TEK 10-3
Movement Control (2003)
2
0.0007
Notes:
1. As = cross-sectional area of steel, in.2 /ft (mm2 /m).
An = net cross-sectional area of masonry, in.2 /ft (mm2 /m).
2. Maximum wall panel dimension criteria need not apply for walls
with a minimum horizontal reinforcement area, As of 0.002 times
the net cross sectional area of the masonry, An see Table 3.
3. See Table 2 for maximum spacings of reinforcement to meet
0.0007 minimum horizontal reinforcement ratio As/An.
4. The minimum horizontal reinforcement ratio criteria need not
apply for walls with a length not exceeding one half the maximum
length values shown above.
5. CCC's less than 0.0010 may be available in some areas and
spacing could be adjusted accordingly for this as well.
6. This criteria is based on an analytical study over a wide geographical area with wide temperature and and material property
variations. Control joint spacing may be adjusted up or down
based on local experience.
7. As shrinkage is related to moisture content, consider using the
higher crack control coefficient for masonry units that are wet
from lack of protection while stored on the jobsite.
Table 2Maximum Spacing of Horizontal Reinforcement to Meet the Criteria As > 0.0007An1
Wall
thickness,
in. (mm)
No. 5
(M 16)
(M 10)
(MW 18)
(MW 13)
(MW 11)
6 (152)
8 (203)
10 (254)
12 (305)
32 (813)
6 (152)
8 (203)
10 (254)
12 (305)
16 (406)
8 (203)
8 (203)
8 (203)
72 (1829)
56 (1422)
40 (1016)
32 (813)
48 (1219) 24 (610)
32 (813) 16 (406)
24 (610) 16 (406)
24 (610) 8 (203)
(MW 18)
walls
48 (1219) 40 (1016)
40 (1016) 32 (813)
32 (813) 16 (406)
24 (610)
16 (406)
16 (406)
16 (406)
16 (406)
16 (406)
8 (203)
8 (203)
8 (203)
8 (203)
8 (203)
8 (203)
32 (813)
24 (610)
16 (406)
8 (203)
16 (406)
8 (203)
8 (203)
8 (203)
Masonry lintel or
precast lintel
(notched if vertical
reinforcement in
cell next to opening
Vertical
reinforcement in
grouted cell each
side of opening (typ.)
(alternate-place in
second cell from
opening)
Lintel reinforcement
Sill
Control joint
(typ.)
Sill
REFERENCES
1. Building Code Requirements for Masonry Structures, ACI 530-02/ASCE 5-02/TMS 402-02, reported by the Masonry
Standards Joint Committee, 2002.
2. Selden, J. K. Shrinkage Characteristics of Concrete Masonry Walls, Housing and Home Finance Agency Paper 34, pages
1-60, 1954.
3. Control Joints for Concrete Masonry Walls Empirical Method, TEK 10-2B. National Concrete Masonry Association, 2003.
4. Standard Specification for Loadbearing Concrete Masonry Units, ASTM C 90-02. American Society for Testing and
Materials, 2002.
5. Standard Test Method for Linear Drying Shrinkage of Concrete Block , ASTM C 426-99. American Society for Testing
and Materials, 1999.
6. Toennies, H. T. Concrete Masonry Shrinkage. National Concrete Masonry Association, 1961.
Provided by:
Buehner Block Company, Inc.
Disclaimer: NCMA and the companies disseminating this technical information disclaim any and all responsibility and
liability for the accuracy and the application of the information contained in this publication.