
16
NPSM85-24P
24Vdc
2327.5Vdc
3.5A
5A
30A / 50ms
< 1%
20A / 50ms
< 20mVpp
> 20ms
> 50ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
> 6.8Vdc
Possible with external Oring diode
DC OK green LED
Dry contact 1A / 24Vdc
> 33Vdc
Factory provided with int. Oring diode
NPSM85-24
< 130mVpp
Protections
Output overvoltage protection
Parallel connection
1.0A
0.6A
1.5A
0.9A
< 25A
> 0.6
Fuse 2AT / 250V (not user replaceable)
Fuse 4AT or MCB 4A C curve
> 75%
< 14W
> 88%
< 11W
- 20C+ 70C (over temperature protection)
No derating
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Aluminum
0.4kg
40 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
> 87%
< 13W
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 120Vac)
(Vin = 230Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
NPSM120-12
1215Vdc
1215Vdc
7A
11...9.5A
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
NPSM120-24
NPSM120-24P
24Vdc
2327.5Vdc
5A
7.5A
30A / 30ms
< 1%
< 30mVpp
D
NPSM120-48P
48Vdc
4555Vdc
2.5A
3.7A
> 20ms
> 70ms
> 25ms
> 15ms
> 30ms
> 60ms
> 60ms
> 60ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
> 18Vdc
> 33Vdc
> 68Vdc
Possible with external Oring diode
Factory provided with internal Oring diode
DC OK green LED
Dry contact 1A / 24Vdc
AC: 120240Vac / 47...63Hz (range 85264Vac)
DC: 110...345Vdc
1.9A
1.1A
2.1A
1.2A
< 25A
> 0.6
Fuse 3.15AT / 250V (not user replaceable)
Fuse 4AT or MCB 4A C curve
> 85%
< 19W
> 87%
> 86%
< 17W
< 20W
- 20C+ 70C (over temperature protection)
- 2.4W/C over 60C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Aluminum
0.4kg
40 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
> 87%
< 17W
17
IND.CONT.EQ
4WX9
D
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 120Vac)
(Vin = 230Vac)
NPSM240-12
NPSM240-24
12...15Vdc
12...15Vdc
16...14A
19...16A
42A / 140ms
> 100ms
> 90ms
> 6.8Vdc
Possible with external Oring diode
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
18
48Vdc
4555Vdc
5A
6.8A
20A / 160ms
72Vdc
7285Vdc
3.5A
4.6A
14A / 150ms
> 80ms
> 80ms
> 90ms
> 80ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
> 33Vdc
> 68Vdc
> 100Vdc
Factory provided with internal Oring diode
DC OK green LED
Dry contact 1A / 24Vdc
AC: 120/240Vac / 47...63Hz (range 90132 / 187...264Vac) settable with Voltage Input Selector
DC: 270...345Vdc
GENERAL DATA
NPSM240-72P
< 1%
< 100mVpp
Status Signals
INPUT DATA
NPSM240-48P
24Vdc
2327.5Vdc
10A
13.5A
35A / 150ms
Protections
Output overvoltage protection
Parallel connection
NPSM240-24P
4.0A
2.0A
< 35A
> 0.6
Fuse 6.3AT / 250V
Fuse 10AT or MCB 10A C curve
... > 86%
... < 34W
> 88%
> 86%
> 88%
< 33W
< 35W
< 30W
- 20C+ 70C (over temperature protection)
- 5.0W/C over 50C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Aluminum
0.72kg
63 x 140 x 117mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
> 88%
< 34W
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 230Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
Input rated voltage frequency
Input rated current
(Vin = 230Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
NPSM480-24
24Vdc
2327.5Vdc
20A
28A / 5s
50A
<1%
< 100mVpp
> 20ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
> 33Vdc
Possible with external Oring diode
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
AC: 240Vac / 47...63Hz (range 187264Vac)
DC: 250...345Vdc
2.5A
< 20A
> 0.95
None, external fuse must be provided
Fuse 6.3AT or MCB 6A C curve or 4A D curve
> 92%
< 42W
- 20C+ 60C (over temperature protection)
- 16W/C over 45C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
1kg
73 x 140 x 125mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 20mm spacing between adjacent items
19
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 230Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
Input rated voltage frequency
Input rated current
(Vin = 120Vac)
(Vin = 230Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
20
NPSM501-24
NPSM501-48
NPSM501-72
24Vdc
2327.5Vdc
20A
30A / 5s
> 50A / 5s
48Vdc
4555Vdc
10A
15A / 5s
> 40A / 5s
<1%
< 100mVpp
72Vdc
7285Vdc
6A
10A / 5s
> 20A / 5s
> 35ms
Overload, short circuit, with constant or hiccup mode (user settable)
Thermal protection
Input Undervoltage lockout
> 33Vdc
> 68Vdc
> 100Vdc
Up to 4 units for increased power
DC OK green LED
ALARM red LED
Dry contact 1A / 24Vdc
AC: 120 / 230Vac / 47...63Hz (range 90132 / 187264Vac)
DC: 250...345Vdc
8.4A
4.4A
< 35A
> 0.65
None, external fuse must be provided
Fuse 10AT or MCB 10A C curve
> 92%
< 42W
- 20C+ 60C (over temperature protection)
- 10W/C over 45C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508 (certified), EN60950, CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
1.56mm, screw type header (16...10AWG)
Aluminum
1.2kg
80 x 127 x 137.5mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 50mm spacing between adjacent items
Applications:
35mm
54mm
73mm
21
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 120Vac)
(Vin = 230Vac)
NPSM121-24
Status Signals
INPUT DATA
Input rated voltage frequency
Input rated current
(Vin = 120Vac)
(Vin = 230Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
GENERAL DATA
User Interface
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
22
NPSM121-24P
NPSM121-48
24Vdc
11.528.5Vdc
5A
7.5A
15A in Hiccup mode, 7.5A in constant current mode
NPSM121-48P
48Vdc
2255Vdc
2.5A
3.75A
7.5A in Hiccup mode, 3.75A in constant current mode
< 1%
< 50mVpp
Protections
Output overvoltage protection
Parallel connection
Redundancy
No
> 20ms
> 40ms
Overload, short circuit, with constant or hiccup mode (user settable)
Thermal protection
Input Undervoltage lockout
Active > 30Vdc
Active > 68Vdc
Up to 4 units for increased power
Internal Oring diode
No
Internal Oring diode
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
AC: 120240Vac / 47...63Hz (range 85264Vac)
DC: 110...345Vdc
1.3A
0.65A
< 30A
> 0.92 @ full load
Fuse 3.15AT / 250V (not user replaceable)
Fuse 4AT or MCB 4A C curve
DC OK LED (U out > 0.8 Uset)
Overload LED
Current limitation mode jumper
Dry contact (1A)
> 91%
< 12W
- 20C+ 70C (over temperature protection)
-6W/C over 60C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Aluminum
0.2kg
35 x 103 x 104mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
Input rated voltage frequency
Input rated current
(Vin = 120Vac)
(Vin = 230Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
NPSM241-24
NPSM241-48
NPSM241-72
24Vdc
11.528.5Vdc
10A
15A
30A in Hiccup mode
15A in constant current mode
48Vdc
72Vdc
2255Vdc
3385Vdc
5A
3.3A
7.5A
5A
15A in Hiccup mode
7.5A in Hiccup mode
7.5A in constant current mode
5A in constant current mode
< 1%
< 50mVpp
> 20ms
Overload, short circuit, with constant or hiccup mode (user settable)
Thermal protection
Input Undervoltage lockout
Active > 30Vdc
Active > 60Vdc
Active > 90Vdc
Up to 4 units for increased power
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
23
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
INPUT DATA
Input rated voltage frequency
Input rated current
(Vin = 120Vac)
(Vin = 230Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
24
NPSM481-24
NPSM481-48
24Vdc
11.528.5Vdc
20A
30A
50A in Hiccup mode
30A in constant current mode
NPSM481-72
48Vdc
72Vdc
2255Vdc
3385Vdc
10A
6.7A
15A
10A
30A in Hiccup mode
15A in Hiccup mode
15A in constant current mode
10A in constant current mode
< 1%
< 50mVpp
> 20ms
Overload, short circuit, with constant or hiccup mode (user settable)
Thermal protection
Input Undervoltage lockout
Active > 30Vdc
Active > 60Vdc
Active > 90Vdc
Up to 4 units for increased power
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
AC: 120230Vac / 47...63Hz (range 85264Vac)
DC: 110...345Vdc
4.8A
2.4A
< 30A
> 0.92 @ full load
Fuse 6.3AT / 250V (not user replaceable)
Fuse 6.3A or MCB 10A C curve
> 93%
< 36W
- 20C+ 60C (over temperature protection)
No derating up to 60C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508 (certified), EN60950, CE marking
EN61000-6-4, EN61000-6-2
IP20 acc. To EN60529
2.5mm, screw type header (24...12AWG)
Aluminum
0.8kg
73 x 140 x 125mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
Applications:
12
Vdc (Out)
24
48
72
25
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 400Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
Input rated voltage frequency
Input rated current
(Vin = 400Vac)
(Vin = 500Vac)
Inrush peak current
(Vin = 400Vac)
Power factor
(Vin = 400Vac)
Internal protection fuse
External protection on AC line
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
26
NPST480-24
24Vdc
2327.5Vdc
20A
28A / 5s
50A
<1%
< 100mVpp
> 20ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
> 33Vdc
Possible with external Oring diode
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
AC: 3 phase, 400500Vac / 4763Hz (range 340550Vac)
DC: 470...725Vdc
1.1A
0.8A
< 40A
> 0.92
None, external fuse must be provided
Fuse 6.3AT or MCB 6A C curve or 4A D curve
> 93%
< 42W
- 20C+ 60C (over temperature protection)
- 16W/C over 45C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
1kg
73 x 140 x 125mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 20mm spacing between adjacent items
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 400Vac)
NPST501-12
NPST501-24
NPST501-48
NPST501-72
12Vdc
1215Vdc
40A
60A / 5s
> 80A / 5s
24Vdc
2327.5Vdc
20A
30A / 5s
> 60A / 5s
48Vdc
4555Vdc
10A
15A / 5s
> 30A / 5s
72Vdc
7285Vdc
6.7A
10A / 5s
> 20A / 5s
< 1%
< 100mVpp
Protections
Output overvoltage protection
Parallel connection
> 18Vdc
Status Signals
INPUT DATA
Input rated current
(Vin = 400Vac)
(Vin = 500Vac)
Inrush peak current
(Vin = 400Vac)
Power factor
(Vin = 400Vac)
Internal protection fuse
External protection on AC line
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
> 100Vdc
GENERAL DATA
> 20ms
Overload, short circuit, with constant or hiccup mode (user settable)
Thermal protection
Input Undervoltage lockout
> 33Vdc
> 60Vdc
Up to 4 units for increased power
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
1.3A
1.1A
< 30A
> 0.6
None, external fuse must be provided
Fuse 3x 6.3AT or 3x MCB 6A C curve
> 90%
< 55W
> 93%
< 36W
- 20C+ 60C (over temperature protection)
- 10W/C over 50C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508 (certified), EN60950, CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
1.56mm, screw type (16...10AWG)
Aluminum
1.2kg
80 x 127 x 137.5mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 50mm spacing between adjacent items
> 95%
< 26W
27
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 400Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
Input rated voltage frequency
NPST721-24
NPST721-48
24Vdc
2327.5Vdc
30A
45A / 5s
> 80A / 5s
< 1.5%
48Vdc
4555Vdc
15A
22.5A / 5s
> 45A / 5s
< 1%
< 100mVpp
> 15ms
Overload, short circuit, with constant or hiccup mode (user settable)
Thermal protection
Input Undervoltage lockout
> 33Vdc
Up to 4 units for increased power
DC OK green LED
ALARM red LED
Dry contact 1A / 24Vdc
AC: 3 phase, 400500Vac / 4763Hz (range 340550Vac)
DC: 470...725Vdc
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
28
2.1A
1.8A
< 30A
> 0.6
None, external fuse must be provided
Fuse 3x 10AT or 3x MCB 10A C curve
> 92%
< 60W
> 93%
< 55W
IND.CONT.EQ
4WX9
PENDING
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 400Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
Input rated voltage frequency
Input rated current
(Vin = 400Vac)
(Vin = 500Vac)
Inrush peak current
(Vin = 400Vac)
Power factor
(Vin = 400Vac)
Internal protection fuse
External protection on AC line
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
NPST961-24
NPST961-48
NPST961-72
24Vdc
2327.5Vdc
40A
56A / 5s
> 90A / 5s
< 2%
48Vdc
4555Vdc
20A
28A / 5s
> 70A / 5s
< 1.5%
< 100mVpp
72Vdc
7285Vdc
13.3A
18.6A / 5s
> 30A / 5s
< 1%
> 15ms
Overload, short circuit, with constant or hiccup mode (user settable)
Thermal protection
Input Undervoltage lockout
> 33Vdc
> 60Vdc
> 100Vdc
Up to 4 units for increased power
DC OK green LED
ALARM red LED
Dry contact 1A / 24Vdc
AC: 3 phase, 400500Vac / 4763Hz (range 340550Vac)
DC: 470...725Vdc
2.8A
2.2A
< 30A
> 0.6
None, external fuse must be provided
Fuse 3x 10AT or 3x MCB 10A C curve
> 92%
< 80W
- 20C+ 60C (over temperature protection)
- 15W/C over 50C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508 (certified), EN60950, CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
1.510mm, screw type header (16...7AWG)
Aluminum
1.2kg
80 x 127 x 137.5mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 50mm spacing between adjacent items
> 94%
< 60W
29
30
Applications:
31
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
Protections
Output overvoltage protection
Status Signals
G
User interface
Parallel connection
INPUT DATA
NPS2400-24
NPS2400-48
NPS2400-72
NPS2400-170
24Vdc
11.929.0Vdc
100A
150A / 5s
150A
48Vdc
23.056.0Vdc
50A
75A / 5s
75A
72Vdc
50.087.0Vdc
33A
50A / 5s
50A
170Vdc
85.0175.0Vdc
14A
21A / 5s
21A
< 1%
< 200mVpp
> 10ms
Overload (with user settable threshold) - Short circuit - over temperature - overvoltage
Active, microprocessor controlled
DC OK green LED / ALARM red LED / Dry contact (1A / 30Vdc)
LCD with 4 key buttons
010V voltage output for output current 0100% In
420mA current output for output current 0100% In
Auxiliary 12V/100mA isolated power supply
Load voltage sense
Optoisolated remote shut down input
Optional: USB Communication interface via communication module
Optional: remote temperature sense for battery charging
Redundancy: integrated ORing circuit
Power: up to 4 units parallelable via load share bus
AC: 3 phase, 400500Vac / 4763Hz (range 340550Vac)
DC: 520...725Vdc
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals Input
Connection terminals Output
Connection terminals Signals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
32
4.5A
3.5A
< 10A active Inrush current limiter
> 0.92
None, external fuse must be provided
Fuse 3x 10AT or 3x MCB 10A C curve
> 92%
< 200W
> 92%
> 93%
< 200W
< 180W
- 20C+ 60C (over temperature protection)
- 60W/C over 50C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508 (certified), EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
1.56mm, screw type (16...10AWG)
35mm, screw type (2AWG)
1.5mm, screw type pluggable (24...12AWG)
Aluminum
2.8kg
233 x 160 x 101mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 80mm spacing between adjacent items
> 92%
< 200W
Applications:
54mm
73mm
33
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Status Signals
INPUT DATA
NPSW120-12
NPSW120-24
NPSW120-48P
1215Vdc
1215Vdc
8...7A
> 10A for > 30s
with Uout > 90% Un
> 20A for 400ms
24Vdc
2327.5Vdc
5A
> 7.5A for > 30s
with Uout > 90% Un
48Vdc
4555Vdc
2.5A
> 3.75A for > 30s
with Uout > 90% Un
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
34
> 20ms
> 80ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
Active > 18Vdc
Active > 33Vdc
Possible with external Oring diode
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
1.2A
0.6A
1.4A
0.7A
< 35A active Inrush current limiter
> 0.65
None, external fuse must be provided
Fuse 4AT or MCB 6A C curve or 6A D curve
1.4A
0.7A
> 83%
< 21W
> 87%
< 18W
- 20C+ 60C (over temperature protection)
- 4W/C over 45C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
0.5kg
40 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 20mm spacing between adjacent items
> 87%
< 18W
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 230Vac)
(Vin = 500Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
NPSW240-12
NPSW240-24
NPSW240-48P
NPSW240-72P
12...15Vdc
1215Vdc
1512A
> 20A for 6s
34A
24Vdc
2327.5Vdc
10A
> 15A for 6s
38A
48Vdc
4555Vdc
5A
> 7.5A for 6s
18A
72Vdc
7285Vdc
3.5A
> 5A for 6s
13A
< 1%
< 100mVpp
> 15ms
> 100ms
Electronic overload / short circuit protection
> 18Vdc
> 33Vdc
> 68Vdc
> 100Vdc
Possible with external Oring diode
Factory provided with internal Oring diode
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
GENERAL DATA
2.2A
1.1A
1.5A
0.8A
< 20A
< 40A
> 0.6
> 0.5
None, external fuse must be provided
Fuse 6.3AT or MCB 6A C curve or 4A D curve
> 90%
< 20W
> 92%
> 92%
< 21W
< 21W
- 20C+ 60C (over temperature protection)
- 6W/C over 50C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
0.65kg
54 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 20mm spacing between adjacent items
> 93%
< 19W
35
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 400Vac)
NPSW480-24
NPSW480-48
NPSW480-72
24Vdc
2327.5Vdc
20A
28A / 5s
50A
48Vdc
4555Vdc
10A
14A / 5s
25A
<1%
< 100mVpp
72Vdc
7285Vdc
6A
9A / 5s
12A
Protections
Output overvoltage protection
Parallel connection
> 33Vdc
Status Signals
INPUT DATA
Input rated voltage frequency
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
36
> 100Vdc
GENERAL DATA
> 20ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
> 68Vdc
Possible with external Oring diode
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
2.9A
1.3A
1.8A
0.8A
< 20A
< 40A
> 0.95
> 0.92
None, external fuse must be provided
Fuse 6.3AT or MCB 6A C curve or 4A D curve
> 92%
> 92%
< 42W
- 20C+ 60C (over temperature protection)
- 16W/C over 45C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
UL508, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
1kg
73 x 140 x 125mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 20mm spacing between adjacent items
> 91%
DC/DC CONVERTERS
Power
120W
240W
Model
NDD120-1212
NDD120-1224
NDD120-2412
NDD120-2424
NDD120-4812
NDD120-4824
NDD240-11024
Vdc IN
10.5...18
10.5...18
18...36
18...36
36...72
36...72
90...148
Vdc OUT
12...15
24
12...15
24
12...18
24
24
A
7
5
7
5
8
5
10
37
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
NDD1201212
NDD1201224
NDD1202412
NDD1202424
NDD1204812
12Vdc
24Vdc
1215Vdc
2327.5Vdc
7A
5A
9.1A
6.5A
12A / 300ms
12Vdc
1215Vdc
7A
9.1A
15A / 300ms
< 0.5%
24Vdc
2327.5Vdc
5A
6.5A
12A / 300ms
12Vdc
24Vdc
1215Vdc
2327.5Vdc
8A
5A
12A
6.5A
13A / 300ms
< 1.5%
< 100mVpp
< 200mVpp
> 6ms
> 3ms
< 100mVpp
> 1ms
Active
> 18Vdc
Active
> 33Vdc
Protections
Output overvoltage protection
Parallel connection
< 150mVpp
> 2ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
Active
Active
> 18Vdc
> 33Vdc
Possible with external Oring diode
DC OK green LED
Status Signals
Active
> 18Vdc
NDD1204824
Active
> 33Vdc
INPUT DATA
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
38
MCB 6A C curve
> 80%
> 83%
< 25W
> 87%
> 89%
< 16W
< 18W
< 17W
- 20C+ 50C (over temperature protection)
No derating
II
2 (IEC664-1)
2.2kVdc
1.41kVdc
0.75kVdc
EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
0.55kg
54 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
> 90%
< 13W
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
NDD240-11024
24Vdc
2327.5Vdc
10A
15A
21A / 300ms
< 1.5%
< 100mVpp
> 4ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
Active > 33Vdc
Factory provided with internal Oring diode
DC OK green LED
ALARM red LED
Dry contact 1A / 24Vdc
110Vdc (range 90148Vdc)
3.62.6A
> 150Vdc active shutdown
< 150A / < 2ms
Fuse 5AT / 250Vac
MCB 6A C curve
> 89%
< 27W
- 20C+ 50C (over temperature protection)
- 24W/C over 45C
II
2 (IEC664-1)
2.2kVdc
1.41kVdc
0.75kVdc
EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
0.8kg
69 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
39
40
High performance
Battery Charger/DC UPS
Integrated SMPS
Battery Charger/DC UPS
Buffer
Module
Redundancy
Module
41
D
TECHNICAL DATA
OUTPUT DATA
BATTERY SECTION
USER INTERFACE
GENERAL DATA
42
DCU20
Used to indicate the units status and the access the configuration menus
Used to program the unit and to access various menus
Constantly on: generic failure on the system, details on the LCD
Blinking: battery backup function active
Indicates that the unit is ready to operate (Ready)
Indicates a battery failure by toggling at 1Hz
Indicates that the load is operating from the battery (Backup)
Mini USB connector used to interface the unit with a PC
< 3W (on power supply) / < 7W (on battery)
> 90%
< 16W
User programmable, up to battery deep discharge threshold
- 20C+ 60C
- 20C+ 85C
750Vac
Natural convection cooling
EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
0.5mm, pluggable (28...20AWG)
Friction lock connector
Mini USB connector
Aluminum
0.5kg
54 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
TECHNICAL DATA
OUTPUT DATA
Status Signals
INPUT DATA
Voltage range
from Power Supply
Input rated current
GENERAL DATA
Operating temperature
Derating
Overvoltage category
Pollution degree
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
NUPS12
NUPS24
1015Vdc
2028Vdc
2A or 4A
10A Max
15A / 42V Car blade type, user replaceable
Vin 0.4V, min. 11Vdc
Vin 0.4V, min. 26Vdc
9.2Vdc 0.5V
18Vdc 0.5V
75% @ 26Vdc
75% @ 13Vdc
85% @ 13.5Vdc
85% @ 27Vdc
100% @ 14Vdc
100% @ 28Vdc
ON for U Batt. > 11.6Vdc 0.2V
ON for U Batt. > 23.5Vdc 0.2V
ON for U Batt. < 11.6Vdc 0.2V
ON for U Batt. < 23.5Vdc 0.2V
Battery reverse connection, battery short-circuit/overload, battery deep discharge
PS OK green LED
LOAD OK yellow LED
BATT. OK green LED
BATT. LOW red LED
REVERSE POLARITY red LED
Dry contact 1A / 24Vdc
1315.5Vdc
2628.5Vdc
> 3.0A
43
NCU120 120W Integrated DIN Rail Switching Power Supply, Battery Charger and DC-UPS Module
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin = 120Vac)
(Vin = 230Vac)
NCU120-12
NCU120-24
12...15Vdc
1215Vdc
7A
11A
> 18A / 50ms
24Vdc
2327.5Vdc
5A
8A
> 12A / 50ms
< 1%
< 80mVpp
> 24ms
> 80ms
> 17ms
> 72ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
Protections
Output overvoltage protection
Parallel connection
Status Signals
BATTERY INFO
Rated voltage
Max Charging current
Battery Protection
INPUT DATA
1214.4Vdc
2226.4Vdc
0.8A
against short-circuit with resettable fuse (9A)
against reverse polarity connection
against deep discharge ( 9V for NCU120-12 and 18V for NCU120-24 model)
AC: 120230Vac / 4763Hz (range 90264Vac)
DC: 110...345Vdc
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
44
2.0A
1.1A
< 20A
> 0.6
Fuse 3.15AT / 250Vac (not user replaceable)
Fuse 4AT or MCB 4A C curve
> 83%
< 20W
> 86%
< 19W
TECHNICAL DATA
BATTERY PACK INFO
Voltage capacity
Battery Size (W x H x D)
Internal protection fuse
Max Charging Current
Max Discharge Current
CONFIGURATION
NBP30
2 x Lead acid sealed batteries 12Vdc / 1.2Ah
48.5 x 54.5 x 97.5 mm Max
15A self resettable
12Vdc Configuration: 0.6A
24Vdc Configuration: 0.3A
12Vdc Configuration: 5A
24Vdc Configuration: 3A
Voltage / Capacity
Settable by external jumper
12Vdc / 2.4Ah
24Vdc / 1.2Ah
Operating temperature
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
- 20C+ 40C
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
1.2kg (2 batteries included)
54 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical
GENERAL DATA
45
IND.CONT.EQ
4WX9
TECHNICAL DATA
OUTPUT DATA
1285Vdc
50A Max
> 300A
< 2W
< 4m
1285Vdc
50A Max
< 1.5W
USER INTERFACE
Status signals
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Standards & Approvals
EMC Standards
Protection degree
Connection terminals Input
Connection terminals signals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
46
OR50
Rated voltage
Continuous current
Peak Output current
No load power consumption
Conduction resistance
INPUT DATA
TECHNICAL DATA
OUTPUT DATA
Voltage Unom
Continuous Output current
Max duration of the Output Voltage
Load = 20A
Ripple @ I Max
Overload / Short circuit protection
Overvoltage protection
Status Signals
INPUT DATA
Voltage range
Input current
GENERAL DATA
Operating modes
User settable by front botton
Control
Operating temperature
Storage temperature
Humidity
Cooling
Input / ground isolation
Safety standards
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
BU150U
Same as Input 1V (12/24/48/72Vdc 1V)
20A
600ms / 12V
300ms / 24V
150ms / 48V
75ms / 72V
< 250mVpp / 24Vdc
Active - One Shot
Active
DC OK green LED
OVERLOAD red LED
Dry contact 1A / 24Vdc
Nominal: 12/24/48/72Vdc - Auto detection
Max 20A
AUTO: follows the SMPS Output voltage
Fixed Output voltage (12/24/48/72Vdc)
CPU
- 20C+ 70C
- 20C+ 85C
Max RH 95% non condensing
Natural convenction
0.75kVdc
Compliant to UL508, CE marking
EN55011 (radiated emission), EN55011 (conducted emission)
IP20 acc. to EN60529
2.5mm, screw type pluggable (24...12AWG)
Aluminum
0.8kg
63 x 140 x 117mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 20mm spacing between adjacent items
47
48
MONITORING SYSTEMS
BATTMASTER
A high tech, low cost, compact battery monitoring system, easy to install and
operate - first wireless on the market.
Measures and stores: battery voltage, temperature, current, internal resistance
and discharging cycles for each battery of up to 1024 batteries.
Can be integrated with any remote supervising system based on GSM, Internet or
other communication means
Integrated database,
data backup and
restore functionalities.
POWERMASTER
Is a software tool used to configure and monitor the operation of the following
products:
for DCU20
49
BATTMASTER
CU
DAM
TECHNICAL DATA
CU
Supply input voltage range
Current consumption
Backup power
Digital inputs (user settable)
Digital outputs (user settable)
Data storage
Maximum number of supported devices
Ethernet
Connectivity
USB2
GSM
RF
Approx. Weight
Size (W x H x D)
DAM
Battery voltage range
Current consumption (typical)
RF
Battery Measures
Voltage
Ri
Temperature
Protections
Battery connection
Approx. Weight
Size (W x H x D)
IDAM
Supply input range
Current consumption (typical)
RF
Current Range
Protections
Approx. Weight
Size (W x H x D)
50
POWERMASTER
Start-up screen
For reference only
SCREEN SHOTS
NPS2400
DCU20
NPS2400 - Status
DCU20 - Status
M
NPS2400 - Settings
DCU20 - Settings
51
52
CUSTOM SOLUTIONS
Industrial automation
Railway
Elevator
Energy (low and medium voltage)
Energy storage (battery management)
Motor control
Telecom
Medical
Residential and commercial market
HW
Development
Design
SW
Development
Requirements
DFT + DFM
Research
Prototyping
Final Product
HW & SW
Integration
Mass Production
Product
Integration
Validation
Industrialization
53
TECHNICAL DATA
GENERAL DATA
Protections
Parallel connection
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals Input
Connection terminals Output
Connection terminals signals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
54
MBC2K
24110Vdc
50A for 1s
27106Vdc, threshold adjustable in 20 steps
3Vdc or 6Vdc selectable
2 setup push buttons (SET/RESET and MENU)
2 x 7 segment LED displays
1 LED for general alarm indication
1 SPDT Dry contact for general alarm remote warning
Undervoltage on DC BUS < 22Vdc
Overvoltage on DC BUS > 110Vdc
Brake resistor overtemperature (if the temperature sensor is present)
Module Internal overtemperature > 90C (194F)
Brake resistor interrupted or not connected
Short circuit: braking current > 80A
Overload: braking time > 1s
Up to 4 units can be connected in parallel through synchronization bus for a total braking power of 8kW
(4 x 2kW braking resistors are needed)
< 20W Max
- 20C+ 70C
No derating
I
2 (IEC664-1)
0.75kVdc
EN60950 for SELV use up to 60Vdc
using the MBC2K at voltages greater than 60Vdc is not classifiable as SELV, CE marking
EN55011 Class B
IP20 acc. to EN60529
2.5mm, screw type pluggable (2412AWG)
2.5mm, screw type pluggable (2412AWG)
1.5mm, screw type pluggable (24...12AWG)
Aluminum
0.2kg
40 x 115 x 110mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
A
Wide input voltage range
Latched overload and short-circuit protection
Designed in according to EN12015, EN12016 for elevators use
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin 230Vac)
(Vin 480Vac)
Protections
Output overvoltage protection
Parallel connection
Status Signals
INPUT DATA
Input rated voltage frequency
Input rated current
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
Mounting rail
Rail mounting information
WEPS160-26
26Vdc
26Vdc Fixed
6A
Up to 10A / 5s, latched protection
25A
< 1%
< 150mVpp
> 20ms
> 110ms
Overload and overvoltage latched off - over temperature - overvoltage
Active > 33Vdc latched off
Possible with external Oring diode
DC OK green LED
ALARM red LED
> 89%
< 25W
- 20C+ 50C (over temperature protection)
- 15W/C over 45C
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
EN12015, EN12016, EN60950 (reference), CE marking
EN61000-6-2, EN61000-6-4
IP20 acc. to EN60529
2.5mm, screw type header (24...12AWG)
Aluminum
0.5kg
108.5 x 110 x 74.5mm
IEC 60715/H15/TH35-7.5(-15)
Vertical, allow 10mm spacing between adjacent items
55
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
Protections
Output overvoltage protection
Parallel connection
INPUT DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Case material
Approx. Weight
Size (W x H x D)
> 84%
< 5W
- 20C+ 45C (over temperature protection)
No derating
II
2 (IEC664-1)
4.2kVdc
2.2kVdc
0.75kVdc
EN60950 (reference), CE marking
EN61000-6-1, EN61000-6-3
IP20 acc. to EN60529 when in wall mounted
1.5mm, screw type header (24...12AWG)
Casted Aluminum
0.225kg
68 x 68 x 60mm
GENERAL DATA
56
24Vdc
23.527.5Vdc
1A
4A / 30s
18A
< 0.5%
< 50mVpp
> 40ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
33Vdc
Not available
AC: 230Vac / 47...63Hz (range 187264Vac)
DC: 250...345Vdc
0.30A
< 20A
> 0.6
Fuse 2AT / 250Vac (not user replaceable)
MCB 4A C curve
WM100-24
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
(Vin 120Vac)
(Vin 230Vac)
Protections
INPUT DATA
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Storage Temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Standards & Approvals
EMC Standards
Protection degree
Connection terminals
Connection terminals Output
Case material
Approx. Weight
Size (W x H x D)
USW1-5
5.0Vdc
5.0Vdc Fixed
500mA
650mA
1200mA
< 2.0%
< 250mVpp
> 15ms
> 80ms
Overload/short circuit: hiccup
AC: 120 - 230Vac / 47...63Hz (range 85264Vac)
DC: 110...345Vdc
60mA
45mA
Fuse 800mAT / 250Vac (not user replaceable)
> 78%
< 60mW
- 20C+ 50C
- 20C+ 85C
No derating
II
2 (IEC664-1)
4.2kVdc
CE marking
EN61000-6-1, EN61000-6-3
IP20 according to EN60529
1.5mm, screw type header (24...12AWG)
USB-A female connectors
ABS, UL94V0
15g
18 x 32.6 x 35.5mm (PCB dimension)
To be hosted in a standard outlet module
57
TECHNICAL DATA
OUTPUT DATA
Rated voltage
Adj. output voltage range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple
Hold up time
Protections
Output overvoltage protection
Parallel connection
INPUT DATA
GENERAL DATA
Efficiency
Dissipated power
Operating temperature
Derating
Overvoltage category
Pollution degree
Input / output isolation
Input / ground isolation
Output / ground isolation
Standards & Approvals
EMC Standards
Connection terminals Input
Connection terminals Output
Approx. Weight
Size (W x H x D)
58
NPSR10-5
5.1Vdc
5.1Vdc Fixed
2.0A
2.5A
7.0A / 60ms
< 0.5%
< 100mVpp
> 50ms
Overload/short circuit: hiccup
Over temperature
Overvoltage
> 6.2Vdc
Possible with external Oring diode
DC: 110Vdc (range 66154Vdc)
0.3A
< 50A
Fuse 2AT / 250Vac (not user replaceable)
> 78%
< 3W
- 40C+ 85C (+ 85C at full load for Max. 10min)
- 0.13W/C over 70C
II
2 (IEC664-1)
2.2kVdc
1.5kVdc
0.71kVdc
EN50121, CE marking
EN50121-3-2
2.5mm, screw type pluggable (24...14AWG)
1.5mm, screw type pluggable (26...16AWG)
65g
50 x 26 x 70mm (PCB dimension)
Notes
Notes
Website
www.nextys.com
NEXTYS
www.nextys.com
Distributor